Specification grade PAR30 fixture for use with nar- Lamp module

advertisement
C AT A L O G # :
TYPE:
DESCRIPTION
Specification grade PAR30 fixture for use with narrow joist spacing. Insulation must be kept 3" from
fixture sides and top of fixture. The 50° cutoff to
lamp and lamp image provides a glare-free,
smooth, medium beam distribution. Lamp module
and optical element can be changed after installation to provide a variety of lamp sources and
distributions. e.g. into a PAR36 Adjustable.
5 1/4"
G
D
F
PN5
M120
E5P30BB
C
A
E
75W PAR30
75W PAR30L
85 BR30
H
5 1/4"
[134mm]
6 1/4"
[159mm]
B
100R30
5" DOWNLIGHT
BAFFLE
6 3/4"
[172mm]
S P E C I F I C AT I O N F E AT U R E S
A ...Baffle
G ...Frame/Housing
.040 thick aluminum spun sawtooth baffle in
matte black or white powdercoat finish. Baffle
extends up beyond lamp for clean appearance.
Hot dipped galvanized 20 gauge steel frame with
built in 1/2 inch plaster lip. Gunsights allow for
consistent alignment. One piece 20 gauge steel
housing for seamless construction is painted
matte black for a visually dark interior.
B ...Flange
Die-cast flange with either matte white or clear
coat finish. Die-cast flanges are easily removed
for field painting. Elements are keyed for proper
insertion.
8 1/2"
[216mm]
H ...Bar Hangers
C ...Attachment
Positive torsion springs pull flange tight to
ceiling. Mechanical light trap eliminates spill light
at edge of flange or baffle.
No Flex® bar hangers with positive locking, for use
with wood, engineered wood and steel frame
joists spaced up to 24" O.C. ship with platform.
For use in T-bar ceilings order accessory MBCLP.
Nailess barb and locator lip provide consistent
installation height.
16 1/2"
[419mm]
4 15/16"
[126mm]
8 1/2"
[216mm]
Ceiling Cutout
6 1/4" [159mm]
Codes
D ...Socket
Nickel plated porcelain socket. Two position socket
ensures consistent lamp position.
E ...Electrical
Keyed quick connect provides easy lamp module
installation.
Thermally protected, IP labeled, Unit is airtight
and exchanges less than 2.0 CFM with the plenum
at a pressure of 75 pascals. Insulation must be
kept three inches away from fixture sides and
none on top as to entrap heat.
Labels
F ...Junction Box
18 cubic inches, listed for 4#12 AWG or 6#14 AWG
90° C additional feed through conductors, has five
1/2 inch pryouts.
UL and cUL listed, standard damp label,
IBEW union made.
O R D E R I N G I N F O R M AT I O N
Complete unit consists of a platform, module and element
Platform
PN5
PN5=5"
Airtight non IC
Housing
Lamp Module Element
Finish
Flange
Accessories
M120
M120=Medium
Base
Incandescent
Socket
COOPER LIGHTING
E5P30=5"
PAR 30
Downlight
Baffle
BB=Black Baffle
WB=White Baffle
Blank=White
Die-cast
RAW=Natural
Die-cast
MBCLP=40 Push On T Bar
Clips (for 10 Units)
PLE5=Plaster Lip Extension
for Max 2" Thick Ceiling
FMC5=Flush Mount Collar
For additional options please consult factory.
ADI030689
Unit Number: P N 5 - M 1 2 0 - E 5 P 3 0 B B
PHOTOMETRICS
PN5-M120-E5P30BB
Candelas
Test No.
Vertical
Angle
90
85
75
65
55
45
35
25
15
5
0
H36110
Lamp: 75PAR30FL/H
Lumens:
1100
Cutoff:
Spacing:
Efficiency:
Unit LPW:
50°
0.5
69.0%
10.1
Distribution
Luminance
CD
0
0
0
1
2
4
27
269
1502
2096
2303
Cone of Light
cd/m2
0
Degree
85˚
75˚
0
65˚
169
55˚
250
45˚
405
Distance to
Illuminated Plane
Initial Nadir
Footcandles
Beam
Diameter
113
76
54
36
23
16
4'6"
5'6"
6'6"
8'0"
10'0"
12'0"
2'6"
3'0"
4'0"
4'6"
6'0"
7'0"
0°
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-180
0-180
Lumens
735
754
759
760
0
760
%Lamp
66.8
68.6
69.0
69.0
0.0
69.0
Coefficient of Utilization
%Luminaire
96.8
99.3
99.9
100.0
0.0
100.0
PN5-M120-E5P30WB
Candelas
Test No.
Vertical
Angle
90
85
75
65
55
45
35
25
15
5
0
H36111
Lamp: 75PAR30FL/H
Lumens:
1100
Cutoff:
Spacing:
Efficiency:
Unit LPW:
50°
0.6
79.5%
11.6
Ceiling Reflectance
Wall Reflectance
Room Cavity Ratio
0
1
2
3
4
5
6
7
8
9
10
70
50
80%
30
10
50
10
50
10
50
10
0%
0
82
80
78
76
82
79
76
763
82
77
74
71
82
76
72
70
80
77
74
72
80
75
72
69
77
74
72
71
77
73
70
68
73
72
70
69
73
71
69
67
69
68
66
65
74
72
71
69
68
66
65
71
69
67
66
64
63
61
69
67
65
63
62
60
59
67
65
63
62
60
59
57
70
68
67
65
64
62
61
67
65
63
62
60
59
57
69
67
66
65
63
62
61
66
64
63
61
60
58
57
68
66
65
64
63
61
60
65
64
62
61
60
58
57
64
62
61
60
59
58
56
Distribution
70%
Luminance
CD
0
2
8
15
23
33
60
321
1522
2139
2268
30%
Cone of Light
cd/m2
1642
Degree
85˚
50%
75˚
2212
65˚
2540
55˚
2870
45˚
3340
Distance to
Illuminated Plane
Initial Nadir
Footcandles
Beam
Diameter
112
75
54
35
23
16
4'6"
5'6"
6'6"
8'0"
10'0"
12'0"
2'6"
3'6"
4'0"
5'0"
6'0"
7'6"
0°
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-180
0-180
Lumens
763
802
848
875
0
875
%Lamp
69.3
72.9
77.1
79.5
0.0
79.5
Coefficient of Utilization
%Luminaire
87.2
91.7
97.0
100.0
0.0
100.0
Ceiling Reflectance
Wall Reflectance
Room Cavity Ratio
0
1
2
3
4
5
6
7
8
9
10
70
50
80%
30
10
50
70%
10
50
50%
10
50
30%
10
0%
0
95
95
95
95
93
93
88
88
85
85
80
91
88
86
83
80
78
76
74
72
70
90
85
82
79
76
73
71
69
67
65
88
83
79
76
72
70
68
66
64
62
87
81
77
73
70
68
65
63
61
60
88
84
81
78
75
73
71
68
67
65
85
80
76
73
70
68
65
63
61
60
85
81
79
76
74
72
70
68
66
64
83
78
75
72
69
67
65
63
61
60
82
79
77
75
73
71
69
67
65
64
80
76
74
71
69
67
65
63
61
59
76
74
72
69
67
65
63
62
60
59
Notes and Formulas:
Luminance: To convert cd/m2 to footlamberts, multiply by 0.2919
Cone of Light:
• Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
• Footcandle values are initial. Apply appropriate light loss factors where necessary.
See page 64-65 of catalog.
CU Notes/Formulas:
• maintained illuminance=lamp lumens x CU x light loss factors
room area
• total number of luminaires=total room area x maintained illuminance
lamp lumens x CU x light loss factors
• CU data based on 20% effective floor cavity reflectance.
Note: Specifications and Dimensions subject to change without notice.