BeveLED 3315 DOWNLIGHT ® Trimless Innfinite Coloor+ PROJECT INFORMATION ™ PROJECT DATE TYPE 1" Regress ™ BeveLED In nfifinnite Color+ Recessed Trimless Downlight - Illuminate your space with any color available in the spectrum with BeveLED Infinite Color+. Tune the light from saturated blue, violet, green, yellow, orange, and red, to any of a wide variety of perfect architectural whites with DMX512 controls. Infinite opportunities abound for hospitality, entertainment, and cultural lighting applications, or any other project requiring full color and white light flexibility. 1" Regress 1" Regress Bevel Finish Color 31⁄2" x 31⁄2" 41⁄2" x 41⁄2" HOW TO SPECIFY Ordering Example: Specify trim code and housing code to order: Example : 3315W - B1 - SF - 10 - LSLD4 - 9032 - WRGB1 - 30KS - 60 - NC - 277V - DMX1M - RJ - CB27 TRIM ORDERING INFORMATION 3315 3315 Square Trimless Downlight 1" Regress ™ BEVEL STYLE OPTION – ______ W EML – Wet location 1 Integral Emergency Test Switch 2 B1 1” Regress Bevel, Painted Die Cast SF Wet location, use with B1 trims only. N/A with millwork. In nfinite Color+ Spectrum B1 BEVEL FINISH – 10 13 21 28 RAL SF Solite Frosted (provided standard) SF Solite Frosted AB1 1” Regress Bevel, (provided Black Anodized Finish standard) AC1 1” Regress Bevel, Clear Matte Anodized Finish 1 2 LENS White Statuary Bronze Black Metalized Grey Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles) Relative Output (W/nm) TRIM 1 0.8 0.6 0.4 0.2 0 400 450 500 550 600 650 700 750 wavelength (nm) Independently mix white light with color in any combination imaginable to create a uniquely personal light source. Use with NC housing only HOUSING ORDERING INFORMATION HOUSING CODE WATTAGE LSLD4 – LSLD4 9032 9032 32W LED, 1375 Lumen Maximum ENGINE CODE PRIMARY WHITE – WRGB1 – 30KS WRGB1 30KS 3000K, 80+ CRI REFLECTOR – HOUSING TYPE – VOLTAGE – NC New Construction 60 60° beam 80 80° beam NCSM1 Narrow Width 1-1/4” ceiling max NCSM2 Narrow Width 2-1/4” ceiling max CP Chicago Plenum IC Insulation-Contact Rated / Airtight 120V 277V CABLING DIMMING DRIVER – ACCESSORIES – – RJ RJ45 Jacks CB27 27” C-Channel Bars DMX1M EldoLED DMX 0.1% dimming, manual WR Splice Connection CB52 52” C-Channel Bars addressing using XL XLR5 Connectors 3 EML Emergency battery 4 RDM protocol, 8 bit EMLW Emergency battery, DMX2M EldoLED DMX 0.1% wet location 4 dimming, manual addressing using MLXX Millwork adapter 5 RDM protocol, 16 bit XX=Specify Color (10, 13, 21, 28, RAL) Millwork not wet listed See emergency solutions chart for EM options with these housings 3 Requires above ceiling access; N/A with IC or CP housings. USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 4 For use with NC housings only. 5 ML not for use with NCSM1 housings. © 2015. USAI, LLC. All rights reserved. All designs protected by copyright. Revised 09/24/2015 DOWNLIGHT BeveLED Innfinite Coloor+ Trimless ™ 3315 TRIM INFORMATION 3315 Emergency Solutions EM Integral Remote Inverter Housing SERVICE Test Switch Test Switch By Others NCSM* N/A X NC Through aperture X NC Wet Location Through aperture X CP N/A X IC N/A X 1" Regress 31⁄2" x 31⁄2" EM fixtures that are provided with an integral test switch are shipped with a hole in the glass lens for access. Refer to “EMERGENCY SOLUTIONS” chart to find out which fixtures have an integral test switch. 41⁄2" x 41⁄2" HOUSING INFORMATION New Construction Universal Style Housing - NC Chicago Plenum - CP IC / Airtight - IC 73/8" 81/2" /8"-1" 5 7" /8"-1" 5 7" 13" 13" 185/8" (Plan View) 185/8" (Plan View) 22 /8" (Plan View) 221/8" (Plan View) 1 83/8" New Construction - Narrow Width 53/4" 43/4" X" NCSM1: 5/8" - 11/4" NCSM2:11/4" - 21/4" USAI Lighting ® www.usailighting.com info@usailighting.com 19" (Plan View) 22(Plan View) 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2015. USAI, LLC. All rights reserved. All designs protected by copyright. Revised 09/24/2015 DOWNLIGHT BeveLED Innfinite Coloor+ Trimless ™ 3315 SPECIFICATIONS TRIM: 4-1/2" square aperture with a 1" regressed bevel retained by two mounting clips. Die cast aluminum bevel is available in white, statuary bronze, black, and metalized grey finishes. Also available in black or clear matte bevel, with painted flange. Custom color flanges available (provide RAL#). CABLING: The DMX512 driver is provided with two twisted pair cabling for connection with communication controls. Data cables must be run in series between fixtures. Choose your preferred method of connection when specifying. To avoid signal transmission problems, a DMX link terminator should be used in the last fixture in a series. NOTE: Communication cables and AC power lines must not be run TRIM LENS: Trim is shipped with integral frosted solite lens in the same conduit. standard. • RJ Cabling Option: fixture is provided with a DMX512 REFLECTOR: Interchangeable precision injection molded interface board inside the junction box with RJ45 jacks for reflector optimized for 60° or 80° beam distribution. use with CAT5 cable terminated with RJ45 connectors. For USAI Lighting fixtures with RJ45/CAT5 connections, FIELD REPLACEABLE LIGHT ENGINE: Available in 1 lumen the following ANSI/TIA/EIA-568 pin out standard is used. package: typical power draw is 23 input watts with 1150 Link termination dip switch is provided at the connector delivered lumens. Maximum power draw is 32 input watts with up to 1375 delivered lumens. Engine is field replaceable board; no separate link termination device is required. See dimming compatibility pages for drawings and more details through the aperture without tools. on this configuration. COLOR: BeveLED Infinite Color+ is capable of creating any color desired in the spectrum, from saturated blue, violet, green, yellow, orange, and red, to a wide variety of architectural whites. All color change is digitally controlled through the DMX interface of your choice. RATED LIFE: Based on IESNA LM80-2008 50,000 hours at 70% lumen maintenance (L70). THERMAL MANAGEMENT: Proprietary high performance aluminum die cast heatsink for maximum LED life. Ambient temperatures at fixture location should not exceed 40°C during normal operation. • WR Cabling Option: no interface board is supplied; cables must be spliced inside the junction box for connection. The data cable used must meet the following requirements: • type: shielded, 2-conductor twisted pair • maximum capacitance between conductors: 30 pF/ft FIELD REPLACEABLE DIMMING DRIVER: Solid state • maximum capacitance between conductor and electronic constant current DMX512 8-bit driver with a shield: 55 pF/ft high power factor provided standard. Specify 120V or 277V. • maximum resistance: 0.02 ohms/ft Driver complies with IEEE C62.41 surge protection. Specify • normal impedance: 100-140 ohms DXM1M for 8-bit communication controls; specify DMX2M • conductive core: 24 AWG is recommended for 16-bit communication controls. All driver options require remote device management (RDM) communication protocol If 3-wire data cables are preferred, we suggest a Belden for addressing. 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Do not use standard microphone cables: they cannot transmit DMX512 data reliably over long distances. NOTE: DMX link termination device (by others) should be used on last fixture in line on a circuit to avoid signal loss. EMERGENCY: Fixtures provided with an integral test switch are provided with a hole in the glass lens as per the drawing above. Fixtures provided with a remote test switch are provided with a 24” lead length for location of the test switch. Fixtures that have no USAI EM option may be connected to an inverter (by others) for emergency lighting. See emergency solutions chart for more information on EM test switches and servicing. MOUNTING: Butterfly brackets and adjustable nailer bars with integral nails provided. Nailer bars are extendible from 14” to 24” centers. HOUSING: All-Ways Square® (covered by US Pat. No: US 7,832,889) housing allows alignment of square aperture (up to 20° rotation) after housing installation and prior to finish ceiling installation. Fabricated of 20 ga. galvanized steel with thru wire J-box, 4 in 4 out at min. 90°C, #12 AWG thru branch circuit wiring. NCSM housing can NOT be used with thru-branch circuit wiring. MAXIMUM CEILING THICKNESS: As per drawings above. CEILING CUT OUT: Millwork: 4-13/16” x 4-13/16” All others: 5-1/2” x 5-1/2” LISTINGS: Dry/Damp. Wet location option available with B1 trim only. Millwork is not wet listed. NRTL/ CSA-US tested to UL standards. IBEW union made. WARRANTY: 5 years NOTES: • Not for use in corrosive environment. • Use of pressure washer voids warranty. • Not for use in acoustical ceiling tiles. PHOTOMETRICS: Consult factory or website for IES files. Tested in accordance with IESNA LM79-2008. • XL Cabling Option: fixture is provided with a DMX512 interface board on the junction box with standard 5-pin XLR5 jacks which accept XLR5 connectors for DMX communication. Any standard XLR cable can be used for this option. Link termination dip switch is provided at the connector board; no separate link termination device is required. NOTE: This cabling option requires above ceiling access. USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2015. USAI, LLC. All rights reserved. All designs protected by copyright. Revised 09/24/2015 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE DMX1M, DMX2M ® BeveLED Innfinite Coloor+ ™ DIMMING DRIVER WIRING SCHEMES: DMX1M: EldoLED DMX dimming with manual addressing, 8-bit (Dims down to 0%) DMX2M: EldoLED DMX dimming with manual addressing, 16-bit (Dims down to 0%) Choose from WR (splice connection), RJ (RJ45 jacks) and XL (XLR5 connectors) cabling options, and refer to corresponding wiring diagram below: 4 BLUE 3 DMX (-) GREEN/ WHITE 2 ORANGE DMX (+) 1 BLUE / WHITE 5 GREEN 6 BROWN / WHITE 7 ORANGE/WHITE BROWN 8 SHIELD CAT 5 CABLE RJ CABLING OPTION RJ-45 CONNECTORS DMX DATA IN DMX DATA OUT ON DMX+ ON DMXSHIELD TURN ON DIP SWITCH TO TERMINATE LAST FIXTURE ON DMX BUS OFF OFF LOAD LINE V+ DRIVER NEUTRAL V- GROUND WR OPTION DMX DATA IN DMX DATA OUT DMX+ BLUE DMX+ DMX- WHITE DMX- SHIELD- SHIELD • WR Cabling Option: no interface board is supplied; cables must be spliced inside the junction box for connection. The data cable used must meet the following requirements: • type: shielded, 2-conductor twisted pair • maximum capacitance between conductors: 30 pF/ft • maximum capacitance between conductor and shield: 55 pF/ft • maximum resistance: 0.02 ohms/ft • normal impedance: 100-140 ohms • conductive core: 24 AWG is recommended LOAD DRIVER LINE NEUTRAL V+ V+ V- V- If 3-wire data cables are preferred, we suggest a Belden 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Do not use standard microphone cables: they cannot transmit DMX512 data reliably over long distances. NOTE: DMX link termination device (by others) should be used on last fixture in line on a circuit to avoid signal loss. GROUND XL CABLING OPTION NOTE: This cabling option requires above ceiling access. 4.75" XLR CABLE 5 PIN XLR CONNECTORS MALE FEMALE DMX DATA IN 1.-10" DMX DATA OUT XLR CONNECTORS WHEN XLR5 IS SELECTED LEAVE CLEARANCE FOR J-BOX TO SLIDE TO APERTURE Off DMX+ On DMX- Termination 1-1/8" SHIELD TERMINATION LOAD TURN ON DIP SWITCH TO TERMINATE LAST FIXTURE ON DMX BUS V+ LINE DRIVER NEUTRAL V- GROUND USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2014. USAI, LLC. All rights reserved. All designs protected by copyright. I2-265 ® BeveLED Innfinite Coloor+ ™ DIMMING DRIVER WIRING SCHEMES: DIMMING DRIVER COMPATIBILITY SELECTION GUIDE DMX1M, DMX2M DMX MUST BE DAISY CHAINED IN SINGLE LINE CORRECT ! INCORRECT ! DRIVER DRIVER DRIVER DRIVER DRIVER DRIVER DRIVER DRIVER DRIVER DRIVER DRIVER NOTES FOR DRIVERS: 1. DMX signal cable must NOT be run in same conduit as high voltage AC power lines. 2. Fixtures must be daisy chained in one serial line using Data in and Data out 3. Maximum of 32 DMX devices on a single DMX bus 4. Maximum of 1600 ft serial communication link distance 5. To avoid signal loss, DMX signal terminator should be used on last fixture in line. For RJ and XL cabling options, this is provided through a dip-switch on the connector board. For WR cabling options, this device (120 ohm resistor) is provided by others. 6. For best results when using WR cabling option use communication data splices. 7. Default state for fixtures off. Luminaire will not light until DMX signal is received. USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2014. USAI, LLC. All rights reserved. All designs protected by copyright. I2-265