Metalux D ES C R IPTION Type Catalog # ArcLine is a premium grade specification lensed troffer series. This innovative, high quality luminaire is dedicated to the latest lamp and micro electronic ballast technology for optimal performance and energy efficiency. The ArcLine is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. Project Date Comments Prepared by The ArcLine series features efficiency, quality and performance. The series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. SPE C IFIC A TION FEA T U R E S C on s t r u c t i o n E le ctrica l H inging/Latching Rigid housing is die formed of code gauge prime cold rolled steel and features full length die-formed stiffeners and unibody endplate for added strength. Side flanges are hemmed. Innovative design provides superior lens brightness uniformity and visual comfort. Die formed captive lampholder brackets fully enclose lampholder wiring permitting easy lampholder replacement. Unibody endplates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. Endplates have integral Gridlock feature for safety and convenience. Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Rotor lock lampholders. UL/CUL listed. Suitable for damp locations.** Positive cam action steel latches with baked white enamel finish. Safety-lock T-hinges allow hinging and latching either side. Door assembly hinges down for easy access from below without tools. F in ish Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Housing and ballast cover finished with new 90% reflective white enamel for superior performance. Frame/Shielding Die formed, heavy gauge, flat steel door with reinforced mitered corners and paint after fabrication, baked matte white enamel finish. Positive light seals. Light stabilized, acrylic frosted lens. 2ALN 328T5 354T5 2' X 4' TROFFER 3 T5 LAMPS Specification Architectural Troffer 3-1/4" [83mm] For Use In Insulated Ceilings 23-3/4" [603mm] MO UNTING D A TA D OOR F RA ME S 47-15/16" [1218mm] ALN Flat, White Steel ENERGY DATA Input Watts: EB Ballast & STD Lamps 328T5 (97), 354T5 (182) 23-3/4" [603mm] L A MP CONF IGURA T IONS 3-1/4" [83mm] *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. **Consult Pre Sales Technical Support. ****When ordering Flange Kit for installation in drywall ceilings, see options and accessories compatibility section and ordering logic. 23-3/4" [603mm] CEI LING C OM PA TIB I L I T Y G Grid/Lay-in Standard G Concealed T G Slot Grid Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid G G G (Verify compatibility/ consult factory.) LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF122033 2015-06-09 11:42:08 2 ALN T 5 PHOTOM ETR IC S 90˚ 75˚ 850 60˚ 1700 45˚ 2550 0˚ 15˚ 30˚ 2ALNG-328T5-UNVEBT2-U Electronic Ballast (3) F28T5 Lamps 2900 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.3 x mounting height Efficiency 82.6% Lumens: 7185 LER = FL87 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.76 Test Report: 2ALNG-328T5-UNVEBT2-U.IES Candlepower Along II 2481 2476 2438 2372 2278 2161 2020 1870 1700 1523 1327 1138 942 753 576 398 235 101 0 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 45° 2481 2469 2436 2381 2301 2204 2089 1960 1812 1650 1479 1297 1105 907 714 522 350 151 0 Across ⊥ 2481 2478 2451 2406 2338 2260 2163 2054 1928 1779 1620 1432 1235 1030 833 625 391 154 0 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 98 90 81 74 68 62 57 53 50 46 43 98 85 74 65 58 51 46 42 38 35 32 98 82 69 58 50 44 39 35 31 28 26 98 79 64 53 45 38 33 29 26 24 21 96 87 79 72 66 60 56 52 48 45 42 96 84 73 64 56 50 45 41 38 35 32 96 80 67 57 50 43 38 34 31 28 26 96 77 63 52 44 38 33 29 26 24 21 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180 Lumens 1926 3153 5579 7185 7185 %Lamp 22.1 36.2 64.1 82.6 82.6 75˚ 1200 60˚ 2400 45˚ 3600 0˚ 15˚ 30˚ 2ALNG-354T5-UNVEBT1-U Electronic Ballast (3) F54T5 Lamps 4400 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.3 x mounting height Efficiency 78.2% Lumens: 10325 LER = FL61 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.93 Test Report: 2ALNG-354T5-UNVEBT1-U.IES Candlepower Along II 3555 3546 3489 3394 3266 3091 2908 2685 2443 2169 1907 1631 1352 1088 822 572 343 145 0 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 45° 3555 3538 3492 3414 3308 3168 3008 2814 2610 2374 2132 1869 1587 1308 1023 762 497 220 0 Across ⊥ 3555 3555 3515 3457 3366 3254 3114 2955 2772 2558 2326 2047 1777 1477 1187 888 569 223 0 C o e f fi c i e n t s o f U t i l i z a t i o n C o e f fi c i e n t s o f U t i l i z a t i o n rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 90˚ %Fixture 26.8 43.9 77.7 100.0 100.0 20% 50% 50 30 10 30% 50 30 10 50 92 80 70 61 54 49 44 40 37 34 31 88 77 67 59 52 47 43 39 36 33 30 84 74 65 57 51 46 41 38 35 32 30 92 77 65 56 48 42 38 34 30 28 25 92 75 61 51 44 38 33 29 26 23 21 88 75 63 54 47 42 37 33 30 27 25 88 72 60 50 43 37 33 29 26 23 21 10% 30 10 84 72 61 53 46 41 36 33 29 27 25 84 70 59 50 42 37 32 29 26 23 21 0% 0 83 69 57 48 41 35 31 27 24 22 20 Luminance Data Angle in Deg 45 55 65 85 75 Average 0-Deg cd/sm 3294 3044 2752 1854 2389 Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Average 45-Deg cd/sm 3592 3443 3276 2499 3068 Average 90-Deg cd/sm 3901 3853 3758 2701 3774 Specifications and dimensions subject to change without notice. rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 93 85 77 70 64 59 54 50 47 44 41 93 81 70 62 55 49 44 40 36 33 31 93 78 65 55 48 42 37 33 29 27 24 93 74 60 50 42 36 32 28 25 22 20 91 83 75 68 62 57 53 49 46 43 40 91 79 69 60 53 48 43 39 36 33 30 91 76 64 54 47 41 36 32 29 27 24 91 73 60 49 42 36 31 28 25 22 20 20% 50% 50 30 10 30% 50 30 10 50 87 76 66 58 52 46 42 38 35 32 29 83 73 63 56 50 45 40 37 34 31 29 80 70 61 54 48 43 39 36 33 30 28 87 73 62 53 46 40 36 32 29 26 24 87 71 58 49 41 36 31 28 25 22 20 83 71 60 51 45 39 35 31 28 26 24 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 85 75 Lumens 2766 4530 8020 10325 10325 %Lamp 21.0 34.3 60.8 78.2 78.2 %Fixture 26.8 43.9 77.7 100.0 100.0 Average 0-Deg cd/sm 3294 3044 2752 1854 2389 83 69 57 48 41 35 31 27 24 22 20 10% 30 10 Average 45-Deg cd/sm 3592 3443 3276 2499 3068 80 68 58 50 44 39 34 31 28 25 23 80 67 56 47 40 35 31 27 24 22 20 0% 0 78 65 54 45 38 33 29 26 23 20 19 Average 90-Deg cd/sm 3901 3853 3758 2701 3774 ADF122033 2015-06-09 11:42:08 2 ALN T 5 OR D ER ING INFOR M A TION SAMPLE NUMBER: 2ALNG-328T5-UNV-EBT2-U Rating Blank= Standard ATW-SW4= Chicago Rated Width 2=2' Width Series ALN=ArcLine Series Number of Lamps 3=3 Lamps Voltage (2) 347V=347 Volt UNV=Universal Voltage 120-277 (3) (Not included) Wattage (Length) 28T5=28W T5 (48") (6) 54T5=54W T5HO (48") Shielding Blank=Smooth Frosted Acrylic (standard) Trim Type G=Grid/Lay-in (Standard) (1) G=Concealed T G=Slot Grid Options GL=Single Element Fuse GM=Double Element Fuse Lamps=Lamps Installed (see options and accessories) Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed (5) Ballast Type (2) EBT =T5/T5HO Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor=1.0 Ballast/FactorType EBT N=T5 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Normal Ballast Factor=.90 EBT HDIM=T5 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming, High Ballast Factor=1.15 (4) Options G1=Gasket, Door Frame and Housing (Standard) G2=G1 plus Gasket between Lens and Door G3=G1 and G2 plus Gasketing on Mounting Surface of Fixture Trims Packaging U=Unit Pack PALC=Job Pack, in carton Number of Ballasts 1=1 Ballast 2=2 Ballasts Door Frame Standard=Flat White Steel Door (Leave Blank) ACCESSORIES (1) (2) NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Products also available in non-US voltages and frequencies (3) (4) for international markets. Not available when specifying emergencies, voltage must be specific. Step Dimming ballast available for (5) (6) 3 28W T5 lamps only. Non integral solution only, must specify voltage. 3-Lamp 328T5 requires two ballasts. EQ-CLIP-U=T-BAR Safety Earthquake Clips (1) DF-24-W=2' x 4' Drywall Flange Kit Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. SH IP P ING D ATA Catalog No. 2ALNG-328T5 2ALNG-354T5 Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. Wt. 20 lbs. 20 lbs. ADF122033 2015-06-09 11:42:08