Zero 88 Engineering Specifications Juggler – Lighting Desk North American Headquarters 203 Cooper Circle Peachtree City, GA 30269 P: 800-553-3879 F: 800-954-7016 International Headquarters 20 Greenhill Crescent Watford Business Park Watford, Herts, WD18 8XG. UK P: +44 (0)1923 495495 F: +44 (0)1923 228796 Service and Support Center 6 Green Tree Drive South Burlington, VT 05403 P: 800-553-3879 F: 800-954-7016 www.coopercontrol.com Part 1 - Electronics 1. The lighting control console shall provide 24 channels of control with 24 channel faders arranged in a 2 preset configuration. 2. Each preset shall have an overall preset master control. 3. The preset master controls shall be arranged in an opposing fashion such that single movement crossfades can be achieved. 4. Two preset operation in Wide mode shall be achieved by means of storing one preset in internal memory, which shall be mixed with the front panel preset. 5. Crossfades between the two presets shall be microprocessor controlled and provide true dipless operation. 6. Each channel shall have an independent flash button located beneath the lower preset faders. 7. The flash function shall be selectable for channels 1 – 12 or 13 – 24 in Wide Mode. 8. The flash buttons shall have a selectable on / off function operated by a separate control with an LED status indicator. 9. The console shall store and playback 12 sequences (1 at a time) with a maximum of 99 steps each. 10. It shall be possible to select any step of any sequence for programming, editing, or deletion. 11. The selected sequence or step shall be indicated by a 2-digit 7-segment display. 12. The sequence speed shall be controlled by an independent speed control, which shall also have a manual step setting. 13. The sequence shall have an independent master control. 14. The control console shall have an overall Grand Master control. 15. The console shall have a rear-mounted control output connector. 16. The console shall be DMX equipped and shall have a single XLR5 fixed socket with overvoltage protection. 17. The console shall be tested both during assembly and at finished product stages. Part 2 - Operation 1. The console shall provide clear indication of power supply, flash function, wide mode, and sequence status via front panel LEDs and displays. Part 3 - Electrical 1. The console shall operate from a single-phase supply. 2. The supply requirements shall be: 100-240V AC, 50-60Hz. 3. The unit shall consume no more than 10 Watts. Part 4 - Mechanical 1. The console shall be 19” (483mm) wide, 11” (279mm) deep and 3.5” (88mm) in height. 2. The console shall weigh no more than 9.92 lbs. (4.5 Kg). 3. The chassis shall be constructed of steel and shall be provided with a removable steel front panel for access to internal electronics. 4. The console shall be configured for both desktop and19” rack mounted operation. 5. All metal surfaces shall be properly treated and finished in specialist paint or powder coat. 6. The control surface shall be 1.6mm zinc plated steel. 7. All operator controls and displays shall be provided on the top operating surface of the console. 8. The console shall have rear-mounted connectors for power supply and DMX on a recessed panel. 9. The operating environment for the console shall be 41°F - 104°F (+5°C - 40°C) non-condensing. Page 1 of 1 ACC091431