I-320 TBTS SERIES AC EMERGENCY LIGHTING EQUIPMENT P.O. BOX 11846 TUCSON, AZ 85734 (520) 294-3292 • FAX (520) 741-2837 www.iotaengineering.com INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. CAUTION – To prevent electrical shock, do not mate unit connector until installation is complete and A.C. power is supplied to the unit. 2. CAUTION – This fixture provides more than one power supply output source. To reduce the risk of electrical shock, disconnect both normal and emergency sources by turning off the A.C. branch circuit and by disconnecting the unit connector. 3. CAUTION – This is a sealed unit. The integral, high temperature Ni-Cad battery is not replaceable. Replace the entire unit when necessary and recycle or dispose of the nickel-cadmium battery properly. 4. DO NOT USE OUTDOORS. The I-320 is for use with grounded, UL Listed, damp location rated, indoor fixtures. Not for use in heated air outlets or hazardous locations. 5. The I-320 requires an unswitched A.C. power source of either 120 or 277 volts. Properly cap the unused A.C. lead. 6. When the I-320 is installed on the same branch circuit, refer to Illustration 3, Figures A and B for input wiring. When installed on separate branch circuits, refer to Illustration 3, Figures C and D for input wiring. Per NEC, the I-320 and A.C. ballast must be on the same panel board. 7. Do not mount near gas or electric heaters. 8. The I-320 should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. 9. The I-320 will cold strike and operate one 14W through 54W T5 or 2´-4´ T8 instant start or rapid start fluorescent lamp, including energy saving and 4-pin compact lamps for 90 minutes. 10. The I-320 is compatible with most A.C. ballasts (including multiple lamp) as follows: Magnetic ballasts – one lamp emergency operation. Electronic ballasts – one lamp emergency operation. 11. Suitable for use in damp locations and in enclosed and gasketed fixtures. 12. For use in 0° C minimum, 50° C maximum ambient temperatures. 13. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition, will void warranty, and result in non-compliance with UL specifications. 14. Do not use this equipment for other than intended use. 15. Install in accordance with the National Electrical Code and local regulations. 16. Installation and servicing should be performed by qualified personnel. 17. Lighting fixture manufacturers, electricians, and end-users need to ensure product system compatibility before final installation. SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS CAUTION: Before installing, make certain the A.C. power is off and the I-320 unit connector is disconnected. 1. LAMPS OPERATED The I-320 can be used with most 2′–4′ lamps. Refer to the chart on the right for the type of lamp operated in emergency mode. Contact Customer Service for answers about specific lamps. *The 6″ violet leads provide the lamp selection option. The unit is shipped from the factory with the leads disconnected and capped. When used with particular lamp types, violet leads should be connected to one another. Refer to chart for lamp selection options. OPTION LAMP TYPE EMERGENCY OPERATION *VIOLET LEADS 1 2´-4´ T8 Single Pin & Bipin One Lamp Connected 2 2´-4´ 14W-24W, 39W T5 One Lamp Connected 3 2´-4´ 28W or 54W T5 One Lamp Disconnected 4 13W-32W 4-Pin Compact One Lamp Connected 5 42W 4-Pin Compact One Lamp Disconnected 2. MOUNTING THE I-320 Remove the ballast channel cover. Mount the I-320 in the ballast channel at least 1/2″ away from the A.C. ballast(s). When battery packs are remote mounted, consult Customer Service for the maximum allowable distance between the battery pack and the lamp. 3.WIRING Refer to the wiring diagrams on the back page for the appropriate wiring of lamp(s) and ballast. Install in accordance with the National Electrical Code and local regulations. For additional wiring diagrams consult Customer Service. 4. INSTALLING THE THREADED BODY TEST SWITCH (TBTS) Recessed Troffer Fixture – Select a convenient location with proper clearance in the ballast cover and drill or punch a 7/8″ hole (1/2″ knockout). Insert the 7/8″ bushing into the hole. Push the plastic tube through the bushing. Route the leads of the TBTS through the plastic tube. Connect the LED wires from the unit to the TBTS (Red/Black or Red w/tag to Red, White/Red to White). Push the entire assembly back into the tube until the lens collar rests against the plastic tube. The plastic tube should be adjusted so that the TBTS is within ¼″ of the fixture lens. The TBTS must be visible after installation. Refer to Illustration 1. Strip Fixture – Select a convenient location on the fixture so the TBTS can be seen after installation. Allow for proper clearance inside the fixture and drill or punch a 1/2″ hole. Remove the nut from the TBTS. Push the TBTS housing into the 1/2″ hole and secure with the nut. Connect the LED wires from the unit to the TBTS (Red/Black or Red w/tag to Red, White/Red to White). Refer to Illustration 2. ATTENTION: Only connect the I-320 to the TBTS LED supplied with the unit. The LED must be replaced when replacing the unit. Illustration 1 Recessed Troffer Fixture Illustration 2 Strip Fixture FIXTURE TBTS FIXTURE BALLAST CHANNEL COVER I-320 I-320 PLASTIC TUBE 7/8" BUSHING WHITE LEAD + RED LEAD TBTS FIXTURE LENS OBSERVE PROPER POLARITY 5. WIRING THE A.C. INPUT A. When the I-320 is installed on the same branch circuit, refer to Illustration 3, Figures A and B for input wiring. When installed on separate branch circuits, refer to Illustration 3, Figures C and D for input wiring. Per NEC, the I-320 and A.C. ballast must be on the same panel board. B. The I-320 requires an unswitched A.C. power source of either 120 or 277 volts; therefore, when used with switched fixtures, the I-320 input must be wired ahead of the switch. Refer to Illustration 3 for switched and un- switched fixture wiring diagrams. C.Refer to the wiring diagrams on the back page for the proper wiring. For wiring diagrams of ballasts not shown, consult our Customer Service. Page 2 6. BALLAST WIRING BLOCK DIAGRAM Illustration 3 SAME BRANCH CIRCUIT: A. Switched Fixture B. Unswitched Fixture BLACK WALL SWITCH 1 Select proper voltage WHITE WHITE HOT A.C. LINE ➀ WHT/BLK WHT/BLK (277V) ORG (277V) ORG (120V) BLK 2 Use either WHT/BLK WHT 2 WHT/BLK COMMON WHT TBTS ➀ I-320 EMERGENCY BALLAST WHT TBTS (+) RED/BLK OR RED W/TAG 2 Use either WHT/BLK lead for wiring to common. 2 Use either WHT/BLK 2 2 ➀ WHITE WHT A.C. BALLAST WHT/BLK (277V) ORG (120V) BLK WHITE 2 2 EM CIRCUIT HOT I-320 EMERGENCY BALLAST (+) RED/BLK OR RED W/TAG ➀ WHT TBTS A.C. BALLAST WHT/BLK WHT/BLK (277V) ORG (120V) BLK WHT EM CIRCUIT COMMON WHT/RED (+) RED BLACK A.C. BALLAST CIRCUIT COMMON WHT/BLK WHT EM CIRCUIT COMMON TBTS A.C. BALLAST CIRCUIT HOT BLACK EM CIRCUIT HOT lead for wiring to common. D. Unswitched Fixture WALL SWITCH A.C. BALLAST CIRCUIT COMMON (+) RED/BLK OR RED W/TAG ➀ Select proper voltage lead. Cap unused lead. C. Switched Fixture lead. Cap unused lead. 7.LABELS WHT/RED (+) RED 2 Use either WHT/BLK lead for wiring to common. 1 Select proper voltage I-320 EMERGENCY BALLAST WHT/BLK COMMON ➀ Select proper voltage lead. Cap unused lead. A.C. BALLAST CIRCUIT HOT (120V) BLK WHT 2 WHT/RED (+) RED SEPARATE BRANCH CIRCUIT: A.C. BALLAST HOT A.C. LINE lead. Cap unused lead. lead for wiring to common. BLACK A.C. BALLAST I-320 EMERGENCY BALLAST WHT/RED (+) RED (+) RED/BLK OR RED W/TAG ➀ Select proper voltage lead. Cap unused lead. ➀ Select proper voltage lead. Cap unused lead. 2 Use either WHT/BLK lead for wiring to common. 2 Use either WHT/BLK lead for wiring to common. Attach the appropriate labels adjacent to the TBTS. Annotate Re-lamping label for lamp type and wattage. The Caution and the Re-lamping labels must be on the fixture in a readily visible location to anyone attempting to service the fixture. 8. COMPLETING INSTALLATION When the installation is complete, switch the A.C. power on and join the I-320 unit connector. OPERATION Normal Mode – A.C. power is present. The A.C. ballast operates the fluorescent lamp(s) as intended. The I-320 is in the standby charging mode. The TBTS will be lit providing a visual indication that the battery is being charged. Emergency Mode – The A.C. power fails. The I-320 senses the A.C. power failure and automatically switches to the Emergency Mode. One lamp is illuminated, at reduced output, for a minimum of 90 minutes. When the A.C. power is restored, the I-320 switches the system back to the Normal Mode and resumes battery charging. See page 1 of the Instruction Manual. TESTING & MAINTENANCE Pressing and holding the TBTS for a minimum of five seconds turns off the light on the TBTS and forces the unit into emergency mode, interrupting power to the designated A.C. ballast. The emergency lamp is now being lit by the I-320 unit. After releasing the TBTS, the fixture returns to normal operation after a momentary delay. To simulate a “BLACK OUT” use the circuit breaker to turn off A.C. power. Initial Testing – Allow the unit to charge approximately 1 hour, then press and hold the TBTS for a minimum of five seconds to conduct a short discharge test. Allow a 24 hour charge before conducting a one hour test. The I-320 is a maintenance free unit, however, periodic inspection and testing is required. NFPA 101, Life Safety Code, outlines the following schedule: Monthly – Insure that the TBTS is illuminated. Conduct a 30 second discharge test by depressing the TBTS. One lamp should operate at reduced output. Annually – Insure that the TBTS is illuminated. Conduct a full 11/2 hour discharge test. The unit should operate as intended for the duration of the test. “Written records of testing shall be kept by the owner for inspection by the authority having jurisdiction.” SERVICING SHOULD BE PERFORMED BY QUALIFIED PERSONNEL. Consult Customer Service or visit www.iotaengineering.com for current warranty information. Page 3 TYPICAL WIRING DIAGRAMS For wiring diagrams of ballasts not shown, consult our Customer Service. Wiring and Troubleshooting Tips are available on-line at http://www.iotaengineering.com/wiringtips.pdf 1. ONE LAMP RAPID START BALLAST 5. ONE LAMP INSTANT START BALLAST ONE LAMP RAPID START BALLAST ONE LAMP INSTANT START BALLAST SWITCHED OR UNSWITCHED LINE SWITCHED OR UNSWITCHED LINE WHT/BLK BLUE LAMP TBTSTBTS / CHARGE INDICATOR FOR WIRING THE COMMON. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL. 3. TWO LAMP RAPID START BALLAST TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. RED RED I-320 EMERGENCY BALLAST UNIT CONNECTOR WHT/RED LAMP *LAMP ORG (277V) BLK (120V) WHT/BLK BLACK WHITE UNSWITCHED RED BLUE A.C. Ballast BLUE 6 BLUE BLUE BLUE/WHT RED/WHT RED YELLOW LAMP TBTS TBTS / CHARGE INDICATOR 5 USE EITHER WHT/BLK LEAD FOR WIRING THE COMMON. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL. RED RED BLUE BLUE/WHT RED/WHT RED YELLOW LAMP I-320 LAMP COMMON ORG (277V) BLK (120V) DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. 5 USE EITHER WHT/BLK LEAD FOR WIRING THE COMMON. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL. 8. FOUR LAMP INSTANT START BALLAST TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. DO NOT MATE CONNECTOR UNTIL FOUR LAMP INSTANT START BALLAST INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. 6 CONNECT BLU/WHT AND RED/WHT WIRES TOGETHER SWITCHED OR UNSWITCHED LINE 3LISB_E WHT/BLK BLACK WHITE UNSWITCHED YELLOW WHT/BLK YELLOW A.C. Ballast BLUE BLUE RED RED 6 BLUE BLUE/WHT RED/WHT RED YELLOW I-320 LAMP *LAMP TBTS TBTS / CHARGE INDICATOR ORG (277V) BLK (120V) UNSWITCHED WHT/BLK UNIT CONNECTOR LAMP 5 COMMON WHITE EMERGENCY BALLAST LAMP TBTSTBTS / CHARGE INDICATOR COMMON *AC / EMERGENCY SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL FOR PROPER INPUT CIRCUIT WIRING. LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS 5 COMMON WHITE EMERGENCY BALLAST UNIT CONNECTOR *LAMP SWITCHED OR 2LRSB_E_4 UNSWITCHED LINE SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL FOR PROPER INPUT CIRCUIT WIRING. VIOLET BLUE/WHT BLUE/WHT VIOLET A.C. Ballast RED OR RED/BLK (+) BLACK WHITE BLUE BLUE YELLOW YELLOW WHT/BLK WHT/RED THREE LAMP START BALLAST DO NOT MATERAPID CONNECTOR UNTIL TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. VIOLET LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS 4. THREE LAMP RAPID START BALLAST INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. UNSWITCHED *AC / EMERGENCY WHT/RED SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL FOR PROPER INPUT CIRCUIT WIRING. COMMON WHITE ORG (277V) BLK (120V) WHT/BLK TBTSTBTS / CHARGE INDICATOR COMMON *AC / EMERGENCY SWITCHED 2LISB_2_EOR UNSWITCHED LINE I-320 *LAMP COMMON RED/WHT WIRES TOGETHER EMERGENCY BALLAST UNIT CONNECTOR LAMP 6 CONNECT BLU/WHT AND WHT/BLK VIOLET A.C. Ballast 5 COMMON WHITE FOR WIRING THE COMMON. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL. TEST ACCESSORY LEADSTHREE INSTANT START DO NOTLAMP MATE CONNECTOR UNTIL BALLASTREFER TO INSTALLATION INSTALLATION IS COMPLETE AND INSTRUCTIONS FOR PROPER AC POWER IS SUPPLIED. POLARITY WIRING. RED OR RED/BLK (+) YELLOW YELLOW BLUE BLUE/WHT RED/WHT RED YELLOW BLUE BLUE SWITCHED OR 2LRSB_E UNSWITCHED LINE 5 USE EITHER WHT/BLK LEAD LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS 7. THREE LAMP INSTANT START BALLAST VIOLET BLACK WHITE WHT/BLK RED OR RED/BLK (+) VIOLET DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL FOR PROPER INPUT CIRCUIT WIRING. VIOLET 5 USE EITHER WHT/BLK LEAD LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS TWO LAMP RAPID START BALLAST UNSWITCHED *AC / EMERGENCY RED OR RED/BLK (+) VIOLET SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL FOR PROPER INPUT CIRCUIT WIRING. 5 COMMON ORG (277V) BLK (120V) WHT/BLK TBTSTBTS / CHARGE INDICATOR COMMON COMMON *AC / EMERGENCY 6 CONNECT BLU/WHT AND SWITCHED RED/WHT WIRESOR TOGETHER UNSWITCHED LINE WHT/BLK 1LISB_E WHITE I-320 EMERGENCY BALLAST UNIT CONNECTOR *LAMP FOR WIRING THE COMMON. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL. VIOLET RED BLUE BLUE/WHT RED/WHT RED YELLOW 6 VIOLET UNSWITCHED BLUE A.C. Ballast RED OR RED/BLK (+) ORG (277V) BLK (120V) WHT/BLK TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. BLACK WHITE 5 COMMON WHITE I-320 EMERGENCY BALLAST UNIT CONNECTOR *LAMP 1LRSB_E 5 USE EITHER WHT/BLK LEAD LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS WHT/RED LAMP SWITCHED OR UNSWITCHED LINE SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OFLAMP INSTALLATION MANUAL PROPER TWO INSTANT STARTFOR BALLAST INPUT CIRCUIT WIRING. 6. TWO LAMP INSTANT START BALLAST VIOLET BLUE BLUE/WHT RED/WHT RED YELLOW RED RED / CHARGE TBTSTBTS INDICATOR WHT/RED FOR WIRING THE COMMON. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL. VIOLET BLUE BLUE WHT/RED YELLOW YELLOW A.C. Ballast VIOLET VIOLET 5 USE EITHER WHT/BLK LEAD WHT/BLK RED OR RED/BLK (+) BLACK WHITE UNSWITCHED WHT/BLK COMMON TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. ORG (277V) BLK (120V) *AC / EMERGENCY LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS INPUT CIRCUIT WIRING. 5 COMMON WHITE I-320 EMERGENCY BALLAST UNIT CONNECTOR *LAMP 2. TWO LAMP RAPID START BALLAST TWO LAMP RAPIDMANUAL STARTFOR BALLAST OF INSTALLATION PROPER 6 VIOLET RED BLUE BLUE/WHT RED/WHT RED YELLOW BLUE A.C. Ballast WHT/RED WHITE WHT/BLK RED OR RED/BLK (+) BLACK UNSWITCHED TBTSTBTS / CHARGE INDICATOR COMMON *AC / EMERGENCY SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 ORG (277V) BLK (120V) WHT/BLK UNIT CONNECTOR *LAMP 5 COMMON WHITE I-320 EMERGENCY BALLAST VIOLET A.C. Ballast RED OR RED/BLK (+) RED RED BLUE BLUE/WHT RED/WHT RED YELLOW BLUE BLUE WHT/RED BLACK WHITE *AC / EMERGENCY LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. 5 USE EITHER WHT/BLK LEAD FOR WIRING THE COMMON. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL. SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL FOR PROPER INPUT CIRCUIT WIRING. DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. 5 USE EITHER WHT/BLK LEAD FOR WIRING THE COMMON. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL. 6 CONNECT BLU/WHT AND RED/WHT WIRES TOGETHER 4LISB_E 3LRSB_E SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL FOR PROPER INPUT CIRCUIT WIRING. DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. Rev. 1506 68322-061 LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. Page 4 5 USE EITHER WHT/BLK LEAD FOR WIRING THE COMMON. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL. 6 CONNECT BLU/WHT AND RED/WHT WIRES TOGETHER ADDITIONAL WIRING DIAGRAMS For wiring diagrams of ballasts not shown, consult our Customer Service. Wiring and Troubleshooting Tips are available on-line at http://www.iotaengineering.com/wiringtips.pdf THREE LAMP RAPID START BALLAST 1. THREE LAMP RAPID START BALLAST SWITCHED OR UNSWITCHED LINE WHT/BLK RED RED ORANGE ORANGE YELLOW YELLOW BROWN BROWN BLUE BLUE/WHT RED/WHT RED YELLOW 5 COMMON WHITE I-320 EMERGENCY BALLAST ORG (277V) BLK (120V) UNSWITCHED WHT/BLK UNIT CONNECTOR LAMP VIOLET BLUE BLUE BLU/WHT BLU/WHT A.C. Ballast WHT/RED WHITE RED OR RED/BLK (+) VIOLET BLACK LAMP TBTS / CHARGE TBTS INDICATOR *LAMP COMMON *AC / EMERGENCY SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 THREE LAMP RAPID START BALLAST OF INSTALLATION MANUAL FOR PROPER INPUT CIRCUIT WIRING. 5 USE EITHER WHT/BLK LEAD LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS FOR WIRING THE COMMON. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL. 2. THREE LAMP RAPID START BALLAST BLUE BLUE/WHT RED/WHT RED YELLOW SWITCHED OR UNSWITCHED LINE WHT/BLK 3_LRSB_E_3 5 COMMON WHITE I-320 EMERGENCY BALLAST ORG (277V) BLK (120V) UNSWITCHED WHT/BLK UNIT CONNECTOR LAMP VIOLET A.C. Ballast BLU/WHT BLU/WHT BLUE BLUE BROWN BROWN ORANGE ORANGE YELLOW YELLOW RED RED WHT/RED BLACK WHITE TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. RED OR RED/BLK (+) VIOLET DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. LAMP TBTS / CHARGE TBTS INDICATOR *LAMP COMMON *AC / EMERGENCY 5 USE EITHER WHT/BLK LEAD SELECT PROPER VOLTAGE LAMP SELECTOR LEADS—REFER LEAD. CAP UNUSED LEAD. REFER TO TO INSTALLATION INSTRUCTIONS, AC INPUT WIRING ON ILLUSTRATION 3 LAMPS OPERATION SECTION FOR OF INSTALLATION MANUAL FOR PROPER FOUR LAMP RAPID START BALLAST VARIOUS OPTIONS INPUT CIRCUIT WIRING. TEST ACCESSORY LEADSDO NOT MATE CONNECTOR UNTIL REFER TO INSTALLATION INSTALLATION IS COMPLETE AND INSTRUCTIONS FOR PROPER AC POWER IS SUPPLIED. POLARITY WIRING. FOR WIRING THE COMMON. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL. 3. FOUR LAMP RAPID START BALLAST I-320 LAMP VIOLET EMERGENCY BALLAST ➁ UNIT CONNECTOR LAMP SWITCHED OR 3_LRSB_E_HE UNSWITCHED WHT/BLK WHITE ORG (277V) BLK (120V) WHT/BLK *AC / EMERGENCY SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL FOR PROPER FOUR LAMP RAPID START BALLAST INPUT CIRCUIT WIRING. ➂ COMMON TBTSTBTS / CHARGE INDICATOR 5 USE EITHER WHT/BLK LEAD LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS FOR WIRING THE COMMON. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL. 4. FOUR LAMP RAPID START BALLAST LAMP BLUE BLUE/WHT RED/WHT RED YELLOW EMERGENCY I-320 BALLAST WHITE ORG (277V) BLK (120V) 5 COMMON 4LRSB_E_2 UNSWITCHED WHT/BLK UNIT CONNECTOR LAMP VIOLET A.C. Ballast SWITCHED OR UNSWITCHED LINE WHT/BLK RED OR RED/BLK (+) VIOLET BLU/WHT BLU/WHT ORG ORG YELLOW YELLOW BROWN BROWN BLUE BLUE RED RED TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. WHT/RED DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. WHITE UNSWITCHED ➃ *LAMP BLACK LINE 5 COMMON VIOLET LAMP BLUE BLUE/WHT RED/WHT RED YELLOW RED OR RED/BLK (+) A.C. Ballast RED RED BLUE/WHT BLUE/WHT BLUE BLUE WHT/RED BLACK WHITE YELLOW YELLOW BROWN BROWN LAMP TBTSTBTS / CHARGE INDICATOR *LAMP COMMON *AC / EMERGENCY SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL FOR PROPER INPUT CIRCUIT WIRING. LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS 5 USE EITHER WHT/BLK LEAD FOR WIRING THE COMMON. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL. TEST ACCESSORY LEADS-SELECTOR LEADS—REFER SELECT PROPERDOVOLTAGE LAMP NOT MATE CONNECTOR UNTIL REFER TO INSTALLATION INSTALLATION IS COMPLETE AND TO INSTRUCTIONS FOR INSTALLATION PROPER LEAD. CAP UNUSED LEAD. REFER TO INSTRUCTIONS, AC POWER IS SUPPLIED. POLARITY WIRING. AC INPUT WIRING ON ILLUSTRATION 3 4LRSB_E_4 FOR LAMPS OPERATION SECTION OF INSTALLATION MANUAL FOR PROPER VARIOUS OPTIONS INPUT CIRCUIT WIRING. TEST ACCESSORY LEADSDO NOT MATE CONNECTOR UNTIL REFER TO INSTALLATION INSTALLATION IS COMPLETE AND INSTRUCTIONS FOR PROPER AC POWER IS SUPPLIED. POLARITY WIRING. Rev. 1506 68322-061 Page 5 Insert 5 USE EITHER WHT/BLK LEAD FOR WIRING THE COMMON. REFER TO AC INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL. 6 CONNECT BLU/WHT AND RED/WHT WIRES TOGETHER