NSHXAFö 3kVhalogen-free Special Rubber

advertisement
NSHXAFö 3kV halogen-free Special Rubber-Insulated Cable, VDE approved,
short-circuit up to 1000V
Technical data
Cable structure
Properties
Ⴠ Special rubber core cable acc. to
EDINVDE0250 Teil606
Ⴠ Temperature range
flexing -25 °C to +70 °C
fixed installation -40 °C to +90 °C
Ⴠ Permissible operating temperature
at conductor +90 °C
Ⴠ Nominal voltage U0/U 1,8/3 kV
Ⴠ Highest permissible operating voltage
in three-phase and one-phase
a.c. systems U0/U 2,1/3,6 kV
in d.c. systems U0/U 2,7/5,4 kV
Ⴠ Test voltage 6 kV
Ⴠ Minimum bending radius
flexing 10x cable ø
fixed 6x cable ø
Ⴠ Bare or tinnedcopper conductor, fine wire
to DINVDE0295 cl.5, BS6360 cl.5 and/or
IEC60228 cl.5
Ⴠ EPR-insulation, 3GI3 acc. to DINVDE0207
part20
Ⴠ Halogen-free, polymer sheath GM3 acc. to
DINVDE0207 part24
Ⴠ Colour black
Tests
Ⴠ Corrosiveness of corrosive gases acc. to
VDE0482, part267/ DINEN50267-2-2/
IEC607542 (as per DINVDE0472, part813)
Ⴠ Smoke density acc. to DINVDE0482,
part268 HD606, EN50268-1+2/
IEC61034-1+2, BS7622 part1+2 (as per
DINVDE0472, part816)
Ⴠ Oil resistant acc. to DINVDE0473
part811-2-1
Ⴠ Behaviour in fire: Test acc. to VDE
0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Application
Particularly suitable for protection against short circuits in laying and for inherently earth-fault-proof routing in rail vehicles and omnibuses.
Also suitable for laying in dry environments. In switching units and distributors, they are considered to be short circuit and inherently earth
proof to 1000 V. Note: Considered as being short-circuit safe and inherently earth-fault-proof are those operating materials and conducting
assemblies where because of suitable measures and/or means applied, neither a short circuit nor a short to ground is to be expected under
operating conditions which are in accordance with those specified for the intended application.
Part no.
38517
38518
38519
38520
38521
38522
38523
38524
No.cores x
cross-sec.
mm²
1x1,5
1x2,5
1x4
1x6
1x10
1x16
1x25
1x35
Outer Ø
approx. mm
5,9
6,2
6,8
7,4
8,7
9,5
11,9
13,1
Cop.
weight
kg/km
14,4
24,0
38,0
58,0
96,0
154,0
240,0
336,0
Weight
approx.
kg/km
62,0
76,0
95,0
140,0
190,0
270,0
410,0
490,0
AWG-No.
16
14
12
10
8
6
4
2
Part no.
38525
38526
38527
38528
38529
38530
38531
38532
No.cores x
cross-sec.
mm²
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
Outer Ø
approx. mm
14,5
16,3
19,2
21,0
22,8
24,8
27,1
30,3
Cop.
weight
kg/km
480,0
672,0
912,0
1152,0
1440,0
1776,0
2304,0
2880,0
Weight
approx.
kg/km
650,0
900,0
1200,0
1450,0
1800,0
2200,0
2650,0
3250,0
AWG-No.
1
4
3/0
4/0
300 kcmil
350 kcmil
500 kcmil
600 kcmil
Dimensions and specifications may be changed without prior notice. (RK01)
K 36
K
Download