114rh rad hard quad precision op-amp

advertisement

MIL-PRF-38534 CERTIFIED

M.S.KENNEDY CORP.

4707 Dey Road Liverpool, N.Y. 13088

RAD HARD

QUAD PRECISION

OP-AMP

114RH

(315) 701-6751

FEATURES:

Manufactured using Space Qualified RH1013 Die

MIL-PRF-38535 Class V Processing & Screening

Total Dose Tested to TBD Krads(Si) (Method 1019.7 Condition A)

Single Supply Operation

Low Offset Voltage

Low Drift

Available in Straight or Gull Wing Lead Form

Contact MSK for MIL-PRF-38535 Qualification and Radiation Status

DESCRIPTION:

The MSK 114RH is a radiation hardened quad operational amplifier for use in space and severe military applications. This device offers low offset voltage, low drift, low offset current and high gain combined with a space efficient 14 pin surface mount flat pack. The MSK 114RH is an ideal solution when multiple precision amplifiers are required and board space is at a premium. The MSK 114RH 14 pin ceramic flat pack is offered with straight leads or gull wing for surface mount applications.

EQUIVALENT SCHEMATIC

TYPICAL APPLICATIONS

Battery Powered Precision Instrumentation

Multiple Limit Threshold Detection

Active Filters

Multiple Gain Blocks

Instrumentation Amplifiers

1

5

6

7

3

4

1

2

PIN-OUT INFORMATION

OUT A

-IN A

+IN A

+VCC

+IN B

-IN B

OUT B

14

13

12

11

10

9

8

OUT D

-IN D

+IN D

-VCC

+IN C

-IN C

OUT C

PRELIMINARY Rev. - 10/09

ABSOLUTE MAXIMUM RATINGS 7

±VCC

V

IN

Supply Voltage

Input Voltage

○ ○ ○

Differential Input Voltage

Equal to Positive Supply Voltage

5V Below Negative Supply Voltage

Output Short Circuit Duration

○ ○ ○ ○ ○ ○ ○

±22V

±30V

Indefinite

T

ST

T

LD

T

T

J

C

Storage Temperature Range

Lead Temperature Range

(10 Seconds)

○ ○ ○ ○ ○

Junction Temperature

○ ○ ○

-65°C to +150°C

300°C

150°C

Case Operating Temperature Range

MSK 114RH

MSK 114VRH

○ ○

○ ○

○ ○

-40°C to+85°C

-55°C to +125°C

ELECTRICAL SPECIFICATIONS

6

7

8

NOTES:

3

4

1

2

5

Unless otherwise specified; ±VCC=±15V

DC

, V

CM

=0V.

Devices shall be capable of meeting the parameter, but need to be tested. Typical parameters are for reference only.

Industrial grade devices shall be tested to subgroup 1 unless otherwise specified.

Military grade devices ('V' Suffix) shall be 100% tested to subgroups 1,2,3 and 4.

Subgroup 1, 4 T A =T C =+25°C

Subgroup 2, 5 T

A

=T

C

=+125°C

Subgroup 3, 6 T

A

=T

C

=-55°C

Refer to SMD TBD for electrical parameters for devices purchased as such.

Continuous operation at or above absolute maximum ratings may adversely effect the device performance and/or life cycle.

Pre and Post irradiation limits at 25°C, to TBD Krads TID, are identical unless otherwise specified.

PRELIMINARY Rev. - 10/09

2

APPLICATION NOTES

SINGLE SUPPLY OPERATION

The MSK 114RH may be used in single supply applications where the negative supply is 0 volts. The device incorporates unique phase reversal protection circuitry to avoid the most common problems occurring during single supply operation. The phase reversal protection circuitry, however does not function when one specific amplifier of the other three is driven hard into negative saturation at the output. Phase reversal protection does not work under the following conditions: Amplifier A and D when the opposite output is negative saturation. Amplifiers B and C outputs have no effect. Amplifier B or C when the opposite output is in negative saturation. Amplifiers

A and D outputs have no effect. The MSK 114RH all-NPN output stage maintains it's low output resistance and high gain characteristics until the output is saturated. In dual supply applications, the output stage will remain crossover distoration-free. The minimum single supply voltage for proper operation of the MSK 114RH is +5

Volts.

TOTAL DOSE RADIATION TEST

PERFORMANCE

Radiation performance curves for TID testing will be generated for all radiation testing performed by MS Kennedy. These curves show performance trends throughout the TID test process and will be located in the MSK 114RH radiation test report. The complete radiation test report will be available in the RAD HARD PRODUCTS section on the MSK website.

ADDITIONAL APPLICATION INFORMATION

For additional applications information, please reference Linear Technology Corporation's® LT1013/1014 and RH1014 data sheets.

FIGURE 1

FIGURE 2

3

PRELIMINARY Rev. - 10/09

TYPICAL PERFORMANCE CURVES

4

PRELIMINARY Rev. - 10/09

MECHANICAL SPECIFICATIONS

ESD TRIANGLE INDICATES PIN 1

WEIGHT=TBD

ORDERING INFORMATION

MSK114 V RH

LEAD CONFIGURATIONS

BLANK= STRAIGHT

RADIATION HARDENED

SCREENING

BLANK= INDUSTRIAL

V=MIL-PRF-38535 CLASS V

GENERAL PART NUMBER

The above example is a Class V device with straight leads.

5 PRELIMINARY Rev. - 10/09

ESD TRIANGLE INDICATES PIN 1

WEIGHT=TBD

ORDERING INFORMATION

MSK114 V RH G

LEAD CONFIGURATIONS

G=GULL WING

RADIATION HARDENED

SCREENING

BLANK= INDUSTRIAL

V=MIL-PRF-38535 CLASS V

GENERAL PART NUMBER

The above example is a Class V device with gull wing leads.

M.S. Kennedy Corp.

4707 Dey Road, Liverpool, New York 13088

Phone (315) 701-6751

FAX (315) 701-6752 www.mskennedy.com

The information contained herein is believed to be accurate at the time of printing. MSK reserves the right to make changes to its products or specifications without notice, however, and assumes no liability for the use of its products.

Please visit our website for the most recent revision of this datasheet.

Contact MSK for MIL-PRF-38535 Class V and radiation status.

6 PRELIMINARY Rev. - 10/09