Requirements
1
___________________
Introduction
2
___________________
Requirements
3
___________________
Additional information
Requirements
Getting Started
03/2013
A5E03973603-01
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
Siemens AG
Industry Sector
Postfach 48 48
90026 NÜRNBERG
GERMANY
A5E03973603-01
Ⓟ 03/2013 Technical data subject to change
Copyright © Siemens AG 2013.
All rights reserved
Table of contents
1
Introduction ............................................................................................................................................. 5
2
Requirements ......................................................................................................................................... 7
3
Additional information.............................................................................................................................. 9
Requirements
Getting Started, 03/2013, A5E03973603-01
3
Table of contents
Requirements
4
Getting Started, 03/2013, A5E03973603-01
Introduction
1
The new SIMATIC S7-1500 controller family with the Totally Integrated Automation Portal
(TIA Portal) offers you numerous new options to further increase the productivity of your
machines and to make the engineering process even more efficient. Explore the options in
this Getting Started.
In the first basic steps, you will get to know the new hardware better. We will also show you
how to configure and program the SIMATIC S7-1500 with SIMATIC STEP 7 V12 (TIA
Portal). The connection of a SIMATIC HMI Comfort Panel with SIMATIC WinCC Advanced
V12 (TIA Portal) or SIMATIC WinCC Professional V12 (TIA-Portal) completes the basic
steps.
Requirements
Getting Started, 03/2013, A5E03973603-01
5
Introduction
Requirements
6
Getting Started, 03/2013, A5E03973603-01
Requirements
2
Hardware requirements
To implement the hardware section of this Getting Started, you will need:
● 1 × CPU 1511-1 PN (6ES7511-1AK00-0AB0)
● 1 × S7-1500 load current supply PM 70W 120/230VAC (6EP1332-4BA00)
● 1 × Mounting rail (6ES7590-1AB60-0AA0)
● 1 × digital input module DI 16x24VDC SRC BA (6ES7521-1BH50-0AA0)
● 1 × digital output module DQ 16x24VDC/0.5A ST (6ES7522-1BH00-0AB0)
● 2 × Front connectors (6ES7592-1AM00-0XB0)
● 1 × SIMATIC Memory Card with at 4 MB (e.g. 6ES7954-8LBxx-0AA0)
● 1 × Ethernet cable
The hardware mentioned above is also part of the following starter package:
Starter package S7-1500 with software: 6ES7511-1AK00-4YB5
Software requirements
To implement the software section of this Getting Started, you will need:
● SIMATIC STEP 7 Professional V12
● SIMATIC WinCC Advanced V12 or SIMATIC WinCC Professional V12
WARNING
Severe personal injury may result
The S7-1500 automation system in plants or systems is governed by specific standards
and regulations, based on the relevant field of application. Please observe the applicable
safety and accident prevention regulations such as IEC 60204-1 (general machine safety
requirements).
Failure to observe these regulations can result in serious injuries and damages to
machinery and facilities.
Requirements
Getting Started, 03/2013, A5E03973603-01
7
Requirements
Requirements
8
Getting Started, 03/2013, A5E03973603-01
Additional information
3
Detailed information on the hardware used is available here:
● CPU 1511-1 PN (6ES7511-1AK00-0AB0)
(http://support.automation.siemens.com/WW/view/en/68020492)
● S7-1500 load current supply PM 70W 120/230VAC (6EP1332-4BA00)
(http://support.automation.siemens.com/WW/view/en/68036174)
● DI 16x24 V DC SRC BA digital input module (6ES7521-1BH50-0AA0)
(http://support.automation.siemens.com/WW/view/en/59191844/)
● DQ 16x24 V DC/0.5A ST digital output module (6ES7522-1BH00-0AB0)
(http://support.automation.siemens.com/WW/view/en/59193401)
Requirements
Getting Started, 03/2013, A5E03973603-01
9
Additional information
Requirements
10
Getting Started, 03/2013, A5E03973603-01