TemBreak MCCB accessories
Accessories to suit XM30PB
Internal accessories (factory fit)
Cat. No.
Description
110 V AC SHT (100 - 115 V)
2H1931BAA
240 V AC SHT (200 - 480 V)
2H1931BBA
24 V DC SHT
2H1931BCA
48 V DC SHT
2H1931BDA
110 V DC SHT (100 - 115 V)
2H1931BEA
24 V AC SHT
2H1932BAA
48 V AC SHT
2H193DBBA
12 V DC SHT
2H1932BDA
125 V DC SHT
2H1932BGA
200 V DC SHT (200 - 230 V)
2H1932BHA
Auxiliary
AUX SW right/left hand 1 C
UXXB0001C
switches
AUX SW right/left hand 2 C
UXXB0003C
Alarm switches
Alarm SW right/left hand
UXLB0006C
Alarm & auxiliary
Alarm/AUX SW right/left hand 1 C
UXLB0008C
Shunt trip
Shunt trip
Alarm/auxiliary switch
6
switches
External accessories
3 P solderless terminals (6)
TXBD0009A
Rear connect studs
3 P rear connect studs (6)
UXRC0005A
Handle operators
Variable depth handle, door interlocking
XFHA1B
IP 55 direct mount rotary handle )
TFJ21PB
Handle lock
UXKH0009A
Tunnel Clamp
(solderless)
XFH Handle operator
terminals
1
Handle locks
UXKE0030A
Lock plate
Key interlock (Fortress type) incl TFJ mechanism )
-
3 P Templug
UPX330PB
2
TemPlug
Note:
1
) Flush plate included.
) Tech data Section 8.
2
Accessory lead terminal
Solderless terminal
6 - 14
Innovators in Protection Technology
MCCB Technical data - MCCB accessories
Handle mechanisms – XFH extended rotary type
(variable depth, IP 40)
This consists of an operating mechanism
mounted on the breaker, an operating
handle mounted on the panel door and a
square shaft to connect the mechanism
with the handle.
Handle lock (variations of use)
Figure A
The operating handle can be padlocked in
Vertical mounting
the “ON” or “OFF” position. The
(‘ON’ position up)
operating mechanism mounted on the
breaker can be padlocked (not supplied)
in the “ON” or “OFF” position.
Power source
Handle switch (Optional)
ON
I
O
Panel lock release knob
Anti-clockwise ‘ON’
standard
Figure B
A microswitch (contact 1C) may be fitted
onto the operating mechanism for ON-OFF
status indication and electrical
interlocking purposes.
Mounting direction of breaker
(indent only)
2. Horizontal with the “ON” position left
hand side (refer to figure B)
Operating direction of handle
There are two types:
Anti-clockwise for “ON” and clockwise
for “ON”. These are distinguished by
their designation.
Panel lock
Reset, Open (Standard Type)
Horizontal mounting
(‘ON’ position left hand side)
Figure C
3. Horizontal with the “ON” position right
hand side (refer to figure C)
Note:
Relative positioning of the breaker and the
handle (OHH) differs from one mounting
direction to another (refer to figure A,
B and C)
se
The external operating handle keeps
the panel door locked when in the
“ON” position. There are two types,
RESET, Open and OFF, Open.
O
st
i
re
gi
Clockwise ‘ON’
The breaker mounting directions are
allowed with this type of handle (OHH)
as follows:
1. Vertical with the “ON” position up.
(normal) (refer to figure A)
Power
source
!
I
er
ON
8
O
Power
source
Horizontal mounting
(‘ON’ position right hand side)
OFF, Open
ea
The handle is turned to the
“RESET”/“OPEN COVER” position to open
the panel door.
The handle is turned to the OFF position
to open the panel door.
Pl
Panel lock release knob
r!
The release knob enables the panel door
to be opened with the handle in the “ON”
position.
To release, turn the release knob in the
direction of the arrow (marked) with a
flat-bladed screwdriver.
Note:
i
Available on indent only.
is
IP 40
te
IP rating
8-5
Innovators in Protection Technology
MCCB Technical data - MCCB accessories
Handle mechanisms – XFH extended rotary type
(variable depth, IP 40)
Square shaft selection and cutting procedures
Measure the length (F) between the front cover surface and mounting face of the breaker (refer to figure A)
If the shaft measured is not the required length then cut the shaft to the required length (refer to figure B)
■ Colour of handle - black.
Figure A
Figure B
F'
(F-F')
(F)
LA-(F-F')
L A
Square shaft fixing screw
For types 1 and 2 size M5
For types 3 and 4 size M6
Position labels (two types)
ON and OFF or I and O.
8
Square shaft standard length
(refer to table below). For lengths other than those mentioned, the shaft can be cut to the correct length.
LB
LA
MCCB
LA (mm)
LB (mm)
125-250
400-1600
427
405
8
15.8
LB
Notes: By just ordering XFH A22 you will receive in kit form, handle mechanism to suit XS 125 A frame breakers.
TLK handles can be made “lock on” or “ lock off” as required when field assembled.
IP 65 handles are available with variable depth mounting refer NHP for details.
IP 65 handles incorporate XFH mechanism and support IP 65 handle and special shaft. (TLK type)
8-6
Innovators in Protection Technology
MCCB Technical data - MCCB accessories
Handle mechanisms – XFH extended rotary type
(variable depth, IP 40)
Outline dimensions (mm)
Anti-clockwise ‘On’
Standard
ASL: Arrangement Standard Line
HL:
Handle frame centre line
CL:
Handle centre line
Clockwise ‘On’
Non-standard (Indent only)
XFHA
XFHC
(anti-clockwise)
(clockwise)
standard type
small quantities stocked
Dimensions table (mm)
XM30PB
XS125
XH125
TL30F
160/225/250 XE225NC
XS250NJ
XH160PJ
XH250NJ
Note:
1
No. of Anti-clockwise
poles ON
3
3
4
XFHA1B
XFHA22
3
3
3
–
TFH23CB
XFHA23S 2)
XFHA23S 2)
–
Clockwise
ON
XFHC1B
XFC22
B
C
D
E
i
F
G
Shaft length
max.
min. 1)
25
30
78
90
120
4
72.75 81.25
77.5 77.5
494
488
H
I
J
134
125 30 66 66
26
25
is
t
e
se r!
re
gi
30
125
Applicable
breaker
TFH023CB
XFHC23S 2)
XFHC23S 2)
–
30 105 2.5
– 105 0
– 105 0
–
–
–
85
82.5
82.5
–
75
82.5
82.5
–
469
487
487
–
L
st
A
Frame (A)
e
8
39
45
102 35 68 58 17.5 52.5
120 35 63 63 17.5 52.5
120 35 63 63 17.5 52.5
–
137 – – –
–
) This dimension is the distance from the MCCB mounting.
) Use UXFD0016A when used with XH250 or XH160 panel/plate to the inside of the
enclosure door.
i Available on indent only.
2
8-7
Innovators in Protection Technology
MCCB Technical data - MCCB accessories
Handle mechanisms – XFH extended rotary type
(variable depth, IP 40)
ASL: Arrangement Standard Line
HL:
Handle frame centre line
CL:
Handle centre line
Outline dimensions (mm)
Anti-clockwise ‘On’
Standard
Clockwise ‘On’
Non-standard (Indent only)
XFHA
XFHC
(anti-clockwise)
(clockwise)
standard
non-standard, indent only
B
C
D
E
F
Applicable shaft
Max. Min. depth
Frame
(A)
Applicable
breaker
No. of Anti-clockwise
poles ON
Clockwise
ON
400
XS400
XH250PJ
XH400
XV400
XS630
XH630
XV630
XS800
XH800
XV800
XS/XV1250
XS1250
XS1600
XS1600
3
4
XFHA34
XFHC34
42 140
185
3
4
XFHA46
XFHC46
55 210 4.5 132 141 484
280
3
4
XFHA46
XFHC46
3
4
3
4
XFHA49
XFHC49
XFHA49
XFHC49
800
1250
1600
Notes: For larger frame MCCB refer XFE 10 handle page 8 - 11.
i Available on indent only.
8-8
H
I
J
K
L
d
(incl. MCCB)
4
130 130 482.5
160
45 107 107 22 100 70
70 117 126
sat s
ere
! re
630
i
G
gi
st
A
Dimensions table (mm)
er
!
8
M6
0
140 105 M8
55 280 4.5 132 141 484
280
70 117 126
0
140 105 M8
55 210 8.5 170 200 515
280
55 210 8.5 170 200 535
280
70 154 184
0
105 140 M8
70 154 184
0
105 140 M8
Innovators in Protection Technology
MCCB Technical data - MCCB accessories
Handle mechanisms – TFH extended rotary type
(variable depth, IP 40)
ASL: Arrangement Standard Line
HL:
CL:
Outline dimensions (mm)
Anti-clockwise ‘On’
Panel lock
release knob
A
Clockwise ‘On’
B
C
L
Handle frame centre line
Handle centre line
B
breaker centre
A
J
C
L
line end
line end
E
J
22.5
E
I
I
C
ASL
C
60
C
60
22.5
D
80
ASL
C
D
Panel lock release knob
load end
load end
C
L
A
C
L
A
C
L
ø40
ø40
MSL
I
C
66
C
ASL
66
ASL
C
H
ø6
ø6
G
66
66
MSL
Drilling plan for breaker
mounting holes
(front connection)
8
Panel cut-out
TFH
TFHO
(anti-clockwise)
(clockwise)
standard
non-standard, indent only
Dimensions table (mm)
A
Applicable
breaker
No. of Anti-clockwise
poles ON
Clockwise
ON
100
TL100F
TFH22D
TFH-022LC
225
TL225F
3
4
3
TFH33LE
TFH-033LE
B
C
D
E
i
F
Shaft length
1D4
G
H
I
J
L
re
gi
s
as te
e r!
re
gi
st
Frame (A)
er
Panel cut-out
30 105
42 140
140
5 82.5 82.5
82.5
527 35 64.5 64.5 17.5 52.5
5
218
53
12
131
87
127
12
100
80
Notes: For larger frame MCCB refer XFE 10 handle page 8 - 11.
i Available on indent only.
8-9
Innovators in Protection Technology
MCCB Technical data - MCCB accessories
TLKDA variable depth handles IP65
Features
■
■
■
■
■
■
IP 65. Plastic gasketed handle
Padlockable, max 5 padlocks or with a hasp
Can be field adjusted for “lock on” or lock off” (lock off std)
Door defeat can be removed (DD is standard)
Suitable for MCCBs 125 AF to 1600 AF
Comes with a 300 mm metal shaft
Type
TLKDA22
TLKDA22D
TLKDA23
TLKDA34
TLKDA46
TLKDA49
Suit MCCB Frame
125AF
250AF
400AF
630/800AF
1250/1600AF
MCCB type
XS/XH125, TL100NJ, TL30F
TL100EM
XH160PJ, XS/XH 250NJ
XS/XH400, TL25ONJ, TL400NE, XV400
XS800/XV800
XV/XS1250, XS1600SE, TL630, TL80, TL1250
Dimensions (mm)
TLKDA22
TLKDA22D
TLKDA23
TLKDA34
TLKDA46
TLKDA49
8
Door defeat mechanism
If the handle is ON, a door cannot be
opened unless the door defeat
mechanism is used. The door defeat
is accessed by drilling a 2.5 mm hole
through the mechanism side to a
depth of 5 mm - see locator hole.
A small object can then be inserted
to activate the door defeat.
It should be noted that once a hole
is made the IP rating of the handle
changes from IP65 to IP44.
8 - 10
Innovators in Protection Technology
MCCB Technical data - MCCB accessories
XFE, door mounted rotary handle 2000 / 2500 AF, IP 40
Type XFE 10
■ ON
Turn the handle clockwise to the “ON” position on the indication plate.
■ RESET
When the breaker trips, the handle indicates tripped. Turn the handle
anti-clockwise to the RESET position. This will reset the breaker.
OF
ES
R
EN
C
O
■ OPENING THE PANEL
Turn the handle anti-clockwise to “OPEN COVER”. The lock is released
and the panel can be opened.
Nameplate
F
OP
■ OFF
Turn the handle anti-clockwise to the “OFF” position on the indication
plate.
TRI
PP
ON
ED
VE
R
ET
Panel lock release
Handle
Outline dimension (mm) (breaker type XS2000NE, XS2500NE)
CL
Panel
130
Mounting hole ø 11
M3 x 0.5 tapped hole
for indication plate
8
220
CL
Hook catch
(supplied by user)
57.5
CL
130
ø42
55
ASL
195
ø13
28
140
78
80
180
CL
20
CL
160
Panel / door
CL
Hook catch
(supplied by user)
295
260
25
Mounting plate
Hook
Release
173.2
150
HL
(Rear type)
8 - 11
Innovators in Protection Technology
MCCB Technical data - MCCB accessories
TFJ, direct breaker mounted rotary type
This is used when the breaker is installed in a control centre /
switchboard, and is fitted on the breaker directly.
Double insulation
Provides an even higher degree of safety; all controls are
composed of insulation materials.
Panel lock release
When the release knob is turned anti-clockwise, the panel door
can be opened irrespective of the handle being in the ‘On’,
‘Off’ or ‘Trip’ position.
Reverse interlock
The reverse interlock is designed to lock the breaker, to
prevent it from being switched ‘On’ when the panel door is
opened. The lock can be released by pushing the hook
lever.
Dust and water protected
IP 55 is available as standard.
Panel lock
The external operating handle keeps the panel door locked
when the handle is in the ‘On’ or ‘Off’ position. The panel
door can be opened in ‘Reset’ position.
Handle lock
The operating handle can be padlocked in the ‘On’ or ‘Off’
position with up to 3 padlocks. (The padlock is not supplied.)
Lock in off position only available as special execution
refer NHP.
Mounting direction of breaker
Upper power supply
R: Right power supply
L: Left power supply
Fix turnovers to one
column width
8
Note:
The handle operation is the same irrespective of the breaker mounting direction,
being vertical or horizontal. This also applies to the panel cut-out.
Upper power supply type is standard. Please specify the correct type code when ordering. e.g. U, R or L.
TFJ handle installed on an XS125NJ
MCCB plus padlock (not supplied)
8 - 12
Applicable padlock dimensions (mm)
Handle series
A
Diameter
TFJ2
TFJ3
3.5 - 6
3.5 - 6
13 or more
19 or more
Innovators in Protection Technology
MCCB Technical data - MCCB accessories
TFJ, direct mounting operating handles
90° ON
OFF operation
ON
OFF
Double insulation structure
Operating
handle
Provides an even higher degree of safety; all controls are
composed of insulated materials.
Panel lock mechanism
The panel door cannot be opened when the handle is in the
ON or OFF position. The panel door can be opened when the
handle is in the RESET position.
■ Equipped with a lock (reverse interlock) mechanism
which does not permit the breaker to be closed while
the panel door is open. The lock can be released.
Lock lever
Panel lock
release
■ When the panel lock release is turned counterclockwise
the panel door can be opened even when the handle is
in the ON or OFF position.
Breaker mount direction and
operating handle mount direction
The handle operation and ON/OFF indicator are the same
irrespective of the breaker mounting direction, being
vertical or horizontal.
Handle lock mechanism
8
The handle can be locked in the ON or OFF
position. Up to 3 padlocks can be set.
(Padlock not supplied.)
This also applies to the panel cut-out.
1 - 3 Padlocks
Dust and water protected IP 55
Without gasket
(standard) IP 3X
With gasket
IP 55
8 - 13
Innovators in Protection Technology
MCCB Technical data - MCCB accessories
TFJ, direct breaker mounted rotary type handle
Outline dimensions (mm)
Panel cut-out
Type TFJ2
Drilling plan for breaker
mounting holes
Min. distance from door
hinge to mounting
position (View from
load side)
Type TFJ3
Panel cut-out
8
Drilling plan for breaker
mounting holes
Min. distance from door
hinge to mounting
position (View from
load side)
Extension handle for TFJ3 (option)
ASL: Arrangement Standard Line
HL:
Handle frame centre line
CL:
Handle centre line
Dimensions table (mm)
Type 1) 3)
TFJ21PB
TFJ22XU
TFJ23CU
TFJ23SU
TFJ23SU
TFJ34XU
TFJ36XU
TFJ38XU
Notes:
1
0
0
M4 x 102 2 pcs
–
–
M4 x 40 4 pcs
35
35
35
45
2-M4 x 0.7 tapped
2-M4 x 0.7 tapped
(44P:4-M4 x 0.7 tapped)
4-M4 x 0.7 tapped
4-M4 x 0.7 tapped
4-M4 x 0.7 tapped
4-M6 tapped
–5
0
0
0
M4 x 70 4 pcs
M4 x 95 4 pcs
M4 x 110 4 pcs
–
–
–
–
M5 x 70 4 pcs
117
70
4-M8 tapped
+4.5
–
M5 x 60 4 pcs
154
70
4-ø9
+15
–
M6 x 105 4 pcs
No. of
poles
Dimensions (mm)
A
B1
B2
C
XM30PB
XS125
XH125
XE225
XS250
XH250NJ, XH160PJ 3)
XS400, XH400,
XH250PJ, XV400
XS630, XH630,
XS800, XV630
XH800, XV800
XS1250, XV1250
XS1600
3
3, 4
128
124
57.5
66
57.5
66
25
30
3, 4
3, 4
3, 4
3, 4
101.5
130
147
157
58
63
63
107
68
63
63
107
3, 4
168
126
3, 4
3, 4
197
217
184
Mounting
hole d
) When a horizontal breaker mount direction is required an “–R” or “–L” is added to the end of the Cat. No.
) If ASL accords with CL E=0; If ASL is below CL, E comes “+” dimensions; If ASL is above CL, E come “–” dimension.
3
) Flush plates included
2
8 - 14
E 2)
Mounting the
handle along
with breaker
Applicable
breaker
Attaching the
handle to breaker
in advance
Innovators in Protection Technology
MCCB Technical data - MCCB accessories
Extension handle for larger MCCBs
630 - 2500 AF
Caution! The lock pins are spring loaded.
Removal - Pull out left and right hand lock pins and hold while removing.
Outline dimensions (mm)
Type 2A2272BAB
(630 - 1600 AF)
Type UXHB0001B
(2000 / 2500 AF)
8
Applicable breakers
Applicable breakers
XS630, XV630
XH630
XS800
XH800, XV630
XS1600
XS1250, XV1250
XS2000NE
Please order when required.
XS2500NE
Handle is supplied as standard
with each breaker.
Please order when required.
Note: Allow several minutes to cool when a thermal-magnetic
trip breaker is tripped by a thermal overload, then reset the breaker.
Handle mounting and removal (Refer above). Pull lock pins out left and
right in the direction of the arrows, and slot the extension handle in
place.
8 - 15