CORELITE DESCRIPTION The Corelite Class R2R Retrofit is designed to replace the core "lighting engine" of dated and inefficient recessed luminaires, while leaving the existing metal luminaire body intact. The total watts per luminaire can be reduced between 30 and 40 percent while improving the overall lighting quality and visual character of the interior space. The Class R2R is extremely low in profile with a 3" overall height, allowing for retrofit of shallow 3" lensed troffers. In addition to the energy cost reduction and improved lighting conditions, the Class R2R's 80%+ luminaire efficiency meets the requirements of many major rebate programs across the US. Type Catalog # Project Date Comments Prepared by SPECIFICATION FEATURES Construction Three-piece retrofit assembly consists of a ballast/bracket assembly, reflector and lens. Ballast/bracket assembly and reflector each have captive zinc-plated self-drilling hardware. Mounting brackets are pre-paint white 20-gauge die-formed steel. Reflector is one piece die-formed aluminum with a matte white powder coat painted finish. Ballast is pre-wired to factory installed sockets on each mounting bracket with the ballast/bracket assembly. 3" low-profile assembly will retrofit into both parabolics and troffers. Finish Reflector is matte white powder coat painted finish. Ballast brackets are pre-paint white with white semi-gloss finish. Electrical Ballast is fully tested and pre-wired to factory installed sockets within the ballast/bracket assembly, and comes with captive self-drilling hardware and integral quick disconnects. T5/T5HO fixtures use UL listed Class P, T5/T5HO program rapid start universal voltage electronic ballasts, with pre-installed quick disconnect. Standard Ballast Factor of 1.0 and Power Factor of 98%. Mounting First, existing lamps, reflectors, lenses, ballast covers, ballast and socket trays must be removed from existing luminaire. Next, the ballast/bracket assembly is installed by first mounting the ballast to the top of the existing luminaire, then by attaching the mounting brackets. The reflector then mounts to the ballast/bracket assembly, and finally lamps and lenses are installed. Shielding Luminaire lens is UV resistant acrylic with an optically designed prism structure, which diffuses lamp image and provides high light transmission and luminaire efficiency (80%+). NOTE: Fit Compatibility Retrofit kit fits most troffers. The end-user is responsible for verifying fit. Therefore, a sample kit is highly recommended. CLASS R2R Retrofit Lensed 3T5 3T5HO 2'x2' Recessed Retrofit Existing Recessed Luminiare* 3-1/8” [79mm] min 3” [76mm] 24” [610mm] ORDERING INFORMATION Sample Number: R2R-WL-3T5-1C-UNV-22-T1 Series R2R=Class R2R Retrofit Reflector W=White Shielding L=Linear Prismatic Lens Number of Lamps 3=3 Lamps Lamp Type N5=T5 Normal Output T5=T5 High Output Number of Circuits 1=1 Circuit 1 2=2 Circuits Wiring 1 C=Standard Circuit Voltage 1 120=120V D=Dimming / Step Dimming 277=277V 347=347V E=Emergency T=Nightlight Size 22=2' x 2' Ceiling Type T1=1" Grid2 UNV=Universal (120V-277V) Y=Daylight Notes: 1 2 Not all options available. Please consult your Cooper Lighting Representative for availability. Ceiling Type T1 is for flush ceilings only. Consult factory for all other ceiling types. Specifications and Dimensions subject to change without notice. Consult your representative for additional options and finishes. ADE100074 09/26/2012 1:55:54 PM Corelite PHOTOMETRICS Coeffici ents o f U tili zatio n rc rw Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 RCR 0 R2R-WL-1N5 2x2 (1) F14/835 1350 Lumens Cand ela 20% 10 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 109 109 109 109 106 106 106 106 102 102 102 97 97 97 93 93 93 91 1 2 98 88 93 80 89 73 84 67 95 86 91 78 87 72 83 67 87 75 84 70 80 65 83 72 81 67 78 63 80 69 78 65 76 62 74 60 3 4 5 6 80 73 67 62 70 61 55 49 62 53 46 41 55 46 40 34 78 71 65 60 68 60 54 48 61 52 45 40 55 46 39 34 65 58 52 46 59 51 44 39 54 45 39 34 63 56 50 45 57 50 34 38 53 45 38 34 60 54 48 43 56 48 42 338 52 44 38 33 50 42 36 31 7 8 9 10 57 53 50 47 44 40 37 34 36 32 29 27 30 27 24 22 56 52 48 45 44 40 37 34 36 32 29 27 30 27 24 22 42 39 35 33 35 32 29 26 30 27 24 22 41 37 34 32 34 31 28 26 30 26 24 22 40 36 34 31 34 31 28 25 29 26 24 21 27 24 22 20 Angle 0 Along II 379 o 45 379 Across I 379 5 10 380 374 379 375 378 376 15 20 365 352 368 359 371 366 25 30 35 40 335 314 289 261 346 329 310 288 356 345 331 316 45 50 55 60 233 203 174 145 265 240 216 190 300 282 263 245 65 70 75 80 116 88 63 39 165 142 117 87 226 205 178 141 85 90 18 0 45 0 75 0 Efficiency 91.4% Test Report #P30236 Zona l Lume n S umma r y Lu mi nance D ata Zone 0-30 Lumens 299 %Lamp 22.2 %Fixture 24.3 Angle in Deg 0-Deg cd/sm 45-Deg cd/sm 90-Deg cd/sm 0-40 0-60 0-90 493 893 1234 36.6 66.1 91.4 40.0 72.4 100.0 45 55 65 886 816 738 1008 1012 1050 1141 1233 1438 40-90 60-90 90-180 0-180 741 341 0 1234 54.8 25.3 0 91.4 60.0 27.6 0 100.0 75 85 654 555 1215 1388 1849 2313 FIT COMPATIBILITY GUIDELINES The Class R2R is an extremely low profile retrofit design and will fit the majority of existing lensed troffers and louvered parabolics. However, Corelite cannot guarantee fit with every existing luminaire – fit confirmation is therefore the responsibility of the end-user. For best results, contact your local representative for a sample or trial installation prior to ordering. CROSS SECTION END SECTION 24” [610mm] Typical Existing Recessed Housing Various Housing Mounting Bracket 3” [76mm] 3” [76mm] 2-1/4” [57mm] 22-1/4” [565mm] 23-7/8” [606mm] 1” [26mm] Existing Luminaire Ballast-Bracket Assembly Lamps (Optional) Lens Specifications and Dimensions subject to change without notice. Corelite • 18001 E. Colfax Ave. • Aurora, CO 80011 • 303.393.1522 • FAX 303.393.1477 ADE100074 09/26/2012 1:55:54 PM