TYPE: C AT A L O G # : DESCRIPTION S P E C I F I C AT I O N F E AT U R E S The Vertimark II delivers horizontal and vertical footcandles to evenly illuminate parking garage areas. The combination die-cast reflector/ ballast housing makes Vertimark II economical. Modular assembly makes installation easy and quality construction ensures years of consistent performance. U.L. listed and labeled for damp location. CSA Certified. A ...P e n d a n t M o u n t i n g E ...B a l l a s t C o m p a r t m e n t Standard quick mounting plate for 3/4" IPS conduit frees both hands to complete wiring. Removable ballast compartment cover provides easy internal access. B ...H o u s i n g F ...O p t i o n a l J - B o x M o u n t i n g Die-cast aluminum housing has durable white polyester powder coat finish. Factory-installed mounting bracket fits a standard 4" J-Box for outlet box or surface mounting. A P P L I C AT I O N COOPER LIGHTING—LUMARK C ...R e f r a c t o r H i n g e Hinged refractor permits relamping without removal of refractor. BEVERTIMARK II D ...R e f r a c t o r Durable construction and dependable performance make the Vertimark II perfect for parking garages. U.L. listed and CSA certified for indoor applications. Optional U.L. wet location listing available. Acrylic prismatic refractor controls light for high vertical and horizontal footcandles. 1 0 0 - 2 5 0 W High Pressure Sodium Pulse Start Metal Halide Metal Halide L O W - B AY INDUSTRIAL LUMINAIRE A B C Surface 12 1/2" [318mm] Pendant 13 1/4" [337mm] D E 17" [432mm] OPTIONAL J-BOX S TA N D A R D E Z 1 2 3 M O U N T I N G E N E R G Y D AT A 3/4" [19mm] High-Reactance Ballast Input Watts 100W HPS HPF (130 Watts) 150W HPS HPF (190 Watts) Once in place, the EZ123 readily accepts the mating half of the hinge and the fixture is easily attached. 2 9/16" [65mm] 5 1/8" [130mm] S H I P P I N G D AT A Approximate Net Weight: 17 lbs. (8 kgs.) ADH041465 C COOPER LIGHTING YS ER T EM S S 5 1/8" [130mm] 2 9/16" [65mm] CWA Ballast Input Watts 175W MH HPF (210 Watts) 250W MH/MV HPF (295 Watts) D 3/4" [19mm] Reactor Ballast Input Watts 70W HPS NPF/HPF (82 Watts) 100W HPS HPF (118 Watts) 150W HPS HPF (175 Watts) TIFIE ® B E VERTIMARK II PHOTOMETRICS 90° 5 10 15 60° 20 25 30 30° 35 40 45 50 CP/100 H P B E - 5 A - 1 5 0 H - 1 2 0 V- L L 150-Watt HPS 16,000-Lumen Clear Lamp Spacing Criterion 1.6 Zone %Lamp Zone 0-30 11.67 0-90 0-40 19.95 90-180 0-60 53.54 Total 90° 5 10 15 25 30° 35 40 45 50 CP/100 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 76 61 50 40 33 28 23 19 16 13 78 67 58 51 47 39 324 30 27 24 72 62 54 47 41 36 31 28 25 22 66 57 50 43 37 33 29 25 23 20 58 47 39 31 26 21 17 14 12 9 0% Candlepower Degree CP 0 1651 74 62 52 44 37 32 27 23 20 17 71 57 47 38 31 26 22 18 16 13 69 58 49 41 35 30 25 22 19 16 66 54 44 36 30 25 20 17 15 12 64 54 45 38 32 28 23 20 18 15 62 50 42 34 28 23 19 16 14 11 %Lamp 77.41 14.83 92.23 50% 30% 10% 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 85 72 61 52 45 40 35 31 28 25 82 69 59 50 43 38 34 30 27 24 75 64 44 46 40 35 31 28 25 22 70 59 50 42 36 32 29 26 23 21 64 54 46 39 33 29 26 23 21 19 56 44 34 27 21 17 14 12 10 8 80 65 53 43 36 31 26 23 20 17 75 58 46 36 29 24 20 17 15 12 Spacing Criterion 1.7 Zone %Lamp Zone 0-30 10.12 0-90 0-40 16.69 90-180 0-60 41.74 Total M H B E - 5 A - 1 7 5 H - M T- L L 175-Watt MH 14,000-Lumen Clear Lamp 10 Candlepower Degree CP 0 2113 5 1888 15 1748 25 2308 35 2003 45 2329 55 3855 65 1964 75 1020 85 845 90 787 Coefficients Of Utilization Effective floor cavity reflectance = 20% rc 80% 70% rw RCR 1 2 3 4 5 6 7 8 9 10 60° 20 30 Coefficients Of Utilization Effective floor cavity reflectance = 20% rc 80% 70% rw 50 30 10 50 30 RCR 1 88 83 79 85 80 2 76 69 63 73 66 3 66 58 51 63 56 4 57 48 41 55 47 5 50 41 34 48 39 6 44 35 28 42 34 7 38 30 23 37 29 8 34 25 20 33 25 9 31 22 17 29 22 10 29 19 14 26 18 77 62 51 42 34 30 25 22 20 17 73 56 44 35 28 23 19 14 14 12 72 58 54 39 32 28 24 21 18 16 68 53 48 33 26 22 18 16 14 11 66 54 44 36 30 26 22 19 17 15 63 50 40 31 25 21 17 15 13 10 62 50 41 33 28 24 21 18 16 14 59 47 37 29 23 19 16 14 12 10 5 15 25 35 45 55 65 75 85 90 1463 1362 1772 1388 1595 2087 3456 1020 810 637 %Lamp 76.90 13.16 90.05 O R D E R I N G I N F O R M AT I O N S A M P L E N U M B E R : H P B E - 5 A - 1 0 0 H - M T- L L BE Lamp Type Series HP=High BE=Vertimark II Pressure 1 Sodium MH=Metal Halide MP=Pulse Start MH (CWA) 2 Lens Type 2A=Type II 5A=Type V 2P=Type II Polycarbonate 3 5P=Type V Polycarbonate 3 Lamp Wattage 100=100W 150=150W 175=175W 200=200W 250=250W Options (add as suffix) 9 HL=LumaWatt Fixture Control Module (Allows low voltage control wire to be daisey-chained between fixtures outside AC conduit run similar to low voltage intercoms, fire alarms and phone systems) 10 Q=Quartz Restrike DC Bayonet Base (Hot strike only) 11 EM=Quartz Restrike with “Delay Relay”– Housing Mounted (dry locations only) 11 EM/SC=Emergency Separate Circuit– Reflector Mounted 11 F1=Single Fuse—120, 277 or 347V (Specify single voltage only) F2=Double Fused—208, 240 or 480V (Specify single voltage only) FH-1=Fixture Hook FL-1=Fixture Loop SHK=Hook with Safety Screw PC3=3' Cord for with NEMA Plugs (120V-L5-15P, 208V-L6-15P, 240V-L6-15P, 277V-L7-15P, 347V-L37-20P and 480V-L8-20P) Other Lengths Available. Requires FH-1 or FL-1. Use with TPPH-NEMA. (Specify Single Voltage) Accessories (order separately) FH-1=Fixture Hook FL-1=Fixture Loop SHK=Hook with Safety Screw PC3-XXXV=3' Cord with NEMA Plug—(120V-L5-15P, 208V-L6-15P, 240V-L6-15P, 347V-L37-20P, and 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6’ cord). Requires FH-1 or FL-1 PHC-XXXV=Power Cord and Plug—18" Power Cord and Non-NEMA plug configuration. Must be used with FL-1 and TPPH (Thru-Way Pendant Power Hook). Must Specify Single Voltage PHC-XXXV-NEMA=Power Cord and NEMA Plug—18" Power Cord and 20 Amp NEMA plug configuration. Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook) Power Factor H=HPF _ =NPF 4 Voltage 5 120V 208V 240V 277V 347V 480V 6 MT=Multi-Tap 7 TT=Triple-Tap 8 Lamp Included Options & Accessories (See Below) PHC=Power Cord and Plug (18" cord, non-NEMA plug requires FL-1 and TPPH) C3=3' Cord-No Plug-Requires FH-1 or FL-1. Specify Voltage HC=LumaWatt Fixture Control Module (Low voltage leads pulled out of top connection box for areas requiring all wiring to be installed in conduit) 10, 12 SCF=3' Safety Chain–Housing to Ceiling WLB=U.L. Labeled for Wet Locations with Die-Cast Box for 3/4" Conduit Entry WLD=U.L. Labeled for Wet Locations with Quick-Disconnect WLP=U.L. Labeled for Wet Locations Suitable for Surface or 4" J-Box Mounting P=Mounting Bracket for Surface Mounting or Mounting to 4" J-Box MWS=Modular Wiring Systems Available. Consult Factory LL=Lamp Included TPPH-XXXV-NEMA=Thru-way Pendant Power Hook. Requires FL-1 and PHC-XXXV-NEMA. Specify Voltage TPPH-XXXV=Thru-Way Pendant Power Hook–Requires Loop, Cordand Twist Lock Plug. Specify Voltage TPPH-F-XXXV=Thru-Way Pendant Power Hook Single Fuse, 120 or 277 Volt. Specify Voltage TPPH-F2-XXXV=Thru-Way Pendant Power Hook–Double Fused, 208, 240 or 480 Volt. Specify Voltage TPPH-F-QD-XXXV=Thru-Way Pendant Power Hook–Single Fuse, Quick Disconnect. Specify Voltage TPPH-F2-QD-XXXV=Thru-Way Pendant Power Hook–Double Fused, Quick Disconnect. Specify Voltage C3=3' Cord-No Plug-Requires FH-1 or FL-1 MBT=Twin Mount Bracket (Fixtures must be same voltage and without hooks, loops or plugs) IA1025=Mounting Bracket for Surface Mounting to 4" J-Box (Field Installed) NOTES: 1 150W is maximum wattage available in HPS. 2 Pulse Start Metal Halide avialable on 100, 150, 175, 200, & 250W only. 3 Not recommended for use with Metal Halide lamps due to to rapid yellowing typical of polycarbonate material. 4 For 120V NPF Reactor ballast, drop “H” after wattage in catalog number. 5 Products also available in non-US voltages and 50Hz for international markets. Consult factory for availability and ordering information. 6 480V not available with 200 or 250W Pulse Start Metal Halide. 7 Multi-Tap ballast is 120/208/240/277V wired 277V. 8 Triple-Tap ballast is 120/277/347V wired 347V. 9 Must be listed in the order shown and seperated by a dash. 10 Consult individual lamp manufacturers recommendations for compatible lamps. For use with CWA ballast only. 11 Quartz lamp wattage is 100W maxium. 12 Not available with QD, PC3, C3, PHC or MWS. NOTE: Specifications and dimensions subject to change without notice. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH041465