PORTFOLIO TM D ES C R IPTION Recessed concave prismatic lens downlight with 13 inch aperture for vertical ED17 medium base metal halide lamp. Electronic ballast features end of life shutdown. Fixture is suitable for commercial construction. Insulation must be kept 3” from top and sides of housing. Universal housing also accepts regressed Fresnel and regressed prismatic lens trims. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S Pla s t e r F r a m e / Col l a r Shi e l di ng Extruded aluminum collar accommodates ceiling materials up to 1-7/8” thick. Molded concave prismatic clear glass lens is retained during lamp replacement. Extruded aluminum step baffle with gasket eliminates light leaks. C on d u i t F i t t i n g s Die cast aluminum conduit fittings secure flex to socket housing and junction box. U n i v e r s a l M o u n t ing Bra c ke t Accepts ½” EMT, C channel and bar hangers and adjusts 5” vertically from above the ceiling. Tri m Re te nti on Trim is retained with two torsion springs holding the flange tightly to the finished ceiling surface. Soc ke t Pulse rated E26 medium base socket accepts unprotected lamps. Ju n c t i o n B o x (6) ½” and (2) ¾” trade size pry outs positioned to allow straight conduit runs. Listed for (8) #12 AWG (six in, six out) 90°C conductors and feed thru branch wiring. Upper Reflector Spun 0.050” thick aluminum reflector with a specular clear Alzak® finish. Reflector can be removed from below the ceiling to access ballast and junction box. 12 9/16” [319mm] I ns ul a ti on D e tector Self resetting detector opens circuit if insulation is improperly installed. Ba l l a s t Electronic ballast provides noise free operation, improved efficiency and increased lamp life as compared with magnetic ballast. Regulated output power over a wide range of ANSI lamp voltages results in excellent color stability over time. End of lamp life shutdown – reset power to restore output. Qu artz Lamp R e-strike (Q Op tion ) Internal auxiliary 100W DC bayonet base T4 quartz lamp (included) provides low level illumination in the event of a momentary power interruption. Emergen cy Circuit Lamp (X Op tion ) Emergency circuit lamp module for 100W DC bayonet base T4 quartz lamp (included) by emergency circuit. ML13150 Co d e Co mplian ce Thermally protected and cULus listed for protected wet locations. Optional City of Chicago environmental air (CCEA) marking for plenum applications. EMI/RFI emissions per FCC 47CFR Part 18 non consumer limits. 10212 Metal Halide ED17 STEPREPEAT> 13-Inch Concave Prismatic Lens Downlight OPTIONAL Q 9 1/8” [232mm] T OP V IE W 13 1/8” [333mm] 13 13/16” [351mm] 20 5/8” [524mm] ENERGY DATA 14 1/2” [368mm] 150W 20 1/2” [520mm] 120V Input Power: 165W 277V Input Power: 161W 120V Input Current: 1.38A 277V Input Current: 0.59A Minimum Starting Temp: -30°C, -20°F THD: <20% Power Factor: >0.90 Sound Rating: A Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. ADP090859 2013-09-30 13:33:28 ML13150 10212 ORDER ING INFOR M A TION S A M P L E N U M B E R : 1 3 1 5 0 1 E = 13” housing with 120V electronic ballast for a 150W ED17 MH lamp 1 0 2 1 2 P = 13” concave prismatic lens, white trim ring, black baffle (Order universal housing and trim separately) Housing Wattage ML13=13” lens MH housing ML13CP=13” lens MH housing, CCEA listed for City of Chicago plenum requirements 150=150W MH lamp Options Ballast Trim Options Accessories 1E=Electronic, 120V 50/60Hz 2E=Electronic, 277V 50/60Hz P=White trim ring black baffle PWH=White trim ring, white baffle Q=Quartz re-strike system X= Emergency circuit lamp HB26=Bar hanger, 26” long, pair HB50=Bar hanger, 50” long, pair RMB22=Bar hanger for wooden joists, 22” long, pair H347200=347V stepdown transformer, 200VA 10212=13” concave prismatic lens PH OTOM ETR IC S Candlepower Distribution Curve Downlight Cone of Light Spacing Criteria = 0.7 Efficiency = 53.0% Distance Fixture to Lighted Plane Initial Footcandles at Nadir Beam Diameter Test No. P12077 ML13150 10212P Lamp = MH150/C/U/M 150 Watts 10'0" 13'0" 16'0" 20'0" 25'0" 65 39 26 16 10 11'0" 14'0" 17'0" 21'5" 27'0" 80° 2500 70° 60° 50° 5000 40° 7500 10° 20° 30° 150W ED17 Coefficients of Utilization Ceiling 80% 70% 50% 50 30 10 50 10 Wall % 70 50 30 10 RCR Zonal cavity method -- floor reflectance = 20% 75 75 75 75 74 74 74 70 70 0 72 70 68 66 68 67 65 66 63 1 68 64 61 59 63 60 58 61 57 2 64 59 56 53 58 55 53 57 52 3 60 55 51 48 54 51 48 53 47 4 57 51 47 44 50 46 44 49 43 5 54 47 43 40 47 43 40 46 40 6 51 44 40 37 44 40 37 43 37 7 48 41 37 34 41 37 34 40 34 8 45 39 35 32 38 34 32 38 32 9 43 36 32 30 36 32 30 36 30 10 Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 ADP090859 2013-09-30 13:33:28