FUMEX
Upblast Roof Exhausters
Moving Your Way
TABLE OF CONTENTS
Introduction, Certifications & Listings
3
Features & Benefits
4
Options & Accessories
5
Motor Availability
8
Direct Drive Dimensional & Performance Data 10
Belt Drive Dimensional & Performance Data 13
Engineering Specifications 29
BULLETIN FX14
PennBarry
|
Your Single Source for Commercial & Industrial Supply & Exhaust Fans
|
www.pennbarry.com
Fumex | FX
INTRODUCTION
Fumex Series of Centrifugal Fans
Fumex centrifugal fans are designed for medium to high
pressure applications. They can be either roof or wall mounted.
While suitable for general ventilation, Fumex fans are specifically
designed to discharge contaminated or grease-laden air or
fumes up and away from building surfaces. The optional “Fatrap”
(UL762) restaurant grease exhaust configuration (see Fatrap
Configuration) makes Fumex fans particularly suited for all food
service applications and chemical fume hoods. The optional
heat and smoke removal configuration (see Smoke Removal)
makes Fumex fans particularly suited for heat and smoke control
systems. The optional high wind construction makes Fumex
Fans particularly suited for high wind hurricane zones. Fumex
fans are available in a range of capacities.
Belt Drive Fumex
with Fatrap option
(left) and Direct Drive
Fumex (below).
Fumex fans feature a weather-resistant seamless spun
aluminum housing which provides ample drainage and works
in conjunction with a patented wheel design and deeply spun
inlets to provide smooth quiet airflow through the ventilator. The
centrifugal wheels are aluminum, non-overloading, backward
inclined, robotically welded, and dynamically balanced.
Fumex Direct Drive Series
Model: FX (V/S/R/Q/Q1/Q2)
• Static pressure up to 1.5 in. wg.
• Flow capacity up to 4,489 CFM.
• Fatrap (FT) option available on sizes 13, 16, and 18.
• High Wind Construction (-HW) option available.
Fumex Standard Duty Belt Drive Series
Model: FX (B)
• Static pressure up to 2.5 in. wg.
• Flow capacity up to 21,511 CFM.
• Fatrap (FT) option available.
• Heat & Smoke Removal (-HS) option available.
• High Wind Construction (-HW) option available.
Fumex High Pressure Belt Drive Series
Model: FX (BH)
• Static pressure up to 4 in. wg.
• Flow capacity up to 9,920 CFM.
• Fatrap (FT) option available.
• Heat & Smoke Removal (-HS) option available.
• High Wind Construction (-HW) option available.
Fumex High Capacity Belt Drive Series
Model: FMX (B)
©PENNBARRY 2014
• Static pressure up to 1.5 in. wg.
• Flow capacity up to 25,035 CFM.
www.PennBarry.com | Moving Your Way
CERTIFICATIONS & LISTINGS
Fumex Direct & Belt Drive Fans
PennBarry certifies that the Fumex direct drive
and belt drive models FX, FXB, FXBH, and
FXBHFT shown herein are licensed to bear the
AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
with AMCA Publication 211 and Publication 311
and comply with the requirements of the AMCA
Certified Ratings Program.
Fumex High Capacity Belt Drive Fans
PennBarry certifies that the Fumex belt drive model
FMXB shown herein is licensed to bear the AMCA
Seal. The ratings shown are based on tests and
procedures performed in accordance with AMCA
Publication 211 and comply with the requirements
of the AMCA Certified Ratings Program.
UL and cUL Certification
Fumex fans carry the UL label, UL 705 (ZACT),
File #E28413. Fumex fans with the “Fatrap” option
are UL 762 (YZHW) listed under file #MH10684.
Fumex fans with the heat and smoke removal
option are UL listed under file #MH19473.
3
Fumex | FX
FEATURES & BENEFITS
Motor Selection
Vibration Isolators
Reverse Venturi
Both direct drive and belt drive models are
available with a wide range of voltages
and enclosures (see Motor Selection for a
complete listing). Standard belt drive Open
Drip Proof (ODP) ball bearing motors are
selected using a conservative portion of
the NEMA service factor. Standard direct
drive ODP motors have Class B insulation
and internal overload protection. Overload
protection is available as an option on
belt drive models. Each size is carefully
engineered to match the motor to the
wheel capacity.
Multidirectional, rubber-in-shear vibration
isolators mitigate residual vibration
transmission from the unit to the building.
Reverse venturi reduces
turbulence and improves
distribution of the air as
it enters the wheel inlet
and is “captured” by the
blades.
Internal Wiring
All direct and belt drive models with ODP
motors feature a polarized disconnect
plug which is factory wired from the
motor to the junction box. This provides
a positive method of electric shut-off as
required by most codes without requiring
the traditional disconnect switch. (See
Options & Accessories for optional NEMA
wiring and disconnect devices.)
Sound Performance
Fumex units deliver outstanding air
performance with minimal noise and
have the lowest AMCA licensed sound
performance in the industry.
Curb Caps (Base)
Curb caps for direct drive and standard
duty belt drive models are available in
galvanized steel (standard) or aluminum
(optional). Curb caps for high capacity
belt drive models are available only in
aluminum. All curb caps have fully welded
corners and are pre-punched to ensure a
leak-tight and easy installation.
Forced Motor Cooling
Motors and drive components are
located out of the airstream in a separate
compartment. A cooling tube between
the motor dome and discharge apron
enables fresh air to be drawn into the
motor housing during fan operation. This
positive cooling promotes longer life for
motor and drive components.
Easy Maintenance Access
4
Durable housings of spun aluminum
have a high strength-to-weight ratio and
incorporate a rolled bead for additional
strength. There are no welds to break or
seams to leak. The heavy-gauge motor
mounting platform provides positive
rigidity between all components of the
power train assembly.
Internal Bracing
Tri-Strut™ supports transfer the weight
of the motor mounting platform directly to
the curb mounting surface. The aluminum
spun housing, therefore, is not used to
support any weight. For grease laden
applications, there is less surface for
grease build-up during normal operation.
Solid Steel Shafts
Sized so the first critical speed is a
minimum of 130% of maximum cataloged
operating speed, shafts are precision
ground, and polished.
Self-Aligning Bearings
Heavy-duty bearings are sized for a
minimum L50 life in excess of 200,000
hours of operation. 100% factory tested,
they are designed for air handling
applications.
Drives and Belts
Pulleys are pre-set to the specified
RPM. Cast iron variable pitch pulleys are
adjustable, allowing for field balancing
based on actual field conditions. All
pulleys are sized for at least 150% of the
driven horsepower.
Conduit
Both direct and belt drive units include
a large 1” nominal conduit chase (not
available on heat and smoke removal
units; wiring is run via the cooling tubes)
for easy installation of wiring from the
motor dome to below the curb cap. Fatrap
units are factory wired to an external
NEMA 3R junction box.
Wheels
Fumex fans offer patented wheel designs.
Carefully matched, highly-tooled venturis
enhance the performance of these
backward inclined and non-overloading
centrifugal wheels. Made of advanced
aluminum alloys, the various wheel
components provide superior strength
and durability, as well as spark resistant
construction. The heat and smoke removal
configuration utilizes steel construction.
Silent Wheel (Direct Drive)
• Blades’ highly curved
leading edge provide
unsurpassed
low
sound
numbers
with
excellent
air
performance.
• Back plate and inlet are stamped for
consistency, plus dynamic balancing
assure smooth, vibration-free operation.
• Riveted or riveted and welded
construction
ensure
superior
dependability over other wheel designs.
Standard Duty, All Welded Wheel
(Standard Duty & High Pressure Belt Drive)
• Blades are curved for improved air
performance while increasing their
strength and rigidity.
• Back plate and inlet are stamped for
consistency. They include a perimeter
rim which enhances strength and
improves balancing.
• Wheel assembly is robotically welded
to provide extremely durable and
consistent performance.
• Wheel
is
dynamically
balanced.
Balancing weights are mechanically
attached to the inside of the rims of
both the back plate and wheel inlet.
This allows a precise placement of the
weights anywhere within a full 360º
range on two separate planes, without
the possibility of detachment.
www.PennBarry.com | Moving Your Way
©PENNBARRY 2014
By removing the fasteners, the motor
dome lifts off for complete access to all
the drive components.
Structural Integrity
Fumex | FX
OPTIONS & ACCESSORIES
Finishes
Internal Wiring
Speed Controllers
Coatings such as Polyester Powder Coat,
Epoxy Powder Coat, Phenolic Epoxy
Powder Coat, and others are available.
See the coatings brochure for details.
NEMA 3R wiring is available for both
direct and belt drive models.
The Lek-TrolTM controller
allows adjustment in speed
to a maximum of 50%
reduction, which results in
a very cost effective means
for system balancing. The
device can be located under the fan dome
to prevent unauthorized tampering or
on the wall for ease of operation by the
building occupants. (Available on direct
drive units with ODP motors and some
select TE motors. See reference table
under Motor Availability)
The 12” high mounting pedestal,
available in aluminum or galvanized steel,
incorporates a removable access panel
for easy inspection and service of motor
operated back draft dampers. It provides
solid ventilator support and a weather
resistant seal that does not injure or
disturb flashing. This item should not be
used with Fatrap units.
Back draft dampers are available for
either gravity or motorized operation
(motor kit optional). Dampers feature
square galvanized steel frame, multi-leaf,
roll formed aluminum blades with nylon
bearings. Back draft dampers should not
be used when venting kitchen hoods.
NFPA 96 installations do not allow the use
of dampers. The requirements of local
codes must be reviewed to determine if
there are any conflicts.
Hinged Sub-Base
Safety Disconnect Switch
Mounting Pedestal
Hinged sub-bases provide access to the
curb well for damper service or clean
out for grease applications. Constructed
with a rust proof hinge arrangement and
low height (3 ½”) the assembly is easily
manipulated and reduces the impact on
overall installation height. This accessory
is available for use with most all models for
either factory built or existing roof curbs.
Floating Hinge Kit
A floating hinge kit is also available for
field installation. This assembly connects
the exhauster directly to the roof curb and
provides the same level of access as the
hinged sub-base.
Fumex
Base
Floating Hinge Plate
Back Plate
(Inside Curb/Pedestal)
Ventilator
Curb/Pedestal
Bushing
Aluminum Bird & Insect Screen
©PENNBARRY 2014
Backdraft Dampers
Bird screens are available for all direct
and belt drive models. An aluminum
insect screen with a smaller mesh than
the standard bird screen is also available.
However, please note that NFPA 96
installations do not allow the use of bird or
insect screens. The requirements of local
codes must be reviewed to determine if
there are any conflicts.
www.PennBarry.com | Moving Your Way
Safety disconnect switches
are available to allow
positive electrical shutoff and safety. Switches
are factory mounted when
factory wiring is requested.
Wiring is only run from the motor to the
junction box. (Factory wiring of explosion
proof applications is not available.) A
wide range of NEMA rated enclosures
with disconnect switches are available
for indoor, outdoor, and explosion proof
installations. Disconnects are to be field
wired by a licensed electrician.
Firestat Switch
Firestat switch automatically
disconnects the unit when
the temperature of the air
being exhausted exceeds a
preset rating.
Time-Delay Switch
(Selected
direct
drive
models only) The Airminder
Model AM12 switch is a
UL recognized and CSA
certified time-delay relay
that operates both the fan
and room light to ventilate
an area even after the
occupants depart. In the “On” position,
the Airminder turns the light and fan on
immediately. In the “Off” position, the
light goes off immediately and the fan is
in operation for a period of time as preset
from 1 to 60 minutes. Suitable only for 1/3
HP maximum at 120/1/60.
Automatic Belt Tensioner
The factory mounted Automatic Belt
Tensioner accessory eliminates the need
for re-tensioning the belt after start-up. It
is constructed from 10 gage galvanized
steel and incorporates five torsion
springs to automatically position the
motor and maintain proper belt tension.
Additional benefits include reduced
belt and pulley wear and simplified belt
replacement without tools. The Automatic
Belt Tensioner is available for Fumex
models FX08B, FX10B, FX12BH, FX13B,
FX13BHFT and FX14B with 1/4, 1/2, 3/4,
and 1 HP ODP motors. It can also be
used with 1.5 HP, 3-phase ODP motors.
Spark Resistant Construction
AMCA ‘B’ construction is available as
standard construction on direct drive units
and as an option on belt drive units (not
available on heat and smoke removal
units). If required, an explosion proof motor
and disconnect may be selected as options.
Wall Mounting
This option is provided as a separate
product line, whose models include
a “W” prefix. Product line includes
models up to size 24, motors up to
2HP, and round bases (not available
on heat and smoke removal units).
Prefabricated Curb
A variety of sizes of prefabricated roof
curbs are available. Galvanized steel
unibeam curbs are the most popular.
For a complete listing of all curb types
and sizes available, see the latest
PennBarry Ventilation Curb brochure.
Please note that NFPA 96 installations
require a specific curb height. See Fatrap
configuration on the next page.
5
Fumex | FX
OPTIONS & ACCESSORIES
Fatrap Configuration
Fumex Curb
Fatrap configured fans are ideal for use in commercial kitchens
over grilles, charcoal broilers, deep fat fryers, steam tables,
ranges, dishwashers, and other appliances. Fumex fans are
specially configured for food service applications with the addition
of a group of accessories that either meets a requirement or
eases installation requirements according to NFPA 96. NFPA
96 “Standard for Ventilation Control and Fire Protection of
Commercial Cooking Operations” is the generally recognized
authority nationwide for restaurant installation requirements.
However, local codes may vary.
T (sq.)
1 1/2"
H
18" MIN.
Vented Self
Standard
Flashing
w/Cant
Ro (sq.)
A (sq.)
Included in the units are the following.
Damper
Size
SQ
Galv.
Steel
Gauge
9
8.75
18
11.5
11.25
18
11.5
11.25
18
25
11.5
11.25
18
19
27
16
15.75
18
27
35
20
19.75
18
24.75
23.25
31.25
16
15.75
18
FX12BH
24.75
23.25
31.25
16
15.75
18
FX13BHFT
24.75
23.25
31.25
16
15.75
18
FX16B and FX18B
28.5
27
35
20
19.75
18
FX18BH
28.5
27
35
20
19.75
18
FX24B
33.5
32
40
25
24.75
18
FX24BH
33.5
32
40
25
24.75
18
FX27B and FX30B
36.5
35
43
28
27.75
18
FX36B
44.5
43
51
36
35.5
18
FMX50B
59
57.5
65.5
50
49.5
18
E(4)
SQ
T(2)
SQ
A
SQ
FX08S/R
18.5
17
25
FX10S/R
18.5
17
25
FX11V/S/R/Q
18.5
17
25
FX13V/S/R/Q
18.5
17
FX16V/S/R/Q1/Q2
20.5
FX18V
28.5
FX08B to FX14B
Model
Ro(3)
SQ
Standard heights “H” are 8”, 12”, and 18” including wood nailer. ”T” dimension of
curb is 1 1/2” less than the dimension of inside base of fan (“E”). “Ro” refers to
Roof Opening. “E” dimension is inside base of fan. For FT (Fatrap) units, curbs are
cantless, 18” high and optionally vented.
Exploded View
SAFETY
DISCONNECT
SWITCH
ALUMINUM
BIRD AND INSECT
SCREEN
HINGED
SUB-BASE
PREFABRICATED
CURB
• UL 762 Listing: Fatrap configured Fumex fans are listed
at 400°F — 100°F higher than UL requirements. The high
temperature rating is the result of the fan’s highly efficient
forced motor cooling capability. Three direct drive (sizes 13 –
18) and all belt drive models are listed.
• Pre-wired Junction Box: A weather-proof junction box
is factory wired and mounted to the housing exterior. An
appropriately sized disconnect switch is commonly selected as
an additional option. These items meet the code requirements
for positive electric shut-off.
• Grease Collector/Separator Box: Designed for easy
installation, the grease is routed from a single swiveling
collection spout to an amply sized durable galvanized steel
box, trapping grease and residue, and avoiding discharge onto
the roof surface. Additionally, these boxes separate the water
from the grease, prolonging the time required between periodic
maintenance.
Additional Fatrap Accessories
Ventilated Curbs and Pedestals: For buildings two stories or
higher NFPA 96 requires the use of ventilated mounting curbs or
pedestals to provide an approved arrangement for connecting a
range hood and duct work to the roof fan. PennBarry’s ventilated
mounting curbs and pedestals, 18” high, comply with that standard
when properly installed. Ventilated curbs have a flat mounting
flange for fastening directly to the roof deck. This flange should
be securely fastened and flashed to ensure weather tightness.
Ventilated pedestals are designed to fit on an existing curb. They
provide cap flashing when so installed.
BACKDRAFT
DAMPER
6
www.PennBarry.com | Moving Your Way
©PENNBARRY 2014
Make-Up Air Units (Suplex): Fumex fans with the Fatrap
configuration can be combined with a PennBarry FS Muffan
fan to create an integrated unit called the Suplex. The Fumex
handles the required air flow to be exhausted while the Muffan
provides an appropriate amount of supply make-up air. The
modular design of the Suplex means that just one roof opening
is needed for both the exhaust and supply ducts. An insulated
shield divides the base to separate the exhaust and make-up air
compartments, and prevents heat transfer between hot exhaust
air and fresh filtered air. This results in a complete air-tight seal
between the hood and exhaust fan.
Fumex | FX
OPTIONS & ACCESSORIES
Heat & Smoke Removal Configuration
While Fumex fans are commonly used for general ventilation, they
are also designed to discharge contaminated or grease-laden air
or fumes up and away from building surfaces with the Fatrap
option and when equipped with the Heat and Smoke Removal
option, this series of fans incorporates features exclusively
designed to exhaust heat and smoke in the event of fire. During
these emergencies, the fans are designed to operate at the
temperature and time limits stated below. To maintain power
to these fans during emergencies, special consideration must
be made for field power supply. In the event of an emergency,
if power is maintained, the units will operate for the times and
temperatures indicated, after which they will continue to operate
until they are destroyed by the extreme temperature generated
during an actual fire, or their roof structure collapses.
ADDITIONAL
COOLING TUBE
STEEL WHEEL
PREFABRICATED
CURB
For smoke control systems, Heat and Smoke Removal configured
fans are listed per UL for emergency smoke removal, referencing
UL705, UL793, Industrial Risk Insurers (IRI), and Southern
Building Code Congress International (SBCCI).
The UL standard requires the fan to run at 500°F for 4 hours (IRI) and 1000°F for 15 minutes (SBCCI). PennBarry Heat and Smoke
Removal configured Fumex units are listed at 500°F for 4 hours and 1000°F for 1 hour. The additional 45 minutes at 1000°F will buy
precious time in the event of a fire.
Steel Wheel: The wheel is a standard duty, all welded wheel (standard duty and high pressure belt drive). The blades are curved
for improved air performance while increasing their strength and rigidity. The wheel assembly is fully welded to provide extremely
durable and consistent performance. The wheel is dynamically balanced. Balancing weights are mechanically attached to the inside
of the rims of both the back plate and wheel inlet. This allows a precise placement of the weights anywhere within a full 360° range
on two separate planes, without the possibility of detachment.
Forced Motor Cooling: Motors and drive components are located out of the airstream in a separate compartment. Two cooling
tubes are located between the motor dome and discharge apron which enables fresh air to be drawn into the motor compartment
during fan operation. This allows the cooler outside air to wash over the motor and bearings. This positive cooling promotes longer
life for the motor and drive components.
High Wind Construction
High wind construction Fumex fans are specifically designed
for high wind hurricane zones (HWHZ). The Fumex models
are designed to withstand 150 MPH winds in accordance with
Miami-Dade and Florida Building Code standards. The units are
3rd party tested and certified through a 3rd party Professional
Engineer (P.E.) to meet these strict standards. Installation details
are provided and since there are no tie downs or external braces
required for attaching the unit to the roof or curb this makes
installation simple and easy. A wide range is offered to meet all
of your ventilation needs which includes all belt and direct drive
sizes 36 and under.
©PENNBARRY 2014
Product Certifications:
•Miami-Dade NOA # 14-0311.03
•Florida Product Approval #12339
•Texas Department of Insurance # RV-48
www.PennBarry.com | Moving Your Way
Belt Drive
Fumex Cutaway
Direct Drive
Fumex Cutaway
7
Fumex | FX
MOTOR AVAILABILITY
Model
Green Plus Electronically Commutated Motor
The Green Plus (GP) option utilizes EC motors to provide
significantly greater efficiency, flexibility, and controllability over
standard direct drive permanent split capacitor (PSC) motors.
Using the included potentiometer, the Green Plus motors can
be turned down to as low as 80% the max operating speed
while maintaining 90% efficiency through the operating range.
Additionally, the Green Plus can accept 0-10V input to tie to
building management systems, allowing for savings in not only
direct fan energy consumption but reducing the exhaust of
conditioned air during off peak hours as well. All Green Plus
motors come in open enclosure for usage with 115-208/230V,
single phase, 60 Hz applications.
NEMA Motor
This chart summarizes the largest allowable NEMA frame sizes
for motors used on belt drive models.
Largest Available NEMA Frame Size per Model
Model
Max. Frame Size
Model
Max. Frame Size
FX08B
56
FX18B
145T
FX10B
56
FX18BH
145T
FX12BH
56
FX24B
184T
FX13B
56
FX24BH
184T
FX13BHFT
56
FX27B/FX30B
184T
FX14B
56
FX36B
213T
FX16B
145T
FMX50B
215T
At PennBarry’s option, large frame motors may be removed after testing and
shipped separately. Contact the factory for special application motor availability.
WFX/FX
Size
Tap
ECM HP
08
S
0.33
08
R
0.33
10
S
0.33
10
R
0.33
11
V
0.33
11
S
0.33
11
R
0.33
11
Q
0.33
13
V
0.33
13
S
0.33
13
R
0.33
13
Q
0.33
16
V
0.33
16
S
0.50
16
R
0.50
16
Q1
0.50
16
Q2
0.75
18
V
0.75
Available Lek-Trol™ Speed Controls
60 Hz
Model
ODP
50 Hz
Totally Enclosed
Totally Enclosed
115V
115V
200V
208V
230V
110V
220V
240V
FX08S
-
-
-
-
-
-
-
-
FX08R
LT25
-
-
-
-
-
-
-
FX10S
-
-
-
-
-
-
-
-
FX10R
LT30
LT30
LT35
LT35
LT35
LT30
LT35
LT35
FX11V
-
-
-
-
-
-
-
-
FX11S
-
-
-
-
-
-
-
-
FX11R
LT30
-
-
-
-
-
-
-
FX11Q
LT50
-
-
-
-
-
-
-
FX13V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
LT30
LT30
LT35
LT35
LT35
LT50
LT35
LT35
Variable Speed Motor Control
FX13Q
LT45
LT50
LT35
LT35
LT35
LT50
LT35
LT35
PennBarry offers Lek-Trol™ solid state controllers to alter the
high speed of most direct drive motors by as much as 50%. If
variable speed is required, check the Lek-Trol™ availability table
below to verify that controllers exist for the fan model selected.
Remember, Lek-Trol™ controllers are currently only available
for direct drive motors including all standard Open Drip Proof
(ODP) 60 Hz motors. Not all totally enclosed motors are currently
available with variable speed control. Inverter rated motors
suitable for use with variable frequency drives can be supplied for
belt drive models. Contact your local PennBarry representative
for availability.
FX16V
-
-
-
-
-
-
-
-
FX16S
-
-
-
-
-
-
-
-
FX16R
LT50
-
-
-
-
-
-
-
FX16Q1
LT40
-
-
-
-
-
-
-
FX16Q2
LT75
-
-
-
-
-
-
-
FX18V
LT60
-
-
-
-
-
-
-
8
Lek-Trols™ indicated for multi-speed models (eg., FX16V/S/R) are applicable only
for the high speed. Do not use on low or medium speed for multi-speed models.
Items noted with ( - ) are not applicable.
www.PennBarry.com | Moving Your Way
©PENNBARRY 2014
FX13S
FX13R
Fumex | FX
MOTOR AVAILABILITY
Direct Drive Motor Availability
The following chart lists the various motor options available for each of the direct drive fan models. Once a fan model is selected,
this chart can be used to determine if a suitable motor is available. (If not, another selection may have to be made from the fan
performance charts). Look under the nominal RPM heading to determine which fans have 2-speed and 3-speed motors.
Nominal RPM
Model
1 Phase
1050
V
1300
S
1550
R
1725
Q
FX08S/R
-
x
x
FX10S/R
-
x
x
FX11V/S/R
x
x
FX11Q
-
FX13V/S/R
115 Volts
200 - 240 Volts
Open Drip
Proof
Totally
Enclosed
Explosion
Proof
-
yes
yes (1)
-
yes
yes (1)
x
-
yes
-
-
x
x
x
x
FX13Q
-
-
-
FX16V/S/R
x
x
FX16Q1
-
-
FX16Q2
-
FX18V
x
Totally
Enclosed
50 hz
50 C
Ambient
Explosion
Proof (4)
-
yes (1)
yes (1)
yes (1)
-
-
yes (1)
yes (1)
yes (1)
-
yes (1)
-
yes (1)
yes (1)
yes (1)
-
yes
yes
yes
yes
yes
yes
yes (5)
-
yes
yes (1)
-
yes (1)
yes (1)
yes (1)
-
x
yes
yes
yes
yes
yes
yes
yes (5)
x
-
yes
yes (1)
-
yes (1)
yes (1)
yes (1)
-
-
x (3)
yes
-
-
-
-
-
-
-
-
x
yes
yes
yes
yes
yes
yes
yes (5)
-
-
-
yes
-
-
-
-
-
-
Nominal RPM
Open Drip
Proof
Use
TE
Motors
3 Phase
Model
200 - 460 Volts (2)
1050
V
1300
S
1550
R
1725
Q
Totally Enclosed
50 hz
50 C Ambient
Explosion Proof (4)
FX08S/R
-
x
x
-
-
-
-
-
FX10S/R
-
x
x
-
-
-
-
-
FX11V/S/R
x
x
x
-
-
-
-
-
FX11Q
-
-
-
x
-
-
-
yes (6)
FX13V/S/R
x
x
x
-
FX13Q
-
-
-
x
FX16V/S/R
x
x
x
FX16Q1
-
-
-
FX16Q2
-
-
-
FX18V
x
-
-
Open Drip Proof
Use
TE
Motors
-
-
-
-
yes
yes
yes
yes (6)
-
-
-
-
-
x (3)
-
-
-
-
x
-
-
-
yes (6)
-
-
-
-
-
©PENNBARRY 2014
(1) High speed only.; (2) 200 - 240, 380, 415, 460 V; (3) Nominal 1650 RPM; (4) Cls.I, Grp.D, Div. I / Cls. II, Grp.F & G, Div.I., Not available with 50 Hz.;
(5) 230 V only. Not available in 200 or 208 V; (6) 230 V and 460 V only.
www.PennBarry.com | Moving Your Way
9
Fumex | FX
FX08 - FX13 | DIRECT DRIVE
Performance Data Overview
reasons, including energy savings, off
hours requirements, future expansion, or
unexpected field variations.
Fumex direct drive models are available
with single and multi-speed motors.
Multi-speed motors (eg., FX16V/S/R)
are designated: V (1050 RPM), S (1300
RPM), and R (1550 RPM). FX18V is an
exception, being a single speed motor. Q,
Q2 (1725 RPM) and Q1 (1650 RPM) are
single speed motors. A single Fumex fan
may be suitable for several requirements
by a simple wiring change. This feature
provides flexibility for a variety of
Fumex direct drive models are available
in six sizes (8, 10, 11, 13, 16, and 18).
Capacities up to 4500 CFM, with static
pressures to 1 1/2”.
By using Lek-Trol™ variable speed
controllers, the high speed flow rate of
most models can be reduced by as much
as 50%. Do not use Lek-Trol™ on medium
or low speed for multi-speed models.
When compared to belt drive models,
direct drive fans require less maintenance,
have a simpler construction, cost less,
and are lighter in weight.
Performances in 50 Hz applications will
be less than shown below; consult your
local PennBarry representative.
FX08 - FX11
16 ⅞"
25"
16 ⅞"
1 ¼"
1 ¼"
(FX Units Only) Galv. Steel Base = 16 Gage
24"
24"
9" x 9"
WFX08
Only
14 ⅛" 25"
11 ½" x 11 ½"
WFX10
WFX11
Only
25"
(WFX Units Only) Aluminum Base = 0.064
(FX Units Only) Aluminum Base = 0.050
Discharge Apron = 0.050
FX08 Estimated Ship Weight = 29 lbs.
FX10 Estimated Ship Weight = 32 lbs.
FX11V/S/R Estimated Ship Weight = 42 lbs.
FX11Q Estimated Ship Weight = 44 lbs.
18 ½" x 18 ½"
Nominal
HP
Max
Watts
RPM
Tip
Speed
FPM
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
FX08S
1/50
44
1300
3361
247
1.3
150
2.0
94
3.2
54
4.3
-
-
-
-
-
-
-
-
FX08R
1/30
55
1550
4007
288
2.4
205
2.9
154
3.5
112
4.4
72
5.2
-
-
-
-
-
-
FX10S
1/25
85
1300
3361
400
3.5
309
3.8
246
4.1
194
4.6
152
5.0
109
5.5
57
6.1
-
-
FX10R 1/12(1)
122
1550
4007
570
6.2
500
6.6
440
6.8
385
6.8
325
6.8
251
6.9
170
7.1
-
-
FX11V
1/25
103
1050
3058
406
1.9
225
2.2
151
3.6
119
4.2
87
4.8
57
5.5
-
-
-
-
FX11S
1/11
142
1300
3786
534
3.9
414
4.2
337
5.1
273
5.9
223
6.2
177
6.5
129
6.9
-
-
FX11R
1/6(2)
199
1550
4514
760
7.6
667
7.4
586
7.6
512
7.9
434
8.9
359
9.6
283
9.6
118
9.7
FX11Q
1/5
255
1725
5024
1034
10.7
959
10.5
883
10.5
804
10.5
722
10.6
631
10.9
538
10.7
313
9.7
Model
0.000” SP
0.125” SP
0.250” SP
0.375” SP
0.500” SP
0.625” SP
0.750” SP
1.000” SP
(1) TE motor is 1/6 Hp. (2) TE motor is 1/7 Hp. See additional notes on page 11.
FX13
17 ⅞"
25 ½"
1 ¼"
(FX Units Only) Galv. Steel Base = 16 Gage
24"
16 ½"
25 ½"
(WFX Units Only) Aluminum Base = 0.064
(FX Units Only) Aluminum Base = 0.050
Discharge Apron = 0.050
11 ½" x 11 ½"
FX13S/R Estimated Ship Weight = 45 lbs.
FX13Q Estimated Ship Weight = 52 lbs.
18 ½" x 18 ½"
Nominal
Model
FX13V
1/20
113
1050
3221
640
4.2
469
2.8
317
2.4
250
3.1
197
3.8
149
4.5
106
5.2
-
-
-
FX13S
1/12
148
1300
3988
845
7.4
735
6.4
612
5.2
492
5.0
404
5.3
334
5.7
270
6.1
136
7.0
-
-
FX13R
1/6
188
1550
4755
1057
10.5
980
10.1
908
9.6
825
8.6
733
8.1
646
8.1
561
8.2
376
8.2
144
8.5
FX13Q
1/4
343
1725
5292
1261
13.6
1198
13.0
1143
12.6
1093
12.1
1033
11.7
973
11.2
909
10.8
757
10.1
515
9.6
See notes on page 11.
10
www.PennBarry.com | Moving Your Way
©PENNBARRY 2014
HP
Tip
0.000” SP
0.125” SP
0.250” SP
0.375” SP
0.500” SP
0.625” SP
0.750” SP
1.000” SP
1.250” SP
Speed
Max
RPM FPM
Watts
CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones
Fumex | FX
FX16 - FX18 | DIRECT DRIVE
FX16
30 ¾"
24 ¼"
1 ¼"
(FX Units Only) Galv. Steel Base = 16 Gage
Aluminum Base = 0.064
24"
22 ⅜"
Discharge Apron = 0.064
30 ¾"
16" x 16"
FX16Q Estimated Ship Weight = 71 lbs.
20 ½" x 20 ½"
Nominal
Model
Tip
0.000” SP
0.125” SP
0.250” SP
0.375” SP
0.500” SP
0.625” SP
0.750” SP
1.000” SP
1.250” SP
1.500” SP
Speed
RPM FPM CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones
HP
Max
Watts
FX16V
1/6
485
1050
3788 1604
7.9
1358
6.5
1128
5.5
951
5.8
801
6.3
705
6.9
644
7.7
522
9.2
384
9.3
230
FX16S
1/3
527
1300
4690 1874
10.7
1693
9.5
1514
8.6
1326
8.0
1158
7.6
1023
7.7
913
8.2
735
9.6
572
9.7
379
9.9
FX16R
1/3(1)
590
1550
5592 2140
12.8
1994
11.9
1849
11.0
1709
10.2
1561
9.9
1410
9.6
1269
9.4
1033
9.7
812
11.1
583
10.8
FX16Q1
1/2
715
1650
5953 2531
15.2
2432
14.7
2332
14.2
2232
13.7
2114
13.1
1992
12.5
1868
11.9
1582
11.0
1320
11.5
1001
12.1
FX16Q2
3/4
890
1725
6223 2822
17.1
2753
16.8
2684
16.5
2594
16.1
2501
15.7
2418
15.4
2331
15.1
2119
14.2
1872
14.1
1566
14.2
9.7
(1) TE motor is 1/2 Hp. See additional notes at bottom of page.
FX18
32 ½"
39"
1 ¼"
(FX Units Only) Galv. Steel Base = 16 Gage
Aluminum Base = 0.064
29 ½"
31"
Discharge Apron = 0.080
20" x 20"
39"
FX18V Estimated Ship Weight = 87 lbs.
28 ½" x 28 ½"
Nominal
Model
FX18V
HP
Max
Watts
3/4
969
Tip
0.000” SP
0.125” SP
0.250” SP
0.375” SP
0.500” SP
0.625” SP
0.750” SP
1.000” SP
1.250” SP
1.500” SP
Speed
RPM FPM CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones
1075
6029 4489
21.0
4333
21.0
4177
20.0
4011
19.1
3831
18.1
3652
17.6
3455
17.2
3023
16.5
2431
17.5
1447
20.0
Performance shown is for installation Type A: Free Inlet, Free Outlet. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings
shown are for loudness values in fan sones at 5’0” (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for Installation Type A: free inlet
hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the air stream.
©PENNBARRY 2014
Fumex fans are only one component of a total system. As such, fan performance is directly affected by the system. It is critical that system designers determine the actual
system loss to ensure that the actual flow is specified in the system design.
www.PennBarry.com | Moving Your Way
11
Fumex | FX
DIRECT DRIVE PERFORMANCE DATA
The fan curves illustrated here show the range of capacities
available for direct drive units. Each graph shows the performance
of several models at one particular nominal speed. Fan curves
provide a quick method for selecting a fan unit based on design
point requirements.
The direct drive performance charts on the previous pages
provides the tabular data (CFM and static pressure) used to plot
the fan curves. In addition, the horsepower tip speed and sones
are tabulated. Since sound is normally an important factor in the
selection of a fan, an engineer will usually want to select the
“slowest” unit which meets CFM and SP requirements.
Please refer to the Motor Availability section to make sure the
motor you select meets your electrical requirements.
Nominal 1075 RPM
1.800
STATIC PRESSURE - Inches W.G.
Fan Curves
1.600
1.400
FX
18
1.200
R
1.000
0.800
0.600
0.400
0.200
0.000
0
500 1000 1500 2000 2500 3000 3500 4000 4500 5000
AIRFLOW - CFM
Nominal 1550 RPM
2.250
1.750
2.000
1.500
1.250
1.000
0.750
R
11
R
250
13V
250
500
R
0
0.500
0.250
FX
500
750
1000
1250
1500
1750
0.000
2000
0
750
AIRFLOW - CFM
2.000
1.500
1.250
FX
Q
16
2
(N
al
in
om
50
M
RP
0.500
16
S
Q
11
13
0.750
13Q
0.500
1
S
1.000
Q
16
1.250
16
FX
0.750
0.250
S
S
500
750
1000
1250
AIRFLOW - CFM
1500
1750
2000
0.000
0
400
800
1200
1600
2000
2400
2800
3200
AIRFLOW - CFM
Fumex fans are only one component of a total system. As such, fan performance is directly affected by the system. It is critical that system designers determine the actual
system loss to ensure that the actual flow is specified in the system design. Performance shown is for installation Type A: Free Inlet, Free Outlet. Speed (RPM) shown is
nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances in the air stream.
12
www.PennBarry.com | Moving Your Way
©PENNBARRY 2014
S
11
FX
10
08
FX
FX
250
2000 2250
1.500
FX
1.000
0
1750
1.750
FX
STATIC PRESSURE - Inches W.G.
1.750
FX
STATIC PRESSURE - Inches W.G.
2.250
0.000
1500
Nominal 1725 RPM
2.000
0.250
1000 1250
AIRFLOW - CFM
Nominal 1300 RPM
FX
R
0.750
10
11
V
16
08
0.000
FX
FX
FX
0.250
V
1.000
R
16
1.250
13
FX
1.500
FX
0.500
1.750
FX
STATIC PRESSURE - Inches W.G.
2.000
FX
STATIC PRESSURE - Inches W.G.
Nominal 1050 RPM
Fumex | FX
BELT DRIVE PERFORMANCE DATA
Performance Data
Belt Drive Losses
The belt drive models shown on the following pages have sizes
and capacities ranging from below 250 CFM to above 30,000
CFM, with static pressures from 0” to 4”. All models are available
with a wide range of horsepower sizes and RPM’s. Two-speed
motors are commonly used to enhance this flexibility.
The AMCA Review Committee has developed the chart shown
below for the purpose of estimating belt drive losses. To calculate
total BHP (including drive losses): Find the BHP of your operating
point on the x-axis on the graph below. Follow the vertical line to
the curves indicating the range of drive losses. Look at the y-axis
on the left and find the drive loss percentage. Calculate the total
BHP by adding the drive loss to the operating point BHP. For
BHP’s below 0.3, use 30%.
• Elevation Drawing Showing Overall Dimensions
• Fan Curve Graph
• Performance Chart
Each curve graphically displays the range of capacities available
for each model, in most cases beyond the specifics shown in
the tabular data. The maximum performance afforded by each
horsepower is indicated by dashed lines and the RPM is indicated
by solid lines.
Some models have graphs that show both shaded and unshaded
areas. Selection should be made from the unshaded area
only. Shaded areas reflect unstable performance (“surge”), a
characteristic typical of backward inclined wheels, and should
be avoided. These unstable regions are not shown in the tabular
data.
The highest RPM shown for a specific horsepower in the
tabular data is the maximum speed that for any point along
the performance curve, the BHP will not exceed the available
horsepower.
It is important to note that while it is common industry-wide
practice to exceed a “nominal” horsepower by using a motor’s
service factor, PennBarry uses a conservative portion of the
service factor, allowing half to remain a true “safety” factor.
Drive Loss Reference Chart
30
DRIVE LOSS
(% MOTOR POWER OUTPUT)
The data provided for each belt drive model includes:
20
15
10
8
6
4
3
2
1.5
1
0.3 0.4
0.6 0.8 1
2
3
4
6
8 10
MOTOR POWER OUTPUT (BHP)
20
Range drive loss for standard belts. Higher fan speeds
tend to have higher drive losses than lower fan speeds
at the same horsepower.
For totally enclosed, explosion proof, multi-speed and all 1.0 Service Factor
motors, fan BHP plus drive losses should not exceed motor rated HP.
Graph reprinted from AMCA publication 203, with the express written permission
from the Air Movement and Control Association, Inc., 30 West University Drive,
Arlington Heights, IL 60004-1983.
Use the Motor Availability chart (see Motor Selection) to select
motor enclosures and voltages which can be installed in the fans.
©PENNBARRY 2014
Note: Fumex fans are only one component of a total system. As such, performance
is directly affected by the system. It is critical that system designers determine
actual system losses to ensure that the actual flow is specified in the system range.
www.PennBarry.com | Moving Your Way
13
Fumex | FX
STATIC PRESSURE - Inches W.G.
FX08B | BELT DRIVE
30"
35"
2.400
1975 RPM
5 ¾"
5 ¾"
2.000
27 ¼"
1719 RPM
1.600
28 ¾"
495 RPM
1.200
1374 RPM
0.800
3/
4
0.400
0.000
16" x 16"
35"
1/4
0
200
400
600
1/3
HP
1/
HP
800
AIRFLOW - CFM
2
H
P
24 ¾" x 24 ¾"
HP
1000
1200
Galv. Steel Base = 16 Gage
Aluminum Base = 0.064
Discharge Apron = 0.064
Roof/Wall Opening = 16” SQ.
Damper Size = 15 ¾” SQ.
Max. Motor Frame Size = 55
Peak BHP = (RPM/2126)3
Max. RPM = 2085 (1 HP)
Est. Ship Weight = 96 lbs.*
* Add 8 lbs. for Heat & Smoke option.
Tip
0.000” SP
0.125” SP
0.250” SP
0.375” SP
0.500” SP
0.625” SP
0.750” SP
0.875” SP
1.000” SP
1.125” SP
HP RPM Speed
FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
1191
525
1787
700
2382
875
2978
1050
3574
1225
4169
1374
4676
1410
4799
1440
4901
1470
5003
1495
5088
1535
5224
1565
5326
1595
5428
1/2 1630
5548
1665
5667
1695
5769
1719
5850
1755
5973
1795
6109
1830
6228
1860
6330
1890
6432
1920
6535
1950
6637
1975
6722
1/4
1/3
3/4
208
1.7 0.01
312
4.2 0.01
416
4.5 0.03
520
5.9 0.06
624
8.0 0.11
728
10.6 0.17
817
12.1 0.25
838
12.6 0.27
856
13.0 0.28
874
13.4 0.30
889
13.8 0.32
912
14.3 0.34
930
14.6 0.36
948
14.9 0.39
969
15.4 0.41
990
15.8 0.44
1008
16.2 0.46
1022
16.6 0.48
1043
17.1 0.51
1067
17.7 0.55
1088
18.3 0.58
1106
18.8 0.61
1124
19.4 0.64
1141
19.8 0.67
1159
20.0 0.70
1174
21.0 0.73
162
4.2 0.01
320
4.4 0.03
447
5.8 0.07
563
7.9 0.11
677
10.4 0.18
771
11.9 0.25
793
12.3 0.27
812
12.7 0.29
831
13.2 0.31
846
13.5 0.32
871
14.0 0.35
890
14.4 0.37
909
14.0 0.39
930
15.1 0.42
952
16.7 0.44
970
17.1 0.47
985
16.4 0.49
1007
16.9 0.52
1032
17.5 0.56
1053
18.1 0.59
1072
18.6 0.62
1090
19.1 0.65
1109
19.6 0.68
1127
20.0 0.71
1142
20.0 0.74
163
4.2 0.03
359
5.6 0.07
497
7.6 0.12
623
10.2 0.18
724
11.6 0.25
748
12.1 0.27
767
12.5 0.29
787
12.9 0.21
804
13.3 0.33
830
13.8 0.35
849
14.1 0.37
869
14.5 0.40
891
14.9 0.42
914
15.3 0.45
933
15.7 0.47
948
16.1 0.49
971
16.7 0.52
997
17.3 0.56
1019
17.8 0.59
1038
18.4 0.62
1057
18.9 0.65
1076
19.4 0.68
1095
19.8 0.72
1110
20.0 0.74
231
5.3 0.07
422
7.3 0.12
564
9.8 0.18
674
11.3 0.26
700
11.8 0.27
722
12.2 0.29
743
12.6 0.31
760
13.0 0.33
787
13.5 0.35
807
13.8 0.37
828
14.2 0.40
851
14.6 0.42
875
15.1 0.45
895
15.5 0.48
911
15.9 0.50
934
16.4 0.53
961
17.0 0.56
984
17.6 0.60
1003
18.1 0.63
1023
18.6 0.66
1042
19.1 0.69
1062
19.6 0.72
1078
20.0 0.75
324
6.9 0.12
498
9.4 0.19
619
11.0 0.26
647
11.4 0.28
670
11.8 0.30
693
12.3 0.32
711
12.7 0.33
741
13.2 0.36
763
13.5 0.38
785
13.9 0.40
810
14.3 0.42
835
14.8 0.45
856
15.2 0.48
872
15.6 0.50
897
16.2 0.53
924
16.8 0.56
948
17.4 0.60
968
17.9 0.63
988
18.4 0.66
1008
18.9 0.69
1028
19.3 0.72
1045
19.7 0.75
108
6.0 0.10
421
9.0 0.19
560
10.7 0.27
591
11.1 0.29
616
11.5 0.30
640
11.9 0.32
660
12.3 0.34
692
12.9 0.37
715
13.2 0.39
738
13.5 0.41
764
14.0 0.43
790
14.5 0.46
813
14.9 0.48
830
15.2 0.50
857
15.8 0.53
886
16.5 0.57
911
17.1 0.60
933
17.6 0.63
953
18.1 0.66
974
18.6 0.69
995
19.1 0.72
1012
19.5 0.75
306
8.3 0.18
493
10.3 0.26
528
10.8 0.29
557
11.2 0.31
584
11.6 0.33
605
11.9 0.34
639
12.5 0.37
664
12.8 0.39
689
13.2 0.41
717
13.6 0.44
745
14.1 0.47
768
14.6 0.49
787
14.9 0.51
814
15.5 0.54
844
16.2 0.58
870
16.8 0.61
893
17.3 0.64
915
17.8 0.67
937
18.3 0.70
959
18.8 0.73
977
19.1 0.76
407
9.9 0.26
455
10.4 0.28
489
10.9 0.30
519
11.3 0.32
543
11.6 0.34
582
12.1 0.37
611
12.5 0.39
637
12.9 0.42
667
13.3 0.44
696
13.8 0.47
721
14.2 0.50
741
14.6 0.52
770
15.2 0.55
802
15.8 0.58
829
16.5 0.62
853
17.0 0.65
875
17.5 0.68
898
18.0 0.71
920
18.5 0.74
939
18.8 0.77
275
9.2 0.24
346
9.9 0.27
394
10.4 0.29
437
11.0 0.31
472
11.4 0.33
518
11.8 0.37
548
12.1 0.39
578
12.5 0.41
612
13.0 0.44
646
13.5 0.48
672
13.9 0.50
693
14.3 0.52
723
14.8 0.55
757
15.5 0.59
786
16.2 0.62
810
16.7 0.66
834
17.2 0.68
858
17.7 0.72
882
18.2 0.75
901
18.6 0.78
152
9.0 0.23
252
9.7 0.27
318
10.3 0.30
366
10.9 0.32
429
11.5 0.35
472
11.9 0.38
511
12.3 0.41
551
12.7 0.44
587
13.1 0.47
616
13.6 0.50
640
13.9 0.52
674
14.5 0.56
711
15.2 0.59
741
15.9 0.63
766
16.4 0.66
791
17.0 0.69
816
17.4 0.72
841
17.9 0.75
861
18.3 0.78
Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive
losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard
301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream.
14
www.PennBarry.com | Moving Your Way
©PENNBARRY 2014
350
Fumex | FX
30"
35"
5 ¾"
RPM
BHP
1815 RPM
5 ¾"
Do not select in shaded area.
27 ¼"
1578 RPM
28 ¾"
1372 RPM
16" x 16"
35"
1260 RPM
1600
AIRFLOW - CFM
2000
HP
1200
4
800
24 ¾" x 24 ¾"
3/
400
HP
0
HP
2
1/
4
HP
1/
3
2.200
2.000
1.800
1.600
1.400
1.200
1.000
0.800
0.600
0.400
0.200
0.000
1/
STATIC PRESSURE - Inches W.G.
FX10B | BELT DRIVE
2400
Galv. Steel Base = 16 Gage
Aluminum Base = 0.064
Discharge Apron = 0.064
Roof/Wall Opening = 16” SQ.
Damper Size = 15 ¾” SQ.
Max. Motor Frame Size = 56
Peak BHP = (RPM/1869)3
Max. RPM = 2085 (1 ½ HP)
Est. Ship Weight = 96 lbs.*
* Add 8 lbs. for Heat & Smoke option.
Tip
0.000” SP
0.125” SP
0.250” SP
0.375” SP
0.500” SP
0.625” SP
0.750” SP
1.000” SP
1.125” SP
1.250” SP
HP RPM Speed
FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
1/4
1/3
1/2
©PENNBARRY 2014
3/4
600
2042
750
2553
900
3063
1000
3403
1100
3744
1260
4288
1300
4424
1325
4509
1350
4595
1372
4669
1390
4731
1420
4833
1450
4935
1475
5020
1500
5105
1525
5190
1550
5275
1578
5371
1600
5445
1630
5548
1660
5650
1695
5769
1730
5888
1765
6007
1790
6092
1815
6177
714
5.9 0.02
892
6.7 0.05
1071
7.3 0.08
1190
8.6 0.11
1309
10.4 0.14
1499
13.5 0.22
1547
13.9 0.24
1577
14.2 0.25
1607
14.4 0.27
1633
14.7 0.28
1654
15.0 0.29
1690
15.4 0.31
1726
15.9 0.33
1755
16.3 0.35
1785
16.7 0.36
1815
17.0 0.38
1845
17.2 0.40
1878
17.4 0.42
1904
17.6 0.44
1940
17.8 0.47
1976
18.0 0.49
2017
18.4 0.53
2059
18.8 0.56
2101
19.3 0.59
2130
19.8 0.62
2160
20.0 0.65
543
5.7 0.03
765
6.6 0.05
968
7.1 0.09
1097
8.4 0.12
1225
10.2 0.15
1426
13.2 0.23
1476
13.6 0.25
1507
13.9 0.26
1538
14.2 0.28
1565
14.5 0.29
1587
14.7 0.30
1624
15.2 0.32
1662
15.7 0.34
1692
16.1 0.36
1723
16.5 0.38
1754
16.8 0.40
1785
17.0 0.42
1819
17.2 0.44
1846
17.4 0.46
1883
17.6 0.48
1920
17.9 0.51
1962
18.2 0.54
2005
18.6 0.58
2048
19.2 0.61
2078
19.6 0.64
2109
20.0 0.66
596
6.5 0.06
854
7.1 0.09
998
8.3 0.13
1136
10.0 0.16
1352
13.0 0.24
1404
13.4 0.26
1437
13.7 0.28
1469
13.9 0.29
1497
14.2 0.31
1521
14.5 0.32
1559
14.9 0.34
1597
15.4 0.36
1629
15.9 0.38
1661
16.3 0.39
1693
16.6 0.41
1725
16.8 0.43
1760
17.0 0.46
1788
17.2 0.47
1826
17.4 0.50
1864
17.7 0.53
1908
18.1 0.56
1952
18.5 0.59
1995
19.0 0.63
2027
19.5 0.66
2058
20.0 0.68
696
7.1 0.10
874
8.3 0.13
1042
9.9 0.17
1271
12.7 0.25
1327
13.1 0.27
1361
13.4 0.29
1396
13.7 0.30
1426
13.9 0.32
1450
14.2 0.33
1491
14.6 0.35
1531
15.1 0.37
1565
15.6 0.39
1599
16.0 0.41
1632
16.3 0.43
1665
16.5 0.45
1701
16.8 0.47
1730
16.9 0.49
1769
17.2 0.52
1808
17.5 0.54
1853
17.9 0.58
1898
18.3 0.61
1943
18.9 0.65
1975
19.4 0.67
2007
19.9 0.70
730
8.4 0.13
915
9.9 0.18
1187
12.6 0.26
1249
13.0 0.28
1285
13.2 0.30
1320
13.4 0.31
1352
13.7 0.33
1377
13.9 0.34
1419
14.3 0.36
1461
14.8 0.38
1496
15.3 0.40
1531
15.7 0.42
1565
15.9 0.44
1600
16.2 0.46
1638
16.4 0.48
1668
16.6 0.50
1709
16.9 0.53
1749
17.2 0.56
1796
17.6 0.59
1843
18.0 0.63
1890
18.6 0.66
1923
19.0 0.69
1955
19.6 0.72
780
9.9 0.18
1076
12.6 0.26
1144
12.9 0.29
1187
13.1 0.30
1229
13.4 0.32
1266
13.6 0.33
1296
13.8 0.35
1345
14.1 0.37
1391
14.6 0.39
1427
15.0 0.41
1463
15.4 0.43
1498
15.6 0.45
1534
15.8 0.47
1573
16.1 0.49
1604
16.3 0.51
1646
16.6 0.54
1688
16.9 0.57
1736
17.3 0.60
1784
17.7 0.64
1832
18.3 0.68
1866
18.7 0.70
1900
19.2 0.73
961
12.6 0.26
1035
12.9 0.29
1080
13.1 0.31
1125
13.3 0.32
1164
13.5 0.34
1195
13.6 0.35
1247
13.9 0.37
1298
14.4 0.40
1340
14.8 0.42
1382
15.1 0.44
1423
15.3 0.46
1465
15.6 0.48
1509
15.8 0.51
1541
16.0 0.53
1584
16.2 0.55
1627
16.5 0.58
1676
16.9 0.62
1726
17.4 0.65
1775
18.0 0.69
1810
18.4 0.72
1844
18.9 0.75
892
13.3 0.32
943
13.5 0.34
984
13.6 0.35
1044
13.9 0.38
1100
14.3 0.40
1147
14.6 0.42
1193
14.9 0.44
1239
15.0 0.47
1284
15.1 0.49
1333
15.3 0.52
1371
15.4 0.54
1423
15.5 0.57
1474
15.8 0.60
1534
16.2 0.63
1592
16.7 0.67
1650
17.3 0.71
1692
17.7 0.74
1732
18.2 0.77
909
13.9 0.38
988
14.3 0.40
1045
14.6 0.42
1096
14.9 0.44
1143
15.0 0.47
1190
15.1 0.49
1241
15.3 0.52
1282
15.4 0.54
1336
15.5 0.57
1390
15.7 0.60
1451
16.0 0.64
1511
16.3 0.68
1571
16.8 0.72
1613
17.3 0.75
1655
17.8 0.78
968
14.9 0.44
1034
15.0 0.47
1091
15.1 0.49
1149
15.3 0.52
1191
15.4 0.54
1247
15.5 0.57
1302
15.7 0.60
1367
16.0 0.64
1430
16.3 0.68
1492
16.7 0.72
1535
17.0 0.75
1578
17.3 0.78
Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive
losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard
301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream.
www.PennBarry.com | Moving Your Way
15
Fumex | FX
STATIC PRESSURE - Inches W.G.
FX12BH | BELT DRIVE
3.250
3.000
2.750
2.500
2.250
2.000
1.750
1.500
1.000
0.750
0.500
0.250
0.000
30"
35"
5 ¾"
RPM
BHP
1883 R
PM
5 ¾"
Do not select in shaded area.
27 ¼"
1639 R
28 ¾"
PM
1511 R
PM
16" x 16"
35"
1314 RPM
1142 RP
M
1049 RPM
1
1/2
1/4 1/3
HP HP
0
400
HP
3/
4
HP
1
HP
1/
2
HP
24 ¾" x 24 ¾"
800 1200 1600 2000 2400 2800 3200 3600 4000
AIRFLOW - CFM
Galv. Steel Base = 16 Gage
Aluminum Base = 0.064
Discharge Apron = 0.064
Roof/Wall Opening = 16” SQ.
Damper Size = 15 ¾” SQ.
Max. Motor Frame Size = 56
Peak BHP = (RPM/1632)3
Max. RPM = 2440 (1 HP)
Est. Ship Weight = 109 lbs.*
* Add 8 lbs. for Heat & Smoke option.
Tip
0.250” SP
0.500” SP
0.750” SP
1.000” SP
1.250” SP
1.500” SP
1.750” SP
2.000” SP
2.250” SP
2.500” SP
HP RPM Speed
FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
3491
880
3657
920
3824
970
4031
1049
4360
1105
4592
1142
4746
1175
4883
1200
4987
1/2 1235
5133
1280
5320
1314
5461
1340
5569
1375
5715
1400
5818
1435
5964
1462
6076
1511
6280
1540
6400
1586
6592
1600
6650
1639
6812
1675
6961
1750
7273
1825
7585
1883
7826
1/4
1/3
3/4
1
1 1/2
1320
7.4 0.13
1416
8.4 0.14
1509
9.0 0.16
1624
9.2 0.19
1801
10.1 0.23
1924
10.8 0.27
2004
11.1 0.29
2075
11.5 0.32
2128
11.8 0.34
2203
12.1 0.37
2298
12.4 0.40
2369
12.6 0.43
2423
12.8 0.46
2496
13.1 0.49
2547
13.2 0.52
2620
13.5 0.56
2675
13.9 0.59
2775
14.7 0.65
2835
15.0 0.68
2928
15.5 0.74
2957
15.7 0.76
3036
16.2 0.81
3109
16.7 0.87
3261
18.0 0.98
3412
19.4 1.11
3529
21.0 1.22
794
7.0 0.13
1005
7.7 0.16
1140
8.4 0.18
1299
8.8 0.21
1518
9.8 0.26
1661
10.6 0.29
1754
10.9 0.32
1836
11.2 0.35
1897
11.6 0.37
1981
12.1 0.40
2085
12.7 0.44
2164
13.1 0.47
2224
13.4 0.50
2304
13.8 0.53
2360
14.1 0.56
2439
14.5 0.60
2500
14.9 0.63
2609
15.7 0.69
2672
15.9 0.73
2772
16.3 0.79
2802
16.4 0.81
2886
16.8 0.87
2963
17.3 0.92
3123
18.4 1.04
3282
19.7 1.17
3402
21.0 1.28
500
9.1 0.16
1105
10.0 0.26
1325
10.6 0.31
1445
11.0 0.34
1551
11.2 0.37
1626
11.4 0.39
1725
11.8 0.42
1846
12.4 0.46
1934
12.9 0.50
2000
13.3 0.53
2089
13.8 0.57
2151
14.1 0.59
2238
14.6 0.64
2305
15.0 0.67
2422
16.0 0.73
2490
16.3 0.77
2597
16.7 0.83
2629
16.9 0.85
2719
17.3 0.91
2801
17.8 0.97
2971
18.8 1.09
3139
19.9 1.22
3266
21.0 1.33
425
10.9 0.22
776
11.3 0.29
1028
11.7 0.35
1212
12.0 0.39
1382
12.4 0.43
1543
12.7 0.48
1654
13.1 0.52
1738
13.4 0.55
1847
13.8 0.59
1918
14.2 0.62
2017
14.7 0.66
2090
15.1 0.69
2217
16.0 0.76
2291
16.3 0.80
2408
16.8 0.87
2443
16.9 0.89
2540
17.3 0.95
2629
17.8 1.01
2809
18.8 1.14
2984
19.9 1.27
3117
21.0 1.38
470
12.5 0.31
896
13.1 0.42
1151
13.6 0.49
1343
14.1 0.54
1522
14.6 0.59
1622
14.7 0.63
1738
13.4 0.55
1826
15.5 0.71
1984
16.2 0.78
2073
16.5 0.82
2204
16.9 0.89
2243
17.1 0.92
2349
17.5 0.98
2442
17.9 1.04
2633
18.8 1.17
2821
19.8 1.31
2965
21.0 1.43
374
14.0 0.36
737
14.6 0.48
963
15.0 0.54
1228
15.7 0.63
1428
16.2 0.69
1686
17.0 0.79
1799
17.2 0.83
1950
17.4 0.91
1996
17.6 0.93
2121
17.9 1.00
2236
18.2 1.06
2449
18.8 1.20
2650
19.8 1.34
2798
21.0 1.46
564
16.1 0.51
1029
17.0 0.68
1253
17.6 0.76
1593
18.4 0.89
1675
18.6 0.93
1850
18.9 1.00
1981
19.0 1.07
2226
19.5 1.22
2461
20.0 1.37
2625
21.0 1.49
835
18.3 0.73
964
18.5 0.78
1285
19.1 0.91
1552
19.7 1.02
1969
21.0 1.22
2231
21.0 1.38
2419
21.0 1.51
817
19.6 0.84
1448
21.0 1.13
1955
22.0 1.38
2193
22.0 1.53
701
21.0 0.89
1381
22.0 1.24
1812
23.0 1.47
Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive
losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard
301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream.
16
www.PennBarry.com | Moving Your Way
©PENNBARRY 2014
840
Fumex | FX
30"
35"
1.600
1623 RPM
RPM
BHP
1.400
1.200
5 ¾"
5 ¾"
Do not select in shaded area.
1414 RPM
27 ¼"
28 ¾"
1.000
1230 RPM
0.800
16" x 16"
35"
1130 RPM
0.600
400
800
1200
1600
3
2000
AIRFLOW - CFM
H
P
24 ¾" x 24 ¾"
HP
0
1/
P
0.000
HP
H
4
2
1/
0.250
4
3/
0.400
1/
STATIC PRESSURE - Inches W.G.
FX13B | BELT DRIVE
2400
2800
3200
Galv. Steel Base = 16 Gage
Aluminum Base = 0.064
Discharge Apron = 0.064
Roof/Wall Opening = 16” SQ.
Damper Size = 15 ¾” SQ.
Max. Motor Frame Size = 56
Peak BHP = (RPM/1751)3
Max. RPM = 2202 (1 ½ HP)
Est. Ship Weight = 110 lbs.*
* Add 8 lbs. for Heat & Smoke option.
Tip
0.000” SP
0.250” SP
0.375” SP
0.500” SP
0.625” SP
0.750” SP
0.875” SP
1.000” SP
1.250” SP
1.375” SP
HP RPM Speed
FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
1/4
1/3
1/2
©PENNBARRY 2014
3/4
500
1800
650
2340
800
2880
978
3521
1055
3798
1130
4068
1160
4176
1185
4266
1210
4356
1230
4428
1255
4518
1280
4608
1305
4698
1330
4788
1355
4878
1375
4950
1400
5040
1414
5090
1445
5202
1470
5292
1495
5382
1525
5490
1550
5580
1575
5670
1600
5760
1623
5842
874
6.3 0.02
1137
7.0 0.04
1399
7.6 0.07
1710
11.0 0.13
1845
12.7 0.17
1976
13.5 0.20
2029
13.9 0.22
2072
14.3 0.24
2116
14.6 0.25
2151
15.0 0.26
2195
15.4 0.28
2239
15.7 0.30
2282
16.1 0.31
2326
16.3 0.33
2370
16.5 0.35
2405
16.7 0.37
2449
16.9 0.39
2473
17.1 0.40
2527
17.4 0.43
2571
17.7 0.45
2615
18.0 0.47
2667
18.5 0.50
2711
18.9 0.53
2755
19.3 0.55
2798
19.6 0.58
2839
19.9 0.60
1052
7.4 0.09
1452
10.6 0.16
1608
12.3 0.20
1755
13.1 0.24
1814
13.4 0.26
1862
13.8 0.27
1911
14.1 0.29
1950
14.4 0.30
1998
14.8 0.32
2046
15.2 0.34
2094
15.6 0.36
2142
15.8 0.38
2190
16.0 0.40
2228
16.2 0.41
2275
16.4 0.43
2302
16.6 0.45
2360
16.9 0.47
2408
17.2 0.50
2455
17.6 0.52
2511
18.0 0.55
2558
18.4 0.58
2604
18.9 0.61
2651
19.2 0.63
2694
19.4 0.66
1284
10.2 0.17
1471
12.0 0.21
1635
12.9 0.25
1699
13.2 0.27
1751
13.5 0.29
1804
13.9 0.30
1845
14.2 0.32
1895
14.6 0.34
1945
14.9 0.35
1994
15.3 0.37
2044
15.5 0.39
2093
15.7 0.41
2132
15.9 0.43
2181
16.2 0.45
2208
16.3 0.47
2269
16.6 0.49
2317
16.9 0.52
2366
17.3 0.54
2424
17.7 0.57
2472
18.1 0.60
2520
18.6 0.63
2568
18.9 0.66
2612
19.2 0.68
1026
9.7 0.17
1281
11.5 0.22
1485
12.4 0.26
1559
12.8 0.28
1619
13.1 0.30
1679
13.5 0.32
1727
13.8 0.33
1782
14.2 0.35
1835
14.6 0.37
1889
15.0 0.39
1942
15.2 0.41
1995
15.4 0.43
2037
15.6 0.45
2089
15.9 0.47
2118
16.0 0.48
2180
16.4 0.51
2230
16.7 0.54
2280
17.0 0.56
2339
17.4 0.59
2388
17.8 0.62
2437
18.3 0.65
2486
18.6 0.68
2531
18.9 0.70
928
10.9 0.21
1281
11.7 0.27
1377
12.2 0.29
1448
12.5 0.31
1519
12.9 0.32
1574
13.3 0.34
1639
13.6 0.36
1701
14.0 0.38
1762
14.4 0.40
1823
14.7 0.42
1883
15.0 0.44
1931
15.3 0.46
1985
15.5 0.49
2015
15.7 0.50
2082
16.0 0.53
2135
16.3 0.55
2188
16.7 0.58
2251
17.1 0.61
2304
17.6 0.64
2356
18.0 0.67
2406
18.3 0.70
2452
18.6 0.73
1054
11.6 0.28
1196
11.9 0.30
1303
12.3 0.33
1378
12.6 0.34
1458
13.0 0.37
1535
13.4 0.39
1606
13.8 0.41
1676
14.1 0.43
1746
14.4 0.45
1796
14.7 0.47
1858
15.0 0.50
1892
15.2 0.51
1968
15.6 0.54
2028
15.9 0.57
2088
16.3 0.60
2156
16.8 0.63
2210
17.3 0.66
2264
17.7 0.69
2317
18.0 0.72
2366
18.3 0.74
1152
12.5 0.35
1292
12.9 0.38
1401
13.2 0.41
1493
13.5 0.44
1573
13.7 0.46
1636
14.0 0.48
1708
14.3 0.50
1747
14.5 0.52
1834
15.0 0.55
1903
15.3 0.58
1965
15.7 0.60
2039
16.2 0.64
2100
16.7 0.67
2160
17.3 0.70
2220
17.6 0.73
2275
18.0 0.76
1130
13.2 0.41
1314
13.4 0.45
1413
13.6 0.48
1516
13.8 0.51
1568
13.9 0.52
1671
14.3 0.56
1749
14.6 0.59
1821
15.1 0.61
1906
15.6 0.65
1975
16.1 0.68
2043
16.7 0.71
2105
17.0 0.74
2161
17.3 0.77
1341
14.4 0.59
1521
14.7 0.65
1637
15.0 0.69
1731
15.3 0.72
1818
15.6 0.76
1892
16.0 0.79
1455
15.3 0.70
1597
15.5 0.75
1707
15.7 0.79
Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive
losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard
301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream.
www.PennBarry.com | Moving Your Way
17
Fumex | FX
STATIC PRESSURE - Inches W.G.
FX13BHFT | BELT DRIVE
3.000
2.750
2.500
2.250
2.000
1.750
1.500
1.250
1.000
0.750
0.500
0.250
0.000
35"
5 ¾"
RPM
BHP
1470 RPM
Do not select in shaded area.
1279 RPM
28 ¾"
11
1179 RPM
/2
1H
1026 RPM
3/4
892 RPM
818 RPM
0
500
1000
1/2
HP
P
HP
HP
1/
1/4 3 HP
HP
1500
2000
2500
24 ¾" x 24 ¾"
3000
AIRFLOW - CFM
3500
4000
4500
Galv. Steel Base = 16 Gage
Aluminum Base = 0.064
Discharge Apron = 0.064
Roof/Wall Opening = 16” SQ.
Damper Size = 15 ¾” SQ.
Max. Motor Frame Size = 56
Peak BHP = (RPM/1277)3
Max. RPM = 1875 (1 ½ HP)
Est. Ship Weight = 115 lbs.*
* Add 8 lbs. for Heat & Smoke option.
Tip
0.250” SP
0.500” SP
0.750” SP
1.000” SP
1.250” SP
1.500” SP
1.750” SP
2.000” SP
2.250” SP
2.500” SP
HP RPM Speed
FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
3670
818
4002
850
4159
892
4365
925
4526
950
4648
975
4771
1000
4893
1026
5020
1050
5138
1075
5260
1100
5382
1125
5505
1150
5627
1179
5769
1200
5872
1225
5994
1255
6141
1279
6258
1300
6361
1325
6483
1360
6655
1 1/2 1400
6850
1425
6973
1450
7095
1470
7193
1/3
1/2
3/4
1
1817
7.2 0.19
2046
7.9 0.25
2152
8.4 0.27
2289
9.3 0.31
2395
9.9 0.35
2476
10.3 0.38
2554
10.7 0.41
2630
11.3 0.44
2709
11.8 0.47
2782
12.3 0.50
2858
13.0 0.54
2933
13.6 0.57
3008
14.2 0.61
3083
14.5 0.65
3169
14.9 0.70
3232
15.2 0.74
3306
15.6 0.79
3396
16.1 0.84
3467
16.5 0.89
3529
16.9 0.93
3603
17.3 0.99
3706
17.9 1.07
3824
18.5 1.16
3897
18.9 1.22
3972
19.3 1.29
4032
19.5 1.34
1312
6.7 0.20
1645
7.4 0.26
1781
7.9 0.29
1953
8.8 0.33
2080
9.4 0.37
2176
9.8 0.40
2270
10.1 0.43
2360
10.6 0.46
2451
11.1 0.50
2534
11.6 0.53
2619
12.2 0.57
2705
12.8 0.60
2788
13.4 0.64
2871
13.7 0.68
2967
14.1 0.73
3036
14.4 0.77
3118
14.8 0.82
3216
15.2 0.88
3294
15.6 0.93
3362
16.0 0.97
3442
16.5 1.02
3554
17.1 1.10
3677
17.7 1.20
3753
18.1 1.26
3829
18.5 1.33
3889
18.7 1.38
915
7.2 0.23
1168
7.7 0.28
1463
8.4 0.33
1641
9.0 0.38
1769
9.4 0.41
1888
9.7 0.44
2006
10.1 0.48
2119
10.7 0.52
2218
11.2 0.55
2321
11.8 0.59
2421
12.5 0.63
2518
13.1 0.67
2613
13.4 0.71
2723
13.7 0.76
2802
14.0 0.80
2891
14.2 0.85
2996
14.6 0.91
3079
15.0 0.96
3151
15.3 1.00
3237
15.7 1.06
3355
16.2 1.14
3489
16.8 1.24
3572
17.2 1.30
3654
17.5 1.36
3720
17.8 1.42
782
8.3 0.30
1100
9.0 0.37
1298
9.4 0.41
1483
9.8 0.46
1666
10.3 0.51
1798
10.8 0.55
1932
11.3 0.59
2057
12.0 0.63
2177
12.6 0.68
2294
12.9 0.73
2422
13.3 0.78
2510
13.6 0.82
2613
13.9 0.87
2736
14.3 0.93
2830
14.6 0.98
2911
14.9 1.03
3007
15.3 1.09
3139
15.9 1.17
3288
16.5 1.27
3375
16.8 1.34
3462
17.2 1.40
3532
17.4 1.46
739
9.4 0.39
1104
10.1 0.48
1333
10.8 0.54
1529
11.3 0.60
1708
12.0 0.66
1881
12.4 0.72
2038
12.9 0.78
2150
13.2 0.82
2277
13.5 0.88
2420
13.9 0.95
2533
14.3 1.0
2631
14.6 1.06
2737
15.0 1.11
2882
15.5 1.20
3046
16.1 1.29
3145
16.5 1.36
3241
16.8 1.43
3318
17.1 1.49
828
11.1 0.51
1206
11.6 0.63
1471
12.2 0.72
1636
12.6 0.78
1819
13.1 0.85
2029
13.6 0.93
2165
14.0 0.99
2278
14.4 1.04
2411
14.8 1.11
2581
15.3 1.20
2770
15.9 1.32
2887
16.2 1.39
2992
16.5 1.46
3075
16.8 1.51
611
12.0 0.54
1054
12.5 0.70
1442
13.1 0.84
1633
13.6 0.92
1797
14.0 0.99
1978
14.5 1.07
2222
15.1 1.18
2438
15.7 1.30
2571
16.1 1.37
2697
16.4 1.45
2793
16.7 1.52
569
13.3 0.63
972
13.6 0.79
1351
14.1 0.95
1688
14.8 1.10
1997
15.5 1.25
2174
15.9 1.34
2349
16.3 1.43
2463
16.6 1.50
680
14.8 0.79
1355
15.4 1.10
1651
15.8 1.24
1849
16.2 1.34
2006
16.5 1.43
493
16.1 0.80
1028
16.2 1.08
1345
16.5 1.24
Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive
losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard
301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream.
18
www.PennBarry.com | Moving Your Way
©PENNBARRY 2014
750
1/4
Fumex | FX
1.800
5 ¾"
Do not select in shaded area.
1355 RPM
1.400
5 ¾"
RPM
BHP
1467 RPM
1.600
27 ¼"
28 ¾"
1.200
1179 RPM
1.000
16" x 16"
35"
1026 RPM
943 RPM
0.800
0.600
0.400
1/4
500
1000
1500 2000
1/
3
HP
2500
1/
2
H
P
3/
4
H
P
24 ¾" x 24 ¾"
3000 3500
AIRFLOW - CFM
P
0
HP
H
0.200
0.000
30"
35"
2.000
1
STATIC PRESSURE - Inches W.G.
FX14B | BELT DRIVE
4000
4500
Galv. Steel Base = 16 Gage
Aluminum Base = 0.064
Discharge Apron = 0.064
Roof/Wall Opening = 16” SQ.
Damper Size = 15 ¾” SQ.
Max. Motor Frame Size = 56
Peak BHP = (RPM/1462)3
Max. RPM = 2085 (1 ½ HP)
Est. Ship Weight = 112 lbs.*
* Add 11 lbs. for Heat & Smoke option.
Tip
0.000” SP
0.250” SP
0.500” SP
0.625” SP
0.750” SP
0.875” SP
1.000” SP
1.250” SP
1.375” SP
1.500” SP
HP RPM Speed
FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
400
1662
550
2286
690
2868
815
3387
880
3657
943
3919
975
4052
1/3 1000
4156
1026
4264
1050
4364
1075
4468
1100
4572
1130
4696
1160
4821
1179
4900
1210
5029
1240
5154
1270
5278
1300
5403
1330
5528
1355
5631
1385
5756
1405
5839
1430
5943
1450
6026
1467
6097
1/4
1/2
3/4
©PENNBARRY 2014
1
1061
4.8 0.02
1459
4.9 0.04
1830
7.8 0.09
2162
10.2 0.14
2334
11.8 0.18
2502
13.0 0.22
2586
13.6 0.25
2653
14.0 0.26
2722
14.3 0.29
2785
14.7 0.31
2852
15.2 0.33
2918
15.8 0.35
2998
16.6 0.38
3077
17.4 0.41
3128
18.1 0.43
3210
19.1 0.47
3290
19.4 0.50
3369
19.4 0.54
3449
19.6 0.58
3528
19.9 0.62
3595
20.0 0.66
3674
21.0 0.70
3727
21.0 0.73
3794
22.0 0.77
3847
22.0 0.81
3892
23.0 0.83
1283
6.9 0.10
1743
9.3 0.17
1955
11.1 0.21
2154
12.3 0.26
2253
12.8 0.28
2330
13.3 0.30
2410
13.7 0.32
2483
14.1 0.35
2559
14.5 0.37
2634
15.0 0.39
2724
15.9 0.43
2812
16.7 0.46
2867
17.4 0.48
2956
18.4 0.52
3043
18.7 0.55
3129
18.7 0.59
3214
18.9 0.63
3300
19.2 0.68
3371
19.6 0.72
3456
20.0 0.76
3512
20.0 0.79
3583
21.0 0.84
3639
22.0 0.87
3687
22.0 0.90
673
8.0 0.14
1367
9.8 0.21
1673
11.0 0.27
1812
11.5 0.30
1914
12.0 0.32
2019
12.5 0.35
2110
13.0 0.37
2198
13.4 0.39
2285
13.8 0.42
2388
14.6 0.45
2490
15.6 0.49
2553
16.2 0.51
2654
17.2 0.55
2750
17.5 0.59
2846
17.6 0.63
2941
17.9 0.67
3035
18.3 0.72
3113
18.6 0.76
3206
19.2 0.80
3268
19.6 0.84
3344
20.0 0.88
3405
21.0 0.91
3457
21.0 0.94
1230
10.4 0.25
1480
11.0 0.29
1615
11.5 0.32
1738
12.0 0.35
1850
12.4 0.37
1963
12.9 0.40
2067
13.3 0.43
2189
14.0 0.46
2309
14.9 0.50
2377
15.6 0.52
2485
16.6 0.56
2590
16.8 0.60
2693
17.0 0.64
2795
17.3 0.69
2893
17.7 0.73
2974
18.0 0.77
3070
18.6 0.82
3134
19.0 0.85
3214
19.7 0.90
3277
20.0 0.93
3331
21.0 0.97
887
10.8 0.27
1267
11.4 0.32
1504
12.1 0.36
1659
12.6 0.39
1791
13.0 0.43
1933
13.5 0.46
2072
14.4 0.50
2157
15.0 0.52
2284
16.1 0.57
2406
16.3 0.61
2526
16.5 0.65
2634
16.8 0.70
2738
17.1 0.74
2825
17.5 0.78
2928
18.0 0.83
2997
18.5 0.87
3081
19.1 0.91
3147
19.6 0.95
3202
20.0 0.98
838
12.2 0.32
1269
12.6 0.39
1593
13.3 0.44
1786
14.2 0.49
1889
14.9 0.52
2038
15.9 0.57
2178
16.0 0.61
2315
16.0 0.65
2439
16.2 0.70
2561
16.6 0.75
2662
17.0 0.79
2777
17.5 0.85
2848
17.9 0.88
2935
18.5 0.93
3005
19.0 0.96
3063
19.5 0.99
657
13.2 0.33
1147
13.9 0.44
1394
14.7 0.49
1718
15.8 0.54
1909
15.9 0.60
2067
15.8 0.65
2209
15.9 0.70
2349
16.2 0.75
2464
16.5 0.79
2588
17.0 0.85
2670
17.4 0.89
2771
18.0 0.93
2852
18.5 0.97
2919
19.0 1.01
812
15.8 0.48
1324
15.8 0.62
1698
15.9 0.71
1938
16.1 0.76
2126
16.3 0.83
2235
16.6 0.88
2359
17.0 0.93
2454
17.4 0.97
2533
17.8 1.01
829
15.9 0.55
1241
16.1 0.67
1665
16.3 0.79
1893
16.6 0.79
2093
16.9 0.90
2216
17.1 0.96
2309
17.4 1.00
817
16.3 0.61
1054
16.6 0.70
1529
16.9 0.84
1780
17.1 0.91
1972
17.4 0.96
Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive
losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard
301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream.
www.PennBarry.com | Moving Your Way
19
Fumex | FX
1389 RPM
2.250
2.000
RPM
BHP
1.500
6 ½"
6 ½"
Do not select in shaded area.
1261 RPM
1.750
29 ½"
31"
1098 RPM
1.250
1013 RPM
1.000
39"
20" x 20"
881 RPM
0.750
767 RPM
705 RPM
4800
HP
HP
4000
28 ½" x 28 ½"
2
3200
2
2400
AIRFLOW - CFM
1/
1600
HP
800
P
0
1/
1/
2
HP
HP 3 HP
H
4
1
1/
0.250
1
0.500
0.000
32 ½"
39"
2.500
4
3/
STATIC PRESSURE - Inches W.G.
FX16B | BELT DRIVE
5600
Galv. Steel Base = 14 Gage Roof/Wall Opening = 20” SQ.
Peak BHP = (RPM/1095)3
Aluminum Base = 0.080
Damper Size = 19 ¾” SQ.
Max. RPM = 1755 (3 HP)
Discharge Apron = 0.064
Max. Motor Frame Size = 145T Est. Ship Weight = 144 lbs.*
* Add 11 lbs. for Heat & Smoke option.
Tip
0.000” SP
0.250” SP
0.500” SP
0.625” SP
0.750” SP
1.000” SP
1.250” SP
1.375” SP
1.500” SP
1.750” SP
HP RPM Speed
FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
1/4
1/3
1/2
3/4
1
1 1/2
2446
609
2979
660
3229
705
3449
725
3547
745
3645
767
3752
800
3914
830
4061
855
4183
881
4310
920
4501
955
4672
985
4819
1013
4956
1045
5112
1070
5235
1098
5372
1140
5577
1180
5773
1220
5969
1261
6169
1295
6335
1330
6507
1365
6678
1389
6795
1999
6.0 0.08
2435
8.8 0.15
2639
9.7 0.19
2819
10.7 0.23
2899
11.1 0.25
2979
11.6 0.27
3067
12.0 0.30
3199
12.6 0.34
3319
13.2 0.38
3419
13.7 0.41
3523
14.3 0.45
3679
15.3 0.51
3819
16.3 0.57
3939
17.0 0.63
4051
17.5 0.68
4179
18.2 0.75
4279
18.7 0.81
4391
19.4 0.87
4559
21.0 0.97
4719
22.0 1.08
4879
23.0 1.19
5043
24.0 1.32
5179
25.0 1.43
5318
26.0 1.55
5458
26.0 1.67
5554
27.0 1.76
1280
5.2 0.09
1951
8.1 0.17
2213
9.2 0.21
2426
10.1 0.26
2518
10.6 0.28
2611
11.1 0.30
2712
11.5 0.33
2862
11.9 0.37
2997
12.4 0.41
3106
12.9 0.45
3219
13.5 0.49
3387
14.4 0.55
3536
15.5 0.61
3664
16.1 0.67
3783
16.6 0.72
3918
17.2 0.79
4023
17.8 0.84
4141
18.5 0.91
4317
19.9 1.01
4484
21.0 1.12
4652
22.0 1.23
4823
23.0 1.36
4965
24.0 1.47
5111
25.0 1.59
5256
25.0 1.72
5355
26.0 1.81
1791
8.1 0.26
1971
8.6 0.29
2111
9.2 0.32
2247
9.8 0.34
2434
10.5 0.39
2596
11.2 0.43
2727
11.7 0.47
2862
12.3 0.51
3062
13.3 0.57
3233
14.4 0.64
3374
15.0 0.70
3505
15.6 0.76
3653
16.2 0.83
3768
16.8 0.89
3896
17.7 0.96
4087
19.1 1.07
4267
20.0 1.18
4440
22.0 1.29
4617
22.0 1.42
4764
23.0 1.53
4913
24.0 1.65
5063
25.0 1.78
5165
25.0 1.87
1770
8.6 0.33
2109
9.4 0.39
2342
10.2 0.44
2497
10.9 0.48
2645
11.6 0.52
2860
12.6 0.58
3044
13.7 0.65
3200
14.4 0.71
3344
15.0 0.77
3506
15.7 0.84
3626
16.3 0.90
3757
17.2 0.97
3953
18.6 1.08
4138
20.0 1.19
4321
21.0 1.31
4508
22.0 1.44
4661
23.0 1.56
4817
23.0 1.68
4969
24.0 1.81
5073
25.0 1.90
1791
9.2 0.41
2109
9.8 0.46
2352
10.6 0.52
2635
11.9 0.60
2841
13.0 0.66
3010
13.8 0.72
3160
14.4 0.78
3329
15.1 0.85
3459
15.7 0.91
3603
16.6 0.98
3817
18.1 1.09
4009
19.4 1.20
4196
21.0 1.33
4387
21.0 1.46
4544
22.0 1.57
4704
23.0 1.70
4864
24.0 1.83
4972
24.0 1.93
2011
11.1 0.61
2412
11.8 0.71
2678
12.7 0.79
2930
13.7 0.87
3092
14.4 0.94
3253
15.3 1.00
3491
16.9 1.11
3704
18.3 1.23
3913
19.5 1.35
4125
20.0 1.48
4299
21.0 1.60
4475
22.0 1.73
4641
23.0 1.86
4753
23.0 1.96
2287
12.8 0.86
2662
13.4 0.98
3060
15.0 1.13
3352
16.8 1.26
3594
18.1 1.38
3827
19.2 1.51
4012
20.0 1.63
4197
21.0 1.76
4380
22.0 1.89
4505
22.0 1.99
2656
14.1 1.08
3069
15.7 1.24
3397
17.3 1.39
3663
18.4 1.53
3858
19.3 1.65
4055
20.0 1.77
4244
21.0 1.90
4371
22.0 2.00
2634
14.9 1.18
3093
16.2 1.36
3453
17.5 1.53
3687
18.5 1.66
3900
19.5 1.79
4100
21.0 1.92
4235
21.0 2.02
2609
16.4 1.39
3102
17.0 1.60
3452
17.7 1.77
3751
18.8 1.94
3920
19.7 2.05
Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive
losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard
301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream.
20
www.PennBarry.com | Moving Your Way
©PENNBARRY 2014
2
500
Fumex | FX
2.250
1268 RPM
2.000
1.500
6 ½"
6 ½"
RPM
BHP
Do not select in shaded area.
1151 RPM
1.750
29 ½"
31"
1002 RPM
1.250
39"
20" x 20"
924 RPM
1.000
804 RPM
0.750
700 RPM
643 RPM
1600
2400
3200
1/
2
HP
1
3/
4
4000
AIRFLOW - CFM
HP
HP
4800
5600
28 ½" x 28 ½"
HP
800
P
HP
0
1/
HP 3 H
2
1/4
0.250
2
1/
0.500
0.000
32 ½"
39"
2.500
1
STATIC PRESSURE - Inches W.G.
FX18B | BELT DRIVE
6400
Galv. Steel Base = 14 Gage Roof/Wall Opening = 20” SQ.
Peak BHP = (RPM/999)3
Aluminum Base = 0.080
Damper Size = 19 ¾” SQ.
Max. RPM = 1403 (2 HP)
Discharge Apron = 0.064
Max. Motor Frame Size = 145T Est. Ship Weight = 145 lbs.*
* Add 20 lbs. for Heat & Smoke option.
Tip
0.000” SP
0.250” SP
0.500” SP
0.625” SP
0.750” SP
1.000” SP
1.250” SP
1.375” SP
1.500” SP
1.750” SP
HP RPM Speed
FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
1/4
1/3
1/2
3/4
1
©PENNBARRY 2014
1 1/2
2
400
2121
556
2948
600
3181
643
3409
665
3525
685
3631
700
3711
730
3870
760
4029
785
4162
804
4262
840
4453
870
4612
900
4771
924
4899
950
5036
975
5169
1002
5312
1040
5513
1080
5726
1120
5938
1151
6102
1190
6309
1215
6441
1245
6600
1268
6722
1984
4.7 0.05
2758
8.9 0.15
2976
10.0 0.18
3189
11.1 0.23
3299
11.6 0.25
3398
12.0 0.27
3472
12.3 0.29
3621
13.2 0.33
3770
14.2 0.37
3894
15.1 0.41
3988
15.9 0.44
4167
16.7 0.50
4316
17.2 0.56
4464
17.6 0.62
4584
18.3 0.67
4712
19.2 0.73
4837
20.0 0.79
4970
21.0 0.85
5159
22.0 0.95
5357
22.0 1.07
5556
23.0 1.19
5710
24.0 1.29
5903
24.0 1.43
6027
25.0 1.52
6176
26.0 1.64
6290
26.0 1.73
2050
7.9 0.17
2345
9.0 0.21
2618
10.3 0.26
2755
10.8 0.28
2873
11.2 0.31
2961
11.7 0.33
3136
12.6 0.37
3309
13.7 0.42
3452
14.7 0.46
3559
15.5 0.49
3759
16.3 0.56
3922
16.8 0.61
4084
17.3 0.68
4212
17.8 0.73
4351
18.7 0.79
4485
19.6 0.85
4628
20.0 0.92
4829
21.0 1.02
5039
22.0 1.14
5249
23.0 1.26
5411
23.0 1.37
5614
24.0 1.51
5744
25.0 1.60
5899
25.0 1.72
6019
26.0 1.81
1885
9.8 0.28
2147
10.4 0.32
2279
10.7 0.35
2503
11.7 0.39
2716
12.8 0.44
2890
13.9 0.48
3021
14.8 0.52
3261
15.6 0.59
3454
16.1 0.65
3643
16.6 0.71
3794
17.1 0.76
3952
18.0 0.83
4100
18.9 0.89
4258
19.9 0.96
4479
21.0 1.07
4709
21.0 1.20
4937
22.0 1.33
5113
23.0 1.44
5327
24.0 1.58
5463
24.0 1.67
5625
25.0 1.79
5749
25.0 1.89
2328
12.3 0.44
2569
13.4 0.49
2710
14.3 0.52
2968
15.1 0.59
3179
15.6 0.66
3385
16.2 0.72
3548
16.6 0.78
3716
17.4 0.84
3876
18.3 0.91
4047
19.4 0.98
4285
20.0 1.09
4525
21.0 1.21
4759
22.0 1.35
4940
22.0 1.46
5165
23.0 1.60
5308
24.0 1.70
5479
25.0 1.83
5610
25.0 1.92
2640
14.6 0.59
2891
15.1 0.66
3108
15.7 0.73
3279
16.1 0.79
3461
16.9 0.86
3634
17.8 0.92
3818
18.9 1.00
4067
19.7 1.11
4322
20.0 1.23
4574
21.0 1.36
4767
22.0 1.47
4997
23.0 1.62
5144
23.0 1.72
5319
24.0 1.84
5453
25.0 1.94
2805
15.7 0.84
3093
16.7 0.93
3319
17.7 1.01
3595
18.5 1.13
3878
19.3 1.26
4156
20.0 1.40
4368
21.0 1.51
4626
22.0 1.66
4786
22.0 1.76
4977
23.0 1.89
5123
24.0 1.99
3357
18.3 1.26
3709
18.9 1.42
3935
19.5 1.53
4213
21.0 1.69
4388
21.0 1.79
4597
22.0 1.92
4755
23.0 2.03
3364
18.7 1.39
3696
19.2 1.53
4002
20.0 1.70
4183
21.0 1.80
4397
22.0 1.93
4558
22.0 2.04
3752
19.8 1.69
3970
20.0 1.81
4195
21.0 1.94
4362
22.0 2.05
3541
21.0 1.87
3850
21.0 2.03
Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive
losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard
301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream.
www.PennBarry.com | Moving Your Way
21
Fumex | FX
39"
4.000
3.500
1606 RPM
Do not select in shaded area.
3.000
29 ½"
2.500
1401 RPM
2.000
1270 RPM
1.500
1105 RPM
1019 RPM
1.000
886 RPM
770 RPM
0
31"
1
1/
2
HP
1/2
1
3
HP
1/3
HP /4 H
HP
P
1000
2000
3000
4000
5000
AIRFLOW - CFM
2
HP
6000
39"
20" x 20"
28 ½" x 28 ½"
HP
0.500
0.000
32 ½"
6 ½"
6 ½"
RPM
BHP
3
STATIC PRESSURE - Inches W.G.
FX18BH | BELT DRIVE
7000
8000
Galv. Steel Base = 14 Gage Roof/Wall Opening = 20” SQ.
Peak BHP = (RPM/1106)3
Aluminum Base = 0.080
Damper Size = 19 ¾” SQ.
Max. RPM = 1870 (3 HP)
Discharge Apron = 0.064
Max. Motor Frame Size = 145T Wall Mounted Max. HP = 2
Est. Ship Weight = 142 lbs. (Add 20 lbs. for Heat & Smoke option.)
Tip
0.500” SP
0.750” SP
1.000” SP
1.250” SP
1.500” SP
1.750” SP
2.000” SP
2.250” SP
2.500” SP
3.000” SP
HP RPM Speed
FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
1/3
1/2
3/4
1
1 1/2
2
3
4082
800
4241
840
4453
886
4697
915
4851
970
5142
1019
5402
1065
5646
1080
5726
1105
5858
1125
5964
1150
6097
1175
6229
1200
6362
1225
6494
1270
6733
1280
6786
1335
7077
1375
7289
1401
7427
1440
7634
1480
7846
1520
8058
1560
8270
1585
8403
1606
8514
2308
7.6 0.33
2520
7.9 0.37
2773
8.4 0.42
3028
9.4 0.48
3186
10.1 0.53
3475
11.5 0.62
3712
12.4 0.71
3932
13.0 0.81
4003
13.2 0.84
4121
13.5 0.90
4216
13.9 0.94
4333
14.2 1.00
4450
14.7 1.07
4570
15.3 1.13
4697
16.1 1.18
4925
17.0 1.29
4975
17.1 1.32
5251
18.4 1.46
5449
19.4 1.57
5578
20.0 1.64
5770
21.0 1.76
5958
22.0 1.89
6139
24.0 2.03
6321
25.0 2.19
6434
26.0 2.28
6528
27.0 2.37
1622
8.1 0.36
2108
8.9 0.44
2436
9.4 0.52
2628
9.9 0.57
3017
10.7 0.66
3342
11.3 0.75
3598
11.9 0.85
3681
12.2 0.88
3818
12.6 0.93
3926
12.9 0.98
4061
13.4 1.04
4193
14.0 1.11
4315
14.5 1.17
4436
15.2 1.24
4652
16.2 1.38
4700
16.3 1.41
4961
17.2 1.58
5150
18.2 1.72
5272
18.8 1.82
5454
19.8 1.96
5650
21.0 2.11
5853
22.0 2.24
6055
24.0 2.39
6181
25.0 2.48
6286
25.0 2.56
1676
10.0 0.52
2435
11.5 0.68
2786
12.0 0.79
3093
12.4 0.89
3200
12.5 0.93
3378
12.7 0.98
3519
12.8 1.03
3693
13.0 1.09
3850
13.3 1.15
3990
13.6 1.22
4129
14.3 1.29
4376
15.3 1.42
4430
15.5 1.45
4728
16.6 1.63
4931
17.6 1.77
5057
18.2 1.86
5245
19.3 2.01
5436
20.0 2.17
5627
22.0 2.34
5816
23.0 2.52
5934
24.0 2.64
6032
24.0 2.74
1779
12.1 0.71
2515
13.3 0.88
2675
13.6 0.93
2884
13.7 1.00
3019
13.9 1.06
3186
14.1 1.13
3352
14.3 1.20
3525
14.6 1.28
3703
14.9 1.34
4019
15.3 1.47
4089
15.4 1.50
4424
16.1 1.68
4646
17.1 1.82
4789
17.8 1.91
5002
18.8 2.06
5218
20.0 2.22
5428
21.0 2.39
5623
23.0 2.57
5744
24.0 2.69
5845
24.0 2.79
1361
13.4 0.73
2151
14.1 0.98
2575
14.8 1.10
2844
15.5 1.19
3088
15.7 1.29
3258
16.0 1.37
3559
16.5 1.52
3625
16.6 1.56
4008
17.1 1.74
4290
17.5 1.88
4471
17.9 1.97
4720
18.7 2.12
4944
19.7 2.28
5165
21.0 2.45
5385
23.0 2.63
5520
23.0 2.75
5634
24.0 2.85
1920
15.5 1.11
2544
16.4 1.3
3081
17.7 1.51
3188
17.9 1.55
3599
18.4 1.77
3865
18.8 1.93
4036
19.1 2.04
4315
19.6 2.19
4598
20.0 2.35
4876
21.0 2.51
5124
22.0 2.69
5264
23.0 2.81
5381
24.0 2.91
1895
17.3 1.28
3051
19.2 1.73
3478
20.0 1.93
3670
20.0 2.05
3933
21.0 2.22
4198
21.0 2.41
4474
22.0 2.59
4759
23.0 2.77
4935
23.0 2.88
5081
24.0 2.98
2571
19.9 1.78
3073
21.0 1.98
3494
22.0 2.20
3852
23.0 2.41
4122
23.0 2.61
4389
24.0 2.82
4553
24.0 2.96
4700
25.0 3.06
2481
22.0 1.98
3274
23.0 2.34
3705
25.0 2.59
4060
25.0 2.83
4230
26.0 2.96
4371
26.0 3.08
1714
24.0 1.93
2907
26.0 2.71
3378
27.0 2.95
Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive
losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard
301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream.
22
www.PennBarry.com | Moving Your Way
©PENNBARRY 2014
770
Fumex | FX
STATIC PRESSURE - Inches W.G.
FX24B | BELT DRIVE
46"
3.500
1237 RPM
3.000
36"
7"
RPM
BHP
7"
Do not select in shaded area.
35 ⅞"
2.500
1042 RPM
2.000
1.500
825 RPM
3
710 RPM
662 RPM
576 RPM
501 RPM
1.000
0.500
0.000
5
909 RPM
0
1
1/3
2000
3/4 1 HP
1/2 HP
HP HP
4000
1/
2
2
HP
34 ½"
H
P
25" x 25"
46"
H
P
HP
6000
33 ½" x 33 ½"
8000
AIRFLOW - CFM
10000
12000
Galv. Steel Base = 14 Gage Roof/Wall Opening = 25” SQ.
Peak BHP = (RPM/716)3
Aluminum Base = 0.080
Damper Size = 24 ¾” SQ.
Max. RPM = 1360 (5 HP)
Discharge Apron = 0.064
Max. Motor Frame Size = 184T Wall Mounted Max. HP = 2
Est. Ship Weight = 190 lbs. (Add 40 lbs. for Heat & Smoke option.)
Tip
0.250” SP
0.500” SP
0.750” SP
1.000” SP
1.250” SP
1.500” SP
1.750” SP
2.000” SP
2.250” SP
2.500” SP
HP RPM Speed
FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
375
2436
420
2728
461
2995
480
3118
501
3255
540
3508
576
3742
610
3963
640
4157
662
4300
690
4482
718
4664
755
4905
1 1/2 790
5132
825
5359
850
5522
880
5717
909
5905
950
6171
985
6399
1015
6593
1042
6769
1100
7146
1150
7470
1200
7795
1237
8036
1/4
1/3
1/2
3/4
1
2
©PENNBARRY 2014
3
5
1986
5.9 0.14
2701
7.3 0.20
3245
8.7 0.27
3471
9.5 0.30
3717
10.4 0.34
4163
11.9 0.42
4543
12.9 0.51
4896
14.0 0.60
5203
14.9 0.69
5421
15.5 0.76
5697
16.2 0.85
5972
16.9 0.95
6332
18.2 1.10
6670
19.7 1.25
7007
21.0 1.42
7246
21.0 1.55
7532
22.0 1.71
7808
23.0 1.88
8197
25.0 2.14
8527
28.0 2.37
8809
29.0 2.59
9062
29.0 2.80
9605
30.0 3.28
10071
32.0 3.74
10536
34.0 4.23
10879
36.0 4.63
2992
10.7 0.42
3557
11.7 0.52
4036
12.9 0.62
4433
14.0 0.72
4709
14.7 0.79
5040
15.4 0.89
5367
16.2 1.00
5791
17.4 1.16
6167
19.0 1.32
6534
19.9 1.49
6793
20.0 1.62
7103
21.0 1.79
7397
23.0 1.97
7803
25.0 2.23
8148
27.0 2.47
8441
28.0 2.69
8705
29.0 2.90
9267
30.0 3.39
9749
31.0 3.85
10228
33.0 4.35
10581
35.0 4.75
3236
12.8 0.67
3676
13.6 0.77
4126
14.3 0.89
4542
15.1 1.01
5049
16.4 1.18
5510
18.1 1.35
5937
19.0 1.53
6231
19.5 1.67
6580
20.0 1.84
6913
22.0 2.03
7367
24.0 2.30
7736
26.0 2.55
8050
27.0 2.78
8330
28.0 2.99
8927
29.0 3.50
9424
30.0 3.96
9916
33.0 4.47
10279
35.0 4.87
3116
13.9 0.88
4070
15.3 1.12
4663
16.9 1.33
5185
18.0 1.53
5538
18.5 1.68
5939
19.3 1.87
6321
21.0 2.06
6824
23.0 2.34
7236
25.0 2.60
7585
26.0 2.83
7896
27.0 3.05
8539
28.0 3.57
9065
29.0 4.05
9586
32.0 4.57
9968
34.0 4.99
4151
16.8 1.43
4660
17.5 1.61
5165
18.3 1.83
5599
19.6 2.04
6187
22.0 2.35
6655
24.0 2.62
7050
25.0 2.86
7390
26.0 3.09
8076
27.0 3.62
8656
28.0 4.11
9227
31.0 4.65
9623
33.0 5.07
3845
17.3 1.63
4660
18.4 1.92
5435
21.0 2.29
5973
23.0 2.59
6417
24.0 2.86
6795
25.0 3.10
7568
26.0 3.65
8197
27.0 4.16
8788
30.0 4.70
9219
32.0 5.13
4130
19.3 2.05
5102
22.0 2.45
5681
23.0 2.77
6123
24.0 3.04
6985
25.0 3.64
7669
26.0 4.17
8330
29.0 4.73
8793
31.0 5.18
4389
22.0 2.49
5217
23.0 2.87
6327
24.0 3.56
7085
25.0 4.13
7804
28.0 4.73
8300
30.0 5.18
5393
23.0 3.35
6427
25.0 4.02
7221
27.0 4.67
7770
29.0 5.16
5428
24.0 3.77
6552
26.0 4.53
7190
28.0 5.08
Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive
losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard
301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream.
www.PennBarry.com | Moving Your Way
23
Fumex | FX
STATIC PRESSURE - Inches W.G.
FX24BH | BELT DRIVE
46"
4.500
1429 RPM
4.000
3.500
7"
Do not select in shaded area.
1203 RPM
3.000
2.500
5
1049 RPM
2.000
3
951 RPM
1.500
0.500
0
35 ⅞"
HP
34 ½"
2000
4000
25" x 25"
46"
HP
2H
P
11
/2
HP
1H
P
3/4
1/2 HP
HP
828 RPM
763 RPM
663 RPM
1.000
0.000
36"
7"
RPM
BHP
33 ½" x 33 ½"
6000
AIRFLOW - CFM
8000
10000
Galv. Steel Base = 14 Gage
Roof Opening = 25” SQ.
Peak BHP = (RPM/827)3
Aluminum Base = 0.080
Damper Size = 24 ¾” SQ.
Max. RPM = 1620 (5 HP)
Discharge Apron = 0.064
Max. Motor Frame Size = 184T Wall Mounted Max. HP = 2
Est. Ship Weight = 187 lbs. (Add 40 lbs. for Heat & Smoke option.)
Tip
0.500” SP
0.750” SP
1.000” SP
1.250” SP
1.500” SP
1.750” SP
2.000” SP
2.250” SP
2.500” SP
3.000” SP
HP RPM Speed
FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
3897
663
4306
707
4592
725
4709
763
4956
800
5196
828
5378
855
5553
886
5755
1 1/2 915
5943
925
6008
951
6177
990
6430
1019
6619
1049
6814
1080
7015
1105
7177
1125
7307
1175
7632
1203
7814
1210
7859
1245
8087
1275
8281
1325
8606
1380
8963
1429
9282
3/4
1
2
3
5
2641
8.9 0.38
3231
10.0 0.51
3633
10.8 0.61
3774
11.1 0.65
4069
11.9 0.75
4351
12.4 0.86
4549
12.7 0.94
4736
13.1 1.03
4950
13.7 1.13
5148
14.7 1.23
5216
15.2 1.27
5393
16.0 1.37
5657
16.9 1.53
5856
17.4 1.66
6063
18.0 1.80
6276
18.8 1.95
6447
19.5 2.08
6583
20.0 2.19
6923
22.0 2.48
7122
23.0 2.65
7160
23.0 2.69
7395
24.0 2.92
7597
24.0 3.12
7931
25.0 3.49
8298
27.0 3.92
8623
29.0 4.33
2472
10.3 0.51
2971
11.0 0.63
3142
11.3 0.67
3497
12.0 0.78
3844
12.5 0.89
4107
12.8 0.98
4357
13.1 1.07
4607
13.7 1.19
4833
14.6 1.30
4910
15.0 1.34
5110
15.7 1.45
5403
16.5 1.62
5605
16.9 1.75
5813
17.4 1.89
6027
18.0 2.05
6198
18.6 2.18
6335
19.3 2.29
6675
21.0 2.58
6864
22.0 2.76
6911
22.0 2.80
7152
23.0 3.03
7359
23.0 3.24
7702
24.0 3.61
8078
26.0 4.04
8411
28.0 4.46
1877
10.8 0.56
2264
11.4 0.64
2824
12.3 0.78
3259
12.6 0.91
3542
12.9 1.00
3796
13.3 1.10
4083
13.7 1.22
4355
14.6 1.34
4450
15.0 1.38
4695
15.7 1.49
5056
16.5 1.67
5288
16.9 1.81
5522
17.4 1.96
5761
18.0 2.13
5953
18.6 2.32
6105
19.1 2.39
6461
21.0 2.69
6655
21.0 2.86
6704
21.0 2.91
6945
22.0 3.14
7151
23.0 3.35
7492
24.0 3.73
7865
25.0 4.17
8198
27.0 4.59
2352
12.7 0.85
2822
13.4 0.98
3180
13.6 1.09
3546
14.0 1.23
3857
14.6 1.35
3953
14.9 1.40
4198
15.6 1.51
4560
16.5 1.70
4831
16.9 1.85
5115
17.4 2.00
5405
18.0 2.18
5635
18.6 2.32
5801
19.1 2.44
6191
21.0 2.75
6407
21.0 2.94
6461
21.0 2.99
6728
22.0 3.24
6954
23.0 3.47
7302
23.0 3.84
7683
25.0 4.29
8019
26.0 4.72
1929
13.3 0.93
2740
14.3 1.17
3223
14.9 1.33
3345
15.0 1.38
3655
15.5 1.51
4107
16.5 1.72
4384
17.0 1.87
4667
17.5 2.03
4954
18.1 2.21
5184
18.6 2.36
5375
19.1 2.48
5846
21.0 2.80
6105
21.0 3.00
6169
21.0 3.05
6453
22.0 3.30
6688
23.0 3.53
7074
23.0 3.93
7493
25.0 4.41
7843
26.0 4.84
2152
14.8 1.20
2859
15.8 1.43
3503
16.7 1.69
3851
17.2 1.85
4203
17.8 2.04
4539
18.4 2.23
4777
18.9 2.38
4965
19.3 2.51
5429
20.0 2.84
5690
21.0 3.04
5757
21.0 3.09
6088
22.0 3.35
6368
22.0 3.58
6815
23.0 3.99
7246
25.0 4.47
7624
26.0 4.93
2353
16.5 1.48
3096
17.5 1.76
3597
18.3 1.99
4005
18.8 2.20
4301
19.3 2.73
4535
19.7 2.51
5047
21.0 2.86
5311
21.0 3.07
5377
21.0 3.12
5701
22.0 3.39
5977
23.0 3.63
6453
23.0 4.04
6965
25.0 4.53
7384
26.0 4.99
2447
17.9 1.75
3270
19.1 2.10
2689
19.9 2.31
4002
20.0 2.48
4597
21.0 2.85
4924
22.0 3.08
5004
22.0 3.14
5341
22.0 3.41
5624
23.0 3.65
6088
24.0 4.08
6604
25.0 4.58
7065
26.0 5.05
2546
19.4 2.03
3184
20.0 2.32
4058
22.0 2.80
4425
22.0 3.04
4508
22.0 3.10
4922
23.0 3.40
5270
23.0 3.67
5750
24.0 4.10
6264
25.0 4.62
6717
26.0 5.05
2767
22.0 2.65
3740
24.0 3.21
4244
25.0 3.54
4933
26.0 4.07
5580
26.0 4.64
6086
27.0 5.16
Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive
losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard
301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream.
24
www.PennBarry.com | Moving Your Way
©PENNBARRY 2014
600
1/2
Fumex | FX
STATIC PRESSURE - Inches W.G.
FX27B | BELT DRIVE
3.000
53 ½"
1091 RPM
RPM
BHP
2.500
Do not select in shaded area.
921 RPM
2.000
1.500
804 RPM
1.000
638 RPM
580 RPM
507 RPM
442 RPM
5
3
731 RPM
0.500
0.000
6 ½"
0
2
11
1H
/2
3/4
P
HP
1/
1/3 2 HP
HP
2000
4000
H
P
35 ½"
HP
HP
HP
36 ½" x 36 ½"
6000
8000
AIRFLOW - CFM
10000
Galv. Steel Base = 14 Gage
Roof Opening = 28” SQ.
Peak BHP = (RPM/539)3
Aluminum Base = 0.080
Damper Size = 27 ¾” SQ.
Max. RPM = 1188 (5 HP)
Discharge Apron = 0.080
Max. Motor Frame Size = 184T Est. Ship Weight = 219 lbs.*
12000
* Add 55 lbs. for Heat & Smoke option.
Tip
0.125” SP
HP RPM Speed
FPM Sones BHP
1/3
1/2
3/4
1
1 1/2
2
3
©PENNBARRY 2014
5
442
3211
475
3451
507
3683
535
3887
560
4068
580
4214
600
4359
620
4504
638
4635
660
4795
685
4976
705
5122
731
5311
750
5449
770
5594
785
5703
804
5841
830
6030
865
6284
895
6502
921
6691
960
6974
1000
7265
1045
7592
1091
7926
4361
8.3 0.30
4780
9.7 0.37
5120
10.7 0.44
5444
11.7 0.51
4361
12.7 0.59
5960
13.5 0.65
6188
14.2 0.71
6415
14.9 0.78
6631
15.4 0.85
6868
15.9 0.94
7150
16.7 1.04
7374
17.4 1.13
7666
18.4 1.26
7879
19.0 1.35
8103
19.6 1.46
8270
20.0 1.54
8482
21.0 1.66
8772
22.0 1.82
9161
23.0 2.05
9493
25.0 2.26
9782
26.0 2.46
10213
28.0 2.78
10655
30.0 3.14
11151
31.0 3.57
11658
34.0 4.05
0.250” SP
Sones
BHP
3843
7.7 0.33
4293
9.0 0.40
4710
10.1 0.48
5065
11.1 0.55
4361
12.2 0.63
5628
13.1 0.69
5870
13.8 0.76
6107
14.6 0.83
6330
15.0 0.90
6577
15.7 0.99
6869
16.4 1.10
7101
17.1 1.19
7403
18.1 1.32
7622
18.7 1.42
7853
19.3 1.53
8025
19.8 1.62
8243
20.0 1.73
8540
21.0 1.89
8938
23.0 2.13
9278
24.0 2.35
9573
26.0 2.55
10013
27.0 2.87
10463
29.0 3.23
10967
31.0 3.66
11482
33.0 4.15
0.375” SP
Sones
BHP
3112
7.1 0.33
3695
8.6 0.41
4213
9.8 0.50
4617
10.7 0.58
4361
11.7 0.66
5234
12.7 0.73
5498
13.4 0.80
5756
14.2 0.87
5990
14.6 0.94
6264
15.2 1.04
6578
16.0 1.15
6827
16.7 1.24
7144
17.7 1.38
7369
18.4 1.48
7605
18.9 1.59
7782
19.4 1.68
8004
19.9 1.80
8308
21.0 1.97
8716
22.0 2.21
9063
24.0 2.43
9364
25.0 2.63
9812
27.0 2.96
10270
29.0 3.32
10783
31.0 3.76
11305
33.0 4.25
0.500” SP
Sones
BHP
2634
7.6 0.38
3530
9.2 0.49
4030
10.3 0.59
4361
11.5 0.67
4785
12.5 0.75
5076
13.2 0.82
5363
13.8 0.90
5625
14.3 0.98
5913
14.8 1.07
6248
15.6 1.19
6506
16.3 1.29
6839
17.4 1.42
7080
18.0 1.53
7332
18.5 1.64
7521
18.9 1.73
7758
19.5 1.85
8080
22.0 2.00
8497
22.0 2.27
8851
23.0 2.50
9156
25.0 2.71
9612
26.0 3.04
10078
28.0 3.41
10599
30.0 3.85
11129
33.0 4.35
0.750” SP
Sones
BHP
3159
10.9 0.69
3889
12.0 0.80
4304
12.9 0.90
4635
13.5 0.99
5018
14.2 1.10
5461
15.0 1.24
5782
15.7 1.34
6161
16.7 1.49
6434
17.4 1.60
6719
17.9 1.72
6925
18.3 1.82
7183
18.8 1.94
7534
19.6 2.12
7988
21.0 2.38
8372
22.0 2.61
8702
24.0 2.82
9193
25.0 3.17
9691
27.0 3.55
10236
29.0 4.01
10780
31.0 4.53
1.000” SP
Sones
BHP
4209
13.8 1.17
4753
14.7 1.31
5247
15.8 1.48
5583
16.6 1.61
5932
17.3 1.76
6200
17.8 1.86
6528
18.4 2.00
6910
18.9 2.18
7415
20.0 2.46
7840
22.0 2.70
8195
23.0 2.93
8720
25.0 3.28
9239
26.0 3.67
9814
28.0 4.14
10395
31.0 4.66
1.250” SP
Sones
BHP
4127
15.0 1.49
4856
16.0 1.67
5250
16.6 1.81
5628
17.3 1.97
6092
18.1 2.18
6706
19.7 2.49
7239
21.0 2.75
7624
23.0 2.99
8189
24.0 3.36
8757
26.0 3.77
9369
28.0 4.26
9981
30.0 4.80
1.500” SP
Sones
BHP
4830
16.9 2.05
5853
18.6 2.43
6421
20.0 2.73
6881
22.0 2.99
7568
24.0 3.40
8221
25.0 3.83
8875
27.0 4.34
9531
29.0 4.91
2.000” SP
Sones
BHP
5162
18.4 2.56
6055
20.0 2.90
6816
22.0 3.36
7523
24.0 3.83
8318
26.0 4.39
9039
29.0 4.96
Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive
losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard
301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream.
www.PennBarry.com | Moving Your Way
25
Fumex | FX
STATIC PRESSURE - Inches W.G.
FX30B | BELT DRIVE
2.750
2.500
2.250
2.000
1.750
1.500
1.250
1.000
0.750
0.500
0.250
0.000
53 ½"
931 RPM
6 ½"
RPM
BHP
Do not select in shaded area.
5
784 RPM
684 RPM
3
621 RPM
11
541 RPM
498 RPM
1
3/4 HP
1/2 HP
H
1/3
P
HP
434 RPM
377 RPM
0
2000
4000
/2
2H
HP
35 ½"
HP
P
HP
36 ½" x 36 ½"
6000
8000
10000 12000 14000 16000
AIRFLOW - CFM
Galv. Steel Base = 14 Gage
Roof Opening = 28” SQ.
Peak BHP = (RPM/539)3
Aluminum Base = 0.080
Damper Size = 27 ¾” SQ.
Max. RPM = 1188 (5 HP)
Discharge Apron = 0.080
Max. Motor Frame Size = 184T Est. Ship Weight = 219 lbs.*
* Add 65 lbs. for Heat & Smoke option.
Tip
0.000” SP
0.250” SP
0.500” SP
0.750” SP
1.000” SP
1.250” SP
1.500” SP
1.750” SP
2.000” SP
2.250” SP
HP RPM Speed
FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
2782
377
3023
400
3207
420
3367
434
3480
455
3648
480
3848
498
3993
520
4169
541
4338
560
4490
1 1/2 595
4770
621
4979
640
5131
665
5332
684
5484
710
5693
730
5853
750
6013
770
6174
784
6286
805
6454
840
6735
880
7055
915
7336
931
7464
1/2
3/4
1
2
3
5
5314
7.6 0.22
5773
8.9 0.28
6125
10.1 0.33
6431
10.9 0.38
6646
11.6 0.42
6968
12.5 0.49
7350
13.7 0.57
7626
14.6 0.64
7963
15.6 0.73
8285
16.4 0.82
8576
17.1 0.91
9112
18.5 1.09
9510
19.7 1.24
9801
21.0 1.35
10184
22.0 1.52
10474
22.0 1.65
10873
23.0 1.85
11179
24.0 2.01
11485
25.0 2.18
11792
26.0 2.36
12006
27.0 2.49
12328
28.0 2.69
12863
30.0 3.06
13476
31.0 3.52
14012
33.0 3.96
14257
34.0 4.17
3779
7.2 0.27
4431
8.5 0.34
4899
9.5 0.40
5283
10.2 0.46
5548
10.7 0.50
5937
11.6 0.57
6377
12.8 0.66
6690
13.6 0.74
7069
14.6 0.83
7428
15.4 0.93
7748
16.1 1.02
8333
17.5 1.21
8764
18.8 1.36
9077
19.6 1.48
9488
21.0 1.79
9798
21.0 1.79
10221
22.0 1.99
10545
23.0 2.15
10869
24.0 2.33
11191
25.0 2.51
11416
26.0 2.64
11753
27.0 2.85
12313
29.0 3.22
12951
30.0 3.69
13507
32.0 4.13
13760
34.0 4.35
3742
10.0 0.51
4445
10.8 0.61
5078
11.9 0.71
5505
12.7 0.79
5984
13.8 0.90
6433
14.6 1.00
6818
15.2 1.10
7491
16.5 1.30
7983
17.8 1.46
8335
18.6 1.59
8776
19.7 1.77
9109
20.0 1.92
9560
21.0 2.13
9905
22.0 2.30
10248
23.0 2.49
10588
24.0 2.68
10824
25.0 2.81
11177
26.0 3.03
11761
28.0 3.41
12424
29.0 3.88
13000
31.0 4.33
13263
32.0 4.54
4939
13.3 1.01
5514
14.1 1.13
6397
15.4 1.35
6985
16.6 1.53
7397
17.5 1.67
7930
18.7 1.86
8314
19.4 2.01
8817
20.0 2.23
9199
21.0 2.40
9578
22.0 2.59
9953
23.0 2.78
10211
24.0 2.93
10582
25.0 3.15
11196
27.0 3.55
11889
28.0 4.04
12491
30.0 4.52
12764
31.0 4.75
5581
15.3 1.52
6193
16.2 1.68
6835
17.4 1.89
7311
18.1 2.06
7911
19.0 2.29
8347
19.9 2.48
8777
21.0 2.68
9202
22.0 2.89
9487
23.0 3.04
9895
24.0 3.26
10566
26.0 3.66
11322
27.0 4.16
11963
29.0 4.64
12245
30.0 4.87
5817
16.8 1.99
6748
17.7 2.29
7299
18.6 2.50
7806
19.4 2.71
8305
21.0 2.93
8630
21.0 3.09
9090
23.0 3.33
9844
25.0 3.76
10674
26.0 4.29
11351
28.0 4.77
11658
29.0 5.00
6405
18.2 2.63
7144
19.3 2.91
7591
20.0 3.09
8132
21.0 3.35
9011
23.0 3.81
9918
25.0 4.35
10673
27.0 4.87
11015
28.0 5.11
7982
22.0 3.79
9049
23.0 4.38
9923
25.0 4.92
10285
27.0 5.17
7955
22.0 4.32
9018
24.0 4.92
9427
25.0 5.18
7663
23.0 4.74
8352
24.0 5.11
Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive
losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard
301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream.
26
www.PennBarry.com | Moving Your Way
©PENNBARRY 2014
347
1/3
Fumex | FX
66"
2.500
761 RPM
2.250
2.000
Do not select in shaded area.
664 RPM
1.750
5 ½"
RPM
BHP
47 ½"
1.500
1.250
560 RPM
1.000
488 RPM
443 RPM
0.750
4000
1
2
1/
HP
1H 2H
P P
8000
12000
3
HP
44 ½" x 44 ½"
16000
AIRFLOW - CFM
HP
0
3/4
HP HP
2
1/
0.000
1/2
HP
0.250
7
386 RPM
355 RPM
309 RPM
0.500
5
STATIC PRESSURE - Inches W.G.
FX36B | BELT DRIVE
20000
24000
Galv. Steel Base = 12 Gage
Roof Opening = 36” SQ.
Peak BHP = (RPM/384)3
Aluminum Base = 0.102
Damper Size = 35 ½” SQ.
Max. RPM = 810 (7 ½ HP)
Discharge Apron = 0.080
Max. Motor Frame Size = 213T Est. Ship Weight = 470 lbs.*
* Add 110 lbs. for Heat & Smoke option.
Tip
0.000” SP
HP RPM Speed
FPM Sones BHP
269
2619
309
3008
335
3261
355
3456
370
3602
386
3758
405
3943
1 1/2 420
4089
443
4313
465
4527
488
4751
500
4868
515
5014
530
5160
550
5355
560
5452
580
5647
600
5841
620
6036
640
6231
664
6464
680
6620
700
6815
7 1/2 720
7010
745
7253
761
7409
1/2
3/4
1
2
3
©PENNBARRY 2014
5
7603
5.6 0.25
8734
7.2 0.37
9469
8.4 0.48
10034
9.4 0.57
10458
10.1 0.64
10911
10.9 0.73
11448
11.8 0.84
11872
12.6 0.94
12522
14.0 1.10
13144
15.0 1.27
13794
16.3 1.47
14133
17.3 1.58
14557
18.3 1.73
14981
18.8 1.88
15547
19.4 2.11
15829
19.8 2.22
16395
21.0 2.47
16960
22.0 2.73
17525
24.0 3.02
18091
25.0 3.32
18769
26.0 3.71
19221
27.0 3.98
19787
28.0 4.34
20352
29.0 4.72
21059
31.0 5.23
21511
32.0 5.58
0.250” SP
Sones
BHP
4897
5.4 0.34
6761
6.8 0.51
7715
7.8 0.63
8409
8.7 0.74
8912
9.3 0.82
9441
10.0 0.92
10054
11.0 1.04
10531
11.8 1.15
11255
13.1 1.32
11941
14.2 1.51
12653
15.5 1.72
13022
16.5 1.84
13483
17.5 2.00
13942
18.1 2.17
14552
18.7 2.42
14855
19.1 2.54
15460
20.0 2.82
16063
22.0 3.10
16663
24.0 3.41
17262
25.0 3.74
17978
26.0 4.17
18453
26.0 4.47
19047
27.0 4.86
19639
29.0 5.28
20372
31.0 5.81
20839
32.0 6.17
0.500” SP
Sones
BHP
6306
8.2 0.88
7253
8.8 1.01
8198
9.7 1.17
8875
10.5 1.30
9785
11.8 1.51
10593
12.8 1.71
11417
14.2 1.94
11823
15.1 2.07
12327
16.1 2.23
12827
16.6 2.41
13488
17.2 2.65
13810
17.6 2.78
14449
18.7 3.05
15084
20.0 3.34
15713
22.0 3.64
16339
24.0 3.96
17086
24.0 4.38
17581
25.0 4.67
18197
26.0 5.05
18813
27.0 5.48
19579
29.0 6.04
20067
31.0 6.42
0.750” SP
Sones
BHP
8429
11.7 1.76
9673
13.4 2.05
10221
14.3 2.20
10896
15.3 2.40
11516
15.7 2.60
12259
16.1 2.87
12627
16.5 3.00
13354
17.6 3.29
14062
19.0 3.60
14738
21.0 3.92
15407
22.0 4.26
16203
23.0 4.69
16726
23.0 5.00
17367
24.0 5.39
18003
25.0 5.81
18794
27.0 6.36
19297
29.0 6.73
1.000” SP
Sones
BHP
8139
14.3 2.29
9322
14.7 2.59
10497
15.2 2.94
11008
15.6 3.10
11922
16.7 3.44
12820
18.3 3.80
13596
20.0 4.14
14337
21.0 4.50
15213
22.0 4.96
15791
22.0 5.28
16481
23.0 5.69
17155
24.0 6.13
17990
26.0 6.70
18520
28.0 7.08
1.250” SP
Sones
BHP
9624
15.7 3.35
10863
17.3 3.77
12025
19.4 4.22
12945
21.0 4.63
14029
21.0 5.15
14708
22.0 5.51
15455
22.0 5.94
16193
23.0 6.39
17104
25.0 6.99
17681
27.0 7.40
1.375” SP
Sones
BHP
10842
18.7 4.14
12022
20.0 4.61
13246
21.0 5.17
13975
21.0 5.54
14874
22.0 6.03
15681
23.0 6.52
16610
25.0 7.12
17198
26.0 7.53
1.500” SP
Sones
BHP
10872
19.7 4.53
12296
20.0 5.14
13211
21.0 5.56
14131
21.0 6.05
15037
23.0 6.57
16116
24.0 7.25
16714
26.0 7.66
1.750” SP
Sones
BHP
12265
20.0 5.96
13445
22.0 6.56
14756
24.0 7.31
15488
25.0 7.77
2.000” SP
Sones
BHP
12913
22.0 7.17
13862
24.0 7.71
Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive
losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard
301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream.
www.PennBarry.com | Moving Your Way
27
Fumex | FX
2.000
1.800
1.600
1.200
7.5
10
7
5H
RPM
P
0
5000
1/
2
48"
P
1 1/2
RPM
H
0.200
0.000
M
RPM
250 R
PM
200 RP
M
0.400
4"
Do not select in shaded area.
300
0.600
1
5
350
0.800
78"
RPM
BHP
RPM
RP
400
1.000
3/4
3
450
1.400
HP
2
496
10
STATIC PRESSURE - Inches W.G.
FMX50B | BELT DRIVE
HP
3H
P
59" x 59"
2H
P
1H
P
10000
15000
20000
AIRFLOW - CFM
25000
Galv. Steel Base = 12 Gage Roof/Wall Opening = 50” SQ.
Peak BHP = (RPM/218)3
Aluminum Base = 0.125
Damper Size = 49 ½” SQ.
Max. RPM = 496 (10 HP)
Discharge Apron = 0.125
Max. Motor Frame Size = 215T Est. Ship Weight = 928 lbs.
Tip
0.000
0.125
0.250
0.375
0.500
0.625
0.750
1.000
1.250
1.500
Speed
FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
190
2487
210
2749
220
2880
230
3011
240
3142
255
3338
265
3469
280
3665
290
3796
300
3927
320
4189
330
4320
350
4581
370
4843
390
5105
400
5236
410
5367
420
5498
430
5629
440
5760
450
5890
460
6021
470
6152
480
6283
490
6414
496
6493
9590
6.8 0.58
10599
7.7 0.78
11104
8.2 0.90
11609
8.6 1.03
12114
9.0 1.17
12871
9.4 1.40
13376
9.6 1.57
14133
9.8 1.86
14637
9.8 2.06
15142
10.3 2.28
16152
11.2 2.77
16656
11.7 3.04
17666
12.6 3.62
18675
13.5 4.28
19685
14.2 5.02
20189
14.6 5.41
20694
14.9 5.83
21199
15.2 6.27
21704
15.5 6.72
22208
15.7 7.20
22713
16.0 7.70
23218
16.2 8.23
23723
16.3 8.78
24227
16.4 9.35
24732
17.0 9.95
25035
17.3 10.3
6496
6.5 0.50
7916
7.5 0.71
8594
8.0 0.82
9235
8.4 0.95
9844
8.9 1.09
10742
9.6 1.32
11332
10.0 1.48
12203
10.7 1.76
12775
11.1 1.96
13343
11.6 2.18
14466
12.8 2.66
15023
13.4 2.92
16127
14.6 3.50
17221
15.7 4.15
18307
16.9 4.88
18846
16.2 5.27
19383
16.9 5.68
19919
17.5 6.11
20454
18.2 6.57
20987
18.9 7.05
21519
19.5 7.54
22049
20.2 8.07
22579
20.8 8.61
23108
21.5 9.18
23635
22.2 9.77
23951
22.6 10.14
-
-
3932
7.4 0.53
5052
7.8 0.65
6059
8.2 0.79
6952
8.6 0.94
8155
9.1 1.17
8913
9.5 1.35
10011
10.1 1.64
10713
10.5 1.84
11401
11.1 2.07
12737
12.3 2.56
13350
12.9 2.82
14558
14.2 3.39
15745
15.3 4.03
16914
16.4 4.75
17489
17.0 5.14
18060
17.6 5.55
18628
18.1 5.97
19193
18.7 6.43
19756
19.2 6.90
20316
19.7 7.39
20874
20.2 7.91
21429
20.6 8.45
21982
21.1 9.02
22534
21.8 9.60
22864
22.2 9.97
2496
8.6 0.62
4559
9.1 0.92
5705
9.4 1.11
7267
9.7 1.41
8170
9.8 1.63
9007
10.3 1.86
10577
11.5 2.35
11319
12.1 2.63
12761
13.5 3.22
14139
14.8 3.88
15481
15.9 4.62
16096
16.4 5.01
16705
17.0 5.41
17310
17.6 5.84
17910
18.2 6.29
18506
18.7 6.75
19098
19.2 7.25
19686
19.7 7.76
20271
20.1 8.30
20850
20.6 8.86
21425
21.3 9.44
21768
21.7 9.81
3318
9.7 1.03
4715
9.8 1.30
5907
10.3 1.56
8087
11.2 2.09
8998
11.7 2.37
10689
12.6 2.97
12250
13.8 3.64
13724
15.1 4.39
14446
15.7 4.79
15143
16.2 5.21
15832
16.9 5.65
16514
17.5 6.11
17189
18.0 6.59
17855
18.6 7.10
18471
19.1 7.61
19081
19.5 8.14
19688
20.0 8.70
20290
20.7 9.28
20650
21.1 9.65
4744
11.2 1.67
5981
11.7 2.01
8219
12.6 2.65
10154
13.5 3.34
11846
14.2 4.10
12643
14.6 4.50
13421
15.3 4.93
14167
15.8 5.37
14904
16.5 5.84
15632
16.6 6.33
16346
17.7 6.83
17041
18.3 7.36
17730
18.8 7.91
18412
19.2 8.49
19087
20.0 9.09
19490
20.5 9.47
5128
12.6 2.17
7529
13.5 2.96
9705
14.2 3.75
10643
14.6 4.17
11543
14.9 4.60
12393
15.2 5.05
13199
15.5 5.52
13994
15.9 6.01
14767
16.5 6.53
15513
17.1 7.06
16250
17.7 7.61
16980
18.2 8.20
17699
19.1 8.80
18119
19.6 9.17
3798
14.2 2.58
5311
14.6 3.12
6654
14.9 3.67
7864
15.2 4.20
9007
15.5 4.70
10104
15.7 5.22
11171
16.0 5.76
12119
16.2 6.31
13022
16.3 6.88
13904
16.4 7.48
14717
17.0 8.09
15199
17.3 8.46
4825
15.7 3.88
6364
16.0 4.56
7638
16.2 5.23
8842
16.3 5.90
9985
16.4 6.53
11088
17.0 7.17
11733
17.3 7.57
4992
16.4 4.93
6520
17.0 5.74
7381
17.3 6.24
Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive
losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard
301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream.
28
www.PennBarry.com | Moving Your Way
©PENNBARRY 2014
RPM
Fumex | FX
ENGINEERING SPECIFICATIONS
Model
FX =Centrifugal Fan
WFX = Wall Mounted Centrifugal Fan
FMX =High Capacity Centrifugal Fan
Unit Size
08, 10 , 11, 12, 13, 14, 16,
18, 24, 27, 30, 36, 50
Drive Type
D= Direct Drive
B = Belt Drive
Q = 1725 RPM
R = 1550 RPM
S = 1300 RPM
V = 1050 RPM
Q1 = 1650 RPM
Q2 = 1725 RPM
Motor Speed
1= Single Speed
2= 2S2W Single & Three Phase
3= 2S1W Three Phase
1/50 1/121/5 3/4
1/30 1/111/4 1
1/25
1/7
1/3
1 1/2
1/201/6 1/2 2
3
5
7 1/2
10
G= 230V
H= 240V
J = 277V
K= 380V
L = 400V
M= 415V
Phase
1 = Single
3 = Three
Cycle
5= 50 Hz
6= 60 Hz
Efficiency
©PENNBARRY 2014
S= Standard
H= High Efficiency
0 = None
S = Single
D= Double
Metal Liner
0 = None
L = Metal Liner
Damper Holding Plate
0 = None
P= Damper Holding Plate
0 = None
G= Gasket
No Wooden Nailer
0 = None
N= No Wooden Nailer
Curb Paint/Coating
B= Air Dried Epoxy
Q= Enamel
Hinged Sub-base
0 = None
H= Hinged Sub-base
Mounting Pedestal
0 = None
P= Mounting Pedestal
Floating Hinge Kit
0 = None
H= Floating Hinge Kit
Damper
N= 440V
P= 460V
Q= 480V
R= 575V
S= 600V
X= Special
Slope
Neoprene Gasket
0 = None
C = Standard
B = Optional
O = Open Drip Proof
T = Totally Enclosed
E = Explosion Proof
X = Special
A = 110V
B= 115V C= 120V
D= 200V
E= 208V
F = 220V
0 = None
50= Chrome Green
53= Williamsburg Blue
55= Pale Green
56= Dove Gray
61= White
63= Oxford Beige
65= Dover White
66= Desert Tan
70= Black
73= Smoke Gray
77= Brick Red
79= Peppercorn
81= Pale Brown
83= Chocolate Brown
85= Timeless Bronze
94= Charcoal
X = Special
AMCA Spark Rating
Enclosure
Voltage
0 = None
F = Epoxy Powder Coat*
G= Epoxy Powder Coat with UV*
H= Hi-Temp Powder Coat*
J = Non-stick Powder Coat*
K= Phenolic Powder Coat*
L = Phenolic Powder Coat with UV*
N= Polyester Powder Coat
X= Special
* Not available with choice of color.
Color
Motor Tap
Horse Power
Paint / Coating
Aluminum Base
0 = None
BDD = Gravity Back Draft Damper
MD1 = Gravity Back Draft Damper 115V
MD2 = Gravity Back Draft Damper 230V
MD4 = Gravity Back Draft Damper 460V
ED1 = Explosion Proof Motor
Operated Damper 115V
0 = None
P= Thermal Overload Protection
Screen
Disconnect Switch
0= None
B= Bird Screen
S= Insect/Bird Screen
Roof Curb
0 = None
A = UCG8 B= UCG12
C= UCG18
D= UCA8
E= UCA12
F = SFA12
G= SFA18
H= SCG16
J = SCA16
K= UCA18
L = UG12
M= SA16
N= SFG12
P= SFG18
Q= SG16
R= SRA16
S= SRG16
T = UA12
U= UA18
V = UG18
W= URA12
Y = URA18
1 = URG12
10= SFA8
11= USCG
12= USCA
2 = URG18
4 = UVA18
5 = UVG18
0 = None
A = Aluminum Base
Thermal Overload Protection
0 = None
1 = NEMA 1 Disconnect Switch
3R= NEMA 3R Disconnect Switch
4 = NEMA 4 Disconnect Switch
7 = NEMA 7 Disconnect Switch
9 = NEMA 9 Disconnect Switch
Internal Wiring
0 = None
1 = NEMA 1 Internal Wiring
3R= NEMA 3R Internal Wiring
Continued, next page.
www.PennBarry.com | Moving Your Way
29
Fumex | FX
ENGINEERING SPECIFICATIONS
Transformer
0 = None
T = Transformer
Speed Controller
0 = None
L = Loose
M = Mounted
Firestat Switch
0 = None
F = Firestat Switch
Fatrap
0 = None
F = Fatrap
Heat & Smoke Removal
0 = None
-HS = Heat & Smoke Removal
Wall Mount
0 = None
W= Wall Mount
High Pressure Wheel
0 = None
H = High Pressure Wheel
High Wind Construction
0 = None
M = Miami Dade Approved
Fumex - Direct Drive Units
Direct drive centrifugal roof exhaust upblast fan shall be Fumex FX, manufactured by
PennBarry, Plano, TX 75074. The housing shall be weatherproof, utilize heavy gauge
spun aluminum construction with a large rolled bead for strength, with galvanized
(aluminum optional) base, with rigid galvanized steel internal support structures. Housing
shall not provide any of the internal structural support. Units shall be equipped with an
oversized electrical conduit chase through the curb cap and into the motor compartment
for ease of wiring (except Explosion Proof). Units shall be pre-wired to a junction box
mounted in the motor compartment and equipped with an electrical disconnect device
(except Explosion Proof).
Statically and dynamically balanced backward inclined, centrifugal wheels shall be
aluminum, spark-resistant, nonoverloading, and matched to deeply spun venturis.
Motors shall be continuous duty, permanently lubricated, multispeed (for applicable
models), have thermal overload protection, mounted out of the main airstream, be easily
accessible for service, and furnished at the specified voltage, phase and enclosure.
Each fan shall bear the AMCA Certified Ratings Seal for Air and Sound Performance,
and shall be UL (UL Std. 705, UL Std. 762 optional applicable models) and CSA listed.
If specified (Fatrap option), fan shall additionally provide UL 762 Listing rated at 400ºF,
motor pre-wired to a weather-proof junction box, and drain connection leading into a
grease collector/separator box.
Fumex - Belt Drive Units
Belt drive centrifugal roof exhaust upblast fan shall be Fumex FX/FMX, manufactured
by PennBarry, Plano, TX 75074. The housing shall be weatherproof, utilize heavygauge spun aluminum construction with a large rolled bead for strength, with galvanized
(aluminum optional except FMX) base, with rigid galvanized steel internal support
structures. Housing shall not provide any of the internal structural support. Large
diameter cooling tube shall provide ambient air to flow over motor. Units shall be
equipped with an oversized electrical conduit chase through the curb cap and into the
motor compartment for ease of wiring (except Explosion Proof). Units shall be prewired
to a junction box mounted in the motor compartment and equipped with an electrical
disconnect device (except Explosion Proof).
Statically and dynamically balanced backward inclined, centrifugal wheels shall be
aluminum, spark-resistant, nonoverloading, and be matched to deeply spun venturis.
Motors shall be continuous duty, ball bearing design, permanently lubricated, mounted
out of the main airstream, and furnished at the specified voltage, phase, and enclosure.
Shafts shall be turned, ground and polished. Heavy duty ball bearings are rated for
a minimum L50 life exceeding 200,000 hours. Pulleys shall be adjustable, cast iron,
machined, keyed, securely attached, and sized for 150% of the horsepower at its rated
maximum speed. Each fan shall bear the AMCA Certified Ratings Seal for Air and
Sound Performance (FX) or for Air performance (FMX), and shall be UL (UL Std. 705,
UL Std. 762 optional) and CSA listed. If specified (Fatrap option), fan shall additionally
provide UL 762 Listing rated at 400ºF. (300ºF FMX), motor pre-wired to a weatherproof junction box, and drain connection leading into a grease collector/separator box.
If specified (heat and smoke removal option), fan shall additionally provide UL listing
rated for 500°F at 4-hours and 1000°F at 1 hour, including steel wheel and additional
cooling tube.
©PENNBARRY 2014
30
www.PennBarry.com | Moving Your Way
Connect with PennBarry
PennBarry Product Solutions
COMMERCIAL
INDUSTRIAL
ENERGY RECOVERY
Roof & Wall Exhaust Centrifugal Fans
Utility Vent Sets
Outdoor Units
Ceiling, Wall, & Inline Centrifugal Fans
Freestanding Centrifugal Fans
Indoor Units
Roof Supply Centrifugal Fans
Industrial & Material Handling Fans
Square & Round Centrifugal Fans
Tubular Centrifugal Inline Fans
Wall Mounted Axial Fans
Mixed Flow Centrifugal Fans
Hooded Roof Axial Fans
Plug & Plenum Fans
Upblast Roof Axial Fans
Wall Mounted Propeller Fans
Gravity Ventilators
Tube Axial Fans
Roof Curbs
Vane Axial Fans
KITCHEN VENTILATION
Kitchen Hoods
Make-Up Air Units
Exhaust Fans
Bifurcator Fans
Fume Exhaust
Moving Your Way
PennBarry is proud to be your preferred manufacturer of commercial and industrial fans and blowers. Learn how PennBarry can
assist you in your next application by contacting your PennBarry Representative or visiting us on the web at www.pennbarry.com.
PennBarry | www.pennbarry.com | pennbarrysales@pennbarry.com | tel: 972.212.4700 | fax: 972.212.4702
PennBarry reserves the right to make changes at any time, without notice, to models, construction, specifications, options, availability, etc.
This bulletin illustrates the appearance of PennBarry products at the time of publication. View the latest updates on the PennBarry website.
© Copyright 2014 PennBarry. All Rights Reserved. FUMEX FEBRUARY 2014