Installation/Operating Instructions Baronet/HW 110V and 220V Electric Projection Screen by Draper These Installation/Operating Instructions are available in the official language of the country where you purchase the product. Please contact your distributor to request a copy. Vous pourriez demander les instructions d’installation et d’opération traduises dans la langue officielle du pays ou vous achetez le produit. Veuillez demander à votre distributeur. Die Gebrauchsanweisung für Installation und Konstruktion sind in der offiziellen Sprache des Landes, indem Sie das Produkt gekauft haben, vorhanden. Fragen Sie die jeweilige Verkaufs-Abteilung. Caution Read instructions through completely before proceeding. Follow instructions carefully. Installation contrary to instructions invalidates warranty. Screen should be accessible for complete removal should fabric become damaged or should other service be required. Screen should be installed level (using a carpenter’s level). Nothing should be fastened to screen dowel or viewing surface. Operating switch(es) packed separately in screen carton. Do not discard with packing material. Screen operates on 110-120V AC, 60 Hz. or 220V AC, 50 Hz. or 60 Hz. current, depending on model ordered. NOTE: Screen has been thoroughly inspected and tested at factory and found to be operating properly prior to shipment. Wall Installation: Mount screen through holes in back of endcaps as shown. Installer should furnish appropriate hardware as required. Recessed Installation: Recess should permit access for removal of screen if necessary. Screen may be mounted as in suspended or wall installation. Angles may be used (provided by others). Electrical Connections Screen operates on 110-120V AC, 60 Hz./220V AC, 50 Hz. or 60 Hz. current, depending on model ordered. Duty Cycle: On 26 seconds/off 3 minutes. Junction box is located inside left endcap and cover plate is secured to endcap with two screws. Junction box contains pigtail leads and grounding screws, per wiring diagram on reverse. Screen is shipped with internal wiring complete and control switch(es) fully boxed. Wire connecting screen to switch(es) and switch(es) to power supply should be furnished by installer. Connections should be made in accordance with attached wiring diagram, and wiring should comply with National and local electrical codes. All operating switches should be “off” before power is connected. Do NOT wire motors in parallel. Operation Before operating screen, remove small foam pieces which keep dowel in case during shipping. Hanging Screen General: When locating viewing surface and checking clearance for screen’s operation, remember surface is centered in case. Handle case carefully to protect its finish. Regardless of mounting method, screen should be positively and securely supported so that vibration or even abusive pulling on the viewing surface will not cause case to work loose or fall. Installer must insure that fasteners used are of adequate strength and suitable for mounting surface chosen. Suspended Installation: Suspend screens from holes in top of endcaps as shown. "S" hooks, chains (or cable) and turnbuckles should be provided by installer. “S” hooks should go through the front holes on the endcaps (see drawing below), and both ends of the “S” hooks should be crimped for additional safety. Chains should be attached to beams or other structural members. Turnbuckles should be adjusted so screen hangs level. Front Back hole for wall mounting. Hardware by others. Crimp Crimp Mounting angle and hardware by others. Suggested for recessed installations. Adjustments Minimum 5 cm wide slot for passage of viewing surface if suspended above ceiling Copyright © 2015 Draper Inc. Top Hole for suspended mounting. Hardware by others. Rear Screen is equipped with a 3-position operating switch, located on the power cord. To lower the screen, move switch down. Screen will stop automatically when lower limit switch is reached. To raise the screen, move switch up. Again, the screen will stop automatically when the upper limit switch is reached. The screen may be stopped in any intermediate position by moving the switch to the center “off” position during operation.110-120V/220V Single Station Control — 3-position up-off-down switch permits operation to be stopped at any point. Factory adjusted limit switches automatically stop screen when fully down or fully up. 220V version is CE certified. 110-120V/220V Multiple Station Control—Switches are similar in appearance to 110V/220V Single Station Control. Screen stops when switch is released and may be restarted in either direction. Factory adjusted limit switches stop screen automatically when fully up or fully down. 24V Control — Three-button up-stop-down switches stop at any point desired, operate in any sequence. Factory adjusted limit switches automatically stop screen when fully up or fully down. Key Operated Switching — Two kinds of key-operated switches are optionally available with this unit. 1 The key-operated power supply switch controls power to the screen and switches. When it is “off ”, the switches will not operate screen. Key may be removed from the switch in either “on” or “off” position. 2 A three-position key switch permits the screen to be operated directly by key. In this case, the screen’s operator must always have a key. RS232/Ethernet—Serial communication and network communication optionally available with wall switches, RF or IR remote. Form BaronetHW_Inst15 Example of suspension above ceiling. Ceiling tile and grid (by others) Printed in U.S.A. Please Note: Screen limits are factory set for optimum performance of the screen. Any adjustment of these limits could void the warranty. Please check with Draper prior to resetting screen limits. CAUTION: Always be prepared to shut screen off manually when new adjustment is being tested. Screen may be severely damaged if viewing surface is allowed to run too far up or too far down. CAUTION: Be sure all switches are in “off” position before adjusting limit switches. “Down” limit switch: Down stopping position can be adjusted by turning white knob with a screw driver or hex wrench. Turning knob counterclockwise will allow viewing surface to run farther down. Turning it clockwise will reduce the amount of exposed viewing surface. “Up” limit switch: Up stopping position can be adjusted by turning red knob with a screw driver or hex wrench through the small grommet. Turning knob counterclockwise will allow surface to run farther into screen case. Turning it clockwise will allow viewing surface to stop farther out of screen case. Baronet/HW 110-120V Baronet/HW220V AC AC version is certified by version is CE certified. Underwriters’ Laboratories, Inc., for the U.S. and Canada. If you encounter any difficulties installing or servicing your Baronet/HW screen, call your dealer or contact Draper, Inc., Spiceland, Indiana, +1 765-987-7999 or fax +1 765-987-1689. Baronet/HW by Draper Page 2 of 2 Case Dimensions 3¼" (83 mm) Fabric width + 5¾" (146 mm) 3¼" (83 mm) 3¾" 96 mm Viewing Surface Wiring Diagrams Baronet/HW 110V AC Baronet/HW 220V AC (CE) Multiple Station Control Junction box at left end of screen Single Station Control Internal Screen Wiring White (Common) Black (Down) Red (Up) Green (Motor Ground) Internal Screen Wiring White (Common) Black (Down) Red (Up) Green (Motor Ground) Blue Black Control switch Single gang box by others Min. 4" x 2-1/8" x 1-7/8" deep. 3 shown. More or less equally feasible. Black 220v, PE 50 Hz. Low Voltage (& Wireless) Control Wiring Diagram CE Approved Low Voltage Control Module Black Red White Receiver Button Location of key operated 0n-off switch if furnished. White-110v or Blue-220v (Common) Black-110v or Brown-220v (Down) Red-110v or Black-220v (Up) 3 Button Wall Switch Green/Yellow YellowDOWN - Black Chassis ground label GreenCOM - White + Zinc plated chassis ground screw UP - Red All-Pole Disconnect Hot Black by Others Optional infrared receiver package Optional radio receiver package Electrically Straight Data Cable to 220v, more50 Hz. LVC-IV modules* RS232/485 Inputs/Outputs Wall Switch Low Voltage Trigger 3-28 VAC *A maximum of six (6) IR Eye Input LVC-IV modules can be linked together. Dashed wiring by electrician Low voltage wiring by others 110-120V 3-Position Wall Switch Internal Screen Wiring White Brown Red Black (Dn) Red (Up) White (Com) Dashed wiring by installer Junction box at left end of screen Neutral Control switches 24 VDC White or Blue-Common to screen & 110/220V AC Neutral Red-to screen (directional) Brown-to screen (directional) Yellow-to 110/220V AC-Hot Black-to 110/220V AC-Hot Green/Yellow (Ground) 220V 3-Position, Surface Mount Wall Switch 3.8 mm (1 1/2") 7 mm (2 3/4") 4.5 mm UP Dashed wiring by installer 220v, 50 Hz. Location of key operated on-off switch if furnished Black (Dn) Red (Up) White (Com) N Blue Red Hot Dashed wiring by installer Low Voltage, IR Remote or RF Remote (LVC-IV) To 110-120 VAC L1 Line GND Blue Black Neutral Black Blue Red Blue To 110V AC Line Internal Screen Wiring White (Common) Red (Up) Black 110 (Down) Green/Yellow (Motor Ground) Green/Yellow Chassis ground label Zinc plated chassis ground screw Red Black Red Please Note: Do not wire motors in parallel. + Cap off with wire nut and tape Blue Red To 110V AC Line Green/Yellow Chassis ground label Zinc plated chassis ground screw Dashed wiring by electrician Black Location of key operated on-off switch if furnished Not CE Approved Cap off with wire nut & tape Red Dashed wiring by electrician Multiple Station Control Internal Screen Wiring White-110v or Blue-220v (Common) Black-110v or Brown-220v (Down) Red-110v or Black-220v (Up) Internal Screen Wiring White-110v or Blue-220v (Common) Black-110v or Brown-220v (Down) Red-110v or Black-220v (Up) + Control switch Single gang box by others Min. 4" x 2-1/8" x 1-7/8" deep Blue Red Black Junction box at left end of screen CE Approved Junction box at left end of screen Neutral Junction box at left end of screen L1 Single Station Control (1 3/4") 3.2 mm (1 1/4") 3"-6" leads 11.8 mm (4 1/2") 8.6 mm (3 3/8") DOWN www.draperinc.com (765) 987-7999 7.8 mm (3 1/16")