THM Standard: PSN 1209/95 CONSTRUCTION Conductor: Soft annealed tinned copper wire of 0.6; 0.8; 1.0; 1.2 (mm) diameter. Insulation: halogen free polymer. Insulation color: red, grey, black, orange, blue, yellow, brown, green. APPLICATION For internal connections in telecommunication devices or for their connection. Substitute TM 20.. Basic characteristics of this cable in case of fire: - do not spread fire and flame (according to DIN VDE 0472 part 804 and IEC 60332-3 method C), - products of the combustion are not corrosive (according to DIN VDE 0472 part 813 and IEC 61034 IEC 60754-2), - low smoke density during combustion (according to DIN VDE 0472 part 816 method C). - do not contain halogen elements (according to DIN VDE 0472 part 815). TECHNICAL DATA Permissible temperatures: - At laying: - 5°C up to + 50°C - Before and after laying: up to + 7°C Bending radius, min. 15D (D – installation wire diameter) Electrical characteristics Characteristic Value for Unit Conductor resistance, max. at 20°C Insulation resistance, min. at 60°C Dielectric strength, 1 minute ohm/km M ohm km Veff 0.6 mm 0.8 mm 1.0 mm 63 1 2000 35.5 1 2000 23 0.8 2000 1.2 mm 16 0.8 2000 Data for some construction nxd mm 1x0.6 1x0.8 1x1.0 1x1.2 Cu kg/km 2.7 4.8 7.5 11.0 n - number of wires d – nominal cross section of the conductor, D – installation wire diameter, Q – weight of the cable D mm Q kg/km 1.4 1.8 2.0 2.2 4.5 8.0 11.0 14.0