CORELITE DESCRIPTION The Corelite Class R2R Retrofit is designed to replace the core "lighting engine" of dated and inefficient recessed luminaires, while leaving the existing metal luminaire body intact. The total watts per luminaire can be reduced between 30 and 40 percent while improving the overall lighting quality and visual character of the interior space. The Class R2R is extremely low in profile with a 3" overall height, allowing for retrofit of shallow 3" lensed troffers. In addition to the energy cost reduction and improved lighting conditions, the Class R2R's 80%+ luminaire efficiency meets the requirements of many major rebate programs across the US. Type Catalog # Project Date Comments Prepared by SPECIFICATION FEATURES Construction Three-piece retrofit assembly consists of a ballast/bracket assembly, reflector and lens. Ballast/bracket assembly and reflector each have captive zinc-plated self-drilling hardware. Mounting brackets are pre-paint white 20-gauge die-formed steel. Reflector is one piece die-formed aluminum with a matte white powder coat painted finish. Ballast is pre-wired to factory installed sockets on each mounting bracket with the ballast/bracket assembly. 3" low-profile assembly will retrofit into both parabolics and troffers. Finish Reflector is matte white powder coat painted finish. Ballast brackets are pre-paint white with white semi-gloss finish. Electrical Ballast is fully tested and pre-wired to factory installed sockets within the ballast/bracket assembly, and comes with captive self-drilling hardware and integral quick disconnects. T5/T5HO fixtures use UL listed Class P, T5/T5HO program rapid start universal voltage electronic ballasts, with pre-installed quick disconnect. Standard Ballast Factor of 1.0 and Power Factor of 98%. Mounting First, existing lamps, reflectors, lenses, ballast covers, ballast and socket trays must be removed from existing luminaire. Next, the ballast/bracket assembly is installed by first mounting the ballast to the top of the existing luminaire, then by attaching the mounting brackets. The reflector then mounts to the ballast/bracket assembly, and finally lamps and lenses are installed. Shielding Luminaire lens is UV resistant acrylic with an optically designed prism structure, which diffuses lamp image and provides high light transmission and luminaire efficiency (80%+). NOTE: Fit Compatibility Retrofit kit fits most troffers. The end-user is responsible for verifying fit. Therefore, a sample kit is highly recommended. CLASS R2R Retrofit Lensed 2T5 2T5HO 2'x4' Recessed Retrofit Existing Recessed Luminiare* 3-1/8” [79mm] min 3” [76mm] 24” [610mm] ORDERING INFORMATION Sample Number: R2R-WL-2T5-1C-UNV-24-T1 Series R2R=Class R2R Retrofit Reflector W=White Shielding L=Linear Prismatic Lens Number of Lamps 2=2 Lamps Lamp Type N5=T5 Normal Output T5=T5 High Output Number of Circuits 1=1 Circuit 2=2 Circuits 1 Wiring 1 B=Battery Pack Voltage 1 120=120V C=Standard Circuit D=Dimming / Step Dimming 277=277V 347=347V E=Emergency T=Nightlight UNV=Universal (120V-277V) Size 24=2' x 4' Options 1 SD=Step Dimming Ceiling Type T1=1" Grid2 Y=Daylight Notes: 1 2 Not all options available. Please consult your Cooper Lighting Representative for availability. Ceiling Type T1 is for flush ceilings only. Consult factory for all other ceiling types. Specifications and Dimensions subject to change without notice. Consult your representative for additional options and finishes. ADE100073 09/26/2012 1:54:55 PM Corelite PHOTOMETRICS C andela C o ef f ic ie nt s o f Ut iliza t ion rc rw Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 RCR 0 1 2 3 4 5 6 7 8 R2R-WL-2N5 2x4 (2) F28/835 5500 Lumens 9 10 20% 10 50% 50 30 10 30% 50 30 10 92 79 92 76 92 73 88 75 88 73 88 71 50 42 36 68 59 52 47 63 54 46 40 59 49 41 35 65 57 50 61 52 45 58 48 41 37 33 29 27 31 28 24 22 41 37 34 31 35 31 28 26 31 27 24 22 45 41 37 34 40 35 31 28 35 31 27 24 24 20 29 24 20 31 29 25 24 22 20 98 98 98 98 96 96 96 96 89 80 84 72 80 66 76 61 86 78 82 71 79 65 75 60 73 66 61 63 56 50 56 48 42 50 42 36 70 64 59 62 55 49 55 47 41 56 52 48 45 45 40 37 34 37 33 30 27 31 28 25 22 54 50 47 44 44 40 36 33 42 31 24 20 41 31 10% 50 30 10 0% 0 84 84 84 83 72 63 70 59 68 56 67 55 49 44 39 51 44 39 34 47 40 35 30 36 33 31 28 31 28 25 23 27 24 22 20 Angle 0 54 45 38 33 29 25 22 20 18 Efficiency 82.5% Test Report #P30229 Z on al L ume n Summa ry Lumi nance D ata Zone 0-30 0-40 0-60 Lumens 1126 1846 3309 %Lamp 20.5 33.6 60.2 %Fixture 24.8 40.7 72.9 Angle in Deg 45 55 0-Deg cd/sm 1663 1540 45-Deg cd/sm 1855 1851 90-Deg cd/sm 2059 2187 0-90 40-90 60-90 4538 2692 1229 82.5 48.9 22.3 100.0 59.3 27.1 65 75 85 1403 1246 1064 1912 2285 2529 2494 3199 3424 90-180 0-180 0 4538 0 82.5 0 100.0 Along II 1434 o 45 1434 Across I 1434 5 1433 1435 1430 10 15 1413 1377 1420 1392 1421 1400 20 25 30 35 1325 1257 1176 1083 1350 1296 1229 1152 1370 1327 1275 1216 40 45 50 55 981 875 766 657 1067 976 883 790 1150 1083 1009 933 60 65 70 75 548 441 338 240 694 601 519 440 855 784 712 616 80 85 90 150 69 0 338 164 0 468 222 0 FIT COMPATIBILITY GUIDELINES The Class R2R is an extremely low profile retrofit design and will fit the majority of existing lensed troffers and louvered parabolics. However, Corelite cannot guarantee fit with every existing luminaire – fit confirmation is therefore the responsibility of the end-user. For best results, contact your local representative for a sample or trial installation prior to ordering. CROSS SECTION END SECTION 24” [610mm] Typical Existing Recessed Housing Various Housing Mounting Bracket 3” [76mm] 3” [76mm] 2-1/4” [57mm] 22-1/4” [565mm] 23-7/8” [606mm] 1” [26mm] Ballast-Bracket Assembly Existing Luminaire Lamps (Optional) Lens Specifications and Dimensions subject to change without notice. Corelite • 18001 E. Colfax Ave. • Aurora, CO 80011 • 303.393.1522 • FAX 303.393.1477 ADE100073 09/26/2012 1:54:55 PM