LM6400 Latch Monitor Installation Instructions

advertisement
*24236291*
24236291
Patent
Pending
LM6400 Latch Monitor
Installation Instructions
Improved design to accommodate
1/2" - 3/4" latch throw.
Latch Monitor Wires
(door open no latch)
Black = Common (C)
Blue = Normally Closed (NC)
Orange = Normally Open (NO)
24VDC
Terminal
12VDC
12-24VAC
Terminal
Switch Type: SPDT
Switch Rating: 2 Amp @ 24 VDC
+
-
+
-
Black
Black
Latch
Monitor
Latch Monitor Cables
C
NC
NO
Red
Red
Wiring the LM6400 Series Electric Strike
Adjust Latch Monitor Module:
Step 1:
Step 2:
Step 3:
Step 4:
Step 5:
Step 6:
Carefully remove faceplate from strike insert. Make sure the deadbolt and deadlatch alignments
don’t change.
Move the door towards the strike so that the latch touches the keeper.
Mark latch limit lines on keeper (Fig. 1).
Open the door. Mount the Latch Monitor Module on the strike housing so that it is between the
latch limit lines marked on keeper.
Make electrical connection, position the faceplate onto the strike and secure to the frame.
NOTE: To avoid pinching wires, ensure wires run through wiring channel before inserting strike
into frame (see Fig. 2).
Test the door to ensure that the latch depresses the LM lever. If the latch doesn’t depress the LM
lever, the ribs must be trimmed with side cutters (Fig. 3).
Wire
Channel
Fig.1
Fig.2
Fig.3
© Allegion 2015
24236291 Rev. 10/15-d
5.500
5.500
FRONT
FRONT
4.250
8.500
BEGINNING SHEET
FOLDED SHEET
Additional Notes:
1. None
Revision History
A
B
C
030274
060874
063958
Material
D
White Paper
Notes
1. printed black
2. tolerance ± .13
3. printed in country may vary
4. drawings not to scale
E
F
Revision Description:
d > Revised artwork
Edited By
Approved By
J. Ellis
M. Roberts
EC Number
Release Date
10-27-15
Title
INSTRUCTION SHEET, INSTALL, LM6400 LATCH MON