Catalog # Type

advertisement
CORELITE
DESCRIPTION
The Corelite Class R2R Retrofit is designed to replace the core "lighting
engine" of dated and inefficient recessed luminaires, while leaving the
existing metal luminaire body intact. The total watts per luminaire can be
reduced between 30 and 40 percent while improving the overall lighting
quality and visual character of the interior space. The Class R2R is extremely
low in profile with a 3" overall height, allowing for retrofit of shallow 3"
lensed troffers. In addition to the energy cost reduction and improved
lighting conditions, the Class R2R's 80%+ luminaire efficiency meets the
requirements of many major rebate programs across the US.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
Construction
Three-piece retrofit assembly
consists of a ballast/bracket
assembly, reflector and lens.
Ballast/bracket assembly and
reflector each have captive
zinc-plated self-drilling hardware.
Mounting brackets are pre-paint
white 20-gauge die-formed steel.
Reflector is one piece die-formed
aluminum with a matte white
powder coat painted finish. Ballast
is pre-wired to factory installed
sockets on each mounting bracket
with the ballast/bracket assembly.
3" low-profile assembly will retrofit
into both parabolics and troffers.
Finish
Reflector is matte white powder
coat painted finish. Ballast brackets
are pre-paint white with white
semi-gloss finish.
Electrical
Ballast is fully tested and pre-wired
to factory installed sockets within
the ballast/bracket assembly, and
comes with captive self-drilling
hardware and integral quick
disconnects. T5/T5HO fixtures use
UL listed Class P, T5/T5HO
program rapid start universal
voltage electronic ballasts, with
pre-installed quick disconnect.
Standard Ballast Factor of 1.0 and
Power Factor of 98%.
Mounting
First, existing lamps, reflectors,
lenses, ballast covers, ballast and
socket trays must be removed
from existing luminaire. Next, the
ballast/bracket assembly is
installed by first mounting the
ballast to the top of the existing
luminaire, then by attaching the
mounting brackets. The reflector
then mounts to the ballast/bracket
assembly, and finally lamps and
lenses are installed.
Shielding
Luminaire lens is UV resistant
acrylic with an optically designed
prism structure, which diffuses
lamp image and provides high
light transmission and luminaire
efficiency (80%+).
NOTE: Fit Compatibility
Retrofit kit fits most troffers. The
end-user is responsible for
verifying fit. Therefore, a sample
kit is highly recommended.
CLASS R2R
Retrofit
Lensed
3T5
3T5HO
2'x4' Recessed Retrofit
Existing Recessed Luminiare*
3-1/8”
[79mm]
min
3”
[76mm]
24”
[610mm]
ORDERING INFORMATION
Sample Number: R2R-WL-3T5-1C-UNV-24-T1
Series
R2R=Class R2R
Retrofit
Reflector
W=White
Shielding
L=Linear Prismatic Lens
Number of Lamps
3=3 Lamps
Lamp Type
N5=T5 Normal Output
T5=T5 High Output
Number of
Circuits
1=1 Circuit
2=2 Circuits
1
Wiring 1
B=Battery Pack
Voltage 1
120=120V
C=Standard Circuit
D=Dimming / Step
Dimming
277=277V
347=347V
E=Emergency
T=Nightlight
Size
24=2' x 4'
Ceiling Type
T1=1" Grid2
UNV=Universal
(120V-277V)
Y=Daylight
Notes: 1
2
Not all options available. Please consult your Cooper Lighting Representative for
availability.
Ceiling Type T1 is for flush ceilings only. Consult factory for all other ceiling types.
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADE100075
09/26/2012 1:56:37 PM
Corelite
PHOTOMETRICS
C andela
C o ef f ic ie nt s o f Ut iliza t ion
rc
rw
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30
RCR
0
1
2
3
4
5
6
7
8
R2R-WL-3N5 2x4
(3) F28/835
8250 Lumens
9
10
20%
10
50%
50 30 10
30%
50 30 10
86
74
86
71
86
68
82
71
82
68
82
66
47
39
34
64
56
49
44
59
50
43
38
55
46
39
33
61
54
48
57
49
42
54
45
38
34
31
28
25
29
26
23
21
40
36
33
30
34
30
27
25
29
26
23
21
43
38
35
32
37
33
30
27
33
29
26
23
23
19
28
23
19
30
27
24
22
21
19
92
92
92
92
90
90
90
90
83
75
79
68
75
62
72
57
81
73
77
67
74
61
71
57
68
62
57
59
52
47
53
45
39
47
40
34
66
60
55
58
51
46
52
45
39
53
49
45
42
42
38
35
32
35
31
28
25
30
26
23
21
51
47
44
41
41
34
34
31
40
29
23
19
39
29
10%
50 30 10
0%
0
79
79
79
78
68
59
66
56
64
53
63
52
46
41
37
48
41
36
32
44
38
33
29
34
31
29
27
39
26
24
22
25
23
20
19
Angle
0
51
43
36
31
27
24
21
19
17
Efficiency 77.5%
Test Report
#P30228
Z on al L ume n Summa ry
Lumi nance D ata
Zone
0-30
0-40
0-60
Lumens
1595
2615
4677
%Lamp
19.3
31.7
56.7
%Fixture
25.0
40.9
73.1
Angle
in Deg
45
55
0-Deg
cd/sm
2350
2168
45-Deg
cd/sm
2620
2606
90-Deg
cd/sm
2903
3065
0-90
40-90
60-90
6394
3779
1717
77.5
45.8
20.8
100.0
59.1
26.9
65
75
85
1969
1740
1496
2672
3142
3640
3451
4404
5028
90-180
0-180
0
6394
0
77.5
0
100.0
Along II
2034
o
45
2034
Across I
2034
5
2037
2034
2027
10
15
2009
1958
2012
1072
2015
1984
20
25
30
35
1882
1786
1669
1536
1912
1836
1740
1629
1941
1879
1807
1721
40
45
50
55
1389
1236
1080
925
1508
1378
1246
1112
1628
1527
1420
1308
60
65
70
75
770
619
472
335
975
840
719
605
1194
1085
979
848
80
85
90
209
97
0
468
236
0
653
326
0
FIT COMPATIBILITY GUIDELINES
The Class R2R is an extremely low profile retrofit design and will fit the majority of existing lensed troffers and louvered parabolics. However, Corelite cannot guarantee
fit with every existing luminaire – fit confirmation is therefore the responsibility of the end-user. For best results, contact your local representative for a sample or trial
installation prior to ordering.
CROSS SECTION
END SECTION
24”
[610mm]
Typical Existing
Recessed Housing
Various Housing
Mounting
Bracket
3”
[76mm]
3”
[76mm]
2-1/4”
[57mm]
22-1/4”
[565mm]
23-7/8”
[606mm]
1”
[26mm]
Ballast-Bracket
Assembly
Existing Luminaire
Lamps
(Optional)
Lens
Specifications and Dimensions subject to change without notice.
Corelite • 18001 E. Colfax Ave. • Aurora, CO 80011 • 303.393.1522 • FAX 303.393.1477
ADE100075
09/26/2012 1:56:37 PM
Download