MVPP 1.0 MW / MVPP 1.25 MW / MVPP 1.44 MW / MVPP 1.5 MW / MVPP 1.5 MW / MVPP 1.6 MW Compact Medium Voltage Power Platform Reduced LCOE •Reduced balance of system costs with 1000 VDC design •Auxiliary HVAC not required, even in desert environments •Factory-integrated grid management, including reactive power control and LVRT Efficient Certified Turnkey •Best-in-class system efficiencies above 97 % peak •10 % additional power for continuous operation at ambient temperatures up to 25 °C •Low loss transformer engineered for PV application •Rigorous environmental testing •NRTL listing of entire platform •NEC 2011 compliant •Simplified shipping and installation process •Extensive service offerings and O&M support •Integrated AC disconnects, optional DC disconnects and various configuration options Compact Medium Voltage Power Platform Simplified solution means maximum ROI for utility-scale projects The Compact MV Power Platform is a turnkey power conversion solution for utility-scale PV plants. Designed for use with the Sunny Central CP-US central inverter line, this solution minimizes risk and maximizes energy production, providing 110 percent power output at temperatures up to 25 ºC. The Compact MV Power Platform is engineered for maximum ROI, offering reduced system costs, high reliability and best-in-class system efficiencies above 97 percent. Simple installation, easy data monitoring and superior service offerings make the Compact MV Power Platform the preferred choice for large scale projects in North America. Compact Medium Voltage Power Platform Technical Data Input (DC) MPP voltage range at 25 °C (77 °F) / at 50 °C (122 °F) at 60Hz Max. DC voltage Max. DC input current Number of independent MPP inputs Number of fused DC inputs Output (AC) Nominal AC power Maximum AC power Nominal AC voltage options Grid frequency Power factor (adjustable) Transformer vector group Transformer no load taps Transformer cooling type Power Consumption Internal consumption in operation (inverter + MV-transformer) ⁴ Standby consumption (inverter + MV-transformer) Integrated control power supply / external control power supply External auxiliary supply voltage Efficiency Max. efficiency / CEC efficiency inverter MVPP System Efficiency Peak Protection Rating and Ambient Conditions Protection rating Operation temperature range @ nominal power Storage temperature standard / low temperature option (@Pnom) Relative humidity Snow load, maximum (psf) Wind load, maximum (mph) Fresh air consumption (CFM) Max. altitude above MSL Design lifetime (years) Compliance and Certificates Seismic rating according UBC sec. 1632 and IBC sec. 1613 ⁵ NEC 2011 / OSHA 1910 NRTL Listing: UL1741, UL857, UL891, NFPA79 PE stamped Structural Calculations Features DC Disconnect Unit / AC Disconnect Tracker Motor Supply (10kVA@460VAC / 10kVA@480VAC / 20kVA@480VAC / 30kVA@480VAC) Auxiliary Services Power (none / 2kVA / 7.5kVA) Customer SCADA system Accommodation Convenience Receptacles Transformer alarm contacts: (Temp / Pressure / Liquid level / Analog Temp) Transformer oil containment Monitoring (extended I/O): 4 DI, 3 AI Delivery Terms: FCA-Origin Platform Design W / H / D (Platform including External Disconnect Units) Weight (Platform including External Disconnect Units) W / H / D (Platform excluding External Disconnect Units) Weight (Platform excluding External Disconnect Units) ● Standard features ○ Optional features — Not available Type designation SUNNY CENTRAL CP-US CoMVPP 1.0 MW SUNNY CENTRAL CP-US CoMVPP 1.25 MW 430 V … 820 V / 430 V … 820 V ² 1000 V 2500 A 2 18 500 V … 820 V / 500 V … 820 V ² 1000 V 2700 A 2 18 1000 kVA @ 50 °C (122 °F) 1260 kVA @ 50 °C (122 °F) 1100 kVA @ 25 °C (77 °F) 1400 kVA @ 25 °C (77 °F) 12.47 kV; 13.8 kV; 20.6 kV; 24.9 kV; 27.6 kV; 34.5 kV 60 Hz 60 Hz 0.8 leading ... 0.8 lagging 0.8 leading ... 0.8 lagging Dy1y1 Dy1y1 ±2.5 % & ±5.0 % ±2.5 % & ±5.0 % KNAN KNAN < 3800 VA + < 10.1 kVA < 300 VA + < 1100 VA ●/○ 480 V; 600 V < 3800 VA + < 12.4 kVA < 300 VA + < 1350 VA ●/○ 480 V; 600 V 98.10 % / 97.50 % > 97 % 98.50 % / 98.00 % > 97.5 % NEMA 3R -25 °C (-13 °F) ... 50 °C (+122 °F) -25 °C (-13 °F) ... 60 °C (+140 °F) / -40 °C (-40 °F) ... 60 °C (+140 °F) 15 % ... 95 % 40 110 3532 6562 ft > 20 NEMA 3R -25 °C (-13 °F) ... 50 °C (+122 °F) -25 °C (-13 °F) ... 60 °C (+140 °F) / -40 °C (-40 °F) ... 60 °C (+140 °F) 15 % ... 95 % 40 110 3532 6562 ft > 20 ●/● ● ● Site class D, Ss =2.25g, S1=1.24g ●/● ● ● ○/● ○/● ○/○/○/○ ○/○/○/○ ●/○/○ ●/○/○ 864 / 762 / 305 mm (34 / 30 / 12 inch), supply: 120 V / 60 Hz / max. 250 W 2 x 120 V / max. 250 W each ● / ○ / ○ /○ ● / ○ / ○ /○ ○ ○ ● ○ ○ ● 9296 / 2591 / 2591 mm (366 / 102 / 102 inch) < 17690 kg (< 39000 lb) < 17690 kg (< 39000 lb) 7696/ 2591 / 2591 mm (303 / 102 / 102 inch) < 15876 kg (< 35000 lb) < 15876 kg (< 35000 lb) MVPP 1.0 MW MVPP 1.25 MW 1) @ 1.05 UAC, nom and cos φ = 1 2) @ 1.00 UAC, nom and cos φ = 1 3) Standard: 1000 V DC, optional 1100 V DC with a start-up < 1000 V DC 4) Not including platform auxiliary service loads 5) Pier height 3 ft max. SUNNY CENTRAL CP-US CoMVPP 1.44 MW SUNNY CENTRAL CP-US CoMVPP 1.5 MW SUNNY CENTRAL CP-US CoMVPP 1.6 MW 525 V … 820 V / 525 V … 820 V ² 1000 V 3200 A 2 18 545 V … 820 V / 545 V … 820 V ² 1000 V 3200 A 2 18 570 V … 820 V / 570 V … 820 V ² 1000 V 3200 A 2 18 1440 kVA @ 50 °C (122 °F) 1584 kVA @ 25 °C (77 °F) 1600 kVA @ 50 °C (122 °F) 1760 kVA @ 25 °C (77 °F) KNAN 1500 kVA @ 50 °C (122 °F) 1650 kVA @ 25 °C (77 °F) 12.47 kV; 13.8 kV; 20.6 kV; 24.9 kV; 27.6 kV; 34.5 kV 60 Hz 0.8 leading ... 0.8 lagging Dy1y1 -5.0 %; -2.5 %; +2.5 %; +5.0 %; +7.5 %; +10.0 % KNAN < 3800 VA + < 14.6 kVA < 300 VA + < 1600 VA ●/○ 480 V; 600 V < 3800 VA + < 14.6 kVA < 300 VA + < 1600 VA ●/○ 480 V; 600 V < 3800 VA + < 15.7 kVA < 300 VA + < 1700 VA ●/○ 480 V; 600 V 98.60 % / 98.00 % > 97.5 % 98.60 % / 98.00 % > 97.5 % 98.70 % / 98.50 % > 97.5 % NEMA 3R -25 °C (-13 °F) ... 50 °C (+122 °F) -25 °C (-13 °F) ... 60 °C (+140 °F) / -40 °C (-40 °F) ... 60 °C (+140 °F) 15 % ... 95 % 40 110 3532 6562 ft > 20 NEMA 3R -25 °C (-13 °F) ... 50 °C (+122 °F) -25 °C (-13 °F) ... 60 °C (+140 °F) / -40 °C (-40 °F) ... 60 °C (+140 °F) 15 % ... 95 % 40 110 3532 6562 ft > 20 NEMA 3R -25 °C (-13 °F) ... 50 °C (+122 °F) -25 °C (-13 °F) ... 60 °C (+140 °F) / -40 °C (-40 °F) ... 60 °C (+140 °F) 15 % ... 95 % 40 110 3532 6562 ft > 20 ●/● ● ● Site class D, Ss =2.25g, S1=1.24g ●/● ● ● ●/● ● ● ○/● ○/● ○/● ○/○/○/○ ○/○/○/○ ○/○/○/○ 60 Hz 0.8 leading ... 0.8 lagging Dy1y1 60 Hz 0.8 leading ... 0.8 lagging Dy1y1 KNAN ●/○/○ ●/○/○ ●/○/○ 864 / 762 / 305 mm (34 / 30 / 12 inch), supply: 120 V / 60 Hz / max. 250 W 2 x 120 V / max. 250 W each ● / ○ / ○ /○ ● / ○ / ○ /○ ● / ○ / ○ /○ ○ ○ ● ○ ○ ● < 15876 kg (< 35000 lb) 9296 / 2591 / 2591 mm (366 / 102 / 102 inch) < 17690 kg (< 39000 lb) 7696/ 2591 / 2591 mm (303 / 102 / 102 inch) < 15876 kg (< 35000 lb) MVPP 1.44 MW MVPP 1.5 MW < 17690 kg (< 39000 lb) ○ ○ ● < 17690 kg (< 39000 lb) < 15876 kg (< 35000 lb) MVPP 1.6 MW The SMA Advantage Maximized energy yield Serviceability LCOE reduction Quality Your levelized cost of energy is significantly reduced through SMA’s superior energy harvest, reliability, acceleration of installation velocity, and world-renowned bankability. Grid Integration At the heart of every Compact MV Power Platform are SMA’s award-winning Sunny Central inverters, delivering all of the grid management functionality demanded. www.SMA-Solar.com Engineered for ease of transport, installation, and maintenance, and backed by the best service capabilities in the industry. Another industry first, the SMA Compact MV Power Platform is a suite of factory assembled and tested pre-engineered solutions carrying an NRTL listing. System-oriented Design Designed as a cost-effective, turn-key solution from the DC feeders, to the medium voltage collection loop, the Compact MV Power Platform is the ideal building block for today’s utility scale PV plants. SMA Solar Technology COMPACT MVPP-DEN134011 SMA and Sunny Central are registered trademarks of SMA Solar Technology AG. Printed on FSC-certified paper. All products and services described as well as technical data are subject to change, even for reasons of country-specific deviations, at any time without notice. SMA assumes no liability for errors or omissions. For current information, see SMA-SOLAR.com Best-in-class system efficiency, low self consumption, and matched components result in increased energy yield, speeding your return on investment.