st i l a i c e p S g lin d n a rH i A l a tri s u d d In n a OEM HP SERIES I HIGH PRESSURE BLOWERS 7697 Snider Road, Mason, OH 45040-9135 Telephone: 513-573-0600 Visit us at www.cincinnatifan.com for more information. Cat. No. HP-I-107 Supersedes HP-1-803 ct u d o r P Its d n i h e sB d n a t S t a h T y n a A Comp Cincinnati Fan can provide: • Technical evaluation for correct performance conditions. • Review of air stream and ambient conditions that require special attention. • Selection of proper components to meet required design specifications. • Selection of proper accessories. • System analysis for proper fan design. Since the founding of Cincinnati Fan in 1956, the company’s mission has been to provide quality products at competitive prices, backed by dependable service. This mission is carried out by specializing in the market for industrial air handling products up to 125 HP. But specialization does not mean the product line is small. Cincinnati Fan offers a wide variety of standard and customized products, production flexibility, and customer responsiveness. Cincinnati Fan operates in a modern facility specifically designed for world class manufacturing enabling us to build standard products to order, including accessories, and ship within 10 working days. Cincinnati Fan has over 170 experienced sales engineers across the U.S. and Canada ready to serve your air handling needs. With support like this, you can be sure your Cincinnati Fan product will be well-built and will provide maximum dependability and longevity. Visit us at www.cincinnatifan.com for more information. SPECIFICATIONS FOR HP SERIES I BLOWERS Radial bladed pressure blowers shall be Cincinnati Fan HP, Series I, Model ______, Arrangement __________ Capacity: __________ CFM, __________ Static Pressure at standard conditions. Operating conditions: __________°F, __________Ft. Altitude. Wheels shall be 319 cast aluminum with integral cast hub and blades. Wheels shall be dynamically balanced to assure smooth operation. Fan motor and bearing vibration levels shall not exceed 1.5 mils displacement at 3450 RPM. Shafts shall be turned, ground and polished steel (or stainless steel). All fan shafts shall receive a rust preventive coating prior to shipment. All fans shall be test run at factory before shipping. Construction gauges shall be as shown in Cincinnati Fan’s HP, Series I catalog. The blower housing shall be continuously welded and supported to prevent pulsation at all conditions. Fan bearings shall be greaselubricated, heavy-duty, self-aligning ball bearings mounted in cast iron pillow blocks. V-belt drives shall be selected for a minimum of 1.3 times nominal horsepower. All parts in contact with airstream shall be standard steel, aluminum or stainless steel as specified. Before painting, steel parts shall be cleaned by detergent wash, phosphatized and painted with oven cured gray enamel. The following accessories shall be included: (See page 4 for available accessories). 2 THREE STANDARD ARRANGEMENTS ARRANGEMENT 1 (V-BELT DRIVE) • Motor not mounted on bearing base. • Turned, ground and polished shafting assures smooth operation. A rust preventive coating is applied prior to shipment. • Heavy-duty, self-aligning ball bearings in relubricatable cast-iron pillow blocks. Bearings are selected for optimal performance. • Maximum temperature of standard design: 200°F; high temperature design up to 400°F. ARRANGEMENT 4 (DIRECT DRIVE) • Motor mounted on motor base. • Wheel mounted on motor shaft. • Maximum temperature of standard design: 200°F; high temperature design not available. ARRANGEMENT 9 (V-BELT DRIVE) • Motor mounted on an adjustable slide base on the side of the bearing base. • Turned, ground and polished shafting assures smooth operation. A rust preventive coating is applied prior to shipment. • Heavy-duty, self-aligning ball bearings in relubricatable cast-iron pillow blocks. Bearings are selected for optimal performance. • Maximum temperature of standard design: 200°F; high temperature design up to 400°F. 3 STANDARD FEATURES FOR ALL HP’s Discharge Flange Standard ANSI-125/ASA-150 pound hole pattern furnished. See pages 10 or 11 for dimensions. Teflon Shaft Seal Belt Guard Motor Slide Base (Arrangement 9 only) Painted safety yellow. (Arrangement 9 only) Cast Aluminum Wheel (Non-Sparking) + PLUS + • Fan shafts receive a rust preventative coating prior to shipment. • Arrangement #1 fans offer easy field conversion to arrangement #9 by the addition of a motor slide base. • Bearings are relubricatable, cast iron, pillow blocks sized for 150,000 hours average life under normal operating conditions. (Excessive belt tension will shorten bearing life). • Continuously welded fan housings with removable inlet and drive side plates. • Blower housings are reversible and rotatable in 45° increments. • All fans receive a mechanical run test to assure proper balance and alignment before shipping. Arrangements #1 and #9 (less motor) have driveend key furnished. OPTIONAL ACCESSORIES Shaft Guard Shaft guard available on arrangement 1 and 9. Covers bearings and shaft between fan housing and belt guard. Painted safety yellow. Inlet Filter Drain Connection ⁄4" pipe coupling welded to lowest point of housing. Wire mesh or paper cartridge available. 3 4 Inlet Flange Standard ANSI-125/ASA-150 pound hole pattern furnished. See page 10 for dimensions. SPARK-RESISTANT CONSTRUCTION Type A: All parts in contact with airstream are of nonferrous material. Consult factory. Type B: The standard wheels are cast aluminum. With the addition of an aluminum ring around the housing shaft opening, the fan will be AMCA type “B” spark resistant. Maximum Temperature 200°F. ! WARNING The use of aluminum or aluminum alloys in the presence of steel which has been allowed to rust requires special consideration. Research by the U.S. Bureau of Mines and others has shown that aluminum impellers rubbing on rusty steel may cause high intensity sparking. The use of the above Standard in no way implies a guarantee of safety for any level of spark resistance. Spark resistant construction also does not protect against ignition of explosive gases caused by catastrophic failure or from any airstream material that may be present in a system. TEMPERATURE - ALTITUDE CONVERSIONS Standard Construction: All arrangements suitable to 200°F. 201°- 300°F. Construction: Standard fan with steel wheel. Arrangements 1 and 9 only. 301°- 400°F. Construction: Standard fan with steel wheel, heat slinger and slinger guard. Arrangements 1 and 9 only. Fan performance tables are developed using standard air which is 70°F., 29.92" barometric pressure and .075 lbs. per cubic foot. Density changes resulting from temperature or barometric pressure variations (such as high altitudes) must be corrected to standard conditions before selecting a fan based on standard performance data. Temperature and/or altitude conversion factors are used in making corrections to standard conditions. TEMPERATURE - ALTITUDE CONVERSION FACTORS AIR TEMP DEG. F. 0˚ 40˚ 70˚ 80˚ 100˚ 120˚ 140˚ 160˚ 180˚ 200˚ EXAMPLE: ALTITUDE IN FEET ABOVE SEA LEVEL 0 .87 .94 1.00 1.02 1.06 1.09 1.13 1.17 1.21 1.25 1000 2000 .91 .94 .98 1.02 1.04 1.08 1.06 1.10 1.10 1.14 1.14 1.18 1.18 1.22 1.22 1.26 1.26 1.30 1.29 1.34 3000 4000 .98 1.01 1.06 1.10 1.12 1.16 1.14 1.19 1.19 1.23 1.23 1.28 1.27 1.32 1.31 1.36 1.36 1.41 1.40 1.45 5000 1.05 1.14 1.20 1.23 1.28 1.32 1.37 1.42 1.46 1.51 6000 1.09 1.19 1.25 1.28 1.33 1.38 1.42 1.47 1.52 1.57 7000 1.13 1.23 1.30 1.33 1.38 1.43 1.48 1.53 1.58 1.63 8000 1.17 1.28 1.35 1.38 1.43 1.48 1.54 1.59 1.64 1.69 9000 10000 1.22 1.26 1.32 1.36 1.40 1.45 1.43 1.48 1.48 1.54 1.53 1.58 1.58 1.65 1.64 1.70 1.70 1.75 1.75 1.81 Select a belt driven HPE to deliver 500 CFM at 18" SP at 160°F., and 7000’ altitude. STEP 1. From the table, conversion factor is 1.53. STEP 2. Correct static pressure is: 1.53 x 18" SP = 27.5" SP at standard conditions. STEP 3. Check HP catalog for 500 CFM at 27.5" SP. We select a belt driven HPE and interpolation gives 3463 RPM and 5.61 BHP. STEP 4. Correct the BHP for the lighter air: 5.61 ÷ 1.53 = 3.67 BHP. A 5 HP motor will suffice at 160° F., and 7000' but not at standard conditions. Special motor insulation may be required above 3500 feet altitude. Consult factory. SUCTION PRESSURE CORRECTIONS Rarefication: When air is pulled into a blower inlet (negative pressure) the air molecules are “stretched out”, or rarefied, and become less dense than at the blower discharge where the air is compressed. Catalog ratings may be used directly, without correction, for static pressures defined at the fan discharge. For static pressures defined at the fan inlet (i.e., negative pressures), a correction is typically only made for inlet suction pressures greater than 15" W.G. The table at the right gives corrected static pressures for suction pressure (rarefication). These corrected static pressures are for standard air (70˚F., 29.92" Hg barometric pressure and .075 lbs. per cubic foot density) at the blower inlet. If the inlet air temperature and/or altitude are different, make those corrections as shown above and then correct for rarefication. 5 Suction Pressure in Inches W.G. 16 18 20 22 24 26 28 30 Corrected Static Pressure 16.7 18.8 21.0 23.3 25.5 27.8 30.1 32.4 DIRECT DRIVE RATINGS @ 3450 RPM CFM and BHP at Static Pressure Shown • Ratings at 70˚F., .075 Density, Sea Level Performance shown is for fans with inlet and outlet ducts Model HPA SP in inches W.G. 8 11" Dia. Whe 6 3/4 HP el 10" Dia. See PB C atalo g Wheel 4 1/3 HP 2 1/2 HP 60 See PB Catalog 120 180 Model HPB CFM 240 300 360 MAXIMUM MOTOR FRAME: 145T OUTLET AREA: .063 SQ. FT. INLET AREA: .120 SQ. FT. 1 HP 1-1/2 HP 12 SP in inches W.G. MAXIMUM MOTOR FRAME: 143T OUTLET AREA: .063 SQ. FT. INLET AREA: .120 SQ. FT. 14" Dia. W heel 10 12" Dia 8 6 . Wheel 1/2 HP 3/4 HP See PB Ca ta log 4 75 150 225 CFM 300 375 OUTLET AREA: .063 SQ. FT. INLET AREA: .120 SQ. FT. Model HPC 450 MAXIMUM MOTOR FRAME: 184T 20 2 HP 3 HP 17" Dia. W heel SP in inches W.G. 15 15" D ia. Wh eel 10 1 HP Se 1-1/2 HP eP B Ca tal 5 150 300 450 CFM 6 600 og 750 900 DIRECT DRIVE RATINGS @ 3450 RPM CFM and BHP at Static Pressure Shown • Ratings at 70˚F., .075 Density, Sea Level Performance shown is for fans with inlet and outlet ducts Model HPD OUTLET AREA: .063 SQ. FT. INLET AREA: .120 SQ. FT. 18.5" Dia. Whe MAXIMUM MOTOR FRAME: 184T 5 HP el SP in inches W.G. 20 17" Dia .W hee l 15 Se e 1-1/2 HP 2 HP PB 3 HP Ca ta Se e 10 PB lo g Ca t alo g 5 150 300 450 600 750 900 1050 CFM Model HPE 5 HP OUTLET AREA: .063 SQ. FT. INLET AREA: .120 SQ. FT. 7-1/2 HP 30 SP in inches W.G. MAXIMUM MOTOR FRAME: 215T 22" D ia. Wh 20" D ia. W h eel eel 20 3 HP Se eP BC ata log 10 200 400 600 CFM 800 7 1000 BELT DRIVE RATING TABLES CFM and BHP at Static Pressure Shown • Ratings at 70˚F., .075 Density, Sea Level WHEEL DIA. 11.00" Model HPA CFM 100 150 200 250 300 350 1" SP RPM 2" SP BHP RPM 3" SP BHP 1922 2202 2485 2039 .15 2251 .25 2526 .38 2815 .14 .22 .34 .49 2777 .55 3094 .68 RPM 4" SP BHP 2293 2390 2557 2784 3059 .15 .21 .29 .43 .60 1" SP RPM 100 150 200 250 300 1461 1674 1893 350 400 450 500 550 2120 2353 2591 2833 2879 CFM 100 150 200 250 300 2" SP BHP .46 .64 .87 1.16 1.30 3331 3369 3409 3495 3596 BHP .68 .81 .95 1.15 1.37 3" SP BHP 1582 .13 1741 .21 1933 .31 2138 11" SP RPM RPM .13 .19 .28 .41 RPM 12" SP BHP 1" SP RPM 100 200 300 400 500 1237 1508 1797 600 700 800 2095 2399 2708 CFM RPM 1270 .18 1459 .36 1690 .63 1949 1775 1863 1984 2152 2343 .13 .19 .26 .36 .50 6" SP BHP 2928 2995 3105 3266 .26 .37 .46 .59 RPM RPM 5" SP BHP 2038 2106 2210 2350 2527 .19 .25 .33 .44 .59 RPM 3200 3255 3346 3500 RPM 8" SP BHP .33 3449 .45 3500 .55 3586 .70 RPM BHP .41 3682 .52 3728 .67 .49 .60 OUTLET AREA .063 SQ. FT. 6" SP BHP 2270 2324 2419 2536 2693 7" SP BHP RPM .25 .32 .42 .53 .68 2480 2522 2609 2718 2858 .78 2881 .89 1.02 3075 1.14 1.31 3030 3219 7" SP BHP .31 .39 .50 .63 .79 RPM 1.00 3169 1.27 3355 8" SP BHP 2673 2709 2789 2892 3013 INLET AREA .120 SQ.FT. .38 .46 .59 .73 .89 RPM BHP 9" SP RPM BHP 2852 .45 2889 .54 2957 .67 3054 .83 3164 1.00 3020 .52 3057 .63 3116 .76 3206 .94 3315 1.12 1.10 3312 1.23 1.39 3447 1.35 10" SP RPM BHP 3180 .60 3217 .72 3266 .85 3352 1.05 3459 1.25 13" SP RPM BHP WHEEL DIA. 17.00" 3" SP BHP .14 .26 .45 .75 RPM 1440 1501 1643 1855 2095 4" SP BHP .13 .20 .33 .55 .87 1.02 2231 1.17 2353 1.31 1.56 2522 1.74 2633 1.91 2.27 2818 2.47 2920 2.67 11" SP RPM INLET AREA .120 SQ.FT. 3476 .76 3615 .85 3514 .91 3653 1.00 3549 1.05 3688 1.15 3631 1.26 3761 1.37 3727 1.50 3853 1.63 2" SP BHP .20 .29 .37 .51 .70 4" SP BHP Model HPC CFM 2628 2709 2845 3035 3275 2352 .57 2545 .68 2720 2569 .78 2758 .90 2922 2793 1.03 2972 1.17 3134 3022 1.33 3192 1.49 RPM 5" SP BHP WHEEL DIA. 14.00" Model HPB CFM RPM OUTLET AREA .063 SQ. FT. 12" SP 13" SP RPM 1661 1697 1823 2011 2228 5" SP BHP .18 .27 .43 .66 .99 RPM OUTLET AREA .063 SQ. FT. 6" SP BHP RPM BHP 7" SP RPM 1855 .24 1871 .34 1987 .52 2147 .75 2360 1.12 2031 2047 2144 2285 2485 .31 .43 .61 .87 1.26 2474 1.46 2591 1.60 2737 2.07 2837 2.24 3017 2.86 2699 2945 1.74 2811 2.41 3041 14" SP 15" SP 16" SP 2192 2208 2287 2416 2597 BHP .38 .51 .71 .99 1.38 INLET AREA .120 SQ.FT. 8" SP RPM BHP 9" SP RPM BHP 2484 .53 2618 .61 2499 .70 2633 .80 2545 .90 2661 1.01 2663 1.25 2782 1.37 2814 1.64 2923 1.80 1.91 2917 2.07 2.58 3133 2.74 3016 2.22 3109 2.36 3229 2.93 17" SP 18" SP 19" SP BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 100 200 300 400 500 2745 2760 2776 2895 3027 .70 .90 1.12 1.50 1.95 2866 2881 2897 3003 3126 .78 1.00 1.25 1.62 2.11 2983 2998 3013 3107 3224 .87 1.11 1.37 1.75 2.27 3095 3110 3126 3207 3324 .97 1.22 1.50 1.87 2.43 3203 3218 3234 3303 3419 1.07 1.33 1.63 2.00 2.58 3308 3322 3338 3394 3512 1.17 1.45 1.77 2.14 2.74 3409 3424 3439 3481 3602 1.27 1.57 1.90 2.28 2.89 3507 3522 3538 3566 1.37 1.69 2.04 2.42 3603 3618 3633 3649 1.48 1.81 2.18 2.57 600 3199 2.51 3287 2.65 3382 2.84 8 BHP 2343 .45 2359 .61 2421 .80 2539 1.12 2703 1.49 RPM Performance shown is for fans with inlet and outlet ducts. BHP does not include drive losses 10" SP RPM BELT DRIVE RATING TABLES CFM and BHP at Static Pressure Shown • Ratings at 70˚F., .075 Density, Sea Level WHEEL DIA. 18.50" Model HPD CFM 4" SP RPM 5" SP BHP BHP BHP 1501 1531 1645 1804 1986 600 700 800 2189 1.29 2299 1.44 2409 1.59 2451 1.90 2513 1.98 2604 2.14 2759 2.81 2793 2.83 2828 2.85 14" SP RPM BHP 1676 .22 1702 .33 1789 .49 1935 .72 2112 1.04 6" SP RPM 100 200 300 400 500 CFM .16 .26 .40 .61 .90 RPM 1835 .28 1859 .40 1926 .58 2063 .83 2227 1.17 15" SP 16" SP 2477 .63 2498 .82 2525 1.07 2600 1.42 2732 1.85 2586 .71 2691 .78 2607 .91 2711 1.00 2634 1.19 2738 1.30 2700 1.54 2795 1.67 2820 2.00 2905 2.14 2514 1.76 2613 1.92 2701 2.32 2795 2.50 2909 3.04 2989 3.22 2705 2886 3075 2.07 2793 2.69 2974 3.43 3158 2.21 2880 2.37 2.88 3058 3.07 3.63 3238 3.85 2969 2.54 3053 2.71 3137 3.24 3213 3.41 3318 4.07 3394 4.29 2983 3003 3029 3063 3157 1.05 1.30 1.65 2.04 2.59 3075 3095 3120 3147 3236 5" SP RPM BHP BHP 18" SP 19" SP BHP RPM 3163 3183 3208 3235 3316 1.24 1.52 1.89 2.32 2.90 3249 3269 3294 3321 3394 1.33 1.63 2.02 2.46 3.05 3364 3.41 3436 3.58 3513 4.17 3585 4.37 3508 3654 3.76 3580 4.57 3723 1.14 1.41 1.77 2.17 2.74 6" SP RPM BHP 7" SP RPM BHP 8" SP RPM BHP 20" SP RPM WHEEL DIA. 22.00" Model HPE BHP .55 .73 .96 1.30 1.71 .96 1.19 1.38 1.92 2.44 2.89 3215 3.06 3290 3.23 3.58 3336 3.77 3439 3.97 4.51 3539 4.71 3607 4.91 4" SP 2363 2385 2412 2502 2640 2889 2909 2935 2977 3076 3136 3287 3469 RPM .48 .64 .86 1.18 1.57 17" SP 3333 3353 3377 3404 3471 BHP 1.43 1.74 2.14 2.61 3.21 21" SP RPM BHP 22" SP BHP RPM BHP 23" SP BHP RPM BHP RPM BHP 3415 3435 3459 3485 3546 1.53 1.86 2.27 2.76 3.36 3495 3515 3538 3565 3619 1.64 1.98 2.40 2.91 3.52 3573 3593 3616 3643 3690 1.74 2.10 2.53 3.06 3.68 3.93 3650 4.11 4.78 3789 4.98 10" SP RPM BHP RPM 3719 4.29 3786 4.47 OUTLET AREA .063 SQ. FT. 9" SP BHP RPM RPM 13" SP 2242 2265 2297 2398 2542 RPM BHP 12" SP 2115 .41 2139 .56 2181 .77 2291 1.06 2439 1.42 BHP 600 700 800 11" SP RPM 1980 .34 2003 .48 2057 .67 2181 .95 2333 1.29 BHP 10" SP BHP RPM .87 1.09 1.42 1.79 2.29 9" SP RPM BHP 2792 2812 2839 2888 2993 8" SP BHP BHP RPM INLET AREA .120 SQ.FT. RPM RPM 100 200 300 400 500 CFM 7" SP RPM OUTLET AREA .063 SQ. FT. INLET AREA .120 SQ.FT. 11" SP 12" SP 13" SP RPM BHP RPM BHP RPM BHP 100 200 300 400 500 1262 1331 1463 1623 1799 .20 .33 .53 .82 1.20 1405 .26 1462 .41 1582 .64 1738 .96 1904 1.38 1537 .33 1588 .50 1695 .75 1843 1.10 2005 1.55 1660 .41 1775 .49 1707 .60 1817 .70 1802 .86 1903 .98 1941 1.24 2033 1.38 2099 1.73 2188 1.90 1883 1921 1997 2119 2273 .57 .80 1.10 1.52 2.08 1985 2019 2087 2203 2353 .66 .91 1.22 1.67 2.25 2083 2112 2172 2288 2431 .75 1.01 1.35 1.82 2.43 2176 2201 2256 2368 2505 .84 1.13 1.48 1.98 2.61 2265 2287 2341 2446 2576 .94 1.24 1.62 2.13 2.78 600 700 800 900 1000 1989 2191 2399 2614 2835 1.72 2.40 3.26 4.32 5.60 2088 2282 2485 2694 2909 2181 2369 2566 2771 2981 2268 2452 2644 2845 3051 2.54 3.34 4.31 5.50 6.94 2435 2608 2792 2984 3184 2.76 3.58 4.58 5.79 7.26 2513 2680 2863 3051 3247 2.97 3.82 4.86 6.09 7.58 2588 2753 2930 3116 3309 3.18 4.07 5.14 6.41 7.90 2660 2823 2996 3180 3369 3.39 4.31 5.41 6.72 8.24 2730 2891 3059 3242 3429 3.60 4.56 5.69 7.03 8.59 1100 1200 3059 3289 7.14 3130 7.52 3197 7.89 8.97 3353 9.37 3417 9.78 3262 8.26 3327 8.62 3389 8.99 3450 CFM 14" SP 1.92 2.62 3.52 4.62 5.94 15" SP 2.13 2.85 3.78 4.91 6.28 16" SP 2.34 3.10 4.04 5.21 6.61 17" SP 2353 2532 2719 2916 3119 18" SP 19" SP 9.35 3509 9.70 20" SP 21" SP 22" SP 23" SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 100 200 300 400 500 2350 2369 2423 2521 2645 1.04 1.36 1.76 2.29 2.96 2433 2448 2503 2593 2711 1.14 1.48 1.90 2.45 3.14 2513 2525 2579 2663 2780 1.24 1.60 2.05 2.61 3.33 2591 2599 2654 2731 2847 1.35 1.72 2.20 2.77 3.52 2666 2671 2726 2797 2913 1.46 1.85 2.35 2.94 3.72 2739 2742 2796 2861 2976 1.57 1.97 2.50 3.10 3.91 2810 2810 2864 2924 3038 1.69 2.10 2.66 3.27 4.11 2880 2877 2931 2986 3099 1.81 2.24 2.82 3.44 4.30 2948 2942 2996 3051 3158 1.93 2.37 2.98 3.62 4.50 3014 3008 3060 3115 3216 2.05 2.51 3.14 3.81 4.70 600 700 800 900 1000 2798 2957 3123 3301 3487 3.81 4.81 5.97 7.34 8.93 2863 3021 3185 3360 3544 4.02 5.05 6.25 7.65 9.28 2927 3083 3246 3417 3599 4.23 5.30 6.53 7.96 9.62 2989 3144 3306 3472 3653 4.45 5.55 6.81 8.27 9.97 3049 3203 3364 3529 4.66 5.79 7.10 8.59 3107 3261 3420 3584 4.87 6.04 7.38 8.91 3165 3317 3475 3639 5.09 6.29 7.66 9.22 3221 3373 3529 3692 5.30 6.53 7.94 9.54 3276 3427 3582 3744 5.52 3334 5.75 6.78 3479 7.03 8.22 3634 8.51 9.86 CFM 24" SP RPM BHP 25" SP 26" SP 27" SP RPM BHP RPM BHP RPM 3143 3137 3183 3238 3329 2.30 2.80 3.46 4.19 5.10 3205 3199 3243 3298 3383 2.43 2.95 3.63 4.38 5.30 3266 3260 3302 3356 3437 100 200 300 400 500 3079 3073 3122 3177 3273 2.17 2.66 3.30 4.00 4.90 600 700 800 3390 3531 3686 5.98 3445 6.21 3499 6.44 7.27 3582 7.52 3632 7.77 8.79 3736 9.07 3785 9.35 BHP 28" SP 29" SP RPM BHP RPM 3326 3320 3359 3414 3490 2.70 3.26 3.97 4.77 5.71 3386 3379 3416 3470 3541 2.83 3.41 4.14 4.97 5.92 3553 6.67 3605 6.91 3681 8.02 3730 8.27 3834 9.63 3881 9.91 3656 3777 7.14 8.52 2.56 3.10 3.80 4.58 5.51 9 BHP Performance shown is for fans with inlet and outlet ducts. BHP does not include drive losses DIMENSIONS and SPECIFICATIONS Arrangement #4, Direct Drive CW BH (Clockwise Bottom Horizontal) Discharge flange not available with Down Blast Discharge on Models HPA, HPB and HPC. Note: On some models motor may extend past end of motor base. DIMENSIONS IN INCHES ±1/8" MODEL HPA HPB HPC HPD HPE MOTOR FRAME 56-143T 56-145T 56-145T 182T-184T 56-184T 56-184T 213T-215T G H J M O V BB EE FF JJ 3 5⁄8 3 5⁄8 5 5 2 2 5 7⁄8 7 3⁄8 8 1⁄8 9 5⁄8 5 1⁄2 5 1⁄2 15 18 11 12 1⁄2 7 1⁄2 7 1⁄2 3 5⁄8 5 2 8 7⁄8 11 1⁄8 7 1⁄2 21 14 9 1⁄2 3 5⁄8 5 5 9 2 2 2 9 7⁄8 11 5⁄8 23 15 11 7⁄8 13 5⁄8 7 1⁄2 8 9 14 1⁄4 14 1⁄4 14 1⁄4 16 1⁄4 16 1⁄4 16 1⁄4 18 1⁄16 27 17 9 1⁄2 10 11 3 5⁄8 SHIP WT. LESS MTR. 60 70 90 93 123 140 150 H NOTE Discharge flange not available with downblast discharge on models HPA, HPB and HPC. INLET FLANGE DIMENSIONS FOR ALL HP’s ! DANGER HP MATERIAL GAUGES All fans & blowers shown have rotating parts and pinch points. Severe personal injury can result if operated without guards. Stay away from rotating equipment unless it is disconnected from its power source. Read operating instructions. 10 HOUSING INLET SIDE PLATE DRIVE SIDE PLATE BASE FLANGES 10 10 7 10 10 DIMENSIONS and SPECIFICATIONS Arrangement #1 and #9, Belt Drive (specify 9R or 9L) CW BH (Clockwise Bottom Horizontal) Discharge flange not available with Down Blast Discharge on Models HPA, HPB, HPC and HPD. Unit shown is arrangement 9R (motor on right side.) For motor on left side. specify arrangement 9L. DIMENSIONS IN INCHES ±1/8" MODEL MOTOR FRAME F G H J M O V Y Z BB EE FF JJ SHIP WT. LESS MTR. HPA 56-145T 3 3 3⁄16 11 1 3⁄8 5 7⁄8 8 1⁄8 12 5⁄16 1 1 ⁄4 22 5⁄16 15 14 13 13⁄16 105 HPB 56-145T 3 3 3 ⁄16 11 1 ⁄8 7 ⁄8 9 ⁄8 12 ⁄16 1 1 ⁄4 22 ⁄16 18 14 13 13⁄16 115 HPC 56-184T 3 3 3⁄16 11 1 3⁄8 8 7⁄8 11 1⁄8 12 5⁄16 1 1 ⁄4 22 5⁄16 21 14 13 13⁄16 135 HPD 56-215T 4 3 3 ⁄16 15 1 ⁄8 9 ⁄8 11 ⁄8 16 7 1 ⁄16 3 ⁄8 27 ⁄16 23 18 17 ⁄2 160 HPE 56-215T 4 3 3⁄16 15 1 3⁄8 11 7⁄8 13 5⁄8 16 1 7⁄16 3 ⁄8 27 5⁄16 27 18 17 1⁄2 170 3 3 3 7 5 5 5 5 5 1 CENTER DISTANCE MOTOR FRAME SIZE MODEL 56 143T-145T 182T-184T MIN. MAX. MIN. MAX. HPA 9 7⁄16 11 7⁄16 9 5⁄8 11 5⁄8 HPB 9 7⁄16 11 7⁄16 9 5⁄8 11 5⁄8 HPC 7 9 ⁄16 11 ⁄16 9 ⁄8 HPD 11 ⁄16 13 ⁄16 HPE 11 7⁄16 13 7⁄16 7 7 7 MIN. MAX. 11 5⁄8 10 11 3⁄4 11 ⁄16 13 ⁄8 13 ⁄16 11 7⁄16 13 3⁄8 13 3⁄16 5 7 3 3 H NOTE 213T-215T MIN. MAX. 15 1⁄8 13 3⁄16 16 15 1⁄8 13 13⁄16 16 Discharge flange not available with downblast discharge on models HPA, HPB, HPC and HPD. 8 DISCHARGE POSITIONS AVAILABLE Discharges shown are determined by viewing fan from motor or drive side. CW-TH Clockwise Top Horizontal Discharge CW-DB Clockwise Down-Blast Discharge CW-BH Clockwise Bottom Horizontal Discharge CW-UB Clockwise Up-Blast Discharge CCW-TH CounterClockwise Top Horizontal Discharge 11 CCW-DB CounterClockwise Down-Blast Discharge CCW-BH CounterClockwise Bottom Horizontal Discharge CCW-UB CounterClockwise Up-Blast Discharge