Packaged Items Applicable Breaker Types Handle types T1HP80 Door-Mounted External Operating Handle Instruction Manual T1HPX6 Group − D120 D140 Applicable breaker types XE600NS, XS600CS, XS600NS, XS600NE, XH600NE, XS600NN, XS630CJ, XS630NJ, XS630NE, XH630NE, XS630NN, XS800CS, XS800NS, XS800NJ, XS800NE, XS800SE, XH800PS, XH800PJ, XH800NE, XH800SE, XH800PE, XS800NN, XS1000ND XS1000NE, XH1000NE, XS1000NN, XS1200NE, XH1200NE, XS1200NN, XS1250CE, XS1250NE, XS1250SE, XS1250NN TL-600NE, TL-800NE, TL-1000NE, TL-1200NE, XS1200ND, TL-1250NE, XS1250ND, XS1600CE, XS1600NE, XS1600SE, XS1600ND, XS1600NN Assembly Tools Type: T1HP80 T1HPX6 Handle unit Mounting plate Operation unit (4.5×50) This device allows the breaker installed in comparatively deep motor control center or switchboard to be operated manually without the need for opening the panel of the motor control center or switchboard. Square shaft (No.2) Tube Safety Notices Please retain this manual for future reference. The Manufacturer assumes no responsibility for damages resulting from non-application or incorrect application of the instructions provided herein. M4×14- 4pcs. Flat head screws (black) M5×60- 4pcs. (T1HP80), M6×100- 4pcs.(T1HPX6) Pan head screws 7-2-10 Kamihigashi, Hiranoku, Osaka 547-0002, Japan TEL:81-6-6791-9323/ FAX:81-6-6791-9274 Web Site: www.terasaki.co.jp Email: int-sales@terasaki.co.jp Gasket for dust protection 2G0467SAA (KRB-0444) Key (optional) The Handle Depth/ The Mounting Direction Changing Procedure M4×10- 4pcs. (No.2) Handle types T1HP80 T1HPX6 Group − D120 D140 E [mm] F [mm] G [mm] 298∼368 368∼638 327∼397 397∼667 347∼417 417∼687 E-190.5 E-190.5 E-219.5 E-219.5 E-239.5 E-239.5 E-286 E-358 E-315 E-387 E-335 E-407 remarks − − − ・ ・ Perform the anti-rust treatment to the metal section. and steps in the Remarks column mean that the applicable product must be followed the and as shown in the figures above. Be sure to read these Instructions and other associated documents accompanying the product thoro- ughly to be familiarize yourself with the product handling, safety information, and all other precautions before mounting, using, servicing, or inspecting the product. In these Instructions, safety notices are divided into " Warning" and " Mounting Panel Opening Procedure Reset Open Type ・ For detailed mounting dimensions, refer to the catalogue. T1HP80 T1HPX6 T1HP80 Panel knob T1HPX6 H M5 I M6 :Screws position for removal M5×60 mm M6×100 mm 3.6 - 4.4 N・m 6.0 - 7.4 N・m :Screws position for mounting Gasket for dust protection Panel Handle catch OFF Open Type Handle unit (No.2) (No.2) J ・ The figure shows the upper power supply type. For the right (left) power supply type, rotate all the components, excluding the handle unit and the panel, 90 degrees clockwise (counterclockwise). ・ After mounting, verify the function of the device. ・ Prior to removing, open an upstream circuit breaker or the like to isolate all sources of power/ voltage. Doing so may result in electric shock. When removing, remove the items in reverse order of mounting. M4×14 mm 1.0-1.7N・m 2G0467SAA (KRB-0444) Panel Opening Procedure by Panel Lock Release TRIP Operation with the Panel Open Handle Lock Operation Key Lock Operation (Optional) ・ Padlock is not supplied. OFF Lock Operation (4.5×50) OFF Lock Operation Max×3 (φ5.5 - 8) ・ This applies when the panel requires to be opened while the breaker is in the ┃ (ON) or TRIP position. See for normal panel opening procedure. Handle Operation ON Lock Operation ON Lock Operation Max×3 (φ5.5 - 8) ・ When unlocking, unlock the handle in reverse order of lock. ・ When unlocking, unlock the handle in reverse order of lock.