Wiring Instructions Dry Contact Wall Switch by Draper Wiring Diagram for Low Voltage Dry Contact Wall Switch with LVC-IV White-Neutral (Common) to screen & 110V-120V AC Red-to screen (directional) Brown-to screen (directional) Yellow-to 110V-120V AC Black-to 110V-120V AC Green-Ground IR Eye Input RS232/485 Inputs/Outputs FUSE - 3.15 AMP 250 VAC 5x20mm Low Voltage Trigger 3-28 VDC Dashed wiring by electrician Low voltage wiring to switch by others LVC-IV 3 Button Wall Switch DOWN - Black COM - White UP - Red 1 Wire Screen according to diagram. 2 Press “Up.” If screen goes down, switch red and black wires at switch. Motor directions will now be reversed. Wire to connect power to LVC-IV should be between 18 AWG and 12 AWG (solid or stranded) 2 conductors with ground. Wire size needs to be sufficient to carry the motor load. Red and Black wires are the “open” and “close” leads from the motor. The LVC-IV comes enclosed in a metal box conforming to the National Electrical Code (NEC) with appropriate spacing between the wires and any exposed parts of the box. Wire to connect the switch to the dry contacts on the LVC-IV must be 3-conductor. Copyright ©2015 Draper Inc. Form DryContactWallSwitch_Wiring15 Printed in U.S.A. If you encounter any difficulties installing/wiring your Dry Contact Wall Switch, call your dealer or Draper, Inc., Spiceland, Ind., (765) 987-7999; or fax (765) 987-7142. Wiring Instructions 230V Dry Contact Wall Switch by Draper Wiring Diagram for Low Voltage Dry Contact Wall Switch with LVC-IV Low Voltage Trigger 3-28 VDC White-Neutral (Common) to screen & 230V AC Red-to screen (directional) Brown-to screen (directional) Yellow-to 230V AC Black-to 230V AC Green-Ground IR Eye Input FUSE - 3.15 AMP 250 VAC 5x20mm RS232/485 Inputs/Outputs Dashed wiring by electrician Low voltage wiring to switch by others LVC-IV 3 Button Wall Switch DOWN - Black COM - White UP - Red 1 Wire Screen according to diagram. 2 Press “Up.” If screen goes down, switch red and black wires at switch. Motor directions will now be reversed. Wire to connect power to LVC-IV should be between 18 AWG and 12 AWG (solid or stranded) 2 conductors with ground. Wire size needs to be sufficient to carry the motor load. Red and Black wires are the “open” and “close” leads from the motor. The LVC-IV comes enclosed in a metal box with appropriate spacing between the wires and any exposed parts of the box. Wire to connect the switch to the dry contacts on the LVC-IV must be 3-conductor. Copyright ©2015 Draper Inc. Form DryContactWallSwitch-230V_Wiring15 Printed in U.S.A. If you encounter any difficulties installing/wiring your Dry Contact Wall Switch, call your dealer or Draper, Inc., Spiceland, Ind., (765) 987-7999; or fax (765) 987-7142.