Lumark DESCRIPTION The BenchMark HB utilizes a durable heavy duty die-cast aluminum ballast housing and computer aided designed reflector system for specification-level performance at higher mounting heights. U.L. listed and CSA certified. Damp location standard. Catalog # The BenchMark HB is perfect for high-bay applications such as gymnasiums, hangars, manufacturing, assembly and auto service areas. Comments Type Project Date Prepared by SPECIFICATION FEATURES A ... Mounting Easy slide-on die-cast aluminum mounting box with tapped opening for 3/4" conduit. B ... Housing Durable heavy-duty die-cast aluminum housing for lasting performance in the harshest environments. Integrally hinged for ease of maintenance with optional toolless entry. Finished in a white polyester powder coat. C ... Ballast High power factor ballast with class H insulation. Minimum starting temperature is -40°C (-40°F) for HPS and -30°C (-20°F) for MH. D ... Socket Mogul-base socket standard for HPS. For Metal Halide, protected socket standard, for use with "O" rated protected Metal Halide lamps only. E ... Universal Brackets Universal ladder brackets allow for the flexibility to change out with other reflectors available in acrylic or glass. F ... Reflector Computer aided designed, field-adjustable reflector mounts easily and allows multiple distribution patterns for precise control. Special contours and unique system of facets minimizes arc tube voltage rise. HB HIGH-BAY BENCHMARK 175 - 1000W High Pressure Sodium Pulse Start Metal Halide Metal Halide A DIE-CAST ALUMINUM HIGH-BAY HEAVY-DUTY INDUSTRIAL LUMINAIRE B C T E C H N I C A L D AT A EISA Compliant 65° Ambient Environment Maximum height with 18" reflector is 29 3/16" [741mm]. Maximum height with 23" reflector is 32 13/16" [833mm]. See ordering information for more details. D E 55° Ambient Environment (400W and Up) 105° Supply Wire Rating E N E R G Y D AT A CWI Ballast Input Watts 250W HPS HPF (300 Watts) 250W MH HPF (300 Watts) 400W HPS HPF (465 Watts) 400W MH HPF (475 Watts) CWA Ballast Input Watts 200W MP HPF (227 Watts) 250W MP HPF (283 Watts) 320W MP HPF (365 Watts) 350W MP HPF (400 Watts) 400W MP HPF (452 Watts) 400W HPS HPF (465 Watts) 450W MP HPF (508 Watts) 600W HPS HPF (665 Watts) 750W HPS HPF (850 Watts) 750W MP HPF (820 Watts) 1000W HPS HPF (1100 Watts) 1000W MH HPF (1085 Watts) 1000W MP HPF (1070 Watts) F S H I P P I N G D AT A C ER T EM D S YS S 23" [584mm] 18" [457mm] Approximate Net Weight: 35 lbs. (15 kgs.) TIFIE ADH082362 12/02/2015 10:45:51 AM HB HIGH-BAY BENCHMARK ORDERING INFORMATION Sample Number: MPHB-SA15-C-250-120V Lamp Type MP=Pulse Start Metal 1 Halide MH=Metal Halide1, 2 HP=High Pressure 3 Sodium Series HB=High-Bay Benchmark Reflector Type SA=Anodized Spun Aluminum Lamp Wattage Voltage 8 120V=120V Options C3=3' Cord with no plug (Specify Voltage) Accessories 16 C3=3' Cord-No Plug - Requires MP 208V=208V 240V=240V PC3=3' Cord with NEMA Plug (120V-L5-15P, 208V-L6-15P, 347V-L37-20P, AND 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6' Cord) Requires FH-1 or FL-1, or SHK. Example: PC3-120V Use with TPPH-NEMA. Specify Voltage. PC3=3' Cord with NEMA Plug (120V-L5, 208V-L6-15P, 347V-L37-20P and 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6' cord). Requires FH-1 or FL-1, or SHK. Use with 175=175W 200=200W Reflector Diameter 15=15'' Diameter 250=250W 320=320W 18=18'' Diameter 23=23'' Diameter 350=350W 400=400W 4 Distribution C=Concentrated M=Medium W=Wide 480V=480V MT=Multi-Tap, wired9 277V 450=450W 750=750W TT=Triple-Tap, 347V 1000=1000W5 5T=5-Tap11 MH wired 10 2 175=175W 250=250W 400=400W 1000=1000W6 HP 250=250W 400=400W 600=600W7 1000=1000W Notes: 1 277V=277V 347V=347V Socket 12 OR=Open Rated Socket for Metal Halide Lamps __=Non Applicable (HPS or Not compatible with OR Socket) Open Rated socket and lamp must be used. PHC=Power Cord and Plug (18" Power Cord and Non-NEMA plug configuration. Must be used with FL-1 and TPPH (Thru-Way Pendant Power Hook). Must specify single voltage. PHC-NEMA=Power Cord and NEMA Plug (18" Power Cord and 20 AMP NEMA plug configuration). Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook). PS=Protective Starter (Available in 1000W HPS only. For other wattages consult factory). P=Pre-set Socket Position from the factory FH-1=Die-cast Aluminum Fixture Hook (with 3/4" threads for easy installation) FL-1=Malleable Iron Plated Fixture Loop (with 3/4" threads for easy installation) Factory set for concentrated, medium or wide distributions only if P (factory pre-set) is in the nomenclature of the fixture. Otherwise fixture is shipped in medium setting. 5 MP 1000W uses standard socket and SGB is required. 6 Available with open-rate socket only. 7 High Pressure Sodium only. F1=Single Fuse (120, 277 or 347V only) F2=Double Fuse (208, 240 or 480V only) 8 Products also available in non-US voltages and 50HZ for international markets. Consult your Cooper Representative for availabiltiy and ordering information. 88% Efficient EISA Compliant MP Fixtures not available in 347V and TT Voltages. SCF=3' Aircraft Safety Cable secures Housing to Ceiling (Alternative lengths available. Example: SCF6 = 6' Cable) 9 Multi-Tap ballast 120/208/240/277V wired 277V. 10 Triple-Tap ballast 120/277/347V wired 347V. 11 5-Tap ballast 120/208/240/277/480V wired 277V. 400W Metal Halide only. 88% efficient EISA Compliant MP fixtures not available in 5-Tap Voltages. 12 Not applicable for HPS. 13 30 second time delay when switching from bright to dim. Consult individual lamp manufacturers recommendations for compatible lamps. For use with CWA ballast only. 14 Not available with HL or HC options. 15 Lamp is shipped separately. 16 Order separately. 17 Specify L/TCB when using thru-way mounting box (TWMBS) accessory. Q=Quartz Restrike (Hot Strike Only) EM=Quartz Restrike with ''Delay Relay'' (Quartz lamp strikes at both hot and cold starts) EM/SC=Emergency Separate Circuit14 L/TCB=Less Top Connector Box (Housing shipped less top connector box. (Specify when using TWMBS accessory) LL=Lamp Included15 DL100=100% Downlight (Available on SA18 or SA23 aluminum reflectors only). SCR=Aircraft Safety Cable-Housing to Reflector TE=Toolless Entry W/MWS=MWS Industrial components attached to the fixture at the factory. (Standard cord length is 3 ft. 6 ft. and 11 ft. also available. Please refer to MWS Modular Wiring System section for additional information. HC=LumaWatt Fixture Control Module (Low13 voltage leads pulled out of top connection box for areas requiring all wiring to be installed in conduit) Metal Halide (MH) 175, 250, 400, 1000W High Pressure Sodium (HP) 250, 400, 600, 750W MT= Multi-Tap 120/208/240/277V (wired 277V) TT= Triple-Tap 120/277/347V (wired 347V) 5T= 5-Tap SGB23=Safety Glass Bottom WG15=Wire Guard (Not Compatible with "SGB15") WG18=Wire Guard 13 HL=LumaWatt Fixture Control Module (Allows low voltage control wire to be daisy-chained between fixtures outside AC conduit run similar to low voltage intercom's, fire alarms and phone systems) WG15/GLC=Gym Wireguard w/ Safety Glass WG23/GLC=Gym Wireguard w/ Safety Glass MBT=Twin Mount Bracket (Fixtures must be same voltage and without hooks, loops or plugs.) TPPH=Thru-Way Pendant Power Hook. Requires FL-1 and PHC. Specify Voltage. TPPH-F=Thru-Way Pendant Power Hook Single Fuse, 120, 277 or 347 Volt. Requires FL-1 and PHC. Specify Voltage. TPPH-F2=Thru-Way Pendant Power Hook - Double Fused, 208, 240, or 480 Volt. Requires FL-1 and PHC. Specify Voltage. TPPH-F-QD=Thru-Way Pendant Power Hook Single Fuse, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage (120, 277, or 347V) TPPH-F2-QD=Thru-Way Pendant Power Hook Double Fuse, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage (208, 240, or 480V) TPPH-NEMA=Thru-Way Pendant Power Hook. Requires FL-1 and PHC-XXXV-NEMA. (Specify Voltage). FH-1=Fixture Hook FL-1=Fixture Loop SHK=Hook with Safety Screw TW=Thru-Way Mounting Box17 QLL=Quartz Lamp Included (Lamp is Cooper designated product based on luminaire requirements. Lamp is shipped separate from luminaire unless otherewise noted) VOLTAGE CHART 10 SGB18=Safety Glass Bottom WG18/GLC=Gym Wireguard w/ Safety Glass Not available in 175, 200, 320, 350, 450 and 750W. 4 175, 200, 250, 320, 350, 400, 450, 750, 1000W SGB15=Safety Glass Bottom (Not Compatiable with "WG15") QB=Quiet Ballast HSW=Integral LumaWatt Sensor and Control 13 w/ Wide Distribution 3 Pulse Start Metal Halide (MP) PHC-NEMA=Power Cord and NEMA plug - 18" Power Cord and 20 Amp NEMA plug configuration. Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook) WG23=Wire Guard MH available in non-U.S. markets only. WATTAGE PHC=Power Hook Cord and Non-NEMA plug configuration. Must be used with FL-1 and TPPH (Thru-Way Pendant Power SHK=Die-cast Aluminum Fixture Hook (with safety screw and 3/4" threads for easy installation) 2 LAMP TYPE FH-1, FL-1, or SHK 120/208/240/277/480V (wired 277V) Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. ADH082362 12/02/2015 10:45:51 AM HB HIGH-BAY BENCHMARK PHOTOMETRICS 90 6.1 8.5 11.0 60 13.4 15.8 18.3 CP/1000 M P H B - S A1 8 - W - 4 0 0 - 1 2 0 V 400-Watt MP 44,000-Lumen Clear Lamp 30 Coefficients Of Utilizatio Effective floor cavity eflectanc rc 80% 70% rw 70 50 30 10 70 50 30 10 RCR 1 93 90 88 85 91 88 86 84 2 87 82 78 74 85 80 76 73 3 81 74 69 64 79 72 67 63 4 75 67 61 56 73 66 60 56 5 69 60 54 49 67 59 53 49 6 64 54 47 43 62 53 47 42 7 58 48 41 36 57 47 41 36 8 54 43 36 32 52 42 36 31 9 49 38 32 32 48 38 31 27 10 45 34 28 23 44 34 27 23 Spacing Criterion 1.6 Zone %Lamp Zone 0-30 22.60 0-90 0-40 44.70 90-180 0-60 77.10 Total Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 84 77 69 63 57 51 45 41 36 32 80 73 67 61 55 49 44 39 35 31 76 70 64 58 53 48 42 38 34 30 82 73 65 58 52 46 40 35 31 27 %Lamp 80.10 4.40 84.40 80 71 62 54 48 42 36 31 27 23 78 71 63 57 50 44 39 34 30 26 77 68 60 53 47 41 35 30 26 22 75 68 61 55 49 43 38 33 29 26 74 66 59 52 46 40 35 30 26 22 0% 0 72 65 57 51 44 39 33 28 24 21 Candlepower Degree CP 0 11865 5 10899 15 9920 25 13027 35 15770 45 11392 55 6349 65 1030 75 133 85 12 90 1 2 95 105 7 115 13 125 37 135 104 145 1581 155 1569 165 161 175 43 180 40 ADH082362 12/02/2015 10:45:51 AM