Please read instructions before proceeding with installation.
0-10V DIMMING
Precautions:
1. Do not touch or press LEDs against any surface as this can cause damage.
Damaged LEDs may not light and can disrupt the flow of power.
5. To help reduce the risk of electric shock, TCP strongly recommends using a sturdy
wooden or fiberglass ladder and rubber soled shoes during the installation of
the fixture.
2. DANGER—RISK OF SHOCK—DISCONNECT POWER BEFORE INSTALLATION!
6. This product must be installed in accordance with National Electrical Code (NEC)
and/or applicable local codes, by a qualified licensed electrician.
3. Handle fixture with care to avoid possible cuts or abrasions from exposed edges.
TCP suggests using work gloves when installing fixture.
7. Fixture must be grounded.
4. Check fixture for cuts or loose connections which could have occurred during
shipment. If any are found, they must be repaired before proceeding.
8. Be certain wire nuts are tight and no bare wires are exposed outside of the wire nuts.
If needed, wrap in electrical tape.
Wiring Instructions
Wire Nut
Line In
Wire Nut
Connect black wire from
power supply to black
disconnect lead and
secure with wire nut.
Wire Nut
Fixture Ground
Wire Connection
Connect white wire from
power supply to white
disconnect lead and secure
with wire nut.
To Driver
Connect green ground from
power supply to green
ground in housing and
secure with wire nut
Dimming (+) Violet
Dimming (-) Grey
Dimming (+) Violet
Dimming (-) Grey
CONNECT TO DIMMING LOW VOLTAGE
WIRING ONLY
USE ONLY UL LISTED WIRING CONNECTORS 105º
(OR GREATER) AND UL LISTED WIRING HAVING A
MINIMUM TEMPERATURE RATING AS SHOWN ON
THE FIXTURE LABEL, (OR GREATER). USE ONLY UL
LISTED CORDS. IF SUPPLIED WITH A CORD USE
WITH UL LISTED STRAIN RELIEF THAT IS RATED
FOR THE CORD.
Fixture
Installation
Recommended
Hanging Solution
Step 1: Remove the fixture from
its shipping packaging.
BUILT-IN FIXTURE SAFETY CLIP INSTRUCTION
Step 2: Install troffer into ceiling
frame as seen below;
fixture is not intended to be suspended.
LIGHT FIXTURE BODY
LIGHT FIXTURE BODY
INTEGRATED TEE LOCK,
1 PER CORNER
4 TOTAL
INTEGRATED TEE LOCK,
1 PER CORNER
4 TOTAL
Step 3: Remove a knock out in access plate.
Step 4: Connect wires as shown above.
15/
16
Fixture
Ceiling Panel
3
X 1 /8 TEE
(CUSTOMER SUPPLIED)
15/16 X 1 3/8 TEE
(CUSTOMER SUPPLIED)
15/16 x 13/8
Tee
SCALE 2.000
These instructions are not intended to cover all details or variations in your equipment or your particular requirements for installation, operation or
maintenance. Should further information on this product be needed that is not covered by these general installation instructions, please contact
the TCP Customer Service Department at phone number 800-324-1496 for further assistance.
SAVE THESE INSTRUCTIONS
TCP®
325 Campus Dr. | Aurora, Ohio 44202 | P: 800-324-1496 | tcpi.com
©TCP FEB 2016/57004