D140 F [mm] E-190.5 E-190.5 E-219.5 E-219.5 E-239.5 E-239.5 E [mm] 298~368 368~638 327~397 397~667 347~417 417~687 ・Perform the anti-rust treatment to the metal section. T1HPX6 - T1HP80 D120 Group Handle types E-286 E-358 E-315 E-387 E-335 E-407 G [mm] - - - remarks The Handle Depth/ The Mounting Direction Changing Procedure 2G0467SAA (KRB KRBKRB-0444) 0444 7-2-10 Kamihigashi, Hiranoku, Osaka 547-0002, Japan TEL:81-6-6791-9323/ FAX:81-6-6791-9274 Web Site: www.terasaki.co.jp Email: int-sales@terasaki.co.jp Please retain this manual for future reference. The Manufacturer assumes no responsibility for damages resulting from non-application or incorrect application of the instructions provided herein. This device allows the breaker installed in comparatively deep motor control center or switchboard to be operated manually without the need for opening the panel of the motor control center or switchboard. Type: T1HP80 T1HPX6 Door-Mounted External Operating Handle Instruction Manual and ・ steps (No.2) Tube Operation unit Gasket for dust protection Key (optional) M5×60- 4pcs. (T1HP80), M6×100- 4pcs.(T1HPX6) Pan head screws Mounting plate in the Remarks column mean that the applicable product must be followed the and as shown in the figures above. M4×10- 4pcs. M4×14- 4pcs. Flat head screws (black) Square shaft Handle unit Packaged Items (4.5×50) (No.2) XE600NS, XS600CS, XS600NS, XS600NE, XH600NE, XS600NN, XS630CJ, XS630NJ, XS630NE, XH630NE, XS630NN, XS800CS, XS800NS, XS800NJ, XS800NE, XS800SE, XH800PS, XH800PJ, XH800NE, XH800SE, XH800PE, XS800NN, XS1000ND XS1000NE, XH1000NE, XS1000NN, XS1200NE, XH1200NE, XS1200NN, XS1250CE, XS1250NE, XS1250SE, XS1250NN TL-600NE, TL-800NE, TL-1000NE, TL-1200NE, XS1200ND, TL-1250NE, XS1250ND, XS1600CE, XS1600NE, XS1600SE, XS1600ND, XS1600NN Applicable breaker types 3.6 - 4.4 N・m Be sure to read these Instructions and other associated documents accompanying the product thoro- ughly to be familiarize yourself with the product handling, safety information, and all other precautions before mounting, using, servicing, or inspecting the product. In these Instructions, safety notices are divided into " Warning" and " Caution" according to the hazard level: Warning : A warning notice with this symbol indicates that neglecting the suggested procedure or practice could be fatal or result in serious personal injury. Caution : A caution notice with this symbol indicates that neglecting the suggested procedure or practice could result in moderate or slight personal injury and/or property damage. Note that failing to observe caution notices could result in serious injury/damage in some situations. Because safety notices contain important information, be sure to read and observe them. Safety Notices Assembly Tools D140 D120 - T1HP80 T1HPX6 Group Handle types Applicable Breaker Types Warning Square shaft installation positions Mounting direction (Default) Upper power supply type Square shaft installation positions Left power supply type 3.6 - 4.4 N・m Right power supply type :Referring to the table below, install the square shaft in the position matched to the change in breaker mounting direction. ■Installation Precautions ●Electrical work should only be undertaken by suitably qualified persons. ●Prior to commencing any work on the product, open an upstream circuit breaker or isolator to ensure that no voltage is applied to the product. Otherwise, electrical shock may result. ●To remain the switchboard panel closed securely, use appropriate hardware in addition to the panel lock of the handle. Using the panel lock only may result in damage to the switchboard panel. ■Operation Precautions ●When the breaker trips open automatically, remove the cause, then return the handle to the |(ON) position. Should a fault be interrupted, the breaker must be inspected. Otherwise, a fire may result. ●Do not apply excessive force to the operating knob. Otherwise, damage may occur. Caution ■Operation Precautions ●Never touch live terminals. Doing so may result in electric shock. Mounting M6 M4×14 mm 1.0-1.7N・m (No.2) Handle unit Panel :Screws position for removal M5 T1HPX6 Handle Operation ・This applies when the panel requires to be opened while the breaker is in the ┃ (ON) or for normal panel opening procedure. TRIP position. See (4.5×50) Gasket for dust protection Panel Opening Procedure by Panel Lock Release 2G0467SAA (KRB KRBKRB-0444) 0444 J H T1HP80 ・For detailed mounting dimensions, refer to the catalogue. TRIP Operation with the Panel Open (No.2) Handle catch :Screws position for mounting M5×60 mm M6×100 mm 3.6 - 4.4 N・m 6.0 - 7.4 N・m T1HPX6 ON Lock Operation OFF Lock Operation ・When unlocking, unlock the handle in reverse order of lock. Max×3 (φ5.5 - 8) ・Padlock is not supplied. Handle Lock Operation Max×3 (φ5.5 - 8) ・The figure shows the upper power supply type. For the right (left) power supply type, rotate all the components, excluding the handle unit and the panel, 90 degrees clockwise (counterclockwise). ・After mounting, verify the function of the device. ・Prior to removing, open an upstream circuit breaker or the like to isolate all sources of power/ voltage. Doing so may result in electric shock. When removing, remove the items in reverse order of mounting. I T1HP80 ・When unlocking, unlock the handle in reverse order of lock. ON Lock Operation OFF Lock Operation Key Lock Operation (Optional) ) OFF Open Type Panel Opening Procedure Reset Open Type Panel knob