INSTALLATION INSTRUCTIONS V90200 ACCURUS ROUND REMODEL ACT954,ACT974 & ACM504 SERIES Avoid Fire or Electric Shock Sheet 1 of 1 *Installation Instructions for qualified electricians only. *Install per National Electrical Code and local regulations. *Read Installation Instructions completely before installation. *Failure to follow Installation Instructions may void warranties. *Fixtures to be wired as follows: Black wire to incoming line voltage; White wire to common; Green wire to building ground. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. Pre -Installation Preparation: 1. ACT954 Series 5.5 inch ACT974 Series 7.5 inch ACM514 Series 5.5 inch Ceiling Cutout Ceiling Remodel Housing Thermal Protector Support Clips Figure 1 Check for Above Ceiling Clearance(marked as"X" in Figure 2) of following: 2. Cut an opening of 4-3/16 inch round in ceiling. Electrical Connection: 3. Turn off all electrical services. 4. All appropriate "rough" wiring should be completed. 5. Get wire from ceiling.Connect wiring inside the JBox to existing service through knockouts provided. Housing Installation: Knock out 6. Junction Box Install housing above ceiling: a) adjust suitable height of the weight supporter on transformer (Magnetic Only). Both Figure 1 & 2 shows non-magnetic. X Above Ceiling Clearance b)turn and insert junction box through the opening. c) Push the housing straight up against opening d) push clip through housing slot and lock in place; fit clip on side of transformer first to assure proper holding on the weight. Figure 2 7. Install lamp into lamp holder 8. Install lamp into trim, then trim into housing.