PORTFOLIO TM D ES C R IPTION Low brightness 7-3/8-inch aperture lens downlight for use with a 26W or 32W Triple Twin Tube 4-pin lamp. The deeply regressed lens provides superb shielding in comparision to shallow lenses. Reflector trim eliminates brightness at higher angles. Choice of lens types for various aesthetics. Standard features include low iridescent finish on all reflector colors to eliminate "rainbowing" and one electronic ballast. Venting ensures lamp life and lumen output. Optics offer unparalleled performance in glare free lighting with a smooth beam devoid of hot spots. Medium beam, wide beam, lensed and open wall wash trims are interchangeable within the same housing. Type Catalog # Project Date Comments Prepared by S PEC IFIC A TION FEA T U R E S Ref l e c t o r Hous i ng Mount ing Frame S o ck et .050" thick aluminum, in a one piece spun macrofocal parabolic contour. Available in a variety of Alzak® finishes. Also available with white or black baffle. Positive reflector mounting pulls trim tight to ceiling. One piece precision die cast aluminum 1-1/2" deep collar accommodates varying dimensions of ceiling materials. 4 pin GX24q-3/4 base with fatigue free stainless steel lamp spring ensures positive lamp retention. Len s Choice of tempered fresnel, prismatic, diffuse, or clear glass lenses or molded prismatic acrylic, opal diffuser or clear UV stablized acrylic. Lens is fixed to lower reflector. Soc k e t C a p One piece vented and finned die cast aluminum cap for maximum thermal performance. E lectron ic B allast Accepts 1/2" EMT, C Channel, T bar fasteners, and bar hangers. Adjusts 5" vertically from above or below ceiling. Electronic ballast provides full light output and rated lamp life. Provides flicker free and noise free operation and starting. End of lamp life protection is standard. Condui t F i tti ngs Lab els Die cast screw tight connectors. cULus listed, standard wet label. U ni v e rs a l Mounting B racket C7042 7081/80 J unc ti on Box Listed for eight #12AWG (four in, four out) 90°C conductors feed through branch wiring. 1/2" and two 3/4" pry outs. Positioned to allow straight conduit runs. Access to junction box by removing reflector. 26W, 32W TTT or PLT Compact Fluorescent STEPREPEAT> 7-Inch Vertical Lensed Downlight Top View ENERGY DATA 26W TTT 4-pin . 13-5/16" [338mm] 12-1/4" [311mm] Ballast: Electronic 120V Input Watts: 29 Line Amps: 0.25 277V Input Watts: 29 Line Amps: 0.10 Power Factor: >0.99 THD: <10% Min. Starting Temperature: -10°C (15°F) Sound Rating: Class A Standards CP 12-3/4" [324mm] 32W TTT 4-pin Ballast: Electronic 13-3/4" [349mm] 120V Input Watts: 36 Line Amps: 0.32 277V Input Watts: 36 Line Amps: 0.16 Power Factor: >0.99 THD: <10% Min. Starting Temperature: -10°C (10°F) Sound Rating: Class A Standards NOTES: Accessories should be ordered separately. For additional options, please consult your Cooper Lighting Representative. Alzak is a registered trademark of Aluminum Company of America. 17" [432mm] 7-3/8" [187mm] 8-1/8" [206mm] 8-3/4" [222mm] 17-5/8" [447mm] ( w i t h E M O p t i o n) Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. ADP040649 2013-09-26 16:12:33 C7042 7081/80 OR D ER IN G INFOR M A TION EXAMPLE: C7042E 7080LI2 Housing Wa tt a ge Options Tri m s CP=Chicago Plenum EM=Emergency Module with RemoteTest Switch 7081=Self Flanged 7080=Molded Trim Ring, White Ballast C70=7" CF Vertical 42= (1) 26W or 32W TTT or PLT Lamp Finish E=120/277V 50/60Hz Electronic 3E=347V 50/60 Hz Electronic D5LT26=26W 120-277V Fifth Light (DALI Dimming) D5LT32=32W 120-277V Fifth Light (DALI Dimming) 3D5LT26/32=26 or 32W 347V Fifth Light (DALI Dimming) D26/32=26 or 32W 120-277V Lutron Ecosystem Dimming EDR26=DeRated Wattage Label, 26W EDR32=DeRated Wattage Label, 32W Lens LI=Low Iridescent Clear H=Haze WMH=Warm Haze G=Gold WH=Wheat W=Gloss White GP=Graphite GPH=Graphite Haze BB=Black Baffle (7080 only) WB=White Baffle (7080 only) A c c e s s o ri e s Options 1=Prismatic Lens 2=Diffuse Lens 3=Clear Lens 1G=Prismatic Glass 2G=Diffuse Glass 3G=Clear Glass 4G=Fresnel Glass HB26=C Channel Bar Hangers, 26" Long, Pair HB50=C Channel Bar Hangers, 50" Long, Pair FK5=5 Amp Field Installable Fuse Kit 300V Max RMB-22=Wood Joist Bar Hanger, 22" Long, Pair HSA7=Slope Adapter for 7" Aperture Housings, Specify Slope WF=White Painted Flanged (Self Flanged only) PHOTOM ETR IC S C7042 7081/7080 Test No. H23391 C7042-7080L14G 300 Lamp=32W TTT Lumens=2400 Spacing Criterion=1.0 Efficiency=45.9% 600 900 Zonal Lumen Summary %Lamp 23.7 34.0 Average Luminance Candlepower Candlepower Distribution Deg. 0 5 15 CD 794 797 766 Deg. 45 55 65 25 35 610 393 75 85 45 55 65 75 226 100 8 3 85 90 1 0 Cone of Light CD/SQ M 11577 6349 721 434 458 Lumens 570 816 %Luminaire 51.7 74.1 0-60 0-90 1081 1101 45.0 45.9 98.1 100.0 90-180 0-180 0 1101 0.0 45.9 0.0 100.0 6'0" 7'0" 8'0" 10'0" 12'5" 15'0" Beam Diameter 5.0' 6.0' 7.0' 9.0' 11.0' 13.5' 22 16 12 8 5 4 Footcandle values are initial, apply appropriate light loss factors where necessary. Reflector EM Multiplier Multiplier: (in emergency mode) Haze=.95 Straw=.9 Wheat=.9 80% rc Initial Nadir Footcandles Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. C o e f fi c i e n t o f U t i l i z a t i o n Zone 0-30 0-40 Distance to Illuminated Plane 70% EM=.27 50% 30% 10% 0% rw RCR 0 70 50 30 10 50 30 10 50 10 50 10 50 10 0 55 55 55 55 53 53 53 51 51 49 49 47 47 46 1 2 52 48 45 50 46 42 49 44 39 48 42 37 49 45 41 48 43 39 47 41 37 47 43 40 45 40 36 46 42 39 44 39 36 44 41 38 43 39 35 42 38 34 3 4 42 38 35 33 38 35 33 37 32 36 32 35 32 31 5 40 35 32 30 35 32 30 34 29 33 29 32 29 28 6 37 35 33 30 29 27 27 25 32 30 29 27 27 25 31 29 27 24 31 29 27 24 30 28 26 24 26 23 33 28 25 23 28 25 23 27 22 27 22 26 22 22 31 26 23 21 26 23 21 25 21 30 24 21 19 24 21 19 24 19 rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio CU Data Based on 20% Effective Floor Cavity Reflectance. 25 23 21 19 25 23 21 19 20 18 7 8 9 10 Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 ADP040649 2013-09-26 16:12:33