LED Troffer Instructions for 0-10V Dimming ® Please read instructions before proceeding with installation. 0-10V DIMMING Precautions: 1. Do not touch or press LEDs against any surface as this can cause damage. Damaged LEDs may not light and can disrupt the flow of power. 5. To help reduce the risk of electric shock, TCP strongly recommends using a sturdy wooden or fiberglass ladder and rubber soled shoes during the installation of the fixture. 2. DANGER—RISK OF SHOCK—DISCONNECT POWER BEFORE INSTALLATION! 6. This product must be installed in accordance with National Electrical Code (NEC) and/or applicable local codes, by a qualified licensed electrician. 3. Handle fixture with care to avoid possible cuts or abrasions from exposed edges. TCP suggests using work gloves when installing fixture. 7. Fixture must be grounded. 4. Check fixture for cuts or loose connections which could have occurred during shipment. If any are found, they must be repaired before proceeding. 8. Be certain wire nuts are tight and no bare wires are exposed outside of the wire nuts. If needed, wrap in electrical tape. Wiring Instructions Wire Nut Line In Wire Nut Connect black wire from power supply to black disconnect lead and secure with wire nut. Wire Nut Fixture Ground Wire Connection Connect white wire from power supply to white disconnect lead and secure with wire nut. To Driver Connect green ground from power supply to green ground in housing and secure with wire nut Dimming (+) Violet Dimming (-) Grey Dimming (+) Violet Dimming (-) Grey CONNECT TO DIMMING LOW VOLTAGE WIRING ONLY USE ONLY UL LISTED WIRING CONNECTORS 105º (OR GREATER) AND UL LISTED WIRING HAVING A MINIMUM TEMPERATURE RATING AS SHOWN ON THE FIXTURE LABEL, (OR GREATER). USE ONLY UL LISTED CORDS. IF SUPPLIED WITH A CORD USE WITH UL LISTED STRAIN RELIEF THAT IS RATED FOR THE CORD. Fixture Installation Recommended Hanging Solution Step 1: Remove the fixture from its shipping packaging. BUILT-IN FIXTURE SAFETY CLIP INSTRUCTION Step 2: Install troffer into ceiling frame as seen below; fixture is not intended to be suspended. LIGHT FIXTURE BODY LIGHT FIXTURE BODY INTEGRATED TEE LOCK, 1 PER CORNER 4 TOTAL INTEGRATED TEE LOCK, 1 PER CORNER 4 TOTAL Step 3: Remove a knock out in access plate. Step 4: Connect wires as shown above. 15/ 16 Fixture Ceiling Panel 3 X 1 /8 TEE (CUSTOMER SUPPLIED) 15/16 X 1 3/8 TEE (CUSTOMER SUPPLIED) 15/16 x 13/8 Tee SCALE 2.000 These instructions are not intended to cover all details or variations in your equipment or your particular requirements for installation, operation or maintenance. Should further information on this product be needed that is not covered by these general installation instructions, please contact the TCP Customer Service Department at phone number 800-324-1496 for further assistance. SAVE THESE INSTRUCTIONS TCP® 325 Campus Dr. | Aurora, Ohio 44202 | P: 800-324-1496 | tcpi.com ©TCP FEB 2016/57004