TECHNICAL MANUAL for CHILLED WATER DUCTED CWD HORIZONTAL FAN COILS from MARSTAIR LTD. This manual provides technical and installation information for CWD (401 series) CHILLED WATER HORIZONTAL fan coils. INDEX PAGE GENERAL Part numbers, unit features/accessories, weights Optional control valves, air volumes 2 2 SELECTION Performance data (CW and LPHW) Coil water volumes External resistance v. air volume and duty tables Optional electric heating, sound pressure/power 3 - 10 11 11 12 ELECTRICAL Electrical data, recommended fuses 12 - 13 UNIT INSTALLATION CWD Pipework and electrical connections Ductwork, maintenance, hydraulic resistances 13 - 14 15 15 - 16 WIRING DIAGRAMS CWD 17 - 18 OPERATION CWD 19 COMPONENT IDENTIFICATION Exploded view of CWD with component Identification 20 Marstair Ltd., Armytage Road, Brighouse, West Yorkshire. HD6 1QF, UK. Tel: +44 (0) 1484 405600 Fax: +44 (0) 1484 405620 Email: sales@marstair.com 40100616-05 -1- MARSTAIR LIMITED - CWD CHILLED WATER DUCTED HORIZONTAL FAN COILS The CWD range consists of the 401 series of chilled water ducted horizontal fan coils. CHILLED WATER CWD INDOOR UNITS Models Part Number CWD 25 CWD 45 CWD 65 CWD 95 CWD 105 CWD 115 CWD 165 CWD 175 40100001 40100002 40100003 40100004 40100005 40100006 40100027 40100028 Refer to pages 13 and 14 for CWD dimensions and operating weights FEATURES/ACCESSORIES WEIGHTS CWD UNIT PACKED WEIGHT (kg) UNPACKED WEIGHT (kg) 21 Integral Discharge Plenum STD 25 Long life washable filter (to G2) STD 45 * 65 */STD 95 Fresh Air Connection (despatched loose) * 105 3 Speed Switch * 115 Return Air Plenum * 165 80 All Spigots * 175 80 Control and Valve Options * Condensate pump Electric or LPHW heating Key: ** = factory fitted option only These units are p a c k e d according to the size of order. For single units, add approximately 1kg to the unpacked weight. 31 41 42 54 55 STD = standard. OPTIONAL CONTROL VALVES A choice of 2 or 4 port valves is available: these are factory fitted and sited above the condensate tray to give the following water flow arrangements. AIR VOLUME (m3/s) based on 30 Pa external resistance SPIGOTS CWD Minimum Speed Med/Min Medium Speed Med/Max 230V 230V 230V 230V Maximum Speed 230V 25 B 0.048 0.067 0.090 0.107 0.119 45 B&C 0.095 0.110 0.174 0.209 0.234 65 B&C 0.101 0.145 0.201 0.252 0.295 95 B, C & D 0.173 0.232 0.288 0.339 0.377 105 B, C & D 0.165 0.230 0.282 0.331 0.370 115 B, C & D 0.188 0.259 0.320 0.370 0.400 165 B, C & D 0.250 --- 0.430 --- 0.550 175 B, C & D 0.350 --- 0.510 --- 0.600 -2- PERFORMANCE DATA (AT 30Pa EXTERNAL RESISTANCE, 230V.) CWD 25 COOLING DUTIES Room Air On wb /C db /C 27 19 21 15 21 15 21 15 21 15 21 15 21 15 21 15 21 15 21 15 24 17 24 17 24 17 24 17 24 17 24 17 24 17 24 17 24 17 27 19 27 19 27 19 27 19 27 19 27 19 27 19 27 19 27 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 CW Temperature IN /C OUT /C 6 11 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 Minimum Speed 0.048 m3/s Total Sensible 1.31 0.91 0.88 0.68 0.71 0.60 0.60 0.56 0.63 0.57 0.52 0.52 0.46 0.46 0.48 0.48 0.42 0.42 0.36 0.36 1.20 0.85 0.95 0.74 0.83 0.68 0.96 0.74 0.75 0.65 0.64 0.60 0.70 0.63 0.57 0.57 0.51 0.51 1.53 1.01 1.30 0.91 1.09 0.81 1.30 0.90 1.03 0.79 0.89 0.73 1.05 0.80 0.81 0.70 0.69 0.65 1.54 1.12 1.32 1.02 1.11 0.93 1.31 1.02 1.06 0.91 0.91 0.85 1.07 0.91 0.82 0.81 0.76 0.76 Medium Speed 0.090 m3/s Total Sensible 2.07 1.50 1.40 1.13 0.95 0.93 0.84 0.84 1.01 0.96 0.78 0.78 0.68 0.68 0.77 0.77 0.63 0.63 0.52 0.52 1.91 1.40 1.51 1.23 1.10 1.05 1.52 1.23 1.04 1.03 0.91 0.91 1.11 1.06 0.86 0.86 0.76 0.76 2.43 1.66 2.08 1.50 1.61 1.30 2.05 1.49 1.67 1.33 1.16 1.13 1.65 1.32 1.23 1.16 0.99 0.99 2.45 1.85 2.10 1.70 1.65 1.51 2.07 1.69 1.70 1.53 1.31 1.31 1.67 1.52 1.36 1.36 1.14 1.14 Maximum Speed 0.119 m3/s Total Sensible 2.48 1.84 1.68 1.40 1.15 1.15 0.97 0.97 1.20 1.19 0.92 0.92 0.79 0.79 0.96 0.96 0.73 0.73 0.61 0.61 2.28 1.72 1.82 1.52 1.25 1.25 1.82 1.52 1.30 1.30 1.07 1.07 1.32 1.32 1.06 1.06 0.88 0.88 2.92 2.03 2.48 1.85 1.95 1.63 2.45 1.83 1.99 1.65 1.39 1.39 1.97 1.63 1.46 1.44 1.16 1.16 2.93 2.28 2.51 2.10 1.99 1.88 2.47 2.08 2.02 1.90 1.66 1.66 1.99 1.88 1.68 1.68 1.43 1.43 CWD 25 HEATING DUTIES Room Air On wb /C/%RH db /C 20 12 10 50% 10 50% 10 50% 10 50% 10 50% 10 50% 15 50% 15 50% 15 50% 15 50% 15 50% 15 50% 20 50% 20 50% 20 50% 20 50% 20 50% 20 50% 25 50% 25 50% 25 50% 25 50% 25 50% 25 50% LPHW Temperature IN /C OUT /C 80 70 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 Minimum Speed 0.048 m3/s Total 0.71 1.02 0.93 0.87 0.76 0.62 0.46 0.95 0.85 0.79 0.68 0.54 0.50 0.87 0.77 0.71 0.60 0.46 0.35 0.79 0.69 0.63 0.51 0.37 0.29 -3- Medium Speed 0.090 m3/s Total 1.01 1.44 1.32 1.22 1.08 0.88 0.70 1.33 1.21 1.11 0.97 0.77 0.57 1.23 1.10 1.01 0.86 0.66 0.44 1.12 0.99 0.90 0.75 0.55 0.37 Maximum Speed 0.119 m3/s Total 1.16 1.66 1.52 1.41 1.25 1.02 0.82 1.54 1.40 1.28 1.13 0.89 0.68 1.42 1.27 1.16 1.00 0.77 0.52 1.29 1.15 1.04 0.87 0.64 0.40 CWD 45 COOLING DUTIES Room Air On wb /C db /C 27 19 21 15 21 15 21 15 21 15 21 15 21 15 21 15 21 15 21 15 24 17 24 17 24 17 24 17 24 17 24 17 24 17 24 17 24 17 27 19 27 19 27 19 27 19 27 19 27 19 27 19 27 19 27 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 CW Temperature IN /C OUT /C 6 11 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 Minimum Speed 0.095 m3/s Total Sensible 2.59 1.79 1.75 1.35 1.26 1.13 1.04 1.03 1.26 1.13 0.96 0.96 0.85 0.85 0.89 0.89 0.78 0.78 0.66 0.66 2.37 1.67 1.87 1.44 1.47 1.27 1.91 1.46 1.34 1.22 1.13 1.13 1.41 1.25 1.05 1.05 0.94 0.94 3.01 1.98 2.60 1.80 1.93 1.51 2.56 1.78 2.11 1.58 1.56 1.36 2.08 1.57 1.50 1.34 1.22 1.22 3.03 2.20 2.64 2.02 1.97 1.73 2.58 2.00 2.15 1.81 1.60 1.59 2.11 1.79 1.58 1.58 1.40 1.40 Medium Speed 0.174 m3/s Total Sensible 4.01 2.88 2.72 2.19 1.82 1.79 1.48 1.48 1.98 1.86 1.39 1.39 1.20 1.20 1.50 1.50 1.11 1.11 0.92 0.92 3.67 2.69 2.98 2.39 1.90 1.90 2.95 2.37 2.16 2.04 1.62 1.62 2.18 2.05 1.66 1.66 1.34 1.34 4.66 3.17 4.04 2.90 3.24 2.56 3.94 2.86 3.28 2.58 2.27 2.18 3.19 2.54 2.45 2.25 1.76 1.76 4.69 3.55 4.08 3.28 3.31 2.95 3.97 3.23 3.33 2.96 2.60 2.60 3.22 2.91 2.63 2.63 2.23 2.23 Maximum Speed 0.234 m3/s Total Sensible 4.82 3.58 3.29 2.73 2.31 2.30 1.72 1.72 2.38 2.33 1.82 1.82 1.39 1.39 1.89 1.89 1.29 1.29 1.06 1.06 4.43 3.34 3.61 2.98 2.47 2.47 3.54 2.96 2.63 2.58 1.89 1.89 2.60 2.57 2.13 2.13 1.56 1.56 5.61 3.92 4.87 3.60 3.93 3.22 4.73 3.55 3.94 3.22 2.85 2.80 3.81 3.17 2.93 2.83 2.33 2.33 5.64 4.40 4.91 4.09 4.00 3.71 4.76 4.02 3.99 3.70 3.29 3.29 3.84 3.65 3.29 3.29 2.85 2.85 CWD 45 HEATING DUTIES Room Air On wb /C/%RH db /C 20 12 10 50% 10 50% 10 50% 10 50% 10 50% 10 50% 15 50% 15 50% 15 50% 15 50% 15 50% 15 50% 20 50% 20 50% 20 50% 20 50% 20 50% 20 50% 25 50% 25 50% 25 50% 25 50% 25 50% 25 50% LPHW Temperature IN /C OUT /C 80 70 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 Minimum Speed 0.095 m3/s Total 1.43 2.01 1.89 1.72 1.59 1.28 1.12 3.02 1.74 1.58 1.44 1.14 0.97 1.72 1.60 1.43 1.30 0.99 0.81 1.58 1.45 1.29 1.15 0.84 0.64 -4- Medium Speed 0.174 m3/s Total 1.99 2.79 2.61 2.39 2.20 1.78 1.57 2.59 2.41 2.19 2.00 1.58 1.36 2.39 2.21 1.99 1.80 1.38 1.15 2.19 2.01 1.79 1.60 1.18 0.94 Maximum Speed 0.234 m3/s Total 2.31 3.25 3.04 2.78 2.56 2.06 1.83 3.02 2.80 2.54 2.33 1.83 1.59 2.78 2.57 2.31 2.10 1.60 1.35 2.55 2.34 2.08 1.87 1.37 1.11 CWD 65 COOLING DUTIES Room Air On wb /C db /C 27 19 21 15 21 15 21 15 21 15 21 15 21 15 21 15 21 15 21 15 24 17 24 17 24 17 24 17 24 17 24 17 24 17 24 17 24 17 27 19 27 19 27 19 27 19 27 19 27 19 27 19 27 19 27 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 CW Temperature IN /C OUT /C 6 11 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 Minimum Speed 0.101 m3/s Total Sensible 3.06 2.06 2.06 1.55 1.56 1.32 1.32 1.21 1.46 1.27 1.15 1.14 1.01 1.01 1.04 1.04 0.92 0.92 0.79 0.79 2.78 1.92 2.09 1.60 1.84 1.49 2.26 1.68 1.67 1.42 1.41 1.32 1.68 1.43 1.24 1.24 1.11 1.11 3.52 2.28 3.08 2.07 2.40 1.77 3.01 2.04 2.51 1.82 1.96 1.59 2.46 1.80 1.78 1.52 1.52 1.42 3.54 2.52 3.12 2.32 2.44 2.02 3.03 2.28 2.56 2.07 2.01 1.84 2.49 2.04 1.82 1.77 1.65 1.65 Medium Speed 0.201 m3/s Total Sensible 5.27 3.66 3.60 2.78 2.55 2.30 1.90 1.90 2.67 2.35 1.78 1.78 1.55 1.55 1.91 1.91 1.43 1.43 1.19 1.19 4.80 3.40 4.01 3.05 2.50 2.41 3.90 2.99 2.99 2.61 2.08 2.08 2.93 2.58 2.08 2.08 1.72 1.72 6.05 4.01 5.35 3.69 4.43 3.29 5.16 3.61 4.40 3.28 3.25 2.82 4.21 3.20 3.36 2.86 2.25 2.25 6.09 4.47 5.41 4.15 4.52 3.76 5.20 4.06 4.47 3.74 3.41 3.30 4.26 3.65 3.45 3.32 2.82 2.82 Maximum Speed 0.295 m3/s Total Sensible 6.86 4.90 4.70 3.74 3.51 3.21 2.34 2.34 3.48 3.19 2.55 2.55 1.89 1.89 2.61 2.61 1.76 1.76 1.44 1.44 2.78 1.92 5.25 4.12 3.79 3.50 5.06 4.03 3.94 3.56 2.65 2.65 3.79 3.50 2.96 2.96 2.12 2.12 7.88 5.35 6.98 4.96 5.84 4.47 6.69 4.83 5.72 4.43 4.42 3.91 5.44 4.31 4.37 3.89 3.27 3.27 7.91 5.98 7.04 5.59 5.93 5.12 6.73 5.45 5.79 5.06 4.56 4.56 5.49 4.93 4.52 4.52 3.96 3.96 CWD 65 HEATING DUTIES Room Air On wb /C/%RH db /C 20 12 10 50% 10 50% 10 50% 10 50% 10 50% 10 50% 15 50% 15 50% 15 50% 15 50% 15 50% 15 50% 20 50% 20 50% 20 50% 20 50% 20 50% 20 50% 25 50% 25 50% 25 50% 25 50% 25 50% 25 50% LPHW Temperature IN /C OUT /C 80 70 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 Minimum Speed 0.101 m3/s Total 1.87 2.60 2.47 2.23 2.10 1.69 1.53 2.41 2.28 2.05 1.91 1.50 1.34 2.23 2.10 1.87 1.73 1.32 1.15 2.04 1.91 1.68 1.55 1.14 0.96 -5- Medium Speed 0.201 m3/s Total 2.76 3.84 3.63 3.30 3.09 2.48 2.27 3.57 3.36 3.03 2.82 2.21 2.00 3.29 3.09 2.75 2.55 1.94 1.72 3.02 2.82 2.48 2.28 1.68 1.44 Maximum Speed 0.295 m3/s Total 3.38 4.71 4.45 4.05 3.78 3.04 2.77 4.38 4.12 3.71 3.45 2.71 2.44 4.05 3.79 3.38 3.12 2.38 2.11 3.71 3.46 3.05 2.79 2.06 1.78 CWD 95 COOLING DUTIES Room Air On wb /C db /C 27 19 21 15 21 15 21 15 21 15 21 15 21 15 21 15 21 15 21 15 24 17 24 17 24 17 24 17 24 17 24 17 24 17 24 17 24 17 27 19 27 19 27 19 27 19 27 19 27 19 27 19 27 19 27 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 CW Temperature IN /C OUT /C 6 11 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 Minimum Speed 0.173 m3/s Total Sensible 5.00 3.40 3.39 2.56 2.25 2.04 1.87 1.87 2.49 2.15 1.74 1.74 1.53 1.53 1.65 1.65 1.40 1.40 1.18 1.18 4.54 3.16 3.72 2.78 2.62 2.31 3.69 2.77 2.40 2.21 2.04 2.04 2.77 2.37 1.91 1.91 1.69 1.69 5.73 3.74 5.05 3.42 3.91 2.92 4.90 3.35 4.15 3.02 2.79 2.47 4.01 2.96 3.11 2.60 2.20 2.20 5.77 4.15 5.11 3.84 4.07 3.37 4.94 3.76 4.22 3.44 2.88 2.88 4.06 3.37 3.21 3.02 2.54 2.54 Medium Speed 0.288 m3/s Total Sensible 7.34 5.13 5.01 3.89 3.63 3.27 2.52 2.52 3.72 3.31 2.38 2.38 2.04 2.04 2.69 2.69 1.89 1.89 1.56 1.56 6.68 4.77 5.60 4.28 3.24 3.24 5.42 4.20 4.18 3.67 2.76 2.76 4.08 3.63 2.98 2.98 2.28 2.28 8.42 5.62 7.46 5.18 6.20 4.63 7.17 5.05 6.14 4.61 4.61 3.99 5.86 4.49 4.69 4.02 2.99 2.99 8.47 6.25 7.53 5.82 6.32 5.29 7.23 5.69 6.22 5.25 4.79 4.67 5.92 5.13 4.80 4.67 4.01 4.01 Maximum Speed 0.377 m3/s Total Sensible 8.80 6.28 6.03 4.79 4.50 4.11 2.90 2.90 4.47 4.09 3.25 3.25 2.34 2.34 3.34 3.34 2.18 2.18 1.78 1.78 8.02 5.85 6.75 5.28 4.84 4.47 6.50 5.17 5.07 4.56 3.18 3.18 4.87 4.48 3.78 3.78 2.62 2.62 10.10 6.86 8.97 6.36 7.50 5.73 8.58 6.19 7.36 5.67 5.68 5.00 6.99 5.52 5.62 4.98 4.17 4.17 10.15 7.66 9.04 7.16 7.63 6.56 8.64 6.99 7.45 6.48 5.84 5.84 7.05 6.32 5.79 5.79 5.07 5.07 CWD 95 HEATING DUTIES Room Air On wb /C/%RH db /C 20 12 10 50% 10 50% 10 50% 10 50% 10 50% 10 50% 15 50% 15 50% 15 50% 15 50% 15 50% 15 50% 20 50% 20 50% 20 50% 20 50% 20 50% 20 50% 25 50% 25 50% 25 50% 25 50% 25 50% 25 50% LPHW Temperature IN /C OUT /C 80 70 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 Minimum Speed 0.173 m3/s Total 2.86 3.98 3.78 3.42 3.22 2.59 2.39 3.69 3.50 3.14 2.94 2.31 2.11 3.41 3.22 2.86 2.67 2.04 1.83 3.13 2.94 2.58 2.39 1.76 1.54 -6- Medium Speed 0.288 m3/s Total 3.80 5.28 5.01 4.54 4.27 3.43 3.15 4.91 4.64 4.17 3.90 3.06 2.79 4.53 4.27 3.80 3.53 2.70 2.42 4.16 3.90 3.43 3.16 2.33 2.06 Maximum Speed 0.377 m3/s Total 4.39 6.09 5.78 5.24 4.92 3.96 3.63 5.66 5.35 4.81 4.50 3.53 3.21 5.23 4.92 4.38 4.07 3.11 2.79 4.81 4.50 3.96 3.65 2.69 2.37 CWD 105 COOLING DUTIES Room Air On wb /C db /C 27 19 21 15 21 15 21 15 21 15 21 15 21 15 21 15 21 15 21 15 24 17 24 17 24 17 24 17 24 17 24 17 24 17 24 17 24 17 27 19 27 19 27 19 27 19 27 19 27 19 27 19 27 19 27 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 CW Temperature IN /C OUT /C 6 11 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 Minimum Speed 0.165 m3/s Total Sensible 5.32 3.55 3.62 2.68 2.62 2.21 2.22 2.03 2.70 2.24 1.94 1.91 1.70 1.70 1.76 1.76 1.55 1.55 1.32 1.32 4.80 3.29 4.01 2.92 3.08 2.50 3.94 2.88 2.80 2.38 2.38 2.21 3.00 2.47 2.09 2.09 1.88 1.88 6.02 3.88 5.41 3.59 4.00 2.97 5.18 3.48 4.48 3.17 3.29 2.67 4.27 3.08 3.41 2.72 2.56 2.39 6.05 4.29 5.47 4.01 4.31 3.49 5.21 3.89 4.56 3.59 3.38 3.09 4.32 3.49 3.53 3.15 2.78 2.78 Medium Speed 0.282 m3/s Total Sensible 8.21 5.59 5.63 4.24 4.24 3.61 2.90 2.90 4.25 3.61 2.72 2.72 2.36 2.36 2.93 2.93 2.18 2.18 1.81 1.81 7.42 5.19 6.37 4.70 3.90 3.63 6.08 4.57 4.87 4.04 3.17 3.17 4.65 3.94 3.24 3.24 2.63 2.63 9.31 6.10 8.39 5.67 7.14 5.12 7.98 5.49 6.97 5.05 5.47 4.42 6.57 4.87 5.44 4.41 3.43 3.43 9.36 6.77 8.47 6.35 7.29 5.82 8.04 6.15 7.08 5.73 5.69 5.14 6.64 5.54 5.57 5.09 4.38 4.38 Maximum Speed 0.370 m3/s Total Sensible 10.01 6.94 6.88 5.28 5.34 4.58 3.37 3.37 5.19 4.51 3.60 3.60 2.73 2.73 3.70 3.70 2.53 2.53 2.08 2.08 9.07 6.44 7.81 5.86 5.90 5.03 7.42 5.68 5.99 5.07 3.69 3.69 5.66 4.93 4.21 4.21 3.05 3.05 11.37 7.55 10.25 7.04 8.78 6.40 9.72 6.81 8.51 6.28 6.82 5.59 7.99 6.06 6.63 5.51 4.63 4.63 11.42 8.40 10.34 7.90 8.94 7.28 9.79 7.65 8.62 7.14 7.04 6.49 8.07 6.91 6.78 6.38 5.64 5.64 CWD 105 HEATING DUTIES Room Air On wb /C/%RH db /C 20 12 10 50% 10 50% 10 50% 10 50% 10 50% 10 50% 15 50% 15 50% 15 50% 15 50% 15 50% 15 50% 20 50% 20 50% 20 50% 20 50% 20 50% 20 50% 25 50% 25 50% 25 50% 25 50% 25 50% 25 50% LPHW Temperature IN /C OUT /C 80 70 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 Minimum Speed 0.165 m3/s Total 2.79 3.87 3.68 3.33 3.14 2.52 2.33 3.60 3.41 3.06 2.87 2.25 2.05 3.32 3.14 2.79 2.60 1.98 1.78 3.05 2.87 2.52 2.33 1.72 1.50 -7- Medium Speed 0.282 m3/s Total 3.76 5.22 4.96 4.49 4.22 3.39 3.12 4.85 4.59 4.12 3.86 3.03 2.76 4.48 4.22 3.76 3.49 2.67 2.39 4.12 3.86 3.39 3.13 2.31 2.03 Maximum Speed 0.370 m3/s Total 4.34 6.04 5.73 5.19 4.88 3.92 3.60 5.61 5.30 4.77 4.45 3.50 3.18 5.18 4.88 4.34 4.03 3.08 2.76 4.76 4.46 3.92 3.61 2.66 2.34 CWD 115 COOLING DUTIES Room Air On wb /C db /C 27 19 21 15 21 15 21 15 21 15 21 15 21 15 21 15 21 15 21 15 24 17 24 17 24 17 24 17 24 17 24 17 24 17 24 17 24 17 27 19 27 19 27 19 27 19 27 19 27 19 27 19 27 19 27 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 CW Temperature IN /C OUT /C 6 11 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 Minimum Speed 0.188 m3/s Total Sensible 5.94 3.98 4.05 3.00 2.80 2.43 2.36 2.23 3.04 2.53 2.10 2.10 1.85 1.85 1.95 1.95 1.69 1.69 1.43 1.43 5.36 3.69 4.54 3.30 3.28 2.75 4.40 3.24 3.25 2.73 2.53 2.43 3.36 2.78 2.29 2.29 2.05 2.05 6.73 4.35 6.05 4.03 4.94 3.53 5.78 3.90 5.03 3.57 3.50 2.93 4.77 3.46 3.88 3.08 2.71 2.63 6.76 4.81 6.12 4.50 5.10 4.04 5.82 4.36 5.11 4.04 3.61 3.41 4.82 3.91 3.99 3.56 3.04 3.04 Medium Speed 0.320 m3/s Total Sensible 9.02 6.19 6.19 4.71 4.75 4.04 3.12 3.12 4.67 4.01 2.93 2.93 2.53 2.53 3.27 3.27 2.34 2.34 1.93 1.93 8.17 5.74 7.62 5.21 5.09 4.37 6.68 5.06 5.38 4.49 3.41 3.41 5.10 4.38 3.69 3.69 2.82 2.82 10.24 6.75 9.22 6.28 7.88 5.69 8.76 6.07 7.67 5.59 6.09 4.94 7.21 5.40 5.98 4.90 3.91 3.91 10.29 7.50 9.31 7.04 8.04 6.47 8.83 6.82 7.78 6.35 6.31 5.74 7.29 6.15 6.12 5.66 4.95 4.95 Maximum Speed 0.400 m3/s Total Sensible 10.57 7.36 7.27 5.62 5.67 4.89 3.52 3.52 5.48 4.80 3.89 3.89 2.84 2.84 3.94 3.94 2.64 2.64 2.16 2.16 9.58 6.84 8.25 6.23 6.30 5.38 7.83 6.04 6.33 5.40 4.06 4.06 5.97 5.24 4.50 4.50 3.18 3.18 12.00 8.01 10.82 7.48 9.28 6.80 10.25 7.22 8.98 6.68 7.22 5.96 8.42 6.45 7.00 5.87 4.99 4.99 12.06 8.92 10.92 8.40 9.45 7.75 10.33 8.13 9.10 7.60 7.45 6.91 8.41 7.35 7.15 6.80 6.02 6.02 CWD 115 HEATING DUTIES Room Air On wb /C/%RH db /C 20 12 10 50% 10 50% 10 50% 10 50% 10 50% 10 50% 15 50% 15 50% 15 50% 15 50% 15 50% 15 50% 20 50% 20 50% 20 50% 20 50% 20 50% 20 50% 25 50% 25 50% 25 50% 25 50% 25 50% 25 50% LPHW Temperature IN /C OUT /C 80 70 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 Minimum Speed 0.188 m3/s Total 3.00 4.17 3.97 3.59 3.38 2.72 2.50 3.88 3.67 3.30 3.09 2.42 2.21 3.58 3.38 3.00 2.80 2.13 1.92 3.29 3.09 2.71 2.51 1.85 1.62 -8- Medium Speed 0.320 m3/s Total 4.02 5.59 5.30 4.81 4.52 3.63 3.33 5.19 4.91 4.41 4.13 3.24 2.95 4.80 4.52 4.02 3.74 2.85 2.56 4.41 4.13 3.63 3.35 2.47 2.17 Maximum Speed 0.400 m3/s Total 4.53 6.29 5.96 5.41 5.08 4.08 3.74 5.84 5.52 4.96 4.64 3.64 3.31 5.40 5.08 4.52 4.20 3.21 2.87 4.96 4.64 4.09 3.76 2.77 2.44 CWD 165 COOLING DUTIES Room Air On wb /C db /C 27 19 21 15 21 15 21 15 21 15 21 15 21 15 21 15 21 15 21 15 24 17 24 17 24 17 24 17 24 17 24 17 24 17 24 17 24 17 27 19 27 19 27 19 27 19 27 19 27 19 27 19 27 19 27 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 CW Temperature IN /C OUT /C 6 11 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 Minimum Speed 0.250 m3/s Total Sensible 8.65 5.68 5.96 4.31 4.62 3.67 3.66 3.24 4.62 3.67 3.21 3.04 2.74 2.74 3.04 2.97 2.49 2.49 2.14 2.14 7.7 5.24 6.91 4.84 5.03 3.98 6.44 4.62 5.43 4.16 3.94 3.52 5.05 3.99 3.45 3.32 3.03 3.03 9.62 6.15 8.92 5.81 7.86 5.31 8.33 5.53 7.56 5.18 6.17 4.57 6.96 4.91 6.07 4.53 4.24 3.79 9.66 6.78 9.01 6.46 8.03 6.00 8.38 6.16 7.66 5.83 6.46 5.29 7.02 5.54 6.21 5.18 4.45 4.45 Medium Speed 0.430 m3/s Total Sensible 13.41 9.00 9.27 6.86 7.70 6.12 4.67 4.67 7.17 5.87 5.03 4.93 3.80 3.80 4.87 4.86 3.50 3.50 2.91 2.91 12.04 8.32 10.76 7.70 8.86 6.85 9.98 7.35 8.53 6.70 5.09 5.09 7.79 6.38 6.02 5.64 4.23 4.23 14.96 9.73 13.83 9.20 12.32 8.50 12.90 8.77 11.68 8.22 9.96 7.48 10.74 7.81 9.37 7.24 7.23 6.38 15.04 10.78 13.97 10.26 12.55 9.61 12.99 9.81 11.84 9.29 10.26 8.60 10.85 8.85 9.57 8.31 7.67 7.53 Maximum Speed 0.550 m3/s Total Sensible 16.05 10.94 11.12 8.36 9.27 7.50 5.35 5.35 8.58 7.18 6.28 6.18 4.33 4.33 5.98 5.98 4.65 4.65 3.29 3.29 14.45 10.12 12.89 9.39 10.71 8.41 11.94 8.96 10.20 8.19 7.39 7.02 9.29 7.80 7.23 6.95 5.08 5.08 17.96 11.82 16.57 11.17 14.75 10.36 15.44 10.67 13.95 10.01 11.92 9.15 12.81 9.52 11.16 8.84 8.74 7.89 18.06 13.13 16.73 12.51 15.02 11.73 15.56 11.97 14.14 11.34 12.25 10.53 12.95 10.82 11.40 10.18 9.29 9.29 CWD 165 HEATING DUTIES Room Air On wb /C/%RH db /C 20 12 10 50% 10 50% 10 50% 10 50% 10 50% 10 50% 15 50% 15 50% 15 50% 15 50% 15 50% 15 50% 20 50% 20 50% 20 50% 20 50% 20 50% 20 50% 25 50% 25 50% 25 50% 25 50% 25 50% 25 50% LPHW Temperature IN /C OUT /C 80 70 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 Minimum Speed 0.250 m3/s Total 4.67 6.46 6.17 5.57 5.28 4.24 3.94 6.00 5.72 5.12 4.83 3.79 3.49 5.55 5.27 4.67 4.38 3.34 3.04 5.09 4.81 4.22 3.93 2.90 2.60 -9- Medium Speed 0.430 m3/s Total 6.31 8.74 8.34 7.53 7.13 5.72 5.30 8.12 7.73 6.92 6.52 5.11 4.70 7.51 7.12 6.31 5.91 4.51 4.09 6.90 6.51 5.71 5.30 3.91 3.49 Maximum Speed 0.550 m3/s Total 7.20 9.96 9.50 8.58 8.11 6.51 6.03 9.26 8.80 7.89 7.42 5.82 5.34 8.56 8.11 7.19 6.73 5.14 4.65 7.87 7.41 6.50 6.04 4.45 3.97 CWD 175 COOLING DUTIES Room Air On wb /C db /C 27 19 21 15 21 15 21 15 21 15 21 15 21 15 21 15 21 15 21 15 24 17 24 17 24 17 24 17 24 17 24 17 24 17 24 17 24 17 27 19 27 19 27 19 27 19 27 19 27 19 27 19 27 19 27 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 29 19 CW Temperature IN /C OUT /C 6 11 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 5 9 5 11 5 13 7 11 7 13 7 15 9 13 9 15 9 17 Minimum Speed 0.350 m3/s Total Sensible 11.42 7.59 7.89 5.78 6.51 5.12 4.23 4.10 6.11 4.93 3.84 3.84 3.38 3.38 4.14 4.06 3.10 3.10 2.60 2.60 10.25 7.01 9.16 6.49 7.40 5.69 8.51 6.19 7.26 5.63 4.54 4.48 6.65 5.36 5.04 4.68 3.75 3.75 12.73 8.22 11.79 7.76 10.48 7.16 11.00 7.39 9.97 6.93 8.46 6.27 9.17 6.58 8.01 6.09 5.89 5.24 12.80 9.08 11.90 8.65 10.69 8.08 11.07 8.26 10.11 7.81 8.73 7.21 9.26 7.44 8.19 6.98 6.41 6.25 Medium Speed 0.510 m3/s Total Sensible 15.21 10.31 10.53 7.88 8.77 7.05 5.14 5.14 8.13 6.76 5.91 5.78 4.17 4.17 5.62 5.62 4.26 4.26 3.17 3.17 13.68 9.53 12.21 8.84 10.13 7.91 11.32 8.44 9.67 7.71 6.88 6.54 8.81 7.34 6.85 6.53 4.65 4.65 17.00 11.15 15.70 10.54 13.98 9.76 14.63 10.05 13.23 9.43 11.30 8.61 12.15 8.97 10.59 8.32 8.27 7.40 17.10 12.37 15.85 11.78 14.23 11.04 14.74 11.27 13.41 10.68 11.62 9.91 12.28 10.18 10.82 9.57 8.72 8.72 Maximum Speed 0.600 m3/s Total Sensible 17.04 11.69 11.83 8.95 9.86 8.04 6.33 6.33 9.11 7.70 6.71 6.65 4.53 4.53 6.41 6.41 5.07 5.07 3.43 3.43 15.36 10.82 13.70 10.05 11.40 9.03 12.68 9.59 10.83 8.78 7.95 7.58 9.86 8.36 7.68 7.47 5.83 5.83 19.12 12.56 17.60 11.95 15.67 11.09 16.41 11.41 14.81 10.71 12.66 9.81 13.59 10.20 11.83 9.47 9.29 8.47 19.22 14.06 17.78 13.39 15.95 12.56 16.54 12.82 15.01 12.15 13.00 11.29 13.74 11.60 12.08 10.91 9.98 9.98 CWD 175 HEATING DUTIES Room Air On wb /C/%RH db /C 20 12 10 50% 10 50% 10 50% 10 50% 10 50% 10 50% 15 50% 15 50% 15 50% 15 50% 15 50% 15 50% 20 50% 20 50% 20 50% 20 50% 20 50% 20 50% 25 50% 25 50% 25 50% 25 50% 25 50% 25 50% LPHW Temperature IN /C OUT /C 80 70 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 90 80 90 75 80 70 80 65 65 55 65 50 Minimum Speed 0.350 m3/s Total 5.64 7.81 7.46 6.73 6.37 5.11 4.75 7.26 6.91 6.18 5.83 4.57 4.20 6.71 6.36 5.64 5.29 4.03 3.67 6.16 5.82 5.10 4.74 3.50 3.13 -10- Medium Speed 0.510 m3/s Total 6.92 9.57 9.13 8.25 7.80 6.26 5.80 8.90 8.46 7.58 7.13 5.60 5.14 8.23 7.79 6.91 6.47 4.94 4.48 7.56 7.13 6.25 5.81 4.28 3.82 Maximum Speed 0.600 m3/s Total 7.53 10.42 9.93 8.98 8.49 6.81 6.31 9.69 9.21 8.25 7.76 6.09 5.58 8.96 8.48 7.53 7.04 5.37 4.87 8.23 7.76 6.80 6.32 4.66 4.15 WATER VOLUME IN COILS (litres) COIL CWD 25 CWD 45 CWD 65 CWD 95 CWD 105 CWD 115 CWD 165 COOLING 0.956 1.595 2.625 3.15 3.9 3.9 5.78 CWD 175 5.78 HEATING 0.134 0.21 0.31 0.4 0.40 0.40 0.58 0.58 EXTERNAL RESISTANCE v AIR VOLUME and DUTY TABLES Conditions: TOTAL COOLING 27/C db/19/C wb. Flow 6/C Return 11/C TOTAL HEATING 20/C db/12/C wb. Flow 80/C Return 70/C With all front discharge spigots fitted CWD 25 Pressure (Pa) 0 15 30 50 60 75 MINIMUM SPEED Air flow m³/s Cooling kW Heating kW 0.056 1.48 0.78 0.051 1.37 0.74 0.048 1.31 0.71 0.043 1.20 0.67 0.038 1.08 0.62 0.032 0.93 0.56 MEDIUM SPEED Air flow m³/s Cooling kW Heating kW 0.099 2.21 1.06 0.095 2.15 1.04 0.090 2.07 1.01 0.082 1.95 0.96 0.077 1.86 0.93 0.069 1.72 0.87 MAXIMUM SPEED Air flow m³/s Cooling kW Heating kW 0.137 2.69 1.25 0.129 2.60 1.21 0.119 2.48 1.16 0.106 2.31 1.10 0.099 2.21 1.06 0.090 2.07 1.01 CWD 45 Pressure (Pa) 0 15 30 50 60 75 MINIMUM SPEED Air flow m³/s Cooling kW Heating kW 0.113 2.96 1.58 0.101 2.72 1.48 0.095 2.59 1.43 0.086 2.40 1.35 0.079 2.24 1.29 0.064 1.88 1.14 MEDIUM SPEED Air flow m³/s Cooling kW Heating kW 0.195 4.31 2.11 0.187 4.20 2.06 0.174 4.01 1.99 0.156 3.73 1.88 0.146 3.56 1.81 0.127 3.22 1.68 MAXIMUM SPEED Air flow m³/s Cooling kW Heating kW 0.270 5.23 2.48 0.255 5.07 2.41 0.234 4.82 2.31 0.209 4.50 2.18 0.195 4.31 2.12 0.177 4.05 2.00 CWD 65 Pressure (Pa) 0 15 30 50 60 75 MINIMUM SPEED Air flow m³/s Cooling kW Heating kW 0.130 3.77 2.16 0.113 3.36 1.99 0.101 3.06 1.87 0.087 2.69 1.71 0.078 2.44 1.60 0.062 1.96 1.39 MEDIUM SPEED Air flow m³/s Cooling kW Heating kW 0.224 5.70 2.92 0.214 5.52 2.85 0.201 5.27 2.76 0.184 4.94 2.63 0.174 4.74 2.55 0.154 4.32 2.38 MAXIMUM SPEED Air flow m³/s Cooling kW Heating kW 0.331 7.37 3.59 0.316 7.16 3.51 0.295 6.86 3.38 0.270 6.47 3.23 0.258 6.28 3.15 0.232 5.84 2.98 CWD 95 Pressure (Pa) 0 15 30 50 60 75 MINIMUM SPEED Air flow m³/s Cooling kW Heating kW 0.209 5.80 3.19 0.198 5.56 3.09 0.173 5.00 2.86 0.136 4.09 2.49 0.106 3.29 2.15 0.066 2.06 1.61 MEDIUM SPEED Air flow m³/s Cooling kW Heating kW 0.324 7.96 4.05 0.311 7.74 3.96 0.288 7.34 3.80 0.255 6.73 3.56 0.217 5.97 3.25 0.181 5.18 2.94 MAXIMUM SPEED Air flow m³/s Cooling kW Heating kW 0.421 9.44 4.64 0.404 9.20 4.55 0.377 8.80 4.39 0.346 8.32 4.19 0.325 7.98 4.05 0.285 7.29 3.78 CWD 105 Pressure (Pa) 0 15 30 50 60 75 MINIMUM SPEED Air flow m³/s Cooling kW Heating kW 0.212 6.56 3.21 0.194 6.10 3.06 0.165 5.32 2.79 0.134 4.43 2.47 0.103 3.47 2.12 0.067 2.28 1.63 MEDIUM SPEED Air flow m³/s Cooling kW Heating kW 0.319 9.00 4.02 0.306 8.73 3.93 0.282 8.21 3.76 0.244 7.34 3.47 0.210 6.51 3.20 0.173 5.54 2.86 MAXIMUM SPEED Air flow m³/s Cooling kW Heating kW 0.416 10.86 4.62 0.399 10.55 4.52 0.370 10.01 4.34 0.335 9.32 4.12 0.313 8.88 3.98 0.272 7.98 3.69 CWD 115 Pressure (Pa) 0 15 30 50 60 75 MINIMUM SPEED Air flow m³/s Cooling kW Heating kW 0.242 7.29 3.46 0.224 6.68 3.31 0.188 5.94 3.00 0.158 5.12 2.72 0.141 4.63 2.55 0.102 3.44 2.10 MEDIUM SPEED Air flow m³/s Cooling kW Heating kW 0.360 9.82 4.28 0.340 9.43 4.15 0.320 9.02 4.02 0.271 7.96 3.68 0.239 7.22 3.43 0.200 6.25 3.11 MAXIMUM SPEED Air flow m³/s Cooling kW Heating kW 0.433 11.15 4.71 0.411 10.77 4.59 0.400 10.57 4.53 0.333 9.29 4.09 0.312 8.85 3.97 0.261 7.73 3.60 CWD 165 Pressure (Pa) 0 15 30 50 60 75 MINIMUM SPEED Cooling kW Heating kW 9.52 4.98 9.09 4.83 8.65 4.67 8.50 4.61 8.06 4.45 7.15 4.10 MEDIUM SPEED Cooling kW Heating kW 14.77 6.77 14.10 6.55 13.41 6.31 12.93 6.15 12.44 5.99 11.94 5.82 MAXIMUM SPEED Cooling kW Heating kW 16.65 7.40 16.25 7.26 16.05 7.20 14.55 6.70 13.41 6.31 13.17 6.23 CWD 175 Pressure (Pa) 0 15 30 50 60 75 0.280 0.265 0.250 0.245 0.230 0.200 MINIMUM SPEED Air flow m³/s Cooling kW Heating kW 0.380 12.19 5.90 0.360 11.68 5.73 0.350 11.42 5.64 0.330 10.90 5.46 0.320 10.63 5.37 0.300 10.08 5.18 0.490 0.460 0.430 0.410 0.390 0.370 MEDIUM SPEED Air flow m³/s Cooling kW Heating kW 0.530 15.63 7.06 0.520 15.42 6.99 0.510 15.21 6.92 0.450 13.64 6.39 0.420 13.17 6.23 0.410 12.68 6.07 -11- 0.580 0.560 0.550 0.480 0.430 0.420 MAXIMUM SPEED Air flow m³/s Cooling kW Heating kW 0.670 18.35 7.97 0.630 17.61 7.72 0.600 17.04 7.53 0.580 16.65 7.40 0.560 16.25 7.26 0.540 15.84 7.13 OPTIONAL ELECTRIC HEATING, (at 240V, 50Hz) CWD ELECTRIC HEATER (kW) 25 1.0 45 2.0 65 2.5 95 4.0 105 4.0 115 4.0 165 4.0 175 4.0 SOUND PRESSURE LEVELS CWD. (Sound pressure levels are for a typical installation and must be used for guidance only. Refer to the sound power data below for more accurate figures). MIN MED MAX MODEL dBA NC dBA NC dBA NC 25 32 28 38 32 43 36 45 35 28 42 36 47 42 65 33 30 40 34 46 40 95 36 29 41 35 47 40 105 35 28 40 34 45 39 115 39 34 44 39 47 42 165 35 30 47 43 48 44 175 44 40 48 44 51 46 SOUND POWER AT INLET AND BREAK-OUT SPEED Model MIN MED MAX 1. Sound Pressure Levels are dB relative to 2 x 10-5N/m2. 2. All readings at 3m distance, 1m below units running in a standard hotel bedroom. SOUND POWER AT DISCHARGE 125Hz 250Hz 500Hz 1KHz 2KHz 4KHz 125Hz 250Hz 500Hz 1KHz 2KHz 4KHz 25 46.1 43.6 43.2 37.6 32.5 30.4 38.1 32.4 36.5 34.9 35.8 37.3 45 52.1 50.8 47.5 42.2 35.4 31.5 40.8 34.4 37.7 32.5 32.8 34.1 65 46.6 46.4 44.8 39.4 29.6 36.6 35.4 29.6 35.4 31.4 32.8 33.5 95 55.6 52.9 48.3 43.2 36.9 34.8 42.7 36.8 38.5 33.8 32.7 33.4 105 54.6 51.6 46.5 41.8 36.7 33.9 40.2 36.4 38.2 34.1 32.9 32.6 115 56.9 55.2 50.5 45.2 40.3 41.9 44.8 39.4 41.1 35.7 32.8 32.3 165 58.4 47.4 48.7 44.4 32.6 25.6 34.1 31.9 28.4 23.9 18.5 21.3 175 61.5 56.2 55.6 54.4 46.3 36.6 42.6 41.8 36.0 26.1 18.5 21.2 25 53.7 51.3 49.6 45.5 39.7 32.6 45.9 39.8 43.4 40.4 36.8 37.5 45 58.3 59.5 55.1 50.2 43.2 38.1 47.1 43.4 44.8 39.9 35.4 34.1 65 53.5 53.4 51.9 48.3 41.4 38.7 41.9 34.8 37.5 38.1 34.9 33.9 95 60.6 59.2 54.1 49.3 43.2 38.9 46.8 42.2 44.1 39.8 34.7 33.4 105 59.7 58.4 52.8 47.8 40.7 37.5 46.7 42.4 44.4 40.4 35.6 33.5 115 61.2 60.1 55.8 52.3 45.7 42.7 49.3 44.8 46.4 42.8 35.7 33.2 165 64.3 60.0 58.1 56.6 50.2 42.3 47.2 45.4 39.0 29.9 22.1 21.2 175 65.6 61.8 59.0 57.7 51.8 44.5 48.9 47.1 40.5 30.2 23.5 21.2 25 57.2 55.4 52.9 49.2 44.4 35.9 49.9 44.6 47.3 44.9 40.5 37.7 45 61.6 65.4 60.2 55.4 49.1 43.7 51.9 50.4 51.1 46.1 40.7 37.5 65 58.6 59.9 57.1 54.2 48.5 45.2 49.8 43.4 46.6 45.8 40.7 37.2 95 64.6 64.9 58.2 53.9 48.3 44.7 50.2 48.2 49.1 45.4 39.3 38.6 105 64.1 64.3 56.9 52.8 45.6 41.4 49.8 48.1 49.2 45.5 39.4 35.7 115 64.2 64.2 59.3 56.1 49.5 46.1 51.7 48.5 49.4 46.3 39.2 35.9 165 65.7 61.8 59.5 57.9 52.1 44.6 49.8 48.0 41.1 31.5 23.6 21.2 175 67.1 63.7 61.2 60.0 54.8 47.4 51.0 49.2 42.0 31.5 23.6 21.2 ELECTRICAL DATA CWD Maximum Running Current (Amps at 230V, 50Hz). Model 25 45 65 95 Standard 0.4 0.6 0.7 0.8 0.8 0.8 1.9 2.1 With Electric Htg 4.4 8.6 10.7 16.8 16.8 16.8 18.2 18.8 -12- 105 115 165 175 RECOMMENDED FUSE SIZES (Amps) Model 25 45 65 95 105 115 165 175 Standard 5 5 5 5 5 5 5 5 With Electric Htg 10 10 16 20 20 20 25 25 CWD FAN COIL UNIT INSTALLATION CWD fan coil units are designed to be installed within a ceiling void. Air discharge should be via insulated ducting, connected to 200mm diameter spigots (250mm diameter spigots also available) and to appropriately sized discharge plenums/grilles. Ducting and discharge facilities are supplied by others and are not included with the fan coil units. Similarly, return air arrangements, via ducting or to the ceiling void, must also be provided. The installer must ensure that the mounting suspension points are capable of supporting the operating weight of the unit, (refer to the table below). UNIT FIXING NOTE: If used, a condensate pump kit should be fitted prior to hanging the unit and connecting the pipework. 1. Before lifting the unit into position, mark out the four outer fixing points as shown below, and fit suspension rods of appropriate length and diameter, (minimum recommended thread size M8). Two inner, central fixing points are available for installer convenience. DO NOT lift the unit by its spigots, drain tray or electrics box when raising it into position. MODEL 25 A 463 B 785 C CRS D CRS E CRS F 427 344 688 260 G 332 H J K OPERATING WEIGHT (kg) 130 195 195 22 PIPE CONNECTIONS ( mm OD) W X Y Z 15 15 15 15 DRAIN TRAY 15 No. OF OUTLETS MINIMUM No. OF OUTLETS TO BE USED 3 (A,C,E) 1 45 733 785 697 344 688 260 342 130 195 195 33 15 15 15 15 15 4 (A,B,D,E) 2 65 1103 785 1067 344 688 260 352 130 195 195 44 22 22 15 15 15 4 (A,B,D,E) 2 95 1383 785 1347 344 688 260 392 120 205 205 56 22 22 15 15 15 5 3 105 1383 785 1347 344 688 260 392 120 205 205 58 22 22 15 15 15 5 3 115 1383 785 1347 344 688 260 392 120 205 205 59 22 22 15 15 15 5 3 165 1383 835 1347 394 738 315 392 130 205 195 86 22 22 15 15 15 5 3 175 1383 835 1347 394 738 315 392 130 205 195 86 22 22 15 15 15 5 3 -13- 2. Lift the unit into position and secure with appropriate fixings (as shown). The use of lock nuts will stabilize the unit. NOTE: The drain tray is designed with a natural fall to ensure complete drainage. It is essential, for the correct operation of the condensate removal system, that the unit is square and level. RETURN AIR PLENUM When installing a unit fitted with a return air plenum, there are eight fixing points as shown below. NOTE: The centre fixings must always be used to support the weight of the unit correctly, (refer to the table below). MODEL A B C D E CRS CRS CRS F G H J K OPERATING WEIGHT (kg) PIPE CONNECTIONS ( mm OD) W X Y Z DRAIN TRAY No. OF OUTLETS MINIMUM No. OF OUTLETS TO BE USED 1 25 463 1076 427 344 981 260 332 421 486 486 26 15 15 15 15 15 3 (A,C,E) 45 733 1076 697 344 981 260 342 421 486 486 39 15 15 15 15 15 4 (A,B,D,E) 2 65 1103 1076 1067 344 981 260 352 421 486 486 52 22 22 15 15 15 4 (A,B,D,E) 2 3 95 1383 1076 1347 344 981 260 392 411 496 496 66 22 22 15 15 15 5 105 1383 1076 1347 344 98 260 392 411 496 496 68 22 22 15 15 15 5 3 115 1383 1076 1347 344 981 260 392 411 496 496 69 22 22 15 15 15 5 3 165 1383 1126 1347 394 1031 315 392 421 496 486 96 22 22 15 15 15 5 3 175 1383 1126 1347 394 1031 315 392 421 496 486 96 22 22 15 15 15 5 3 -14- PIPE CONNECTIONS CWD UNITS a. Connect the flow and return pipework as indicated in the diagrams and tables on the two previous pages. It is recommended that compression fittings are used for ease of installation b. If using compression fittings, two spanners should be used when tightening to prevent twisting and damage to the coil terminals. c. Coil pipe connections are 15mm OD on all LPHW, 15mm OD on Chilled Water sizes 25 and 45, 22mm OD on Chilled Water sizes 65 to 175. d. When making the condensate drain connection, use a flexible or compression connector to allow removal of the drain tray for cleaning and maintenance. The condensate outlet connection is 15mm OD. ELECTRICAL CONNECTIONS AND CONTROLS Mains, control and interconnecting cables must be supplied and fitted by the installer. Installer wiring must be carried out in accordance with local and national regulations. Cables must be size compatible with the recommended fuse for a given system. An isolator switch should be positioned within easy reach of the unit. If slave units are connected to a standard unit, isolation of any slave MUST also isolate the standard unit. The equipment MUST be earthed. Cable glands suitable for stranded cables are supplied and should be used to secure all cables. Installers must supply a method of securing any solid sheathed cable. CWD UNIT WIRING Remove the electrics box cover (2 screws) and connect a suitably fused and isolated mains supply. All site fitted controls should be connected as specified on the wiring diagram found on the inside face of the electric box cover and on pages 17 to 18 of this manual. DUCTWORK Connect discharge ductwork to the spigots provided. Spigot positions are shown below. Spigots are designed to accept 200mm diameter ducting (250mm diameter spigots are available as an option). The installation engineer must ensure that insulated ducting is used and that the complete spigot exterior is insulated up to the unit casing to prevent condensation forming. B C MAXIMUM No. OF SPIGOTS MINIMUM NUMBER OF SPIGOTS REQUIRED FRONT SIDES CWD A 25 195 --- --- 1 2 1 45 184 476 --- 2 2 2 65 322 708 --- 2 2 2 3 95 270 655 1040 3 2 105 270 655 1040 3 2 3 115 270 655 1040 3 2 3 165 270 655 1040 3 2 3 175 270 655 1040 3 2 3 -15- WHEN INSTALLATION HAS BEEN COMPLETED - CHECK:1. All pipework and joints for leaks 2. That all pipes and fittings are insulated 3. That terminals are tight and that no wire cores are exposed 4. That duct connections are air tight and insulated where necessary. 5. Filters are clean and undamaged MAINTENANCE A Every 2 months Inspect the filters and clean or replace as necessary B Every 6 months Inspect and clean the fan rotors. C Every 12 months 1. Check the unit fixing 2. Ensure that the fan motor and fan deck fixings are tight. 3. Check the unit wiring for damage and ensure that all terminals are tight. HYDRAULIC RESISTANCES - COOLING AND HEATING COILS -16- WIRING DIAGRAMS CWD 25 CWD 45 - 115 -17- CWD 165 CWD 175 -18- -19- INDOOR UNIT EXPLODED VIEW WITH COMPONENT IDENTIFICATION ITEM DESCRIPTION 1 ACCESS PANEL 2 DRAIN TRAY 3 COIL AND HEADER 4 FAN DECK ASSEMBLY 5 SPIGOT (200mm 6 TERMINAL BLOCK (16A) 7 FILTER ASSEMBLY -20-