NSHXAFö 3kV halogen-free Special Rubber-Insulated Cable, VDE approved, short-circuit up to 1000V Technical data Cable structure Properties Ⴠ Special rubber core cable acc. to EDINVDE0250 Teil606 Ⴠ Temperature range flexing -25 °C to +70 °C fixed installation -40 °C to +90 °C Ⴠ Permissible operating temperature at conductor +90 °C Ⴠ Nominal voltage U0/U 1,8/3 kV Ⴠ Highest permissible operating voltage in three-phase and one-phase a.c. systems U0/U 2,1/3,6 kV in d.c. systems U0/U 2,7/5,4 kV Ⴠ Test voltage 6 kV Ⴠ Minimum bending radius flexing 10x cable ø fixed 6x cable ø Ⴠ Bare or tinnedcopper conductor, fine wire to DINVDE0295 cl.5, BS6360 cl.5 and/or IEC60228 cl.5 Ⴠ EPR-insulation, 3GI3 acc. to DINVDE0207 part20 Ⴠ Halogen-free, polymer sheath GM3 acc. to DINVDE0207 part24 Ⴠ Colour black Tests Ⴠ Corrosiveness of corrosive gases acc. to VDE0482, part267/ DINEN50267-2-2/ IEC607542 (as per DINVDE0472, part813) Ⴠ Smoke density acc. to DINVDE0482, part268 HD606, EN50268-1+2/ IEC61034-1+2, BS7622 part1+2 (as per DINVDE0472, part816) Ⴠ Oil resistant acc. to DINVDE0473 part811-2-1 Ⴠ Behaviour in fire: Test acc. to VDE 0482-332-1-2, DIN EN 60332-1-2/ IEC60332-1 (equivalent DINVDE0472 part804 test methodB) Application Particularly suitable for protection against short circuits in laying and for inherently earth-fault-proof routing in rail vehicles and omnibuses. Also suitable for laying in dry environments. In switching units and distributors, they are considered to be short circuit and inherently earth proof to 1000 V. Note: Considered as being short-circuit safe and inherently earth-fault-proof are those operating materials and conducting assemblies where because of suitable measures and/or means applied, neither a short circuit nor a short to ground is to be expected under operating conditions which are in accordance with those specified for the intended application. Part no. 38517 38518 38519 38520 38521 38522 38523 38524 No.cores x cross-sec. mm² 1x1,5 1x2,5 1x4 1x6 1x10 1x16 1x25 1x35 Outer Ø approx. mm 5,9 6,2 6,8 7,4 8,7 9,5 11,9 13,1 Cop. weight kg/km 14,4 24,0 38,0 58,0 96,0 154,0 240,0 336,0 Weight approx. kg/km 62,0 76,0 95,0 140,0 190,0 270,0 410,0 490,0 AWG-No. 16 14 12 10 8 6 4 2 Part no. 38525 38526 38527 38528 38529 38530 38531 38532 No.cores x cross-sec. mm² 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 Outer Ø approx. mm 14,5 16,3 19,2 21,0 22,8 24,8 27,1 30,3 Cop. weight kg/km 480,0 672,0 912,0 1152,0 1440,0 1776,0 2304,0 2880,0 Weight approx. kg/km 650,0 900,0 1200,0 1450,0 1800,0 2200,0 2650,0 3250,0 AWG-No. 1 4 3/0 4/0 300 kcmil 350 kcmil 500 kcmil 600 kcmil Dimensions and specifications may be changed without prior notice. (RK01) K 36 K