DDU12H data 3 delay devices, inc. 5-TAP, ECL-INTERFACED FIXED DELAY LINE (SERIES DDU12H) FEATURES PACKAGES GND • • • Ten equally spaced outputs Fits in 300 mil 32-pin DIP socket Input & outputs fully 10KH-ECL interfaced & buffered 1 32 GND 31 T1 T2 3 30 T3 T4 4 29 T5 IN 5 VEE 8 GND 9 24 GND 23 T6 T2 11 22 T8 T4 12 21 T10 DDU12H-xx DIP DDU12H-xxM Military DIP GND T2 T4 IN N/C VEE GND N/C N/C T7 T8 VEE 1 2 3 4 5 6 7 8 9 10 11 12 24 23 22 21 20 19 18 17 16 15 14 13 GND T1 T3 T5 N/C N/C GND N/C N/C T6 T8 T10 DDU12H-xxC4 SMD DDU12H-xxMC4 Mil SMD VEE 16 FUNCTIONAL DESCRIPTION PIN DESCRIPTIONS The DDU12H-series device is a 10-tap digitally buffered delay line. The IN Signal Input signal input (IN) is reproduced at the outputs (T1-T10), shifted in time by T1-T10 Tap Outputs an amount determined by the device dash number (See Table). For dash VEE -5 Volts numbers less than 20, the total delay of the line is measured from T1 to GND Ground T10. The nominal tap-to-tap delay increment is given by one-ninth of the total delay, and the inherent delay from IN to T1 is nominally 1.5ns. For dash numbers greater than or equal to 20, the total delay of the line is measured from IN to T10. The nominal tap-to-tap delay increment is given by one-tenth of this number. SERIES SPECIFICATIONS • • • • • • DASH NUMBER SPECIFICATIONS Minimum input pulse width: 10% of total delay Output rise time: 2ns typical Supply voltage: -5VDC ± 5% Power dissipation: 400mw typical (no load) Operating temperature: -30° to 85° C Temp. coefficient of total delay: 100 PPM/°C 1.5ns VCC IN 10% T1 10% T2 10% T3 10% T4 10% T5 10% T6 10% T7 10% T8 10% T9 T10 GND Functional diagram for dash numbers < 20 10% VCC IN 10% T1 10% T2 10% T3 10% T4 10% T5 10% T6 10% T7 10% T8 10% T9 T10 GND Functional diagram for dash numbers >= 20 1997 Data Delay Devices Doc #97036 5/3/2006 Part Number DDU12H-10 DDU12H-20 DDU12H-25 DDU12H-40 DDU12H-50 DDU12H-75 DDU12H-100 DDU12H-150 DDU12H-200 DDU12H-250 DDU12H-300 DDU12H-400 DDU12H-500 DDU12H-750 DDU12H-1000 DDU12H-1500 Total Delay (ns) 9 ± 1.0 * 20 ± 2.0 25 ± 2.0 40 ± 2.0 50 ± 2.5 75 ± 4.0 100 ± 5.0 150 ± 7.5 200 ± 10.0 250 ± 12.5 300 ± 15.0 400 ± 20.0 500 ± 25.0 750 ± 37.5 1000 ± 50.0 1500 ± 75.0 Delay Per Tap (ns) 1.0 ± 0.3 2.0 ± 0.4 2.5 ± 0.4 4.0 ± 0.5 5.0 ± 1.0 7.5 ± 1.5 10.0 ± 2.0 15.0 ± 2.0 20.0 ± 2.0 25.0 ± 2.0 30.0 ± 2.0 40.0 ± 2.0 50.0 ± 2.5 75.0 ± 4.0 100.0 ± 5.0 150.0 ± 7.0 * Total delay is referenced to first tap output Input to first tap = 1.5ns ± 1ns NOTE: Any dash number between 10 and 1500 not shown is also available. DATA DELAY DEVICES, INC. 3 Mt. Prospect Ave. Clifton, NJ 07013 1 DDU12H APPLICATION NOTES Delay Devices if your application requires device testing at a specific input condition. HIGH FREQUENCY RESPONSE The DDU12H tolerances are guaranteed for input pulse widths and periods greater than those specified in the test conditions. Although the device will function properly for pulse widths as small as 10% of the total delay and periods as small as 20% of the total delay (for a symmetric input), the delays may deviate from their values at low frequency. However, for a given input condition, the deviation will be repeatable from pulse to pulse. Contact technical support at Data POWER SUPPLY BYPASSING The DDU12H relies on a stable power supply to produce repeatable delays within the stated tolerances. A 0.1uf capacitor from VEE to GND, located as close as possible to the VEE pin, is recommended. A wide VEE trace and a clean ground plane should be used. DEVICE SPECIFICATIONS TABLE 1: ABSOLUTE MAXIMUM RATINGS PARAMETER DC Supply Voltage Input Pin Voltage Storage Temperature Lead Temperature SYMBOL VEE VIN TSTRG TLEAD MIN -7.0 VEE - 0.3 -55 MAX 0.3 0.3 150 300 UNITS V V C C NOTES 10 sec TABLE 2: DC ELECTRICAL CHARACTERISTICS (0C to 75C) PARAMETER High Level Output Voltage Low Level Output Voltage High Level Input Voltage Low Level Input Voltage High Level Input Current Low Level Input Current Doc #97036 5/3/2006 SYMBOL VOH VOL VIH VIL IIH IIL MIN -1.020 -1.950 TYP MAX -0.735 -1.600 -1.070 -1.480 475 0.5 UNITS V V V V µA µA NOTES VIH = MAX,50Ω to -2V VIL = MIN, 50Ω to -2V VIH = MAX VIL = MIN DATA DELAY DEVICES, INC. Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com 2 DDU12H PACKAGE DIMENSIONS 32 31 30 29 24 23 22 21 .400 TYP. 1 3 4 5 8 9 11 12 16 1.650 TYP. .020 .320 TYP. MAX. .150 ±.030 .018 TYP. .100 .200 .300 .400 .012 TYP. .300 TYP. .700 .800 .900 1.000 1.100 1.500 .075 DDU12H-xx (Commercial DIP) DDU12H-xxM (Military DIP) .020 TYP. .040 TYP. .010±.002 24 23 22 21 20 19 18 17 16 15 14 13 .882 ±.00 .710 .590 ±.00 MAX. 1 2 3 4 5 6 7 8 .090 9 .007 ±.00 10 11 12 .100 1.100 1.280±.020 .320 MAX. .050 ±.01 DDU12H-xxC4 (Commercial SMD) DDU12H-xxMC4 (Military SMD) Doc #97036 5/3/2006 DATA DELAY DEVICES, INC. 3 Mt. Prospect Ave. Clifton, NJ 07013 3 DDU12H DELAY LINE AUTOMATED TESTING TEST CONDITIONS INPUT: Ambient Temperature: 25oC ± 3oC Supply Voltage (Vcc): -5.0V ± 0.1V Input Pulse: Standard 10KH ECL levels Source Impedance: 50Ω Max. Rise/Fall Time: 2.0 ns Max. (measured between 20% and 80%) Pulse Width: PWIN = 1.5 x Total Delay Period: PERIN = 10 x Total Delay OUTPUT: Load: Cload: Threshold: 50Ω to -2V 5pf ± 10% (VOH + VOL) / 2 (Rising & Falling) NOTE: The above conditions are for test only and do not in any way restrict the operation of the device. PULSE GENERATOR OUT IN TRIG DEVICE UNDER TEST (DUT) T1 REF T2 IN T3 TRIG OSCILLOSCOPE T4 T5 T6 T7 T8 T9 T10 Test Setup PERIN PW IN TRISE INPUT SIGNAL TFALL VIH 80% 50% 20% 80% 50% 20% TRISE OUTPUT SIGNAL VIL TFALL 50% VOH 50% VOL Timing Diagram For Testing Doc #97036 5/3/2006 DATA DELAY DEVICES, INC. Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com 4