ADJUSTABLE 40° ® BeveLED Trimless Innfinite Coloor+ 3435 PROJECT INFORMATION ™ PROJECT DATE TYPE 1" Regress ™ BeveLED In nfifinnite Color+ Recessed Trimless Adjustable - Illuminate your space with any color available in the spectrum with BeveLED Infinate Color+. Tune the light from saturated blue, violet, green, yellow, orange, and red, to any of a wide variety of perfect architectural whites with DMX controls. Infinite opportunities abound for hospitality, entertainment, and cultural lighting applications. 1" Regress 1" Regress Bevel Finish Color (10, 13, 21, 28, RAL) 31⁄2" x 31⁄2" 41⁄2" x 41⁄2" HOW TO SPECIFY Ordering Example: Specify trim code and housing code to order: Example : 3435W - B1 - S - 10 - LSLA4 - 8432 - WRGB1 - 30KS - 35 - NC - 277V - DMX1M - RJ - CB27 TRIM ORDERING INFORMATION ™ BEVEL STYLE OPTION LENS – 3435 W Wet location 1 Square Trimless Adjustable 1 Wet location, use with – B1 1” Regress Bevel, Painted Die Cast In nfinite Color+ Spectrum B1 BEVEL FINISH – S 10 13 21 28 RAL S Solite (provided standard) B1 trims only. N/A with millwork. White Statuary Bronze Black Metalized Grey Custom Color (specify RAL #) Relative Output (W/nm) TRIM 3435 ___ AB1 1” Regress Bevel, S Solite blank for AB1 and Black Anodized Finish (provided (Leave AC1 Bevel Styles) standard) AC1 1” Regress Bevel, Clear Matte Anodized Finish HOUSING ORDERING INFORMATION HOUSING CODE LSLA4 LSLA4 WATTAGE – 8432 8432 32W LED, 1175 Lumen Maximum ENGINE CODE PRIMARY WHITE – WRGB1 – 30KS WRGB1 30KS 3000K, 80+ CRI REFLECTOR – 35 HOUSING TYPE – VOLTAGE – 35 35° beam NC New Construction CP Chicago Plenum 2 IC Insulation-Contact Rated / Airtight 2 0.8 0.6 0.4 0.2 0 400 450 500 550 600 650 700 750 wavelength (nm) Independently mix white light with color in any combination imaginable to create a uniquely personal light source. CABLING DIMMING DRIVER – 120V 277V 1 – ACCESSORIES – RJ RJ45 Jacks CB27 27” C-Channel Bars DMX1M EldoLED DMX 0.1% dimming, manual WR Splice Connection CB52 52” C-Channel Bars addressing using XL XLR5 Connectors 3 EML Emergency battery 4 RDM protocol, 8 bit EMLW Emergency battery, DMX2M EldoLED DMX 0.1% wet location 4 dimming, manual addressing using MLXX Millwork adapter RDM protocol, 16 bit XX=Specify Color (10, 13, 21, 28, RAL) Millwork not wet listed 2 For use with NC housings only. Provided with remote test switch. OPTICAL ACCESSORIES (Order separately) 3 Requires above ceiling access; N/A with IC or CP housings. 2 N/A with EM options. USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 AL20F Refer to optical AL30F accessories matrix on AL40F next page for resulting beamspreads when AL55F accessory lens is AL80F combined with 35° optics AS61F Clearly specify quantity in your order © 2015. USAI, LLC. All rights reserved. All designs protected by copyright. Revised 09/24/2015 ADJUSTABLE 40° BeveLED Innfinite Coloor+ Trimless ™ 3435 TRIM INFORMATION 1" Regress Optical Accessories Matrix if you want… and you have…. 35° 40° beam AL30F 45° beam AL40F 55° beam AL55F 60° beam AL80F 40x60° beam AS61F size F 1" Regress Bevel Finish Color 31⁄2" x 31⁄2" 41⁄2" x 41⁄2" HOUSING INFORMATION New Construction Universal Style Housing - NC IC / Airtight - IC 73/8" 5 81/2" /8"-1" 7" 7" 185/8" (Plan View) 185/8" (Plan View) 221/8" (Plan View) 221/8" (Plan View) USAI Lighting /8"-1" 13" 13" ® 5 www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2015. USAI, LLC. All rights reserved. All designs protected by copyright. Revised 09/24/2015 ADJUSTABLE 40° BeveLED Innfinite Coloor+ Trimless ™ 3435 SPECIFICATIONS TRIM: 4-1/2" square aperture with a 1" regressed bevel retained by two mounting clips. Die cast aluminum bevel is available in white, statuary bronze, black, and metalized grey finishes. Also available in black or clear matte bevel, with painted flange. Custom color flanges available (provide RAL#). TRIM LENS: Trim is shipped with integral solite lens standard. REFLECTOR: Interchangeable precision injection molded specular polycarbonate reflector optimized for 35° beam distribution. ADJUSTMENT: True hot aiming with center beam optics is adjustable, with a completely tool-less mechanism. 0°-40° lockable vertical tilt with 362° lockable rotation. FIELD REPLACEABLE LIGHT ENGINE: Available in 1 lumen package: typical power draw is 23 input watts with 975 delivered lumens. Maximum power draw is 32 input watts with up to 1175 delivered lumens. Engine is field replaceable through the aperture without tools. CABLING: The DMX512 driver is provided with two twisted pair cabling for connection with communication controls. Data cables must be run in series between fixtures. Choose your preferred method of connection when specifying. To avoid signal transmission problems, a DMX link terminator should be used in the last fixture in a series. NOTE: Communication cables and AC power lines must not be run in the same conduit. • RJ Cabling Option: fixture is provided with a DMX512 interface board inside the junction box with RJ45 jacks for use with CAT5 cable terminated with RJ45 connectors. For USAI Lighting fixtures with RJ45/CAT5 connections, the following ANSI/TIA/EIA-568 pin out standard is used. Link termination dip switch is provided at the connector board; no separate link termination device is required. See dimming compatibility pages for drawings and more details on this configuration. EMERGENCY: Emergency lighting battery pack with remote test switch is serviceable through aperture for NC housings. Bodine BSL26C provides 200mA for 90 minutes; delivers ~200-300 lumens. EMLW wet location option is available with B1 trim only and requires remote test switch. EM option is not available with IC or CP housings. MOUNTING: Butterfly brackets and adjustable nailer bars with integral nails provided. Nailer bars are extendible from 14” to 24” centers. HOUSING: All-Ways Square® (covered by US Pat. No: US 7,832,889) housing allows alignment of square aperture (up to 20° rotation) after housing installation and prior to finish ceiling installation. Fabricated of 20 ga. galvanized steel with thru wire J-box, 4 in 4 out at min. 90°C, #12 AWG thru branch circuit wiring. MAXIMUM CEILING THICKNESS: As per drawings above. ACCESSORY HOLDER: Snap in accessory holder shipped with fixture. Accepts “F” size lens, maximum 1. COLOR: BeveLED Infinite Color+ is capable of creating any color desired in the spectrum, from saturated blue, violet, green, yellow, orange, and red, to a wide variety of architectural whites. All color change is digitally controlled through the DMX interface of your choice. RATED LIFE: Based on IESNA LM80-2008 50,000 hours at 70% lumen maintenance (L70). THERMAL MANAGEMENT: Proprietary high performance aluminum die cast heatsink for maximum LED life. Ambient temperatures at fixture location should not exceed 40°C during normal operation. FIELD REPLACEABLE DIMMING DRIVER: Solid state electronic constant current DMX512 8-bit driver with a high power factor provided standard. Specify 120V or 277V. Driver complies with IEEE C62.41 surge protection. Specify DXM1M for 8-bit communication controls; specify DMX2M for 16-bit communication controls. All driver options require remote device management (RDM) communication protocol for addressing. • WR Cabling Option: no interface board is supplied; cables must be spliced inside the junction box for connection. The data cable used must meet the following requirements: • type: shielded, 2-conductor twisted pair • maximum capacitance between conductors: 30 pF/ft • maximum capacitance between conductor and shield: 55 pF/ft • maximum resistance: 0.02 ohms/ft • normal impedance: 100-140 ohms • conductive core: 24 AWG is recommended CEILING CUT OUT: Millwork: 4-13/16” x 4-13/16” All others: 5-1/2” x 5-1/2” LISTINGS: Dry/Damp. Wet location option available with B1 trim only. Millwork is not wet listed. NRTL/ CSA-US tested to UL standards. IBEW union made. WARRANTY: 5 years NOTES: • Not for use in corrosive environment. • Use of pressure washer voids warranty. • Not for use in acoustical ceiling tiles. If 3-wire data cables are preferred, we suggest a Belden 9841 or equivalent cable which meets the specifications for PHOTOMETRICS: Consult factory or website for IES EIA RS-485 applications. Do not use standard microphone files. Tested in accordance with IESNA LM79-2008. cables: they cannot transmit DMX512 data reliably over long distances. NOTE: DMX link termination device (by others) should be used on last fixture in line on a circuit to avoid signal loss. • XL Cabling Option: fixture is provided with a DMX512 interface board on the junction box with standard 5-pin XLR5 jacks which accept XLR5 connectors for DMX communication. Any standard XLR cable can be used for this option. Link termination dip switch is provided at the connector board; no separate link termination device is required. NOTE: This cabling option requires above ceiling access. USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2015. USAI, LLC. All rights reserved. All designs protected by copyright. Revised 09/24/2015 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE DMX1M, DMX2M ® BeveLED Innfinite Coloor+ ™ DIMMING DRIVER WIRING SCHEMES: DMX1M: EldoLED DMX dimming with manual addressing, 8-bit (Dims down to 0%) DMX2M: EldoLED DMX dimming with manual addressing, 16-bit (Dims down to 0%) Choose from WR (splice connection), RJ (RJ45 jacks) and XL (XLR5 connectors) cabling options, and refer to corresponding wiring diagram below: 4 BLUE 3 DMX (-) GREEN/ WHITE 2 ORANGE DMX (+) 1 BLUE / WHITE 5 GREEN 6 BROWN / WHITE 7 ORANGE/WHITE BROWN 8 SHIELD CAT 5 CABLE RJ CABLING OPTION RJ-45 CONNECTORS DMX DATA IN DMX DATA OUT ON DMX+ ON DMXSHIELD TURN ON DIP SWITCH TO TERMINATE LAST FIXTURE ON DMX BUS OFF OFF LOAD LINE V+ DRIVER NEUTRAL V- GROUND WR OPTION DMX DATA IN DMX DATA OUT DMX+ BLUE DMX+ DMX- WHITE DMX- SHIELD- SHIELD • WR Cabling Option: no interface board is supplied; cables must be spliced inside the junction box for connection. The data cable used must meet the following requirements: • type: shielded, 2-conductor twisted pair • maximum capacitance between conductors: 30 pF/ft • maximum capacitance between conductor and shield: 55 pF/ft • maximum resistance: 0.02 ohms/ft • normal impedance: 100-140 ohms • conductive core: 24 AWG is recommended LOAD DRIVER LINE NEUTRAL V+ V+ V- V- If 3-wire data cables are preferred, we suggest a Belden 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Do not use standard microphone cables: they cannot transmit DMX512 data reliably over long distances. NOTE: DMX link termination device (by others) should be used on last fixture in line on a circuit to avoid signal loss. GROUND XL CABLING OPTION NOTE: This cabling option requires above ceiling access. 4.75" XLR CABLE 5 PIN XLR CONNECTORS MALE FEMALE DMX DATA IN 1.-10" DMX DATA OUT XLR CONNECTORS WHEN XLR5 IS SELECTED LEAVE CLEARANCE FOR J-BOX TO SLIDE TO APERTURE Off DMX+ On DMX- Termination 1-1/8" SHIELD TERMINATION LOAD TURN ON DIP SWITCH TO TERMINATE LAST FIXTURE ON DMX BUS V+ LINE DRIVER NEUTRAL V- GROUND USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2014. USAI, LLC. All rights reserved. All designs protected by copyright. I2-265 ® BeveLED Innfinite Coloor+ ™ DIMMING DRIVER WIRING SCHEMES: DIMMING DRIVER COMPATIBILITY SELECTION GUIDE DMX1M, DMX2M DMX MUST BE DAISY CHAINED IN SINGLE LINE CORRECT ! INCORRECT ! DRIVER DRIVER DRIVER DRIVER DRIVER DRIVER DRIVER DRIVER DRIVER DRIVER DRIVER NOTES FOR DRIVERS: 1. DMX signal cable must NOT be run in same conduit as high voltage AC power lines. 2. Fixtures must be daisy chained in one serial line using Data in and Data out 3. Maximum of 32 DMX devices on a single DMX bus 4. Maximum of 1600 ft serial communication link distance 5. To avoid signal loss, DMX signal terminator should be used on last fixture in line. For RJ and XL cabling options, this is provided through a dip-switch on the connector board. For WR cabling options, this device (120 ohm resistor) is provided by others. 6. For best results when using WR cabling option use communication data splices. 7. Default state for fixtures off. Luminaire will not light until DMX signal is received. USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2014. USAI, LLC. All rights reserved. All designs protected by copyright. I2-265