PORTFOLIO

advertisement
PORTFOLIO TM
D ES C R IPTION
Recessed concave prismatic lens downlight with 13 inch aperture for
vertical ED17 medium base metal halide lamp. Electronic ballast features
end of life shutdown. Fixture is suitable for commercial construction.
Insulation must be kept 3” from top and sides of housing. Universal
housing also accepts regressed Fresnel and regressed prismatic lens
trims.
Type
Catalog #
Project
Date
Comments
Prepared by
SPE C IFIC A TION FEA T U R E S
Pla s t e r F r a m e / Col l a r
Shi e l di ng
Extruded aluminum collar
accommodates ceiling materials up
to 1-7/8” thick.
Molded concave prismatic clear
glass lens is retained during lamp
replacement. Extruded aluminum
step baffle with gasket eliminates
light leaks.
C on d u i t F i t t i n g s
Die cast aluminum conduit fittings
secure flex to socket housing and
junction box.
U n i v e r s a l M o u n t ing Bra c ke t
Accepts ½” EMT, C channel
and bar hangers and adjusts 5”
vertically from above the ceiling.
Tri m Re te nti on
Trim is retained with two torsion
springs holding the flange tightly
to the finished ceiling surface.
Soc ke t
Pulse rated E26 medium base
socket accepts unprotected lamps.
Ju n c t i o n B o x
(6) ½” and (2) ¾” trade size pry
outs positioned to allow straight
conduit runs. Listed for (8)
#12 AWG (six in, six out) 90°C
conductors and feed thru branch
wiring.
Upper Reflector
Spun 0.050” thick aluminum
reflector with a specular clear
Alzak® finish. Reflector can be
removed from below the ceiling to
access ballast and junction box.
12 9/16”
[319mm]
I ns ul a ti on D e tector
Self resetting detector opens circuit
if insulation is improperly installed.
Ba l l a s t
Electronic ballast provides
noise free operation, improved
efficiency and increased lamp
life as compared with magnetic
ballast. Regulated output power
over a wide range of ANSI lamp
voltages results in excellent color
stability over time. End of lamp life
shutdown – reset power to restore
output.
Qu artz Lamp R e-strike (Q
Op tion )
Internal auxiliary 100W DC bayonet
base T4 quartz lamp (included)
provides low level illumination in
the event of a momentary power
interruption.
Emergen cy Circuit Lamp (X
Op tion )
Emergency circuit lamp module for
100W DC bayonet base T4 quartz
lamp (included) by emergency
circuit.
ML13150
Co d e Co mplian ce
Thermally protected and cULus
listed for protected wet locations.
Optional City of Chicago
environmental air (CCEA) marking
for plenum applications. EMI/RFI
emissions per FCC 47CFR Part 18
non consumer limits.
10212
Metal Halide
ED17
STEPREPEAT>
13-Inch
Concave Prismatic
Lens Downlight
OPTIONAL Q
9 1/8”
[232mm]
T OP V IE W
13 1/8”
[333mm]
13 13/16”
[351mm]
20 5/8”
[524mm]
ENERGY DATA
14 1/2”
[368mm]
150W
20 1/2”
[520mm]
120V Input Power: 165W
277V Input Power: 161W
120V Input Current: 1.38A
277V Input Current: 0.59A
Minimum Starting Temp: -30°C, -20°F
THD: <20%
Power Factor: >0.90
Sound Rating: A
Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADP090859
2013-09-30 13:33:28
ML13150 10212
ORDER ING INFOR M A TION
S A M P L E N U M B E R : 1 3 1 5 0 1 E = 13” housing with 120V electronic ballast for a 150W ED17 MH lamp
1 0 2 1 2 P = 13” concave prismatic lens, white trim ring, black baffle (Order universal housing and trim separately)
Housing
Wattage
ML13=13” lens MH housing
ML13CP=13” lens MH housing, CCEA listed
for City of Chicago plenum requirements
150=150W MH lamp
Options
Ballast
Trim
Options
Accessories
1E=Electronic, 120V 50/60Hz
2E=Electronic, 277V 50/60Hz
P=White trim ring black baffle
PWH=White trim ring, white baffle
Q=Quartz re-strike system
X= Emergency circuit lamp
HB26=Bar hanger, 26” long, pair
HB50=Bar hanger, 50” long, pair
RMB22=Bar hanger for wooden joists, 22” long, pair
H347200=347V stepdown transformer, 200VA
10212=13” concave prismatic lens
PH OTOM ETR IC S
Candlepower Distribution Curve
Downlight
Cone of Light
Spacing Criteria = 0.7
Efficiency = 53.0%
Distance
Fixture to
Lighted Plane
Initial
Footcandles
at Nadir
Beam
Diameter
Test No. P12077
ML13150 10212P
Lamp = MH150/C/U/M
150 Watts
10'0"
13'0"
16'0"
20'0"
25'0"
65
39
26
16
10
11'0"
14'0"
17'0"
21'5"
27'0"
80°
2500
70°
60°
50°
5000
40°
7500
10°
20°
30°
150W
ED17
Coefficients of Utilization
Ceiling
80%
70%
50%
50 30 10
50 10
Wall % 70 50 30 10
RCR Zonal cavity method -- floor reflectance = 20%
75 75 75 75
74 74 74
70 70
0
72 70 68 66
68 67 65
66 63
1
68 64 61 59
63 60 58
61 57
2
64 59 56 53
58 55 53
57 52
3
60 55 51 48
54 51 48
53 47
4
57 51 47 44
50 46 44
49 43
5
54 47 43 40
47 43 40
46 40
6
51 44 40 37
44 40 37
43 37
7
48 41 37 34
41 37 34
40 34
8
45 39 35 32
38 34 32
38 32
9
43 36 32 30
36 32 30
36 30
10
Specifications and dimensions subject to change without notice.
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801
ADP090859
2013-09-30 13:33:28