cooper lighting—lumark

advertisement
TYPE:
C AT A L O G # :
DESCRIPTION
S P E C I F I C AT I O N F E AT U R E S
The Vertimark II delivers
horizontal and vertical
footcandles to evenly
illuminate parking garage
areas. The combination
die-cast reflector/ ballast
housing makes Vertimark II
economical. Modular assembly
makes installation easy and
quality construction ensures
years of consistent performance.
U.L. listed and labeled for
damp location. CSA Certified.
A ...P e n d a n t M o u n t i n g
E ...B a l l a s t C o m p a r t m e n t
Standard quick mounting plate
for 3/4" IPS conduit frees both
hands to complete wiring.
Removable ballast
compartment cover provides
easy internal access.
B ...H o u s i n g
F ...O p t i o n a l J - B o x M o u n t i n g
Die-cast aluminum housing
has durable white polyester
powder coat finish.
Factory-installed mounting
bracket fits a standard 4" J-Box
for outlet box or surface
mounting.
A P P L I C AT I O N
COOPER LIGHTING—LUMARK
C ...R e f r a c t o r H i n g e
Hinged refractor permits
relamping without removal of
refractor.
BEVERTIMARK II
D ...R e f r a c t o r
Durable construction and
dependable performance make
the Vertimark II perfect for
parking garages. U.L. listed
and CSA certified for indoor
applications. Optional U.L. wet
location listing available.
Acrylic prismatic refractor
controls light for high vertical
and horizontal footcandles.
1 0 0 - 2 5 0 W
High Pressure Sodium
Pulse Start Metal Halide
Metal Halide
L O W - B AY
INDUSTRIAL LUMINAIRE
A
B
C
Surface
12 1/2"
[318mm]
Pendant
13 1/4"
[337mm]
D
E
17"
[432mm]
OPTIONAL J-BOX
S TA N D A R D E Z 1 2 3 M O U N T I N G
E N E R G Y D AT A
3/4"
[19mm]
High-Reactance Ballast Input Watts
100W HPS HPF (130 Watts)
150W HPS HPF (190 Watts)
Once in place, the EZ123
readily accepts the mating
half of the hinge and the
fixture is easily attached.
2 9/16"
[65mm]
5 1/8"
[130mm]
S H I P P I N G D AT A
Approximate Net Weight:
17 lbs. (8 kgs.)
ADH041465
C
COOPER LIGHTING
YS
ER
T EM
S
S
5 1/8"
[130mm]
2 9/16"
[65mm]
CWA Ballast Input Watts
175W MH HPF (210 Watts)
250W MH/MV HPF (295 Watts)
D
3/4"
[19mm]
Reactor Ballast Input Watts
70W HPS NPF/HPF (82 Watts)
100W HPS HPF (118 Watts)
150W HPS HPF (175 Watts)
TIFIE
®
B E VERTIMARK II
PHOTOMETRICS
90°
5
10
15
60°
20
25
30
30°
35
40
45
50
CP/100
H P B E - 5 A - 1 5 0 H - 1 2 0 V- L L
150-Watt HPS
16,000-Lumen Clear Lamp
Spacing Criterion
1.6
Zone
%Lamp
Zone
0-30
11.67
0-90
0-40
19.95
90-180
0-60
53.54
Total
90°
5
10
15
25
30°
35
40
45
50
CP/100
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
76
61
50
40
33
28
23
19
16
13
78
67
58
51
47
39
324
30
27
24
72
62
54
47
41
36
31
28
25
22
66
57
50
43
37
33
29
25
23
20
58
47
39
31
26
21
17
14
12
9
0%
Candlepower
Degree CP
0
1651
74
62
52
44
37
32
27
23
20
17
71
57
47
38
31
26
22
18
16
13
69
58
49
41
35
30
25
22
19
16
66
54
44
36
30
25
20
17
15
12
64
54
45
38
32
28
23
20
18
15
62
50
42
34
28
23
19
16
14
11
%Lamp
77.41
14.83
92.23
50%
30%
10%
50 30 10
50 30 10
50 30 10
50 30 10
50 30 10
0
85
72
61
52
45
40
35
31
28
25
82
69
59
50
43
38
34
30
27
24
75
64
44
46
40
35
31
28
25
22
70
59
50
42
36
32
29
26
23
21
64
54
46
39
33
29
26
23
21
19
56
44
34
27
21
17
14
12
10
8
80
65
53
43
36
31
26
23
20
17
75
58
46
36
29
24
20
17
15
12
Spacing Criterion
1.7
Zone
%Lamp
Zone
0-30
10.12
0-90
0-40
16.69
90-180
0-60
41.74
Total
M H B E - 5 A - 1 7 5 H - M T- L L
175-Watt MH
14,000-Lumen Clear Lamp
10
Candlepower
Degree CP
0
2113
5
1888
15
1748
25
2308
35
2003
45
2329
55
3855
65
1964
75
1020
85
845
90
787
Coefficients Of Utilization
Effective floor cavity reflectance = 20%
rc
80%
70%
rw
RCR
1
2
3
4
5
6
7
8
9
10
60°
20
30
Coefficients Of Utilization
Effective floor cavity reflectance = 20%
rc
80%
70%
rw
50 30 10
50 30
RCR
1
88 83 79
85 80
2
76 69 63
73 66
3
66 58 51
63 56
4
57 48 41
55 47
5
50 41 34
48 39
6
44 35 28
42 34
7
38 30 23
37 29
8
34 25 20
33 25
9
31 22 17
29 22
10
29 19 14
26 18
77
62
51
42
34
30
25
22
20
17
73
56
44
35
28
23
19
14
14
12
72
58
54
39
32
28
24
21
18
16
68
53
48
33
26
22
18
16
14
11
66
54
44
36
30
26
22
19
17
15
63
50
40
31
25
21
17
15
13
10
62
50
41
33
28
24
21
18
16
14
59
47
37
29
23
19
16
14
12
10
5
15
25
35
45
55
65
75
85
90
1463
1362
1772
1388
1595
2087
3456
1020
810
637
%Lamp
76.90
13.16
90.05
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : H P B E - 5 A - 1 0 0 H - M T- L L
BE
Lamp Type
Series
HP=High
BE=Vertimark II
Pressure
1
Sodium
MH=Metal Halide
MP=Pulse Start MH (CWA) 2
Lens Type
2A=Type II
5A=Type V
2P=Type II
Polycarbonate 3
5P=Type V
Polycarbonate 3
Lamp Wattage
100=100W
150=150W
175=175W
200=200W
250=250W
Options (add as suffix) 9
HL=LumaWatt Fixture Control Module (Allows low voltage control wire to be daisey-chained between fixtures
outside AC conduit run similar to low voltage intercoms, fire alarms and phone systems) 10
Q=Quartz Restrike DC Bayonet Base (Hot strike only) 11
EM=Quartz Restrike with “Delay Relay”– Housing Mounted (dry locations only) 11
EM/SC=Emergency Separate Circuit– Reflector Mounted 11
F1=Single Fuse—120, 277 or 347V (Specify single voltage only)
F2=Double Fused—208, 240 or 480V (Specify single voltage only)
FH-1=Fixture Hook
FL-1=Fixture Loop
SHK=Hook with Safety Screw
PC3=3' Cord for with NEMA Plugs (120V-L5-15P, 208V-L6-15P, 240V-L6-15P, 277V-L7-15P, 347V-L37-20P and
480V-L8-20P) Other Lengths Available. Requires FH-1 or FL-1. Use with TPPH-NEMA.
(Specify Single Voltage)
Accessories (order separately)
FH-1=Fixture Hook
FL-1=Fixture Loop
SHK=Hook with Safety Screw
PC3-XXXV=3' Cord with NEMA Plug—(120V-L5-15P, 208V-L6-15P, 240V-L6-15P, 347V-L37-20P, and
480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6’ cord).
Requires FH-1 or FL-1
PHC-XXXV=Power Cord and Plug—18" Power Cord and Non-NEMA plug configuration. Must be used with
FL-1 and TPPH (Thru-Way Pendant Power Hook). Must Specify Single Voltage
PHC-XXXV-NEMA=Power Cord and NEMA Plug—18" Power Cord and 20 Amp NEMA plug configuration.
Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook)
Power Factor
H=HPF
_ =NPF 4
Voltage 5
120V
208V
240V
277V
347V
480V 6
MT=Multi-Tap 7
TT=Triple-Tap 8
Lamp Included
Options &
Accessories
(See Below)
PHC=Power Cord and Plug (18" cord, non-NEMA plug requires FL-1 and TPPH)
C3=3' Cord-No Plug-Requires FH-1 or FL-1. Specify Voltage
HC=LumaWatt Fixture Control Module (Low voltage leads pulled out of top connection box for areas
requiring all wiring to be installed in conduit) 10, 12
SCF=3' Safety Chain–Housing to Ceiling
WLB=U.L. Labeled for Wet Locations with Die-Cast Box for 3/4" Conduit Entry
WLD=U.L. Labeled for Wet Locations with Quick-Disconnect
WLP=U.L. Labeled for Wet Locations Suitable for Surface or 4" J-Box Mounting
P=Mounting Bracket for Surface Mounting or Mounting to 4" J-Box
MWS=Modular Wiring Systems Available. Consult Factory
LL=Lamp Included
TPPH-XXXV-NEMA=Thru-way Pendant Power Hook. Requires FL-1 and PHC-XXXV-NEMA. Specify Voltage
TPPH-XXXV=Thru-Way Pendant Power Hook–Requires Loop, Cordand Twist Lock Plug. Specify Voltage
TPPH-F-XXXV=Thru-Way Pendant Power Hook Single Fuse, 120 or 277 Volt. Specify Voltage
TPPH-F2-XXXV=Thru-Way Pendant Power Hook–Double Fused, 208, 240 or 480 Volt. Specify Voltage
TPPH-F-QD-XXXV=Thru-Way Pendant Power Hook–Single Fuse, Quick Disconnect. Specify Voltage
TPPH-F2-QD-XXXV=Thru-Way Pendant Power Hook–Double Fused, Quick Disconnect. Specify Voltage
C3=3' Cord-No Plug-Requires FH-1 or FL-1
MBT=Twin Mount Bracket (Fixtures must be same voltage and without hooks, loops or plugs)
IA1025=Mounting Bracket for Surface Mounting to 4" J-Box
(Field Installed)
NOTES: 1 150W is maximum wattage available in HPS. 2 Pulse Start Metal Halide avialable on 100, 150, 175, 200, & 250W only. 3 Not recommended for use with Metal Halide lamps due to to rapid yellowing typical of
polycarbonate material. 4 For 120V NPF Reactor ballast, drop “H” after wattage in catalog number. 5 Products also available in non-US voltages and 50Hz for international markets. Consult factory for availability and
ordering information. 6 480V not available with 200 or 250W Pulse Start Metal Halide. 7 Multi-Tap ballast is 120/208/240/277V wired 277V. 8 Triple-Tap ballast is 120/277/347V wired 347V. 9 Must be listed in the order
shown and seperated by a dash. 10 Consult individual lamp manufacturers recommendations for compatible lamps. For use with CWA ballast only. 11 Quartz lamp wattage is 100W maxium. 12 Not available with
QD, PC3, C3, PHC or MWS.
NOTE: Specifications and dimensions subject to change without notice.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
ADH041465
Download