PORTFOLIO TM D ES C R IPTION Low brightness 4-1/2-inch aperture lensed reflector for use with 26W Triple Twin Tube compact fluorescent lamps. The deeply regressed lens provides superb shielding to eliminate brightness at higher angles. Choice of lenses for various aesthetics. Standard features include low iridescent finish on all reflector colors (to eliminate "rainbowing") and venting to ensure maximum lamp life and lumen output. The modular housing will also accept various downlight and wall wash reflectors. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S Re f l e c t o r Hous i ng Mountin g Frame S ock et .050 thick aluminum, in a one piece spun macrofocal parabolic contour. Available in a variety of Alzak® finishes. Also available with white or black baffle. Positive reflector mounting pulls trim tight to ceiling. One piece precision die cast aluminum 1-1/2" deep collar accommodates varying dimensions of ceiling materials. 4-pin GX24q3 base for C4026 with fatigue free stainless steel lamp spring ensures positive lamp retention. U ni v e rs a l Moun ting B racket Electron ic B allast Accepts 1/2" EMT, C Channel, T bar fasteners, and bar hangers. Adjusts 5" vertically from above or below ceiling. Electronic ballast provides full light output and rated lamp life. Provides flicker free and noise free operation and starting. End of lamp life protection is standard. Le n s Choice of tempered fresnel, prismatic, diffuse, or clear glass lenses or molded prismatic acrylic, opal diffuser or clear UV stabilized acrylic. Lens is fixed to lower reflector. Condui t F i tti ngs Die cast screw tight connectors. Labels cULus listed, standard wet label. J unc ti on Box Listed for eight #12AWG (four in, four out) 90°C conductors feed through branch wiring. 1/2" and two 3/4" pry outs. Positioned to allow straight conduit runs. Access to junction box by removing reflector. Trim Ring Options Self flanged or molded white trim ring. So c k e t C a p One piece vented and finned die cast aluminum cap for maximum thermal performance. C4026 4080/4081 26W TTT Compact Fluorescent STEPREPEAT> 4-Inch Lensed Downlight ENERGY DATA 26W TTT 4-pin Ballast: Electronic T o p V i ew 120V Input Watts: 29 Line Amps: 0.25 277V Input Watts: 29 Line Amps: 0.10 Power Factor: >0.99 THD: <10% Min. Starting Temperature: -10°C (15°F) Sound Rating: Class A Standards 10-1/16" [255mm] 8-7/8" [224mm] CP 9-3/8" [237mm] NOTES: Accessories should be ordered separately. For additional options, please consult your Cooper Lighting Representative. Alzak is a registered trademark of Aluminum Company of America. 10-1/4" [260mm] 12" [305mm] 4-1/2" [114mm] 5-1/8" [130mm] 13-3/8" [340mm] 5-3/4" [146mm] ( w i t h E M O p t i o n) Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. ADP051830 2014-07-24 09:03:00 C4026 4080/4081 ORDER ING INFOR M A TION EXAMPLE: C4026E 4080LI3G Housing Wa tt a ge Ballast Options CP=Chicago E=120/277V 50/60 Plenum Hz Electronic EM=Emergency 3E=347V 50/60 Hz Module with Electronic RemoteTest Switch D5LT=120-277V Fifth Light (DALI Dimming) 3D5LT=347V Fifth Light (DALI Dimming) D=120-277V Dimming Lutron EcoSystem/ 3-Wire Control (Factory Wired for 3-Wire) DMARKVII=26W120-277V Advance MARK 7 1DMARKX=26W 120V Advance MARK 10 2DMARKX=26W 277V Advance MARK 10 C40=4" CF Vertical 26=(1) 26W TTT Lamp Tri m s Finish 4081=Lensed Reflector, Self-Flanged 4080=Lensed Reflector, Molded Trim Ring Lens LI=Low Iridescent Clear 1=Prismatic Lens 2=Diffuse Lens H=Haze 3=Clear Lens WMH=Warm Haze 1G=Prismatic Glass G=Gold 2G=Diffuse Glass WH=Wheat 3G=Clear Glass W=Gloss White 4G=Fresnel Glass GP=Graphite GPH=Graphite Haze BB=Black Baffle (4080 only) WB=White Baffle (4080 only) Options A c c e s s o ri e s WF=White painted Flange (self Flanged only) HB26=C Channel Bar Hangers, 26" Long, Pair HB50=C Channel Bar Hangers, 50" Long, Pair FK5=5 Amp Field Installable Fuse Kit 300V Max RMB-22=Wood Joist Bar Hanger, 22" Long, Pair HSA4=Slope Adapter for 4" Aperture Housings, Specify Slope PH OTOM ETR IC S Candlepower Distribution Curve Downlight Cone of Light Spacing Criterion = 0.9 Efficiency = 24.3% 80° 70° 110 60° 50° 220 330 40° 10° 20° 30° Test No. H21335 C4026 4080LI4G Lamp = 26W TTT Distance Fixture to Lighted Plane 4'0" 6'0" 7'0" 8'0" 9’0" 10'0" Initial Footcandles at Nadir Beam Diameter 19 9 6 5 4 3 3'6" 5'6" 6'6" 7'6" 8'0" 9’0" Coefficients of Utilization Ceiling 80 % 70 % 50% Wall % 70 50 30 10 50 30 10 50 10 RCR Zonal cavity method -- floor reflectance = 20% 0 29 29 29 29 28 28 28 27 27 1 27 26 26 25 26 25 25 25 24 2 26 24 23 22 24 23 22 23 21 3 24 22 20 19 22 20 19 21 19 4 22 20 18 17 20 18 17 19 17 5 21 18 17 15 18 16 15 18 15 6 19 17 15 14 17 15 14 16 14 7 18 16 14 13 15 14 12 15 12 8 17 14 13 11 14 13 11 14 11 9 16 13 12 10 13 12 10 13 10 10 15 12 11 10 12 11 10 12 10 0° Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 ADP051830 2014-07-24 09:03:00