3255 WALL WASH ® BeveLED PROJECT INFORMATION ™ Innfinite Coloor+ PROJECT DATE TYPE 1" Regress ™ BeveLED In nfifinnite Color+ Recessed Wall Wash - Illuminate your space with any color available in the spectrum with BeveLED Infinite Color+. Tune the light from saturated blue, violet, green, yellow, orange, and red, to any of a wide variety of perfect architectural whites with DMX512 controls. Infinite opportunities abound for hospitality, entertainment, and cultural lighting applications, or any other project requiring full color and white light flexibility. 1" Regress 1" Regress Bevel Finish Color area Flange Finish Color area 41⁄2"Ø 51⁄2"Ø HOW TO SPECIFY Ordering Example: Specify trim code and housing code to order: Example : 3255W - B1- 10 - LRTW4 - 6032 - WRGB1 - 30KS - NC - 277V - DMX1M - RJ - CB27 TRIM ORDERING INFORMATION 3255 3255 Round Wall Wash 1" Regress ™ BEVEL STYLE OPTION – ______ Wet location 1 W In nfinite Color+ Spectrum FLANGE FINISH Relative Output (W/nm) TRIM – B1 1” Regress Bevel, Painted Die Cast Matches Flange Finish AB1 1” Regress Bevel, Black Anodized AC1 1” Regress Bevel, Clear Matte Anodized 1 Wet location, use with B1 trims only. 01 Clear Matte (AC Bevel only) 02 Black Anodized (AB Bevel only) 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) 1 0.8 0.6 0.4 0.2 0 400 450 500 550 600 650 700 750 wavelength (nm) Independently mix white light with color in any combination imaginable to create a uniquely personal light source. HOUSING ORDERING INFORMATION HOUSING CODE WATTAGE – LRTW4 LRTW4 – WRGB1 6032 6032 32W LED, 1225 Lumen Maximum PRIMARY WHITE ENGINE CODE WRGB1 – 30KS 30KS 3000K, 80+ CRI – NC New Construction CP Chicago Plenum 2 IC Insulation-Contact Rated / Airtight 2 2 USAI Lighting ® www.usailighting.com info@usailighting.com VOLTAGE HOUSING TYPE – 120V 277V ACCESSORIES – – RJ RJ45 Jacks DMX1M EldoLED DMX 0.1% dimming, manual WR Splice Connection addressing using XL XLR5 Connectors 3 RDM protocol, 8 bit DMX2M EldoLED DMX 0.1% dimming, manual addressing using RDM protocol, 16 bit 3 Requires above ceiling access; N/A with IC or CP housings. Not available with EM. 1126 River Road New Windsor, NY 12553 CABLING DIMMING DRIVER – T 845–565–8500 F 845–561–1130 CB27 CB52 EML EMLW 27” C-Channel Bars 52” C-Channel Bars Emergency battery 4 Emergency battery, wet location 4 4 For use with NC housing only. Provided with remote test switch. © 2015. USAI, LLC. All rights reserved. All designs protected by copyright. Revised 09/24/2015 WALL WASH ® BeveLED Innfinite Coloor+ ™ 3255 TRIM INFORMATION 1" Regress 1" Regress Bevel Finish Color area Flange Finish Color area 41⁄2"Ø 51⁄2"Ø HOUSING INFORMATION New Construction Universal Style Housing - NC Chicago Plenum - CP IC / Airtight - IC 7" 85/8" 11/8" 7" 11/8" 7" 13" 13" 185/8" (Plan View) 185/8" (Plan View) 22 /8" (Plan View) 221/8" (Plan View) 1 USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2015. USAI, LLC. All rights reserved. All designs protected by copyright. Revised 09/24/2015 WALL WASH ® BeveLED Innfinite Coloor+ ™ 3255 SPECIFICATIONS TRIM: 4-1/2” round aperture with a 1” regressed bevel and 1/2” flange, retained by two mounting clips. Die cast aluminum bevel is self flanged and available in white, statuary bronze, black, and metalized grey finishes. Also available in black or clear matte bevel with self finish or painted flange. Custom color flanges available (provide RAL#). CABLING: The DMX512 driver is provided with two twisted pair cabling for connection with communication controls. Data cables must be run in series between fixtures. Choose your preferred method of connection when specifying. To avoid signal transmission problems, a DMX link terminator should be used in the last fixture in a series. NOTE: Communication cables and AC power lines must not be run in the same conduit. TRIM LENS: Trim is shipped with micro diffusion wall wash lens. REFLECTOR: Proprietary precision injection molded wall wash reflector. ADJUSTMENT: 362° horizontal rotation, lockable. FIELD REPLACEABLE LIGHT ENGINE: Available in 1 lumen package: typical power draw is 23 input watts with 1025 delivered lumens. Maximum power draw is 32 input watts with up to 1225 delivered lumens. Engine is field replaceable through the aperture without tools. • RJ Cabling Option: fixture is provided with a DMX512 interface board inside the junction box with RJ45 jacks for use with CAT5 cable terminated with RJ45 connectors. For USAI Lighting fixtures with RJ45/CAT5 connections, the following ANSI/TIA/EIA-568 pin out standard is used. Link termination dip switch is provided at the connector board; no separate link termination device is required. See dimming compatibility pages for drawings and more details on this configuration. EMERGENCY: Emergency lighting battery pack with remote test switch is serviceable through aperture for NC housings. Bodine BSL26C provides 200mA for 90 minutes; delivers ~200-300 lumens. EMLW wet location option is available with B1 trim only and requires remote test switch. EM option is not available with IC or CP housings. MOUNTING: Butterfly brackets and adjustable nailer bars with integral nails provided. Nailer bars are extendible from 14” to 24” centers. HOUSING: Fabricated of 20 ga. galvanized steel with thru wire J-box, 4 in 4 out at min. 90°C, #12 AWG thru branch circuit wiring. MAXIMUM CEILING THICKNESS: As per drawings above. CEILING CUT OUT: 5-1/16” Ø LISTINGS: Dry/Damp. *Wet location option available with B1 trim only. NRTL/CSA-US tested to UL standards. IBEW union made. COLOR: BeveLED Infinite Color+ is capable of creating any color desired in the spectrum, from saturated blue, violet, green, yellow, orange, and red, to a wide variety of architectural whites. All color change is digitally controlled through the DMX interface of your choice. WARRANTY: 5 years NOTES: • Not for use in corrosive environment. • WR Cabling Option: no interface board is supplied; cables • Use of pressure washer voids warranty. must be spliced inside the junction box for connection. The PHOTOMETRICS: Consult factory or website for IES data cable used must meet the following requirements: THERMAL MANAGEMENT: Proprietary high performance files. Tested in accordance with IESNA LM79-2008. • type: shielded, 2-conductor twisted pair aluminum die cast heatsink for maximum LED life. Ambient • maximum capacitance between conductors: 30 pF/ft temperatures at fixture location should not exceed 40°C • maximum capacitance between conductor and during normal operation. shield: 55 pF/ft FIELD REPLACEABLE DIMMING DRIVER: Solid state • maximum resistance: 0.02 ohms/ft electronic constant current DMX512 8-bit driver with a • normal impedance: 100-140 ohms high power factor provided standard. Specify 120V or 277V. • conductive core: 24 AWG is recommended Driver complies with IEEE C62.41 surge protection. Specify If 3-wire data cables are preferred, we suggest a Belden DXM1M for 8-bit communication controls; specify DMX2M for 16-bit communication controls. All driver options require 9841 or equivalent cable which meets the specifications for remote device management (RDM) communication protocol EIA RS-485 applications. Do not use standard microphone cables: they cannot transmit DMX512 data reliably over for addressing. long distances. NOTE: DMX link termination device (by others) should be used on last fixture in line on a circuit to avoid signal loss. RATED LIFE: Based on IESNA LM80-2008 50,000 hours at 70% lumen maintenance (L70). • XL Cabling Option: fixture is provided with a DMX512 interface board on the junction box with standard 5-pin XLR5 jacks which accept XLR5 connectors for DMX communication. Any standard XLR cable can be used for this option. Link termination dip switch is provided at the connector board; no separate link termination device is required. NOTE: This cabling option requires above ceiling access. USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2015. USAI, LLC. All rights reserved. All designs protected by copyright. Revised 09/24/2015 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE DMX1M, DMX2M ® BeveLED Innfinite Coloor+ ™ DIMMING DRIVER WIRING SCHEMES: DMX1M: EldoLED DMX dimming with manual addressing, 8-bit (Dims down to 0%) DMX2M: EldoLED DMX dimming with manual addressing, 16-bit (Dims down to 0%) Choose from WR (splice connection), RJ (RJ45 jacks) and XL (XLR5 connectors) cabling options, and refer to corresponding wiring diagram below: 4 BLUE 3 DMX (-) GREEN/ WHITE 2 ORANGE DMX (+) 1 BLUE / WHITE 5 GREEN 6 BROWN / WHITE 7 ORANGE/WHITE BROWN 8 SHIELD CAT 5 CABLE RJ CABLING OPTION RJ-45 CONNECTORS DMX DATA IN DMX DATA OUT ON DMX+ ON DMXSHIELD TURN ON DIP SWITCH TO TERMINATE LAST FIXTURE ON DMX BUS OFF OFF LOAD LINE V+ DRIVER NEUTRAL V- GROUND WR OPTION DMX DATA IN DMX DATA OUT DMX+ BLUE DMX+ DMX- WHITE DMX- SHIELD- SHIELD • WR Cabling Option: no interface board is supplied; cables must be spliced inside the junction box for connection. The data cable used must meet the following requirements: • type: shielded, 2-conductor twisted pair • maximum capacitance between conductors: 30 pF/ft • maximum capacitance between conductor and shield: 55 pF/ft • maximum resistance: 0.02 ohms/ft • normal impedance: 100-140 ohms • conductive core: 24 AWG is recommended LOAD DRIVER LINE NEUTRAL V+ V+ V- V- If 3-wire data cables are preferred, we suggest a Belden 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Do not use standard microphone cables: they cannot transmit DMX512 data reliably over long distances. NOTE: DMX link termination device (by others) should be used on last fixture in line on a circuit to avoid signal loss. GROUND XL CABLING OPTION NOTE: This cabling option requires above ceiling access. 4.75" XLR CABLE 5 PIN XLR CONNECTORS MALE FEMALE DMX DATA IN 1.-10" DMX DATA OUT XLR CONNECTORS WHEN XLR5 IS SELECTED LEAVE CLEARANCE FOR J-BOX TO SLIDE TO APERTURE Off DMX+ On DMX- Termination 1-1/8" SHIELD TERMINATION LOAD TURN ON DIP SWITCH TO TERMINATE LAST FIXTURE ON DMX BUS V+ LINE DRIVER NEUTRAL V- GROUND USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2014. USAI, LLC. All rights reserved. All designs protected by copyright. I2-265 ® BeveLED Innfinite Coloor+ ™ DIMMING DRIVER WIRING SCHEMES: DIMMING DRIVER COMPATIBILITY SELECTION GUIDE DMX1M, DMX2M DMX MUST BE DAISY CHAINED IN SINGLE LINE CORRECT ! INCORRECT ! DRIVER DRIVER DRIVER DRIVER DRIVER DRIVER DRIVER DRIVER DRIVER DRIVER DRIVER NOTES FOR DRIVERS: 1. DMX signal cable must NOT be run in same conduit as high voltage AC power lines. 2. Fixtures must be daisy chained in one serial line using Data in and Data out 3. Maximum of 32 DMX devices on a single DMX bus 4. Maximum of 1600 ft serial communication link distance 5. To avoid signal loss, DMX signal terminator should be used on last fixture in line. For RJ and XL cabling options, this is provided through a dip-switch on the connector board. For WR cabling options, this device (120 ohm resistor) is provided by others. 6. For best results when using WR cabling option use communication data splices. 7. Default state for fixtures off. Luminaire will not light until DMX signal is received. USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2014. USAI, LLC. All rights reserved. All designs protected by copyright. I2-265