Catalog # Type

advertisement
CORELITE
DESCRIPTION
The Corelite Class R2R Retrofit is designed to replace the core "lighting
engine" of dated and inefficient recessed luminaires, while leaving the
existing metal luminaire body intact. The total watts per luminaire can be
reduced between 30 and 40 percent while improving the overall lighting
quality and visual character of the interior space. The Class R2R is extremely
low in profile with a 3" overall height, allowing for retrofit of shallow 3"
lensed troffers. In addition to the energy cost reduction and improved
lighting conditions, the Class R2R's 80%+ luminaire efficiency meets the
requirements of many major rebate programs across the US.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
Construction
Three-piece retrofit assembly
consists of a ballast/bracket
assembly, reflector and lens.
Ballast/bracket assembly and
reflector each have captive
zinc-plated self-drilling hardware.
Mounting brackets are pre-paint
white 20-gauge die-formed steel.
Reflector is one piece die-formed
aluminum with a matte white
powder coat painted finish. Ballast
is pre-wired to factory installed
sockets on each mounting bracket
with the ballast/bracket assembly.
3" low-profile assembly will retrofit
into both parabolics and troffers.
Finish
Reflector is matte white powder
coat painted finish. Ballast brackets
are pre-paint white with white
semi-gloss finish.
Electrical
Ballast is fully tested and pre-wired
to factory installed sockets within
the ballast/bracket assembly, and
comes with captive self-drilling
hardware and integral quick
disconnects. T5/T5HO fixtures use
UL listed Class P, T5/T5HO
program rapid start universal
voltage electronic ballasts, with
pre-installed quick disconnect.
Standard Ballast Factor of 1.0 and
Power Factor of 98%.
Mounting
First, existing lamps, reflectors,
lenses, ballast covers, ballast and
socket trays must be removed
from existing luminaire. Next, the
ballast/bracket assembly is
installed by first mounting the
ballast to the top of the existing
luminaire, then by attaching the
mounting brackets. The reflector
then mounts to the ballast/bracket
assembly, and finally lamps and
lenses are installed.
Shielding
Luminaire lens is UV resistant
acrylic with an optically designed
prism structure, which diffuses
lamp image and provides high
light transmission and luminaire
efficiency (80%+).
NOTE: Fit Compatibility
Retrofit kit fits most troffers. The
end-user is responsible for
verifying fit. Therefore, a sample
kit is highly recommended.
CLASS R2R
Retrofit
Lensed
2T5
2T5HO
2'x2' Recessed Retrofit
Existing Recessed Luminiare*
3-1/8”
[79mm]
min
3”
[76mm]
24”
[610mm]
ORDERING INFORMATION
Sample Number: R2R-WL-2T5-1C-UNV-22-T1
Series
R2R=Class R2R
Retrofit
Reflector
W=White
Shielding
L=Linear Prismatic Lens
Number of Lamps
2=2 Lamps
Lamp Type
N5=T5 Normal Output
T5=T5 High Output
Number of
Circuits
1=1 Circuit
2=2 Circuits
1
Wiring 1
B=Battery Pack
Voltage 1
120=120V
C=Standard Circuit
D=Dimming / Step
Dimming
277=277V
347=347V
E=Emergency
T=Nightlight
UNV=Universal
(120V-277V)
Size
22=2' x 2'
Options 1
SD=Step Dimming
Ceiling Type
T1=1" Grid2
Y=Daylight
Notes: 1
2
Not all options available. Please consult your Cooper Lighting Representative for
availability.
Ceiling Type T1 is for flush ceilings only. Consult factory for all other ceiling types.
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADE100072
09/26/2012 1:54:09 PM
Corelite
PHOTOMETRICS
Coeffici ents o f U tili zatio n
rc
rw
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30
RCR
0
R2R-WL-2N5 2x2
(2) F14/835
2700 Lumens
Cand ela
20%
10
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
106 106 106 106
104 104 104 104
99
99
99
95
95
95
91
91
91
89
1
2
96
87
91
79
87
72
83
66
93
84
89
77
85
71
82
66
85
74
82
68
79
64
82
71
79
66
77
62
78
68
76
64
74
61
72
59
3
4
5
6
79
72
66
61
69
60
54
48
61
52
45
40
54
46
39
34
76
70
64
59
67
59
53
47
60
51
45
40
54
45
39
34
64
57
51
46
58
50
44
39
53
45
39
34
62
55
49
44
56
49
43
38
52
44
38
33
59
53
47
43
55
48
42
37
51
44
38
33
49
42
36
31
7
8
9
10
56
52
49
46
44
40
37
34
36
32
29
27
30
27
24
22
55
51
48
45
43
39
36
33
35
32
29
26
30
27
24
22
42
38
35
32
35
31
28
26
30
26
24
22
40
37
34
32
34
31
28
26
29
26
24
21
39
36
33
31
33
30
28
25
29
26
24
21
27
24
22
20
Angle
0
Along II
765
o
45
765
Across I
765
5
10
765
753
765
756
764
758
15
20
734
706
741
721
747
733
25
30
35
40
671
627
576
521
692
657
615
569
712
685
653
619
45
50
55
60
463
404
344
286
520
470
420
369
584
545
504
463
65
70
75
80
229
174
122
76
317
272
226
167
426
387
333
255
85
90
35
0
79
0
118
0
Efficiency 89.3%
Test Report
#P30235
Zona l Lume n S umma r y
Lu mi nance D ata
Zone
0-30
Lumens
601
%Lamp
22.2
%Fixture
24.9
Angle
in Deg
0-Deg
cd/sm
45-Deg
cd/sm
90-Deg
cd/sm
0-40
0-60
0-90
985
1766
2410
36.5
65.4
89.3
40.9
73.3
100.0
45
55
65
1760
1612
1457
1977
1969
2017
2220
2362
2710
40-90
60-90
90-180
0-180
1425
644
0
2410
52.8
23.9
0
89.3
59.1
26.7
0
100.0
75
85
1267
1080
2348
2437
3459
3640
FIT COMPATIBILITY GUIDELINES
The Class R2R is an extremely low profile retrofit design and will fit the majority of existing lensed troffers and louvered parabolics. However, Corelite cannot guarantee
fit with every existing luminaire – fit confirmation is therefore the responsibility of the end-user. For best results, contact your local representative for a sample or trial
installation prior to ordering.
CROSS SECTION
END SECTION
24”
[610mm]
Typical Existing
Recessed Housing
Various Housing
Mounting
Bracket
3”
[76mm]
3”
[76mm]
2-1/4”
[57mm]
22-1/4”
[565mm]
23-7/8”
[606mm]
1”
[26mm]
Existing Luminaire
Ballast-Bracket
Assembly
Lamps
(Optional)
Lens
Specifications and Dimensions subject to change without notice.
Corelite • 18001 E. Colfax Ave. • Aurora, CO 80011 • 303.393.1522 • FAX 303.393.1477
ADE100072
09/26/2012 1:54:09 PM
Download