Catalog # Type

advertisement
CORELITE
DESCRIPTION
The Corelite Class R2R Retrofit is designed to replace the core "lighting
engine" of dated and inefficient recessed luminaires, while leaving the
existing metal luminaire body intact. The total watts per luminaire can be
reduced between 30 and 40 percent while improving the overall lighting
quality and visual character of the interior space. The Class R2R is extremely
low in profile with a 3" overall height, allowing for retrofit of shallow 3"
lensed troffers. In addition to the energy cost reduction and improved
lighting conditions, the Class R2R's 80%+ luminaire efficiency meets the
requirements of many major rebate programs across the US.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
Construction
Three-piece retrofit assembly
consists of a ballast/bracket
assembly, reflector and lens.
Ballast/bracket assembly and
reflector each have captive
zinc-plated self-drilling hardware.
Mounting brackets are pre-paint
white 20-gauge die-formed steel.
Reflector is one piece die-formed
aluminum with a matte white
powder coat painted finish. Ballast
is pre-wired to factory installed
sockets on each mounting bracket
with the ballast/bracket assembly.
3" low-profile assembly will retrofit
into both parabolics and troffers.
Finish
Reflector is matte white powder
coat painted finish. Ballast brackets
are pre-paint white with white
semi-gloss finish.
Electrical
Ballast is fully tested and pre-wired
to factory installed sockets within
the ballast/bracket assembly, and
comes with captive self-drilling
hardware and integral quick
disconnects. T5/T5HO fixtures use
UL listed Class P, T5/T5HO
program rapid start universal
voltage electronic ballasts, with
pre-installed quick disconnect.
Standard Ballast Factor of 1.0 and
Power Factor of 98%.
Mounting
First, existing lamps, reflectors,
lenses, ballast covers, ballast and
socket trays must be removed
from existing luminaire. Next, the
ballast/bracket assembly is
installed by first mounting the
ballast to the top of the existing
luminaire, then by attaching the
mounting brackets. The reflector
then mounts to the ballast/bracket
assembly, and finally lamps and
lenses are installed.
Shielding
Luminaire lens is UV resistant
acrylic with an optically designed
prism structure, which diffuses
lamp image and provides high
light transmission and luminaire
efficiency (80%+).
NOTE: Fit Compatibility
Retrofit kit fits most troffers. The
end-user is responsible for
verifying fit. Therefore, a sample
kit is highly recommended.
CLASS R2R
Retrofit
Lensed
2T5
2T5HO
2'x4' Recessed Retrofit
Existing Recessed Luminiare*
3-1/8”
[79mm]
min
3”
[76mm]
24”
[610mm]
ORDERING INFORMATION
Sample Number: R2R-WL-2T5-1C-UNV-24-T1
Series
R2R=Class R2R
Retrofit
Reflector
W=White
Shielding
L=Linear Prismatic Lens
Number of Lamps
2=2 Lamps
Lamp Type
N5=T5 Normal Output
T5=T5 High Output
Number of
Circuits
1=1 Circuit
2=2 Circuits
1
Wiring 1
B=Battery Pack
Voltage 1
120=120V
C=Standard Circuit
D=Dimming / Step
Dimming
277=277V
347=347V
E=Emergency
T=Nightlight
UNV=Universal
(120V-277V)
Size
24=2' x 4'
Options 1
SD=Step Dimming
Ceiling Type
T1=1" Grid2
Y=Daylight
Notes: 1
2
Not all options available. Please consult your Cooper Lighting Representative for
availability.
Ceiling Type T1 is for flush ceilings only. Consult factory for all other ceiling types.
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADE100073
09/26/2012 1:54:55 PM
Corelite
PHOTOMETRICS
C andela
C o ef f ic ie nt s o f Ut iliza t ion
rc
rw
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30
RCR
0
1
2
3
4
5
6
7
8
R2R-WL-2N5 2x4
(2) F28/835
5500 Lumens
9
10
20%
10
50%
50 30 10
30%
50 30 10
92
79
92
76
92
73
88
75
88
73
88
71
50
42
36
68
59
52
47
63
54
46
40
59
49
41
35
65
57
50
61
52
45
58
48
41
37
33
29
27
31
28
24
22
41
37
34
31
35
31
28
26
31
27
24
22
45
41
37
34
40
35
31
28
35
31
27
24
24
20
29
24
20
31
29
25
24
22
20
98
98
98
98
96
96
96
96
89
80
84
72
80
66
76
61
86
78
82
71
79
65
75
60
73
66
61
63
56
50
56
48
42
50
42
36
70
64
59
62
55
49
55
47
41
56
52
48
45
45
40
37
34
37
33
30
27
31
28
25
22
54
50
47
44
44
40
36
33
42
31
24
20
41
31
10%
50 30 10
0%
0
84
84
84
83
72
63
70
59
68
56
67
55
49
44
39
51
44
39
34
47
40
35
30
36
33
31
28
31
28
25
23
27
24
22
20
Angle
0
54
45
38
33
29
25
22
20
18
Efficiency 82.5%
Test Report
#P30229
Z on al L ume n Summa ry
Lumi nance D ata
Zone
0-30
0-40
0-60
Lumens
1126
1846
3309
%Lamp
20.5
33.6
60.2
%Fixture
24.8
40.7
72.9
Angle
in Deg
45
55
0-Deg
cd/sm
1663
1540
45-Deg
cd/sm
1855
1851
90-Deg
cd/sm
2059
2187
0-90
40-90
60-90
4538
2692
1229
82.5
48.9
22.3
100.0
59.3
27.1
65
75
85
1403
1246
1064
1912
2285
2529
2494
3199
3424
90-180
0-180
0
4538
0
82.5
0
100.0
Along II
1434
o
45
1434
Across I
1434
5
1433
1435
1430
10
15
1413
1377
1420
1392
1421
1400
20
25
30
35
1325
1257
1176
1083
1350
1296
1229
1152
1370
1327
1275
1216
40
45
50
55
981
875
766
657
1067
976
883
790
1150
1083
1009
933
60
65
70
75
548
441
338
240
694
601
519
440
855
784
712
616
80
85
90
150
69
0
338
164
0
468
222
0
FIT COMPATIBILITY GUIDELINES
The Class R2R is an extremely low profile retrofit design and will fit the majority of existing lensed troffers and louvered parabolics. However, Corelite cannot guarantee
fit with every existing luminaire – fit confirmation is therefore the responsibility of the end-user. For best results, contact your local representative for a sample or trial
installation prior to ordering.
CROSS SECTION
END SECTION
24”
[610mm]
Typical Existing
Recessed Housing
Various Housing
Mounting
Bracket
3”
[76mm]
3”
[76mm]
2-1/4”
[57mm]
22-1/4”
[565mm]
23-7/8”
[606mm]
1”
[26mm]
Ballast-Bracket
Assembly
Existing Luminaire
Lamps
(Optional)
Lens
Specifications and Dimensions subject to change without notice.
Corelite • 18001 E. Colfax Ave. • Aurora, CO 80011 • 303.393.1522 • FAX 303.393.1477
ADE100073
09/26/2012 1:54:55 PM
Download