MINERAL INSULATED CABLE (MI) OVERALL
Mineral insulated heating cable comprises an inner resistive
conductor of Copper, Cupro-nickel or Nichrome, surrounded by
compacted mineral insulation powder with an outer sheath of
Copper, Cupro-nickel or Stainless Steel.
A braided joint is fitted to each end of the heating cable length
connecting the cold lead (1m) to the heating cable.
The cable can be easily bent and formed to vessel contours.
Usage
Heating circuits can be fitted to tank and vessel surfaces using
a stainless steel punched strip spot welded at intervals to the
tank surface and into which the cable is clipped.
Alternative methods of fixing are with glass tape, tension
banding and spot welding using thin stainless steel strip.
Key Feature
 Fire resistant
 Overload resistance
Main Performance













Fire-resistive performance
Strong overload protection
Large current carrying capacity
High working temperature
Waterproof, anticorrosion and explosion-proof properties
Excellent shielding property
Strong radiation resistance
Long service life
Small outer diameter and light weight
Environmental protection and safety
High mechanical strength
Bending performance
Perfect earthing
IHP International Heating Products AB
Page 1 of 2
_________________________________________________________________________________________________________________
Industrivägen 2, SE-433 61 Sävedalen, Sweden
Phone: +46 (0)31 795 30 30 - Fax: +46 (0)31 795 30 39
Website: www.ihp.se - E-mail: info@ihp.se - Org. No. 556689-7327 - VAT No. SE556689732701
Bank: SEB Skandinaviska Enskilda Banken AB - F-Tax licensed
Applications















Metallurgical industry
Shipbuilding industry
Iron industry
Steel industry
Petrochemical industry
Gas
Nuclear power
Offshore oil
Medical industry
Mining
Paper industry
Military industry
Roads
Airports
Railway stations
Specification
Length .............................................. up to 150m
Element ø .......................................... 2.8-5.9mm (depending on raiting)
Connections ...................................... At each end
Supply voltage ................................... 110V and 240 V
Cold leads.......................................... 1m mineral insulated
Power rating ..................................... up to 4KW
Minimum bending radius ................... 5 times cable diameter
IHP International Heating Products AB
Page 2 of 2
_________________________________________________________________________________________________________________
Industrivägen 2, SE-433 61 Sävedalen, Sweden
Phone: +46 (0)31 795 30 30 - Fax: +46 (0)31 795 30 39
Website: www.ihp.se - E-mail: info@ihp.se - Org. No. 556689-7327 - VAT No. SE556689732701
Bank: SEB Skandinaviska Enskilda Banken AB - F-Tax licensed
Download