Tender No. 18 EE

advertisement
RAJKIYA ENGINEERING COLLEGE, MAINPURI
Tender No.: 18/EE/RECM/SPS/2016 Dated: 13.07.2016
due on 03.08.2016 by 1:30 pm
EMD: `7,500/Laboratory
Electrical
Engineering
Laboratory
Technical Specification / Model Details
Complete Setup For performing:
Verification of Kirchhoff’s laws (KVL/KCL)
Measurement of power and power factor in a single phase ac
series inductive circuit and study improvement of power factor
using capacitor
Study of phenomenon of resonance in RLC series circuit and
obtain resonant frequency.
Measurement of power in 3- phase circuit by two wattmeter
method and determination of its power factor.
Determination of parameters of ac single phase series RLC circuit
Determination of (i) Voltage ratio (ii) polarity and (iii) efficiency
by load test of a single phase transformer
To measure energy by a single phase energy meter and determine
error.
To study P-N diode characteristics
To study full wave and half wave rectifier circuits with and
without capacitor and determine ripple factors.
To study various logic gates (TTL)
To study Operational Amplifier as Adder and Sub tractor
To study transistor as a switch.
Rheostat up to 2000 Ohm,10Amp
DC Regulated Power Supply 0-30 Volt, 5Amp.
Bread Board With Power Supply ± 0-15 Volt in Box
Digital Multi-meter
C.R.O. up to 30 MHz
SINGLE PHASE RECTIFIER UNIT (WITH TRANSFORMER)
VARIAC CONTROLLED
Consisting of :1. MC Voltmeter 0-300 V
1 No.
2. MC Ammeter 0-25 A
1 No.
3. MI Voltmeter 0-300 V
1 No.
4. MI Ammeter 0-20 A
1 No.
5. Indicating Light for DC supply
1 No.
6. Indicating Light for 1 Phase AC supply
1 No.
7. MCB for AC supply
8. HRC Fuse for DC output
9. Rotary Switch for DC supply ON/OFF
10. Rotary Switch for AC input supply variation in steps.
11. Insulated terminals for AC supply and DC supply.
Qty.
02 each
10
05
05
05
05
SPECIFICATIONS
Input Voltage : Single Phase AC, 230V, 50 Hz, variable in steps through
rotary switch.
Output Voltage : DC continuously variable by varying auto transformer.
1
Diodes : RUTTANSHAH/USHA make. All the diodes are duly matched
current sharing-wise during testing for long life operation of the
equipment.
Transformer : This will be torroidal type transformer. The transformer
will have tappings for varying the input voltage to desired value by
means of rotary switch.
Variac : It is a continuously variable voltage auto transformer having a
movable carbon tip, fixed to brush arm sliding on a silver plated
commutator. Rotation of the brush arm by manual rotation delivers an
output voltage from 0 to or above line voltage by about 5%.
Capacity : 20 Amp.
RATINGS
Single Phase Rectifier Unit (with Transformer) (Variac Controlled) 20
Amp
type 250/60 suitable for D.C. Output of 250V, 60 A
2
Download