Specification grade A lamp fixture rated for direct

advertisement
C AT A L O G # :
TYPE:
DESCRIPTION
Specification grade A lamp fixture rated for direct
contact with insulation. The 50° cutoff to lamp
and lamp image provides a glare-free, smooth,
medium beam distribution. Use with narrow joist
spacing. Insulation must be kept 3" from fixture
sides and top of fixture. Lamp module and optical element can be changed after installation to provide a variety of lamp sources
and distributions. e.g. into a low voltage
Adjustable
5 1/4"
E
D
PN5
M120
E5A19BB
F
H
C
G
A
100W A19
100W BT15
100W MB19
5 1/4"
[134mm]
6 1/4"
[159mm]
6 3/4"
[172mm]
B
Incandescent
5" DOWNLIGHT
BAFFLE
S P E C I F I C AT I O N F E AT U R E S
A ...Baffle
F ...Frame/Housing
.040 thick aluminum spun parabolic upper and
sawtooth lower baffle. Upper reflector is specular
clear, lower baffle is available in Black or White.
Other options available upon request.
Hot dipped galvanized 20 gauge steel frame
with built in 1/2 inch plaster lip. Gunsights allow
for consistent alignment. One piece 20 gauge steel
housing for seamless construction is painted
matte black for a visually dark interior.
B ...Flange
Die-cast flange with either matte white or clear
coat finish. Die-cast flanges are easily removed
for field painting. Elements are keyed for proper
insertion.
G ...Junction Box
C ...Attachment
H ...Bar Hangers
Positive torsion springs pull flange tight to
ceiling. Mechanical light trap eliminates spill light
at edge of flange or reflector.
No Flex® bar hangers with positive locking, for
use with wood, engineered wood and steel frame
joists spaced up to 24" O.C. ship with platform.
For use in T-bar ceilings order accessory MBCLP.
Nailess barb and locator lip provide consistent
installation height.
18 cubic inches, listed for 4#12 AWG or 6#14 AWG
90° C additional feed through conductors, has five
1/2 inch pryouts.
D ...Socket
Nickel plated porcelain socket. Fixed socket height
ensures consistent lamp position.
8 1/2"
[216mm]
16 1/2"
[419mm]
4 15/16"
[126mm]
8 1/2"
[216mm]
Ceiling Cutout
6 1/4" [159mm]
Codes
E ...Electrical
Thermally protected, IP labeled. Unit is airtight
and exchanges less than 2.0 CFM with the plenum
at apressure of 75 pascals. Insulation must be kept
three inches away from fixture sides and none on
top as to entrap heat.
Keyed quick connect provides easy lamp module
installation.
Labels
UL listed, CSA certified, standard damp label,
IBEW union made.
O R D E R I N G I N F O R M AT I O N
Complete unit consists of a platform, module and element.
Platform
Lamp
Module
PN5
M120
PN5 = 5"
Non-IC
Housing
M120 = 120V
Medium
Base Socket
COOPER LIGHTING
Optical
Element
E5A19 = 5"
A Lamp
Downlight
Relector
Finish
Flange
BB = Black
Baffle
WB = White
Baffle
Blank= White
die-cast
RAW= Natural
Die-cast
Accessories
MBCLP =40 Push On T
Bar Clips (for 10 Units)
PLE5 = Plaster Lip
Extension for Max 2"
Thick Ceiling
FMC5 = Flush Mount
Collar
ADI033033
Unit Number: P N 5 - M 1 2 0 - E 5 A 1 9 B B
PHOTOMETRICS
PN5-M120-E519C
Candelas
Test No.
Vertical
Angle
90
85
75
65
55
45
35
25
15
5
0
H36062
Lamp:
100A19/IF
Lumens:
1720
Cutoff:
Spacing:
Efficiency:
Unit LPW:
50°
1.0
70.9%
12.2
Distribution
Luminance
CD
0
0
0
0
0
201
598
784
842
1049
1102
Cone of Light
cd/m2
0
Degree
85˚
75˚
0
65˚
0
55˚
0
45˚
20346
Distance to
Illuminated Plane
Initial Nadir
Footcandles
Beam
Diameter
54
36
26
17
11
8
4'6"
5'6"
6'6"
8'0"
10'0"
12'0"
6'0"
7'0"
8'6"
10'6"
13'0"
15'6"
Lamp Wattage Multiplier
75W x 0.68
60W x 0.50
0°
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-180
0-180
Lumens
699
1060
1220
1222
0
1222
%Lamp
40.6
61.6
71.0
71.1
0.0
71.1
Coefficient of Utilization
%Luminaire
57.2
86.7
99.8
100.0
0.0
100.0
PN5-M120-E519C
Candelas
Test No.
Vertical
Angle
90
85
75
65
55
45
35
25
15
5
0
H36098
Lamp:
100BT15/
HAL/SW
1880
Lumens:
Cutoff:
Spacing:
Efficiency:
Unit LPW:
50°
0.9
57.3%
10.8
Ceiling Reflectance
Wall Reflectance
Room Cavity Ratio
0
1
2
3
4
5
6
7
8
9
10
70
50
80%
30
10
50
10
50
10
50
10
0%
0
85
81
77
74
70
67
85
79
74
69
65
61
85
77
71
66
61
57
85
76
69
63
59
54
83
77
73
68
64
60
83
75
68
63
58
54
79
75
71
67
63
59
79
72
67
62
58
53
76
72
68
65
61
58
76
70
65
61
57
53
71
67
63
59
55
51
63
60
56
53
50
57
53
50
46
43
53
49
45
42
39
50
46
43
39
36
57
53
49
46
43
50
46
42
39
36
56
52
48
45
42
50
46
42
39
36
55
51
48
44
41
49
46
42
39
36
48
44
41
38
35
Distribution
70%
Luminance
CD
0
0
0
1
2
145
418
760
953
1075
1078
30%
Cone of Light
cd/m2
0
Degree
85˚
50%
75˚
0
65˚
169
55˚
250
45˚
14677
Distance to
Illuminated Plane
Initial Nadir
Footcandles
Beam
Diameter
53
36
26
17
11
8
4'6"
5'6"
6'6"
8'0"
10'0"
12'0"
4'6"
5'6"
6'0"
7'6"
9'6"
11'6"
Lamp Wattage Multiplier
75W x 0.70
0°
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-180
0-180
Lumens
717
975
1077
1078
0
1078
%Lamp
38.1
51.8
57.3
57.3
0.0
57.3
Coefficient of Utilization
%Luminaire
66.5
90.4
99.9
100.0
0.0
100.0
Ceiling Reflectance
Wall Reflectance
Room Cavity Ratio
0
1
2
3
4
5
6
7
8
9
10
70
50
80%
30
10
50
70%
10
50
50%
10
50
30%
10
0%
0
68
65
63
60
58
55
53
50
48
68
64
60
57
54
51
48
45
43
68
63
58
55
51
48
45
42
40
68
62
57
53
49
46
43
40
37
67
63
59
56
53
50
48
45
42
67
61
56
52
49
46
43
40
37
64
61
58
55
52
49
47
44
42
64
59
55
51
48
45
43
40
37
61
58
56
53
51
48
46
44
41
61
57
54
51
48
45
42
40
37
57
54
52
49
46
44
41
39
36
45
43
40
38
37
35
35
33
40
38
35
33
39
37
35
33
39
37
35
32
34
32
Notes and Formulas:
Luminance: To convert cd/m2 to footlamberts, multiply by 0.2919
Cone of Light:
• Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
• Footcandle values are initial. Apply appropriate light loss factors where necessary.
CU Notes/Formulas:
• maintained illuminance=lamp lumens x CU x light loss factors
room area
• total number of luminaires=total room area x maintained illuminance
lamp lumens x CU x light loss factors
• CU data based on 20% effective floor cavity reflectance.
Note: Specifications and Dimensions subject to change without notice.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801 ADI033033
Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049