LEDstixx® Festoon

advertisement
www.sylvania.com/LED
LEDstixx® Festoon
For Commercial Decorative Lighting Applications
Key Features & Benefits
•Significant energy savings! Uses
up to 90% less power than traditional Festoon lamps
•Plug-n-play compatibility with
existing 12V AC Systems
•Simple to install
•High efficacy, up to 46LPW
•High CRI
The SYLVANIA LEDstixx Festoon offers a unique LED lighting
solution featuring optical properties optimized for numerous
applications including cove lighting, undercabinet lighting, accent lighting, and display lighting.
•No warm-up time, instant on
with full light output and stable color
•No UV or IR emissions
•Long life: up to 50,000 hours
(L70)
•Available in 2700K, 3000K and
4000K color temperatures
Product Offering
Ordering Abbreviation
LSX/Festoon/05/12AC/827
LSX/Festoon/05/12AC/830
LSX/Festoon/05/12AC/840
The very uniform, high quality light source comes in three color
temperatures of 2700K, 3000K, and 4000K. The LEDstixx Festoon is optimally paired with a 12VAC transformer.
Wattage
0.5W
0.5W
0.5W
Color
2700K
3000K
4000K
Application Information
Specifications and Certifications
Applications
• Accent lighting
• Cove lighting
• Display case lighting
• Shelf lighting
• Task lighting
• Undercabinet lighting
LED195 9/11
The LEDstixx Lighting System is UL 8750 Recognized
for the US and Canada Class 2 Unit (UL file# E320662) Specification Data
Catalog #
Type
Date
Project
Comments
Prepared by
Ordering Information
Item
Number
70936
70937
70938
Ordering Abbreviation
LSX/Festoon/05/12AC/827
LSX/Festoon/05/12AC/830
LSX/Festoon/05/12AC/840
Power1 0.5
0.5
0.5
Lumens2 20
21
23
LPW3 40
42
46
Color Temp.4 2700K
3000K
4000K
CRI
85
85
85
Notes:
1. Wattage range: 0.5W+/-0.1W at 12VAC, 60Hz.
2. Estimated light output at application operating temps. Lumens tolerance range: +/-3 lumens.
3. Lumens per watt data is based on system efficiency at 12V AC. Values based on Ta=25°C and Tj=70°C. LPW tolerance range +/-6LPW.
4. Correlated color temperature tolerance range: 2700K+/-150K, 3000K+/-200K, and 4000K+/-275K.
Ordering Guide
LSX
/
Festoon
/
05
/
12AC
/
8
27
LEDstixx
Family
Product Name
Power Designation
0.5W
Input Voltage
12V AC
CRI
8 = 85 CRI
Color Temp.
27 = 2700K
30 = 3000K
40 = 4000K
Power Supply Information
Power Supply/
Driver
Electronic Systems
Magnetic Systems
Output
RMS
12 VAC
12 VAC
Minimum
Load
1 Watt
5 Watt
Maximum Track Length Connected
to a Single Transformer
25 feet
50 feet
Operating Parameters
Parameter
Protection Rating
Maximum Junction Temperature* Viewing Angle**
Value
Dry location
70°C
120°
* Temperature to maintain 50,000 hrs. at ambient temperature of 25°C.
** Viewing angle tolerance: Refer to Photometric Information Section.
Notes:
1. Exceeding maximum ratings may damage the unit and cause potential safety hazards.
2. Elevated operating temperatures will negatively impact the service life and lumen output. Operating temperature range: -30°C to +50°C.
3. Incorrect wiring may damage the unit.
4. Not intended for use with constant current power supplies.
5. Dry location. No humidity.
Mechanical Diagram
Size
Millimeters
Inches
Length
44.5
1.75
Width
17.5
0.75
Note: Tolerance for length, width, height: +1/-0.5mm or +0.04/-0.02in.
Height
12.7
0.5
Wiring Configuration
Line Voltage
L
N
Electronic +
or
Magnetic
Transformers
LED
Load
12VAC
120VAC
Photometric Information
Directive Characteristic
I F =20mA
-30° -20° -10° 0°
1.0
10° 20°
30°
40°
50°
-50°
0.8
-60°
0.6
60°
0.4
70°
0.2
80°
-70°
-80°
0.0
-40°
-30° -20° -10° 0°
1.0
-50°
United States
OSRAM SYLVANIA
100 Endicott Street
Danvers, MA 01923
I F =20mA Ts=25C
10° 20° 30°
40°
0.8
50°
-60°
0.6
60°
-70°
0.4
70°
-80°
0.2
80°
0.0
Safety Information
WARNING: ONLY QUALIFIED PERSONNEL SHOULD PERFORM INSTALLATION.
TO AVOID ELECTRICAL SHOCK OR COMPONENT DAMAGE, DISCONNECT POWER
BEFORE ATTEMPTING INSTALLATION OF THE FIXTURES.
Failure to install the fixtures in accordance with the National Electric Code (NEC), all applicable Federal, State and
local electric codes as well as the specific Underwriters Laboratories (UL) safety standards for the installation, location and application may cause serious personal injury, death, property damage and/or product malfunction.
1. The LED Lighting System itself and all its components shall not be subjected to mechanical stress.
2. Installation of LED Lighting Systems shall be made with regard to all applicable electrical and safety standards.
Only qualified personnel should be allowed to perform installations.
3. Ensure the transformer is of adequate power to operate the total load.
4. Electrostatic Discharge (ESD) precautions shall be incorporated when handling or installing the LED Lighting
System. (For more information, reference document # LED093 ESD Protection for LED Systems.)
5. Damage by corrosion will not be honored as a materials defect claim. It is the user’s responsibility to ensure
adequate protection against corrosive agents such as moisture, condensation and other harmful elements.
6. Lighting Systems may be hot to the touch. Use caution when handling.
SYLVANIA is a registered trademark of OSRAM SYLVANIA Inc.
SEE THE WORLD IN A NEW LIGHT is a registered trademark of OSRAM SYLVANIA Inc.
LEDStixx is a registered trademark of OSRAM AG.
Specifications subject to change without notice.
LED195
Trade
Phone:
Fax:
1-800-255-5042
1-800-255-5043
National Accounts
Phone:
1-800-562-4671
Fax:
1-800-562-4674
OEM/Special Markets
Phone:
1-800-762-7191
Fax:
1-800-762-7192
Display/Optic
Phone:
1-888-677-2627
Fax:
1-800-762-7192
SYLVANIA Lighting Services
Phone:
1-800-323-0572
Fax:
1-800-537-0784
Canada
OSRAM SYLVANIA LTD.
2001 Drew Road
Mississauga, ON L5S 1S4
Trade
Phone:
Fax:
1-800-263-2852
1-800-667-6772
OEM/Special Markets/Display/Optic
Phone:
1-800-265-2852
Fax:
1-800-667-6772
SYLVANIA Lighting Services
Phone:
1-800-663-4268
Fax:
1-866-239-1278
Mexico
OSRAM MEXICO
Headquarters
Tultitlan/Edo de Mexico
011-52-55-58-99-18-50
www.sylvania.com
© 2011 OSRAM SYLVANIA 9/11
-40°
Ts=25C
Download