D ES C R IPTION
Low brightness 6-inch aperture open wall wash reflector for use with
26W or 32W Triple Twin Tube 4-pin lamps for below ceiling installation.
Available in single, double and corner wall wash versions. Standard
features include low iridescent finish on all reflectors, electronic ballasts
and venting to ensure maximum lamp life and lumen output. Optics
offer unparalleled performance with uniform illuminance on wall, no
flashback, and glare-free downlighting. Medium beam, wide beam,
lensed and open wall wash trims are interchangeable within the same
housing.
Type
Catalog #
Project
Date
Comments
Prepared by
SPE C IFIC A TION FEA T U R E S
Re f l e c t o r
Soc ke t Conne ctor
Electron ic B allast
Full spinning Gradient Kicker
provides high levels of vertical
illumination, protects reflector
integrity and achieves superior
sealed design. Airflow travels
through downlight cone neck
for optimum lamp cooling. One
piece spun Quiet Cone downlight
reflector of 0.50 thick aluminum,
available in a variety of Alzak®
finishes. Positive reflector
mounting pulls self-flanged trim
tight to ceiling.
One piece vented and finned die
cast aluminum cap for maximum
thermal performance.
Electronic ballast provides full
light output and rated lamp life.
Provides flicker free and noise free
operation and starting. End of lamp
life protection is standard.
Hous i ng Cons t ru ction
Galvanized steel plaster ring
accommodates up to 1" ceiling
thickness.
Labels
cULus listed, standard damp label.
Condui t F i tti ngs
Die cast screw tight connectors.
Soc ke t
C6RV042
C6IV042
60110/60111
60120/60121
4 pin G24q-2 base with fatigue free
stainless steel lamp spring ensures
positive lamp retention.
Trim Ring Options
Self flanged reflector is standard.
Painted white flange (WF) option is
available.
26W or 32W
TTT or PLT
Compact Fluorescent
STEPREPEAT>
8-1/2"
[214mm]
6-Inch Remodel/International
Vertical Open Wall Wash
8-1/2"
[214mm]
Adjustable
ENERGY DATA
26W TTT 4-pin
Ballast: Electronic
5-1/2" [140mm]
6-3/8" [162mm]
6-15/16" [176mm]
5-1/2" [140mm]
6-3/8" [162mm]
REMODEL
6-15/16" [176mm]
INTERNATIONAL
120V Input Watts: 29
Line Amps: 0.25
277V Input Watts: 26
Line Amps: 0.09
Power Factor: >0.99
THD: <90%
Min. Starting Temperature: -10°C (15°F)
Sound Rating: Class A Standards
32W TTT 4-pin
Ballast: Electronic
11-1/4"
[287mm]
12-3/8 [316mm]
11-1/4"
[287mm]
Adjustable
Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.
120V Input Watts: 36
Line Amps: 0.32
277V Input Watts: 36
Line Amps: 0.16
Power Factor: >0.99
THD: <10%
Min. Starting Temperature: -10°C (10°F)
Sound Rating: Class A Standards
NOTES: Accessories should be ordered separately. For additional
options, please consult your Cooper Lighting Representative.
Alzak is a registered trademark of Aluminum Company of
America.
ADP110875
2014-08-18 09:01:48
ORDER IN G INFOR M A TION
C6RV042 C6IV042 60110/60111 60120/60121
EXAMPLE: C6RV042ECP 60111LI WF=6" CFL Vertical Single Wall Wash with Gradient Kicker, (1) 26/32 Watt TTT lamp with 120/277 Volt, Chicago Plenum, Self Flanged with Specular Clear Finish
Housing
C6RV042=6" CFL
Vertical
Remodel,
(1) 26W TTT
(1) 32W TTT or PLT
C6IV042=6"
CFL Vertical
International,
(1) 26W TTT
(1) 32W TTT or PLT
Ballast
Options
R e fl e c to r
EM=Emergency Module
E=120/277V 50/60 Hz Electronic
with RemoteTest Switch
3E=347V 50/60 Hz Electronic
D5LT26=26W 120-277V Fifth Light
(DALI Dimming)
D5LT32=32W 120-277V Fifth Light
(DALI Dimming)
3D5LT26/32=26 or 32W 347V Fifth Light
(DALI Dimming)
D26/32=26 or 32W 120-277V Dimming Lutron
EcoSystem/3-Wire Control (Factory Wired for 3-Wire)
D26MARKVII=26W 120-277V Advance MARK7
D32MARKVII=32W 120-277V Advance MARK7
D42MARKVII=42W 120-277V Advance MARK7
1D26MARKX=26W 120V Advance MARK 10
1D32MARKX=32W 120V Advance MARK 10
1D42MARKX=42W 120V Advance MARK 10
2D26MARKX=26W 277V Advance MARK 10
2D32MARKX=32W 277V Advance MARK 10
2D422MARKX=42W 277V Advance MARK 10
Options
Finish
LI=Specular Clear
H=Semi-Specular
Clear
WMH=Warm Haze
G=Specular Gold
WH=Wheat
W=Gloss White
GP=Graphite
GPH=Graphite Haze
B=Specular Black
W=Gloss White
60111=Single WW,
Self Flanged
60110=Single WW,
Polymer Trim Ring
60121=Double WW,
Self Flanged
60120=Double WW,
Polymer Trim Ring
60131=Corner WW,
Self Flanged
60130=Corner WW,
Polymer Trim Ring
A c c e s s o ri e s
TRM6=Metal Trim
Ring, Specify Finish 1
TRR6=Rimless Trim
Ring, White 1
ABR6P=Remodel
Adaptor Ring for 7˝ OD
ABR7P=Remodel
Adaptor Ring for 8˝ OD
ABR8P=Remodel
Adaptor Ring for 9˝ OD
WF=White
painted
Flange (Self
Flanged only)
Notes: 1 Order trim with polymer trim ring
(Consult specification sheet for ordering information and options).
PH OTOM ETR IC S
Candela Distribution
Candlepower Distribution Curve
Wall Washer (0°)
Downlight (180°)
C6RV042 60111
80°
80°
70°
70°
300
60°
50°
Degrees
Vertical
0
5
15
25
35
45
55
65
75
85
90
60°
Test No. 247P124
50°
Efficiency = 41.8%
Lamp = 32W TTT
600
40°
30°
20°
10°
Spacing Criterion = 1.1
40°
900
10°
20°
2'
3
7
8
7
5
4
3
2
2
1
3'
1
3
4
4
4
3
2
2
1
1
45
55
65
75
85
CD/SQ M
0°
180°
28315 11806
20012 1364
14042
154
9827
0
4490
0
3' from wall
2'6" from wall
(single fixture)
1'
8
14
13
10
7
5
3
2
2
1
180°
749
723
644
426
250
128
12
1
0
0
0
Multiple Unit Footcandles
Distance from wall
12
19
16
11
8
5
4
3
2
1
Degrees
0°
749
815
781
614
453
307
176
91
39
6
0
30°
Single Unit Footcandles
DD
1
2
3
4
5
6
7
8
9
10
Luminance
(spacing between fixtures)
4'
1
1
2
2
2
2
2
1
1
1
5'
0
1
1
1
1
1
1
1
1
1
6'
0
0
1
1
1
1
1
1
1
1
14
25
25
20
15
12
9
7
5
4
3'
11
22
24
20
15
12
9
7
5
4
14
25
25
20
15
12
9
7
5
4
12
21
20
16
12
9
7
6
4
3
4'
7
15
17
15
12
9
7
6
4
3
12
21
21
16
12
9
7
6
4
3
(spacing between fixtures)
9
18
21
19
16
13
10
8
6
5
4'
8
17
21
19
16
13
10
8
6
5
9
18
21
19
16
13
10
8
6
5
7
14
17
15
12
10
8
6
5
4
6'
5
12
15
14
12
10
8
6
5
4
7
14
17
15
12
10
8
6
5
4
Notes:
• Illuminance values for multiple fixtures are based upon the center two units of a four unit array. Footcandle values are
centerline of fixtures and centered between fixtures.
• Illuminance values are cosine corrected initial values with no contribution from inter reflections from other room
surfaces. Total illumination may increase from contributions from other surfaces.
• Changing fixture spacing will affect illuminance level.
Existing Spacing
New Fc = New Spacing x Average Table Fc Level
• When selecting colored cones option, only downlight cone is colored; the wall wash reflector is specular clear. This
allows the color (CRI, °K) of the light source to be unaffected and maximizes lumen output.
Distance
From Wall
Spacing Between
Fixtures
DD=Distance Down
From Ceiling
CL
Specifications and dimensions subject to change without notice.
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801