SAF Tehnika CFQ-SD Indoor Unit Technical Reference page 1/5 December 2009 CFQ-SD Indoor Unit Overview The CFQ-SD IDU is a modular multiplexer component for the SAF CFQ microwave radiolink system. The CFQ-SD IDU supports diversified network interfaces, - optional plug-in modules allow customers to add network interfaces. Standard features: • Data interfaces E1 − 14 x E1, high-density Molex connector − 2 x E1, RJ-48C connector Scalable Ethernet − 2x 10/100 BaseTX, 25 – 100 Mbps, two RJ-45 ports • Voice ORW: 64 Kbps PCM voice channel • Single chip modem ASIC, • Integrated FEC, • Compact mechanical design, 1U rack unit allows 1+0, 1+1, 2+0, East-West configurations Other features: • Selectable Rates and Interfaces Software limit capacity option: − Up to 16 x E1 − 100baseTX/ethernet: Scalable 1-60Mbps PDH Options − Up to 16 x E1 − 100BaseTX/Ethernet: Scalable 1-100 Mbps Super PDH Options − Up to 32/42/58/63 x E1 Ethernet Options − 100 BaseTx/Ethernet: Scalable 1-155 Mbps (split into two FE ports, e.g. 100+55 Mbps) − 1000 BaseTx/Ethernet: Scalable 1-300 Mbps; 1-600 Mbps in 4+0 configuration; 1-900 Mbps in Wideband Modem+ODU configuration SDH Options − 1-2 x SDH STM-1 (electrical/optical interface) • Support for multiple configurations for both PDH and SDH 1+0, 1+1 protection • Hot Standby • East/West Repeater (2+0) • Selectable Spectral Efficiency of 0.8 to 6.25 bits/Hz (including FEC and spectral shaping effects) • QPSK, 16 – 256 QAM Modulation Link Provisioning • Powerful Trellis Coded Modulation concatenated with Reed-Solomon Error Correction • Built-in Adaptive Equalizer • Support of Voice Orderwire Channels • Support for Data Orderwire Channels − Up to 19.2 kbps asynchronous RS-232 − 64 kbps synchronous RS-422 • Peak output power: +20 dBm (will vary with ODU and frequency plan) • Receive Sensitivity: -70 dBm (or lower, depending on data rate/modulation/FEC/ODU) • Adaptive Power Control (ATCP) • Built-in Network Management System (NMS) • Device is controlled remotely via SAF NMS (NMS V3) • Consecutive Point ring architecture • Ring architecture can be secured for STM-1 connection, as well as for E1 and Ethernet connections • Built-in Bit Error Rate (BER) performance monitoring • Integrated Crosspoint switch: allows a total of 191 E1s to be mapped any-to-any between front-panel ports and RF link(s). • Optional STM-1 Mux/Demux: allows the CFQ-SD IDU to extract up to 63 E1 from an STM-1. In conjunction with an integrated Crosspoint Switch, up to 223 E1 can be mapped any-to-any between front-panel ports, STM-1, and RF link(s). Telephone: +371 7046840 • Fax: +371 7046809 Email: info@saftehnika.com • Internet: www.saftehnika.com SAF Tehnika A/S 24a Ganibu Dambis, Riga, Latvia SAF Tehnika CFQ-SD Indoor Unit Technical Reference page 2/5 December 2009 Specification summary Data modules Base module Standard Base 50 Mbps Link Capacity: 100 Mbps 155 Mbps Expanded Base 42E1 Base GigE Base Mini module STM-1 Optical mini module STM-1 Electrical mini module Optional modules 16E1 Expansion module 21E1 Expansion module 2xSTM-1 Electrical - 14 x E1, high-density Molex connector - 2 x E1, RJ-48C connector - Voice, Data ORW RJ-48C connectors - 100BaseTX, 1-100 Mbps, two RJ-45 ports - 14 x E1, high-density Molex connector - 2 x E1, RJ-48C connector - Voice, Data ORW RJ-48C connectors - 100BaseTX, 1-100 Mbps, two RJ-45 ports - 42 x E1, 3x high-density Molex connector - Voice, Data ORW RJ-48C connectors - 100BaseTX, 1-100 Mbps, two RJ-45 ports - 4x10/100/1000Base-T ports with RJ-45 connector - Ethernet SFP connector - 2 x E1, RJ-48C connector - Voice, Data ORW RJ-48C connectors STM-1, Single mode 1310 nm, SC Duplex Transceiver, Unconditionally eyesafe laser IEC 825/CDRH Class 1 Compliant STM-1, 2xBNC, ITU-T Rec. G.703, 75Ohm - 14 x E1, high-density Molex connector - 2 x E1, RJ-48C connector - 21 x E1, 2x high-density Molex connector Pass-through Two STM-1, 4xBNC, ITU-T Rec. G.703, 75Ohm ADM Dual ADM 2xSTM-1 Optical Pass-through Two STM-1 ports, Single mode 1310 nm, SC Duplex Transceiver, Unconditionally eyesafe laser IEC 825/CDRH ADM Class 1 Compliant Dual ADM 2xSTM-1 SFP Pass-through Two SFP slots ADM Dual ADM Auxiliary Connections Alarm Port 2 Form C (SPDT), 2 TTL Output, 4 TTL Input, DB-15HD ODU interface Intermediate Freq. Tx carrier: 350 MHz, Rx carrier: 140 MHz Range Emissions mask ETC 300 234, ETSI EN 301 216, FCC Part 101.111 Connector TNC (Female) Modulation 128QAM, modem features Adaptive Equalization FEC concatenated Reed-Solomon Coding with Trellis Coded Modulation, or Convolutional code Network Management SNMP Supports management via SNMP protocol (supports SNMP v1, v2 and v3 specifications) GUI and CLI Supports an onboard web-browser based GUI for control/status/provisioning, and menudriven Command Line Interface (CLI). Connector 10/100Base-TX (RJ-45) Voice Orderwire RJ-45 for PTT handset. We recommend using the Walker PTT-K Series w/EM-95 Transmitter Type. Auxiliary Data RS422 via RJ-45; 64 kbps Environmental requirements/Power IDU Temperature -5º to +55º C IDU Humidity 0 to 95%, non-condensing Altitude 4570 meters maximum (above sea level) DC Power -48 Volts ±10%, min. 90 W Telephone: +371 7046840 • Fax: +371 7046809 Email: info@saftehnika.com • Internet: www.saftehnika.com SAF Tehnika A/S 24a Ganibu Dambis, Riga, Latvia SAF Tehnika CFQ-SD Indoor Unit Technical Reference page 3/5 December 2009 Mechanical Dimensions CFQ-SD IDU Size (WxHxD) 445x44.5x238.5 mm CFQ-SD IDU Weight 3.4 kg IDU Mounting/Installation EIA Rack Mount 48.2 cm (19 inch), 1 rack unit (1U) Power Consumption Item IDU CFQ IDU 1+0 (with master module) CFQ IDU 1+1 (2xPSU, 2xModem) Modules Standard Master IO module Part Number Power Consumption 30 W 45 W Q0GM6E01 7.7 W STM-1 Optical Mini IO module Q0GMOM01 0.7 W STM-1 Electrical Mini IO module Q0GMEM01 0.7 W 16xE1 Expansion IO module Q0GM6X01 1.9 W Controller module Q0GMCM01 5.3 W Modem/IF module Q0GMMD01 9.3 W Power Supply Module (incl. chassis) Q0GMPS01 7.2 W Telephone: +371 7046840 • Fax: +371 7046809 Email: info@saftehnika.com • Internet: www.saftehnika.com SAF Tehnika A/S 24a Ganibu Dambis, Riga, Latvia SAF Tehnika CFQ-SD Indoor Unit Technical Reference page 4/5 December 2009 CFQ-SD-IDU module configurations Master IO Module Mini IO Expansion IO module Enhanced Gigabit Enhanced Standard Standard Eth. Gigabit 16E1+Eth 16E1+Eth 2E1 Ethernet 42E1 IO STM-1 CFQ IDU Types “SPDH” BASE 50 Mbits 16E1 2xEth ● Standard FE BASE 16E1 2xEth(10/100) Optional: 32E1 or 37E1, up to 3xSTM-1 ● Gigabit Eth BASE SFP, 4xGigE, 2E1 Optional: 18E1 or 23E1, up to 3xSTM-1 ● ● ● Enhanced Gigabit SFP, 4xGigE, 2E1 Optional: 18E1 or 23E1, up to 3xSTM-1 ◦ ◦ ◦ ◦ ◦ ◦ ● ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ● 42E1 BASE 42E1 2xEth(10/100) Optional: 58E1 or 63E1, up to 2xSTM-1 ● Overall • • • • • • • 2xSTM-1 ● “SPDH” BASE 100 Mbits FE 16E1 2xEth Optional: 32E1 or 37E1 Enhanced BASE STM-1, 16E1, 2xEth Optional: 32E1 or 37E1, up to 3xSTM-1 16E1 21E1 configuration: All 1+0 CFQ IDUs have: 1xManagement Board & 1xPSU & 1xmodem/IF All 1+1 CFQ IDUs have: 2xManagement Board & 2xPSU & 2xmodem/IF SD-IDU: Software Defined IDU Any STM-1 may have Electrical or Optical interface, or SFP for the 2xSTM-1 module Enhanced IDU supports up to 63E1 mux/demux via STM-1 (built-in ADM) 2xSTM-1 have pass-through or ADM, or dual ADM functionality Any IDU can be equipped with Standard or WideBand modem Telephone: +371 7046840 • Fax: +371 7046809 Email: info@saftehnika.com • Internet: www.saftehnika.com SAF Tehnika A/S 24a Ganibu Dambis, Riga, Latvia included, o optional SAF Tehnika CFQ-SD Indoor Unit Technical Reference page 5/5 December 2009 2xSTM-1 module overview and P/N Electrical Basic 2xSTM-1 pass through transparently forwards STM-1 streams Advanced 2xSTM-1 with built-in ADM Mux/Demux up to 63E1 per STM-1 1+1 Multiplex Section Protection (MSP) SDH Network Element (NE) and Performance monitoring at all levels of SDH hierarchy (G.826/G.828) High Capacity 2xSTM-1 with dual ADM future software upgrade: o STM-4 o specific SDH applications, o SDH regenerator SAF Tehnika A/S SFP Q0GM1E01 Q0GM1F01 Q0GM1S01 Q0GM2E01 Q0GM2F01 Q0GM2S01 Q0GM3E01 Q0GM3F01 Q0GM3S01 Telephone: +371 7046840 • Fax: +371 7046809 Email: info@saftehnika.com • Internet: www.saftehnika.com 24a Ganibu Dambis, Riga, Latvia Optical