Overall dimensions Oil Filled — copper windings 65˚C rise, ONAN. kVA Height Depth Flange to Flange Length Weight Fluid volume 84 83 89 92 96 99 108 108 124 129 129 (Lbs.) 6050 6850 8650 10750 12900 15500 19900 30200 41200 49200 57850 (gallons) 200 210 255 295 340 390 465 865 1270 1490 2175 Length Weight Fluid volume 83 83 94 83 86 (Lbs.) 6050 7350 10500 10750 12550 (gallons) 215 245 325 400 460 (inches) 750 1000 1500 2000 2500 3750 5000 7500 10000 12000 15000 90 90 90 90 90 90 90 109 117 117 119 67 72 78 98 105 114 154 135 135 146 163 60 59 64 67 69 72 77 78 93 99 98 Oil Filled — aluminum windings 65˚C rise, ONAN. kVA Height Depth Flange to Flange (inches) 750 1000 1500 2000 2500 90 90 90 90 90 67 73 75 109 114 59 59 69 69 69 For kVAs not listed, contact factory. Dimensions and weights are approximate and subject to change without notice and should not be used for construction purposes. TOP VIEW FRONT VIEW Performance data Overload ONAF 1 2 Insulation test levels Standard Self Cooled Forced Air Cooled ANSI1 ANSI ANSI CSA2 225-2000 KVA 2001-10000 KVA 10001-15000 KVA 225-15000 KVA +15% +25% +33% +33% ANSI C67.12.36 CSA C88 Temperature Rise Overload 65°C Base kVA 55/65°C +12% Induced Test Applied Distribution 180 or 400 Hz Voltage Test kV BIL 7200 Cycle 60 Hz (kV) 1.2 30 10 2.5 45 15 5 60 19 8.7 75 26 15 95 34 Twice Rated Voltage 25 (Grd Y Only) 125 40 25 150 50 34.5 (Grd Y Only) 125 50 34.5 150 70 46 200 95 kV Class Audible sound levels Percent impedance voltages kVA rating HV BIL (kV) 112.5-749 750-4999 750-4999 750-4999 750-4999 750-4999 5000-10 000 5000-10 000 5000-10 000 5000-10 000 ≤200 ≤110 150 200 250 350 ≤150 200 250 350 Impedance voltage LV 600 V LV above 600 V and below 1.70-5.75a 1.70-5.75a 5.75 5.75 6.75 6.5 7.25 7.0 7.75 7.5 8.0 6.5 7.0 7.5 8.0 a The minimum impedance listed in this table may produce available fault currents greater than the interrupting rating of down line equipment. Temperature rise ratings 0-3300 feet (0-1000 meters) Unit Rating Max. Ambient Temperature Average Ambient Temperature Average Winding Temperature Rise Hotspot Temperature Rise Standard Optional 65°C 40°C 30°C 65°C 80°C 55/65°C 50°C 40°C 55°C 65°C Derate kVA by 0.4 % for each 330 feet (100 M) above 3300 feet (1000 M). Self-Cooled, Two Winding kVA Rating 500 501-700 701-1000 1001-1500 1501-2000 2001-2500 2501-3000 3001-4000 4001-5000 5001-6000 6001-7500 7501-10000 12500 NEMA Average dB, ONAN dB, ONAF 56 57 58 60 61 62 63 64 65 66 67 68 69 67 67 67 67 67 67 67 67 67 68 70 71 71