Turning Air Into Solutions. Canted Self-Flashing Vented (Restaurant) Self-Flashing Fiberglass Roof Curb Curb Adapter PREFABRICATED ROOF CURBS CATALOG 4910 December 2013 CantedRoofCurb Series RCPF Features 11/2" Wood Nailer A SQ. 11/2" Fiberglass Insulation (Standard) Curb Height 4" Damper Shelf (Standard) Backdraft Damper (Optional) Options A + 8" NOTES: 1. Curbs are sized 11⁄2" less than fan base to allow 3⁄4" each side for flashing material and clearance. 2. Inside of curb is 3" less than Dimension “A”. 3. For aluminum curb substitute RCPFAI in place of RCPFGI. 4. When using a motor operated damper in the curb, a 12"‑high (minimum) curb is required. MODEL BCRFS BCRD & BCRD-E (thru size 240) BCRU DCRD DCRU GRV FAN SIZE 090 100 120, 150 180 200 220 70, 75, 85 100, 120 140 160 180, 210 240 300 360 420 480 110, 120 140, 160 180 210, 240 300 360 420 480 60 - 100 120 130, 140 150, 160 170, 180 71 - 83 91 - 93 110, 120 140, 160 180 90 120, 160 180, 210 240, 270 300,320,360 420 480 • Constructed of 18-gauge galvanized steel with continuous welded seams • Large 3" built-in 45° cant to accommodate roofing material to top of curb. Cant is beveled at corners for better support of roofing material • Wood nailer (11∕2") secured to top ledge • Lined with 11∕2" fiberglass fire-resistant, soundabsorbing insulation • Damper shelf • Aluminum (16-gauge) construction • Burglar security bars • Metal liner (galvanized or aluminum) • Special heights up to 24" BASE I.D. 24 x 24 30 x 30 34 x 34 40 x 40 46 x 46 54 x 54 17 x 17 20 x 20 24 x 24 26 x 26 30 x 30 34 x 34 40 x 40 46 x 46 52 x 52 58 x 58 ROOF CURB DIM. A (SQ) 22.5 x 22.5 28.5 x 28.5 32.5 x 32.5 38.5 x 38.5 44.5 x 44.5 52.5 x 52.5 15.5 x 15.5 18.5 x 18.5 22.5 x 22.5 24.5 x 24.5 28.5 x 28.5 32.5 x 32.5 38.5 x 38.5 44.5 x 44.5 50.5 x 50.5 56.5 x 56.5 8” HIGH CURB RC22508PFGI RC28508PFGI RC32508PFGI RC38508PFGI RC44508PFGI RC52508SFGI RC15508PFGI RC18508PFGI RC22508PFGI RC24508PFGI RC28508PFGI RC32508PFGI RC38508PFGI RC44508PFGI RC50508PFGI RC56508PFGI PART NUMBER 12” HIGH CURB RC22512PFGI RC28512PFGI RC32512PFGI RC38512PFGI RC44512PFGI RC52512SFGI RC15512PFGI RC18512PFGI RC22512PFGI RC24512PFGI RC28512PFGI RC32512PFGI RC38512PFGI RC44512PFGI RC50512PFGI RC56512PFGI 18” HIGH CURB RC22518PFGI RC28518PFGI RC32518PFGI RC38518PFGI RC44518PFGI RC52518SFGI RC15518PFGI RC18518PFGI RC22518PFGI RC24518PFGI RC28518PFGI RC32518PFGI RC38518PFGI RC44518PFGI RC50518PFGI RC56518PFGI 24 x 24 22.5 x 22.5 RC22508PFGI RC22512PFGI RC22518PFGI 30 34 40 46 52 58 17 20 28.5 32.5 38.5 44.5 50.5 56.5 15.5 18.5 28.5 32.5 38.5 44.5 50.5 56.5 15.5 18.5 RC28508PFGI RC32508PFGI RC38508PFGI RC44508PFGI RC50508PFGI RC56508PFGI RC15508PFGI RC18508PFGI RC28512PFGI RC32512PFGI RC38512PFGI RC44512PFGI RC50512PFGI RC56512PFGI RC15512PFGI RC18512PFGI RC28518PFGI RC32518PFGI RC38518PFGI RC44518PFGI RC50518PFGI RC56518PFGI RC15518PFGI RC18518PFGI 24 x 24 22.5 x 22.5 RC22508PFGI RC22512PFGI RC22518PFGI 30 x 30 17 x 17 20 x 20 28.5 x 28.5 15.5 x 15.5 18.5 x 18.5 RC28508PFGI RC15508PFGI RC18508PFGI RC28512PFGI RC15512PFGI RC18512PFGI RC28518PFGI RC15518PFGI RC18518PFGI 24 x 24 22.5 x 22.5 RC22508PFGI RC22512PFGI RC22518PFGI 28.5 15 22.5 28 34 41 50.5 56.5 RC28508PFGI RC15008PFGI RC22508PFGI RC28008PFGI RC34008PFGI RC41008PFGI RC50508PFGI RC56508PFGI RC28512PFGI RC15012PFGI RC22512PFGI RC28012PFGI RC34012PFGI RC41012PFGI RC50512PFGI RC56512PFGI RC28518PFGI RC15018PFGI RC22518PFGI RC28018PFGI RC34018PFGI RC41018PFGI RC50518PFGI RC56518PFGI 30 16.5 24 29.5 35.5 42.5 52 58 x x x x x x x x x x x x x x x x 30 34 40 46 52 58 17 20 30 16.5 24 29.5 35.5 42.5 52 58 x x x x x x x x x x x x x x x x 28.5 15 22.5 28 34 41 50.5 56.5 DIMENSIONS ARE NOT TO BE USED FOR CONSTRUCTION. 2 Twin City Fan Catalog 4910 Self-FlashingRoofCurb Series RCSF Features • Constructed of 18-gauge galvanized steel with continuous welded seams • Wide base plate (flashing) to insure watertight bond to roof • Top ledge covered with 3∕16" polystyrene gasket for weather seal and to reduce metal-to-metal conducted noise • Lined with 11∕2" fiberglass fire-resistant, soundabsorbing insulation • Damper shelf 3/16" 11/2" Fiberglass Insulation (Standard) 2" Damper Shelf (Standard) • Aluminum (16-gauge) construction • Burglar security bars • Metal liner (galvanized or aluminum) • Special heights up to 24" • Wood nailer (11∕2") secured to top ledge in lieu of polystyrene gasket • Single or double pitched curbs for sloping roofs BCRFS BCRD & BCRD-E (thru size 240) BCRU DCRD DCRU GRV Curb Height Backdraft Damper (Optional) A + 4" Options MODEL Polystyrene Gasket A SQ. FAN SIZE 090 100 120, 150 180 200 220 70, 75, 85 100, 120 140 160 180, 210 240 300 360 420 480 110, 120 140, 160 180 210, 240 300 360 420 480 60 - 100 120 130, 140 150, 160 170, 180 71 - 83 91 - 93 110, 120 140, 160 180 90 120, 160 180, 210 240, 270 300,320,360 420 480 NOTES: 1. Curbs are sized 1⁄2" less than fan base to allow 1⁄4" each side for clearance. 2. Inside of curb is 3" less than Dimension “A”. 3. For aluminum curb substitute RCSFAI in place of RCSFGI. 4. When using a motor operated damper in the curb, a 12"‑high (minimum) curb is required. BASE I.D. 24 x 24 30 x 30 34 x 34 40 x 40 46 x 46 54 x 54 17 x 17 20 x 20 24 x 24 26 x 26 30 x 30 34 x 34 40 x 40 46 x 46 52 x 52 58 x 58 ROOF CURB DIM. A (SQ) 23 x 23 29 x 29 33 x 33 39 x 39 45 x 45 53 x 53 16.5 x 16.5 19.5 x 19.5 23.5 x 23.5 25.5 x 25.5 29.5 x 29.5 33.5 x 33.5 39.5 x 39.5 45.5 x 45.5 51.5 x 51.5 57.5 x 57.5 8” HIGH CURB RC23008SFGI RC29008SFGI RC33008SFGI RC39008SFGI RC45008SFGI RC53008SFGI RC16508SFGI RC19508SFGI RC23508SFGI RC25508SFGI RC29508SFGI RC33508SFGI RC39508SFGI RC45508SFGI RC51508SFGI RC57508SFGI PART NUMBER 12” HIGH CURB RC23012SFGI RC29012SFGI RC33012SFGI RC39012SFGI RC45012SFGI RC53012SFGI RC16512SFGI RC19512SFGI RC23512SFGI RC25512SFGI RC29512SFGI RC33512SFGI RC39512SFGI RC45512SFGI RC51512SFGI RC57512SFGI 18” HIGH CURB RC23018SFGI RC29018SFGI RC33018SFGI RC39018SFGI RC45018SFGI RC53018SFGI RC16518SFGI RC19518SFGI RC23518SFGI RC25518SFGI RC29518SFGI RC33518SFGI RC39518SFGI RC45518SFGI RC51518SFGI RC57518SFGI 24 x 24 23.5 x 23.5 RC23508SFGI RC23512SFGI RC23518SFGI 30 34 40 46 52 58 17 20 29.5 33.5 39.5 45.5 51.5 57.5 16.5 19.5 29.5 33.5 39.5 45.5 51.5 57.5 16.5 19.5 RC29508SFGI RC33508SFGI RC39508SFGI RC45508SFGI RC51508SFGI RC57508SFGI RC16508SFGI RC19508SFGI RC29512SFGI RC33512SFGI RC39512SFGI RC45512SFGI RC51512SFGI RC57512SFGI RC16512SFGI RC19512SFGI RC29518SFGI RC33518SFGI RC39518SFGI RC45518SFGI RC51518SFGI RC57518SFGI RC16518SFGI RC19518SFGI 24 x 24 23.5 x 23.5 RC23508SFGI RC23512SFGI RC23518SFGI 30 x 30 17 x 17 20 x 20 29.5 x 29.5 16.5 x 16.5 19.5 x 19.5 RC29508SFGI RC16508SFGI RC19508SFGI RC29512SFGI RC16512SFGI RC19512SFGI RC29518SFGI RC16518SFGI RC19518SFGI 24 x 24 23.5 x 23.5 RC23508SFGI RC23512SFGI RC23518SFGI 29.5 16 23.5 29 35 42 51.5 57.5 RC29508SFGI RC16008SFGI RC23508SFGI RC29008SFGI RC35008SFGI RC42008SFGI RC51508SFGI RC57508SFGI RC29512SFGI RC16012SFGI RC23512SFGI RC29012SFGI RC35012SFGI RC42012SFGI RC51512SFGI RC57512SFGI RC29518SFGI RC16018SFGI RC23518SFGI RC29018SFGI RC35018SFGI RC42018SFGI RC51518SFGI RC57518SFGI 30 16.5 24 29.5 35.5 42.5 52 58 x x x x x x x x x x x x x x x x 30 34 40 46 52 58 17 20 30 16.5 24 29.5 35.5 42.5 52 58 x x x x x x x x x x x x x x x x 29.5 16 23.5 29 35 42 51.5 57.5 DIMENSIONS ARE NOT TO BE USED FOR CONSTRUCTION. www.tcf.com 3 Self-FlashingVentedRoofCurb Series RCSFV For Use on Roof Mounted Restaurant Exhaust Fans Features • Completely assembled unit, easier to install and less expensive than a field constructed curb • Constructed of 18-gauge galvanized steel with continuous welded seams with wide base flashing for weathertight seal to roof • Meets NFPA-96 code requirements • Top ledge covered with 3∕16" polystyrene gasket • Furnished with ventilation slots 3 /16" Polystrene Gasket A SQ. 4" x 1/2" Vent Slots A – 3" Curb Height 2" A + 4" NOTES: 1. Curbs are sized 11⁄2" less than fan base to allow 3⁄4" clearance on each side for curb hinge (if required). FAN SIZE BASE I.D. 110 120 24 x 24 140 160 180 30 x 30 BCRUR 210 34 x 34 240 300 40 x 40 360 46 x 46 071-073 17 x 17 081-083 091-093 20 x 20 110 DCRUR 120 24 x 24 140 160 180 30 x 30 MODEL PART NUMBER ROOF CURB DIM. A (SQ) 12” HIGH CURB 18” HIGH CURB 22.5 x 22.5 RC22512SFVG RC22518SFVG 28.5 x 28.5 RC28512SFVG RC28518SFVG 32.5 x 32.5 RC32512SFVG RC32518SFVG 38.5 x 38.5 44.5 x 44.5 RC38512SFVG RC44512SFVG RC38518SFVG RC44518SFVG 15.5 x 15.5 RC15512SFVG RC15518SFVG 18.5 x 18.5 RC18512SFVG RC18518SFVG 22.5 x 22.5 RC22512SFVG RC22518SFVG 28.5 x 28.5 RC28512SFVG RC28518SFVG DIMENSIONS ARE NOT TO BE USED FOR CONSTRUCTION. 4 Twin City Fan Catalog 4910 SoundAttenuatingRoofCurb Series RCSA A special sound-absorbing curb designed for use with power roof ventilators where exceptionally quiet operation is required. Features • Reduces the roof fan noise transmitted into building. Typical performance of sound attenuating curb will result in a 40% reduction of sone value with a 7% loss in CFM • Designed with streamlined airflow passages using a core of modular type sound-absorbing cells of special fiberglass held in a galvanized steel frame • Constructed of 18-gauge galvanized steel with continuous welded seams • Large 3" built-in 45° cant to accommodate roofing material to top of curb • Wood nailer (11∕2") secured to top ledge • Lined with 11∕2" fiberglass fire-resistant, soundabsorbing insulation • Damper box Sound-Absorbing Cells 11/2" Wood Nailer A SQ. 4" 16" H. 8" Damper Box (Standard) Backdraft Damper (Optional) 11/2" Fiberglass Insulation (Standard) A + 8" NOTES: 1. Curbs are sized 11⁄2" less than fan base to allow 3⁄4" each side for flashing material and clearance. 2. For aluminum curb substitute RCSAAI in place of RCSAGI. Options • Aluminum (16-gauge) construction • Also available in self-flashing or raised cant design Sound Curb Pressure Loss MODEL BCRD BCRD-E BCRU DCRD DCRU FAN SIZE 70, 75, 85 100, 120 140 160 180, 210 240 300 360 420 480 70, 75, 85 100, 120 140 160 180, 210 240 110, 120 140, 160 180 210, 240 300 360 420 480 60 - 100 120 130, 140 150, 160 170, 180 71 - 83 91 - 93 110, 120 140, 160 180 BASE I.D. 17 x 17 20 x 20 24 x 24 26 x 26 30 x 30 34 x 34 40 x 40 46 x 46 52 x 52 58 x 58 17 x 17 20 x 20 24 x 24 26 x 26 30 x 30 34 x 34 ROOF CURB DIM. A (SQ) 15.5 x 15.5 18.5 x 18.5 22.5 x 22.5 24.5 x 24.5 28.5 x 28.5 32.5 x 32.5 38.5 x 38.5 44.5 x 44.5 50.5 x 50.5 56.5 x 56.5 15.5 x 15.5 18.5 x 18.5 22.5 x 22.5 24.5 x 24.5 28.5 x 28.5 32.5 x 32.5 PART NUMBER 16” HIGH CURB RC15516SAGI RC18516SAGI RC22516SAGI RC24516SAGI RC28516SAGI RC32516SAGI RC38516SAGI RC44516SAGI RC50516SAGI RC56516SAGI RC15516SAGI RC18516SAGI RC22516SAGI RC24516SAGI RC28516SAGI RC32516SAGI 24 x 24 22.5 x 22.5 RC22516SAGI 30 34 40 46 52 58 17 20 28.5 32.5 38.5 44.5 50.5 56.5 15.5 18.5 RC28516SAGI RC32516SAGI RC38516SAGI RC44516SAGI RC50516SAGI RC56516SAGI RC15516SAGI RC18516SAGI x x x x x x x x 30 34 40 46 52 58 17 20 x x x x x x x x 28.5 32.5 38.5 44.5 50.5 56.5 15.5 18.5 24 x 24 22.5 x 22.5 RC22516SAGI 30 x 30 17 x 17 20 x 20 28.5 x 28.5 15.5 x 15.5 18.5 x 18.5 RC28516SAGI RC15516SAGI RC18516SAGI 24 x 24 22.5 x 22.5 RC22516SAGI 30 x 30 28.5 x 28.5 RC28516SAGI VELOCITY FPM* 200 400 600 800 1000 1200 1500 2000 ∆P IN. W.G. .01 .02 .04 .07 .11 .16 .25 .44 *Velocity through curb inlet. DIMENSIONS ARE NOT TO BE USED FOR CONSTRUCTION. www.tcf.com 5 RoofCurbAdapter Series RCCA Features • Constructed of heavy-gauge galvanized steel with continuous welded seams • Top ledge covered with 3∕16" polystyrene gasket to reduce metal-to-metal conducted noise and act as a weather seal Style A A Outside 3/16" Polystyrene Gasket 1.50 (For use with oversize, existing curb) 5.50 Recommended Sizing: Dimension A =Fan Base (Cap) Minus 1∕2" Dimension B =Roof Curb Outside Dimension Plus 11∕2" 2.50 B Inside Style B (For use with smaller, existing curb) A Outside 3/16" Polystyrene Gasket C 1.50 4.00 Recommended Sizing: Dimension A =Fan Base (Cap) Minus 1∕2" Dimension B =Roof Curb Outside Dimension Plus 1∕2" Dimension C =(A – B) ÷ 2 B Inside Note: Use of a large fan on a smaller, existing curb may cause an inlet obstruction and result in reduced fan performance. DIMENSIONS ARE NOT TO BE USED FOR CONSTRUCTION. RoofCurbExtension Series RCCE Features • Constructed of 18-gauge galvanized steel with continuous welded seams for water tightness and extra strength • 3∕16" polystyrene gasket on top ledge to reduce metal-to-metal conducted noise and act as a weather seal • Lined with 11∕2" fiberglass fire resistant, sound absorbing insulation • Built-in back draft damper shelf and removable access panel Options • Heights up to 24" (13" is standard) • Vent slots (no insulation or damper shelf) 3/16" Polystyrene Gasket A SQ. Outside 13" 23/4" Backdraft Damper (Optional) B SQ. Inside Damper Shelf (Standard) Recommended Sizing: Dimension A =Fan Base Minus 1∕2" Dimension B =A Minus 1∕4" 6 Twin City Fan Catalog 4910 FiberglassRoofCurbs Series EF (w/insulation) Series E A SQ. 3-1/2" A SQ. 3-1/2" Treated Wood Nailer 2" Treated Wood Nailer Heavy Reinforced Fiberglass Fiberglass Insulation 11-1/2" 11-1/2" G SQ. 45 Heavy Reinforced Fiberglass 2" G SQ. 45 Roof Backdraft Damper (Optional) Damper Tray (Standard) E12F — A 12" high, beige color, molded fiberglass, reinforced polyester resin, double shell, prefabricated roof curb with a 31∕2" cant, corner gussets, 2" thick fiberglass insulation, and incorporating a treated 11∕2" x 31∕2" treated wood nailer and damper tray. FAN / HOOD MODEL FA FAB WA WAB FR MA SIZE 7, 9 10, 12, 14 18 12, 14 18 24 30 36, 40 7 10, 12 14 18 14 18 24 30 36, 40 1A, 1B 2A, 2B 3A, 3B 4A, 4B 5A, 5B 6A 6 8 10 12 15 18 20 24 30 34 36 38 42 48 54 60 BASE I.D. 22 26 30 26 30 37 45 53 17 21 24.8 29 24.8 29 37.5 45.5 53 22 26 30 37 45 52.3 15 17 19 21 24.3 27 29 33 39 43 45.5 47.5 51.5 57.5 63.5 69.5 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 22 26 30 26 30 37 45 53 17 21 24.8 29 24.8 29 37.5 45.5 53 22 26 30 37 45 52.3 15 17 19 21 24.3 27 29 33 39 43 45.5 47.5 51.5 57.5 63.5 69.5 NOTE: Damper to have 15⁄8" flange. ROOF CURB DIM. A (SQ) 20 24 28 24 28 36 44 52 16 20 24 28 24 28 36 44 52 20 24 28 36 44 52 14 16 18 20 24 26 28 32 38 42 44 46 50 56 62 68 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 20 24 28 24 28 36 44 52 16 20 24 28 24 28 36 44 52 20 24 28 36 44 52 14 16 18 20 24 26 28 32 38 42 44 46 50 56 62 68 Backdraft Damper (Optional) Damper Tray (Standard) E12 — A 12" high, beige color, molded fiberglass, reinforced polyester resin, single shell, prefabricated roof curb with a 31∕2" cant, corner gussets, and incorporating a treated 11∕2" x 31∕2" treated wood nailer and damper tray. 12” HIGH CURB WITH INSULATION PART APPROX. SHIP NUMBER WT. (LB) 15025104 38 15025105 46 15025107 53 15025105 46 15025107 53 15025109 68 15025112 82 15025115 99 15025102 31 15025104 38 15025105 46 15025107 53 15025105 46 15025107 53 15025109 68 15025112 82 15025115 99 15025104 38 15025105 46 15025107 53 15025109 68 15025112 82 15025115 99 15025101 28 15025102 31 15025103 34 15025104 38 15025105 46 15025106 49 15025107 53 15025108 60 15025110 72 15025111 76 15025112 82 15025113 86 15025114 92 15025116 108 15025117 119 15025118 130 12” HIGH CURB NON-INSULATED PART APPROX. SHIP NUMBER WT. (LB) 15025004 31 15025005 38 15025007 44 15025005 38 15025007 44 15025009 56 15025012 67 15025015 80 15025002 26 15025004 31 15025005 38 15025007 44 15025005 38 15025007 44 15025009 56 15025012 67 15025015 80 15025004 31 15025005 38 15025007 44 15025009 56 15025012 67 15025015 80 15025001 24 15025002 26 15025003 28 15025004 31 15025005 38 15025006 41 15025007 44 15025008 49 15025010 59 15025011 63 15025012 67 15025013 71 15025014 75 15025016 88 15025017 96 15025018 105 G (SQ) 10.63 14.63 18.63 14.63 18.63 24.63 30.63 36.63 6.63 10.63 14.63 18.63 14.63 18.63 24.63 30.63 36.63 10.63 14.63 18.63 24.63 30.63 36.63 4.63 6.63 8.63 10.63 14.63 16.63 18.63 22.63 28.63 32.63 34.63 36.63 40.63 46.63 52.63 58.63 DAMPER SIZE WHEN REQ'D 10 14 18 14 18 24 30 36 6 10 14 18 14 18 24 30 36 10 14 18 24 30 36 4 6 8 10 14 16 18 22 28 32 34 36 40 46 52 58 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 10 14 18 14 18 24 30 36 6 10 14 18 14 18 24 30 36 10 14 18 24 30 36 4 6 8 10 14 16 18 22 28 32 34 36 40 46 52 58 Dimensions are not to be used for construction. www.tcf.com 7 INDUSTRIAL & COMMERCIAL FANS Centrifugal Fans | Utility Sets | Plenum & Plug Fans | Inline Centrifugal Fans Mixed Flow Fans | Tubeaxial & Vaneaxial Fans | Propeller Wall Fans | Propeller Roof Ventilators Centrifugal Roof & Wall Exhausters | Ceiling Ventilators | Gravity Ventilators | Duct Blowers Radial Bladed Fans | Radial Tip Fans | High Efficiency Industrial Fans | Pressure Blowers Laboratory Exhaust Fans | Filtered Supply Fans | Mancoolers | Fiberglass Fans | Custom Fans TWIN CITY FAN & BLOWER | WWW.TCF.COM TwinCity City FanFan Companies, Ltd. A Twin Company 1MWG12/13 5959 Trenton Lane N | Minneapolis, MN 55442 | Phone: 763-551-7600 | Fax: 763-551-7601