NHPIC-926 Series 6" Sloped Economy IC Housing with Lensed Trims

advertisement
NHPIC-926 Series
6" Sloped Economy IC Housing
with Lensed Trims
Type
Lamp: 13W Magnetic 2-Pin Quad
NHP-926
NHP-926
13-18W Electronic 4-Pin Quad
13-18W Electronic 4-Pin Triple Biax
Project
PRODUCT DESCRIPTION
New construction housing for use in direct contact with insulation. Specification grade,
thermally protected with preinstalled adjustable bar hangers. For sloped ceiling applications
up to 22.5˚.
DIMENSIONS
Catalog No.
Lamp/Wattage
CONSTRUCTION
Plaster Frame
One piece 0.050 galvanized steel die cut frame, with attached 25 cubic inch junction box.
Maximum ceiling thickness 5/8".
7-3/4"
7-3/4"
Housing
0.040 steel housing adjusts to maximum ceiling thickness of 1-1/2"(39mm). Integral springs
bracket remains flush with housing. When using trims with torsion trim spring, fold inward 45˚
to accept torsion springs. Ceiling template provide.
7-7/8"
7-7/8"
EllipticalOpening:
Opening:6-3/4"
6-3/4"x x7-7/8"
7-7/8"
Elliptical
Bar Hangers
Two 13-3/4" to 24" adjustable bar hangers with nails are included on frame. Bar hangers are
parallel to junction box, but can be repositioned 90˚ perpendicular to junction box if desired.
Bar hanger foot contoured to align to bottom of construction joist. A T-Bar notch allow for easy
installation in a suspended ceiling.
BALLAST
Magnetic (M) - Residential
Standard Class P 120V magnetic ballast in normal power factor.
Sound Rated:
A
Starting Temperature: 32˚F (0˚C)
THD
<10%
Electronic (EL) - Universal
Thermally protected, electronic high power factor, single tap input voltage ranging from 110V277V, 0.225 Ampere - 0.974 Ampere, 50/60Hz with end of life protection. Class P, 18 Watts
maximum.
Starting Temperature
0˚ F – 18˚C
Operating Ambient Temperature
75˚C (Max)
Start Rating
>50,000
Power Factor
HPF
Flicker
<3%
THD
<10%
Catalog No.
NHPIC-926
Lamps
1
Wattage
Options
Ballast
Optional Emergency
Emergency back-up operates one lamp for a minimum of 90 minutes. Unit
includes battery, charger and test plate with indicator light. Emergency
ballasts are for dry locations.
For one lamp operation:
Add: (EM) Emergency ballast 650 Lumen,
(EM2) Emergency ballast up to 1300 Lumen.
Optional Accessories
FS
Fuse 2A
NRA-28
27" Flat Bar Hanger
Labels and Listings
UL Listed for Damp Location w/ Feed Through
Energy Star Rated (Electronic ballast only)
/
N T- 2 4 W
Lensed Trims
Dimming
Emergency
13
EL
DAS
M7
EM
18
M
D10
L51
EM2
MX1
L52
MX2
11-1/8"
9-1/2"
Optional Dimming
A variety of dimming ballast option are available in 13-18W. Each option
requires a controller that is compatible. Specify suffix.
DAS Advance Mark X, AMBI Star 120V (2Wire), Residential
D10 Universal Technologies 0-10V (4Wire), Universal
MX1 Advance Mark X 120V (2Wire), (Specify Wattage)
MX2 Advance Mark X 277V (2Wire), (Specify Wattage)
M7 Advance Mark 7 (4Wire), Universal
L51 Lutron SE 5% 120V (3Wire), (Specify Wattage & Voltage)
L52 Lutron SE 5% 277V (3Wire). (Specify Wattage & Voltage)
Lamp
- 13W Magnetic 2-Pin Quad lamp ordered separately.
- 13-18W Electronic 4-Pin Quad lamp ordered separately.
- 13-18W Electronic 4-Pin Triple Biax lamp ordered separately.
Housing - select one box from each column
Housing Length:
Housing Width:
Trim
Available in a variety of options including: Albalite, Fresnel, Drop Opal, and
Frosted Dome.
Socket
One compact fluorescent socket on a heavy duty curved steel bracket allows lamp adjustment.
Wing nuts lock desired settings.
Example: N H P I C - 9 2 6 / 1 8 E L
11-1/8"
11-1/8"
Cut out: 6-3/4" x 7-7/8"
Height: 7-3/4"
Junction Box
Prewired 25 cubic inch .064" thick galvanized steel, with seven 1/2" knockout, and snap on
covers. All leads are #18AWG wire, the ground wire is connected to the bottom, and quick
connectors are supplied on all leads. Through branch circuit wiring, (4-in, 4-out).
Create a complete fixture/trim catalog number:
9-1/2"
9-1/2"
Fuse
Catalog No.
FS
Ring
NT-22
B
G
NT-23
BZ
N
NT-24
C
W
CO
Finishes: B = Black, BZ = Brone, C = Chrome, CO = Copper, G = Gold, N = Natural Metal, W = White
6505 Gayhart St., Commerce, CA 90040
Phone: 800.686.6672 • FAX 800.500.9955
www.noralighting.com • e-mail: nora@noralighting.com
Specifications subject to change without notice. © 2008
926
LENSED TRIMS
NT-22 Albalite Lens
7-3/4"
9-1/2"
7-7/8"
Elliptical Opening: 6-3/4" x 7-7/8"
Ring:
Trim OD:
926
11-1/8"
1-1/2"
8-1/8"
8-1/8"
NT-23 Fresnel Lens
7-3/4"
9-1/2"
11-1/8"
7-7/8"
Elliptical Opening: 6-3/4" x 7-7/8"
Ring:
Trim OD:
926
1-1/2"
8-1/8"
8-1/8"
NT-24 Drop Opal Lens
7-3/4"
9-1/2"
11-1/8"
7-7/8"
Elliptical Opening: 6-3/4" x 7-7/8"
Ring:
Trim OD:
1-1/2"
8-1/8"
8-1/8"
6505 Gayhart St., Commerce, CA 90040
Phone: 800.686.6672 • FAX 800.500.9955
www.noralighting.com • e-mail: nora@noralighting.com
Specifications subject to change without notice. © 2008
NHPIC-926 Series
6" Sloped Economy IC Housing
with Baffle Trim
Type
Lamp: 13W Magnetic 2-Pin Quad
NHP-926
NHP-926
13-26W Electronic 4-Pin Quad
13-42W Electronic 4-Pin Triple Biax
Project
PRODUCT DESCRIPTION
New construction housing for use in direct contact with insulation. Specification grade,
thermally protected with preinstalled adjustable bar hangers. For sloped ceiling applications
up to 22.5˚.
DIMENSIONS
Catalog No.
Lamp/Wattage
CONSTRUCTION
Plaster Frame
One piece 0.050 galvanized steel die cut frame, with attached 25 cubic inch junction box.
Maximum ceiling thickness 5/8".
7-3/4"
7-3/4"
Housing
0.040 steel housing adjusts to maximum ceiling thickness of 1-1/2"(39mm). Integral springs
bracket remains flush with housing. When using trims with torsion trim spring, fold inward 45˚
to accept torsion springs. Ceiling template provide.
7-7/8"
7-7/8"
EllipticalOpening:
Opening:6-3/4"
6-3/4"x x7-7/8"
7-7/8"
Elliptical
Bar Hangers
Two 13-3/4" to 24" adjustable bar hangers with nails are included on frame. Bar hangers are
parallel to junction box, but can be repositioned 90˚ perpendicular to junction box if desired.
Bar hanger foot contoured to align to bottom of construction joist. A T-Bar notch allow for easy
installation in a suspended ceiling.
BALLAST
Magnetic (M) - Residential
Standard Class P 120V magnetic ballast in normal power factor.
Sound Rated:
A
Starting Temperature: 32˚F (0˚C)
THD
<10%
Electronic (EL) - Universal
Thermally protected, electronic high power factor, single tap input voltage ranging from 110V277V, 0.225 Ampere - 0.974 Ampere, 50/60Hz with end of life protection. Class P, 18 Watts
maximum.
Starting Temperature
0˚ F – 18˚C
Operating Ambient Temperature
75˚C (Max)
Start Rating
>50,000
Power Factor
HPF
Flicker
<3%
THD
<10%
Catalog No.
NHPIC-926
Lamps
1
Wattage
Options
Ballast
11-1/8"
9-1/2"
Optional Dimming
A variety of dimming ballast option are available in 13-18W. Each option
requires a controller that is compatible. Specify suffix.
DAS Advance Mark X, AMBI Star 120V (2Wire), Residential
D10 Universal Technologies 0-10V (4Wire), Universal
MX1 Advance Mark X 120V (2Wire), (Specify Wattage)
MX2 Advance Mark X 277V (2Wire), (Specify Wattage)
M7 Advance Mark 7 (4Wire), Universal
L51 Lutron SE 5% 120V (3Wire), (Specify Wattage & Voltage)
L52 Lutron SE 5% 277V (3Wire). (Specify Wattage & Voltage)
Lamp
- 13W Magnetic 2-Pin Quad lamp ordered separately.
- 13-18W Electronic 4-Pin Quad lamp ordered separately.
- 13-18W Electronic 4-Pin Triple Biax lamp ordered separately.
Housing - select one box from each column
Housing Length:
Housing Width:
Trim
Baffle is precision spun .040 aluminum with deep groves to reduce aperture
glare. Non-reflective matte black or white painted finishes.
Socket
One compact fluorescent socket on a heavy duty curved steel bracket allows lamp adjustment.
Wing nuts lock desired settings.
Example: N H P I C - 9 2 6 / 1 8 E L
11-1/8"
11-1/8"
Cut out: 6-3/4" x 7-7/8"
Height: 7-3/4"
Junction Box
Prewired 25 cubic inch .064" thick galvanized steel, with seven 1/2" knockout, and snap on
covers. All leads are #18AWG wire, the ground wire is connected to the bottom, and quick
connectors are supplied on all leads. Through branch circuit wiring, (4-in, 4-out).
Create a complete fixture/trim catalog number:
9-1/2"
9-1/2"
Optional Emergency
Emergency back-up operates one lamp for a minimum of 90 minutes. Unit
includes battery, charger and test plate with indicator light. Emergency
ballasts are for dry locations.
For one lamp operation:
Add: (EM) Emergency ballast 650 Lumen,
(EM2) Emergency ballast up to 1300 Lumen.
Optional Accessories
FS
Fuse 2A
NRA-28
27" Flat Bar Hanger
Labels and Listings
UL Listed for Damp Location w/ Feed Through
Energy Star Rated (Electronic ballast only)
/
NTP-614W
Baffle Trim
Dimming
Emergency
13
EL
DAS
M7
EM
18
M
D10
L51
EM2
MX1
L52
Fuse
Catalog No.
FS
Baffle
NTP-614
Ring
B
W
W
MX2
Baffle Finishes: B = Black, W = White
6505 Gayhart St., Commerce, CA 90040
Phone: 800.686.6672 • FAX 800.500.9955
www.noralighting.com • e-mail: nora@noralighting.com
Specifications subject to change without notice. © 2008
926
BAFFLE TRIM
NTP-614 Sloped Phenolic Stepped Baffle
7-3/4"
9-1/2"
7-7/8"
Elliptical Opening: 6-3/4" x 7-7/8"
Baffle:
Ring:
Trim OD:
11-1/8"
Black (B), White (W)
7/8"
7-7/8"
7-7/8"
6505 Gayhart St., Commerce, CA 90040
Phone: 800.686.6672 • FAX 800.500.9955
www.noralighting.com • e-mail: nora@noralighting.com
Specifications subject to change without notice. © 2008
Download