Main line component Safety Precautions Read this before starting use. Please refer to Intro 43 for general precautions. Refrigerating type dryer GT series WARNING Manufacturer's Liability The manufacturer shall not be responsible for the following matters: • Major errors caused during use by user. • Illegal modifications or repairs using nonstandard parts by user. WARNING General Matters This product shall not be used for applications other than dehumidification of compressed air. WARNING 1 During transport, this product shall not be laid on its side, and vibration and impact shall not be applied. 2 Move the product with a fork lift or by suspension as shown in the drawing. 3 When suspending the product, use suspension hooks and rope, etc. The suspension angle must be 45° and over. CAUTION <Ambient temperature> 1 Do not use this product in a place exceeding the maximum working temperature. 2 Do not install this product where it will be subject to radiated heat. 3 If the maximum working temperature may be exceeded, install ventilation fans or provide an air inlet, etc. 4 Do not use this product where the temperature is lower than the minimum working temperature. <Location> 5 Install this product indoors. When using it outdoors, designate the option symbol "O". (Protection class IPX3 or equivalent) 78 6 Install this product in a well-ventilated place with low levels of dust and dirt. 7 Install this product where it will not be subject to rain. 8 Do not use this product in highly-humid places where dew could condense. 9 Avoid using this product where it may be subject to direct sunlight, or where heat could be generated. 10 Do not use this product where corrosive gases are present. Transport 45° and over Extrude claws Installation <Floor> 11 Install this product on a stable, nonvibrating floor. 12 Install this product on a flat surface. 13 If the foundation is soft, provide foundation work. 14 Anchor bolt positions and hole dimensions are shown in the outline dimension drawing. 15 Refer to "Introduction to Accessories" on page 75 for recommended anchor bolts. <Vibration> 16 When using the reciprocating compressor, use a flexible tube or high pressure rubber hose for piping with the air dryer so that vibration will be adsorbed. <Maintenance space> 17 Ensure space to provide good ventilation and make maintenance and inspections easier. Front and both sides: 600 mm and over in each direction (Open at least 1000 mm on the front, both sides and back for the GT7710W to 7960W.) Top: 600 mm and over (When using air cooling, check that exhausted heat does not enter the dryer intake port.) Refrigerating type dryer Desiccant type dryer High polymer membrane dryer Air filter Automatic drain other Piping CAUTION <Air piping> 1 Pipe the air dryer as shown below. For 24-hour operation: A parallel installation for emergencies is recommended. Use 1 unit for normal operation, and the other unit as a spare. <Drain piping> 6 Connect the drain pipe to the drain. Sludge is removed from the manual drain, so always connect a drain pipe to the drain. 7 From air compressor To terminal line Use a drain pipe with a bore size of 7 and over. Keep the length to within 2m, and release the discharge end to the atmosphere. F.R.L (Module) F.R.L (Separate) Small F.R. Precise R. Electro pneumatic R. Auxiliary Flow control valve Gate valve 8 9 For intermittent operation: Install a bypass pipe for maintenance. From air compressor To terminal line 10 Bypass pipe Gate valve If drain piping slopes upward or if piping is too long, drainage may not be discharged. Pipe with a downward slope so drainage flows naturally. Silencer If oil enters drainage, it must be drained and treated. Contact an industrial waste specialist for treatment. Vacuum F. Drainage is discharged using air pressure. Securely fix the drain discharge tube, etc., so it does not sway during drain discharge. <Cooling water piping> 11 Check the cooling water inlet and outlet, and connect pipes. 2 Stainless steel or galvanized steel pipes (white pipes) are recommended for pipe materials. Flush pipes before connecting. 12 13 3 When piping is already laid, when using black pipes, or when using an oil-free air compressor, and large amounts of dirt, etc., form in pipes, install a main line P filter before the dryer. 14 Provide a water discharge outlet or stop valve so maintenance can be done. Design piping so weight of pipes is not applied to the dryer. Use piping that withstands working pressure and temperature. Check that no water leaks from connections. Design piping so weight of pipes is not applied to the dryer. 15 Use galvanized steel pipes, etc., for pipe materials. Flush pipes before connecting. 5 Use piping that withstands working pressure and temperature. Check that no air leaks from connections. 16 Provide insulation if ambient temperature drops below 0°C when stopped during winter. 17 Cooling and replenishment water quality must comply with "Refrigerating and Air Conditioning Device Water Quality Guidelines" of the Japan Refrigeration and Air Conditioning Industry Association (JRA-GL-02). Refer to page 19 for details. Joint / tube Vacuum R. Vacuum generator Vacuum auxiliary / pad Mechanical pressure SW Electronic pressure SW Electronic dif. pres. SW Seating / close contact conf. SW Pressure SW for coolant Flow sensor for air Total air system Water cooling refrigerator Flow sensor for water Main line unit Refrigerating type dryer GT 4 Check valve / others 79 Main line component Safety Precautions Read this before starting use. Please refer to Intro 43 for general precautions. Refrigerating type dryer GT series Wiring CAUTION 1 Use this product within the power voltage range given in specifications. 2 Install a ground leakage breaker on the main power source. CAUTION <Air quality> 1 Do not use intake air that contains corrosive gases, chemicals, organic solvents, or flammable gases. 3 Correctly and securely connect power, signal, operation, and ground cables. Do not connect the ground cable to a water pipe, gas pipe, or lightning rod. 4 Select wires with suitable capacities. Pneumatic circuit <Air temperature> 3 Do not use air that exceeds the maximum intake temperature. 4 <Filter> 2 Refer to system selection examples on Intro 4 for details on the filter used around the product. CAUTION 1 Air cooling has a standard dust filter. Clean the dust filter with a vacuum cleaner or air-blowing once a month. Replace the filter if it is heavily contaminated. CAUTION 1 80 This product has a Class 2 pressurized container withstand pressure proof certificate. This certificate must be kept in safekeeping while using this product. (Applications to the Labor Standards Supervision Office are no longer required. This applies in Japan.) If the intake temperature is high, install an after cooler, etc., and lower air to the maximum intake temperature. Drainage generated in the after cooler must be removed before the dryer. Maintenance 2 With water cooling, if water deposits, etc., adhere to the water cooling condenser, performance may drop and the dryer could stop abnormally. Wash the water cooling condenser once every 6 months. Connecting piping for washing is recommended when connecting cooling water piping. Miscellaneous 2 This product uses non-ozone depleting Freon gas. However, to protect the environment, collect Freon gas when disposing of the product. (Treat Freon gas according to local laws and ordinances.) Contact CKD or a specialist for collection of Freon gas. Main line component Safety precautions Always read this section before starting use. Refer to "Pneumatic, vacuum and auxiliary components No. CB-024SA" for general precautions. Refrigerating type air dryer GX Series Manufacturer's Liability The operator makes illegal modifications or repairs the product using nonstandard parts. WARNING The manufacturer cannot be held liable in the following cases: Serious errors in use occur due to the operator. Design & Selection CAUTION WARNING <Applications> Use for applications other than dehumidifying compressed air is prohibited. <Quality of compressed air> Do not use this product if inlet air contains corrosive gases, chemicals, organic solvents, or combustible gases. Do not use this product for caisson shields or medical apparatuses used for respiration. <Air temperature> Do not exceed the maximum inlet air temperature during use. Failure to observe this could result in personnel injury. Do not install this product on transportation devices such as vehicles or ships. Vibration, etc., could cause damage to internal components. If the inlet air temperature is high, install an after cooler, etc., and lower the temperature to the maximum inlet air temperature or less. Drainage generated in the after cooler must be removed before the dryer is reached. Transportation This product contains less than 12 kg of refrigerant (R-407C). Follow all applicable laws when transporting this product by ground, sea or air. Transportation Transportation by crane WARNING Tilting this product or applying vibration or impact during transportation is prohibited. Transportation by forklift (Series GX3111 to 3137, GX5111 to 5137) Supporting plate The supporting plate (B) must be 100 mm longer than the dryer width (A). (A) (B) Supporting plate (4 points) Protect the panel from damage. Product The end of fork must project from the opposite side. Provide protection between the suppor ting plate and dryer to prevent damage to the panel. Intro 2 Installation & Adjustment WARNING <Electric wiring> Use the product within the specified power voltage range. <Adjustment and operation> Do not start or stop frequently, or failures could occur. <Floor> Install the product on a vibration-free floor. Install the product on a flat floor. Provide foundation work if the ground is soft. The anchor bolt position and hole dimensions are given in the outline drawing. When a remote operation circuit (option M) is provided to operate the dryer remotely, the following considerations must be made for the system: Start and stop the dryer less than ten times an hour. After restarting, wait at least five minutes before stopping again. Stop for at least three minutes. <Vibration> When using a reciprocating compressor, use a flexible tube or high-pressure rubber hose in part of piping with the air dryer to absorb vibration. Install an overload protection ground-fault circuit breaker on the main power supply to provide isolated overload protection and to prevent electrical shock from current leakage. <Maintenance space> Secure the ventilation and maintenance spaces as followings. 600mm or wider in each 4 directions 600mm or higher in the top Always connect the ground. CAUTION <Ambient temperature> Do not use the product in a location where the temperature is higher than the maximum working temperature. Do not install the product where it is subjected to radiated heat. If maximum working pressure is exceeded, install a ventilation fan or air inlet, etc. <Air piping> Pipe the dryer as the following diagram. When operating 24 hours, parallel installation is recommended against emergencies. One unit is used for normal operation, while another unit is used as the backup unit. For intermittent operation: Install the by-pass piping for maintenance. Do not use the product in a location where the temperature is lower than the minimum working temperature. <Location> Install the product indoors. (GX3111 to 3137, GX5111 to 5137 do not include a Y type strainer.) Install the product in a well-ventilated place free of dirt and dust. Install the enclosed Y strainer to prevent dirt in piping from entering the dryer. (Series: GX3108, GX5103 to 5108) Install the product in the place that separated from rain or water splash. Design piping so that pipe weight is not applied on the product. Do not install the product where high levels of humidity or dew could condense. Use piping that sufficiently withstands working pressure. Check that air does not leak from connections. Avoid using the product in direct sunlight or where heat is generated. Galvanized steel pipes (white) are recommended. Use stainless steel pipes based on specifications and applications. Do not use the product in a location that has a corrosive gas. Intro 3 <Drain piping method> Connect the drain pipe to the drain port. Use a drain pipe with a bore of at least 7. Keep the length to within 2 m, and release the discharge end into the atmosphere. The drain piping port is Rc1/4. If the drain piping slopes upward or if piping is too long, back pressure will be applied and drainage may not be discharged. Pipe with a downward slope so that drainage flows naturally. Drain treatment is necessary if oil could get into the drain. Contact an industrial waste specialist for treatment. Drainage is regularly discharged using air pressure. Securely fix drain discharge tubing, etc., so that it does not move during drain discharge. Keep the drain discharge manual cock completely closed during normal operation. Use this manual cock to remove drainage during maintenance. During use & Maintenance WARNING <Freon collection> This product is subject to laws related to the collection and destruction of freon in specific products (freon collection and destruction laws). Collect freon gas when repairing or disposing of the product. Consult with CKD for Freon gas collection. <Periodical maintenance part> To ensure long use, regularly inspect maintenance parts and replace them based on the standard replacement cycle. Refer to the Instruction Manual enclosed with the product for details. CAUTION <Repair parts> To ensure long use, regularly inspect wear and replace parts. Refer to the instruction manual enclosed with the product for details. Intro 4