Catalog # Type

advertisement
Lumark
DESCRIPTION
The BenchMark HB utilizes a durable heavy duty die-cast aluminum ballast
housing and computer aided designed reflector system for
specification-level performance at higher mounting heights. U.L. listed and
CSA certified. Damp location standard.
Catalog #
The BenchMark HB is perfect for high-bay applications such as
gymnasiums, hangars, manufacturing, assembly and auto service areas.
Comments
Type
Project
Date
Prepared by
SPECIFICATION FEATURES
A ... Mounting
Easy slide-on die-cast aluminum
mounting box with tapped opening
for 3/4" conduit.
B ... Housing
Durable heavy-duty die-cast
aluminum housing for lasting
performance in the harshest
environments. Integrally hinged for
ease of maintenance with optional
toolless entry. Finished in a white
polyester powder coat.
C ... Ballast
High power factor ballast with
class H insulation. Minimum
starting temperature is -40°C
(-40°F) for HPS and -30°C (-20°F)
for MH.
D ... Socket
Mogul-base socket standard for
HPS. For Metal Halide, protected
socket standard, for use with "O"
rated protected Metal Halide lamps
only.
E ... Universal Brackets
Universal ladder brackets allow for
the flexibility to change out with
other reflectors available in acrylic
or glass.
F ... Reflector
Computer aided designed,
field-adjustable reflector mounts
easily and allows multiple
distribution patterns for precise
control. Special contours and
unique system of facets minimizes
arc tube voltage rise.
HB
HIGH-BAY
BENCHMARK
175 - 1000W
High Pressure Sodium
Pulse Start Metal Halide
Metal Halide
A
DIE-CAST ALUMINUM
HIGH-BAY
HEAVY-DUTY
INDUSTRIAL LUMINAIRE
B
C
T E C H N I C A L D AT A
EISA Compliant
65° Ambient Environment
Maximum height with 18"
reflector is 29 3/16" [741mm].
Maximum height with 23"
reflector is 32 13/16" [833mm].
See ordering information
for more details.
D
E
55° Ambient Environment
(400W and Up)
105° Supply Wire Rating
E N E R G Y D AT A
CWI Ballast Input Watts
250W HPS HPF (300 Watts)
250W MH HPF (300 Watts)
400W HPS HPF (465 Watts)
400W MH HPF (475 Watts)
CWA Ballast Input Watts
200W MP HPF (227 Watts)
250W MP HPF (283 Watts)
320W MP HPF (365 Watts)
350W MP HPF (400 Watts)
400W MP HPF (452 Watts)
400W HPS HPF (465 Watts)
450W MP HPF (508 Watts)
600W HPS HPF (665 Watts)
750W HPS HPF (850 Watts)
750W MP HPF (820 Watts)
1000W HPS HPF (1100 Watts)
1000W MH HPF (1085 Watts)
1000W MP HPF (1070 Watts)
F
S H I P P I N G D AT A
C
ER
T EM
D
S
YS
S
23" [584mm]
18" [457mm]
Approximate Net Weight:
35 lbs. (15 kgs.)
TIFIE
ADH082362
12/02/2015 10:45:51 AM
HB HIGH-BAY BENCHMARK
ORDERING INFORMATION
Sample Number: MPHB-SA15-C-250-120V
Lamp Type
MP=Pulse Start Metal 1
Halide
MH=Metal Halide1, 2
HP=High Pressure 3
Sodium
Series
HB=High-Bay Benchmark
Reflector Type
SA=Anodized Spun
Aluminum
Lamp
Wattage
Voltage 8
120V=120V
Options
C3=3' Cord with no plug (Specify Voltage)
Accessories 16
C3=3' Cord-No Plug - Requires
MP
208V=208V
240V=240V
PC3=3' Cord with NEMA Plug (120V-L5-15P,
208V-L6-15P, 347V-L37-20P, AND
480V-L8-20P) Other cord lengths are
available by specifying length (PC6 for 6'
Cord) Requires FH-1 or FL-1, or SHK.
Example: PC3-120V Use with
TPPH-NEMA. Specify Voltage.
PC3=3' Cord with NEMA Plug (120V-L5, 208V-L6-15P,
347V-L37-20P and
480V-L8-20P) Other cord
lengths are available by
specifying length (PC6 for 6'
cord). Requires FH-1 or FL-1,
or SHK. Use with
175=175W
200=200W
Reflector
Diameter
15=15'' Diameter
250=250W
320=320W
18=18'' Diameter
23=23'' Diameter
350=350W
400=400W
4
Distribution
C=Concentrated
M=Medium
W=Wide
480V=480V
MT=Multi-Tap, wired9
277V
450=450W
750=750W
TT=Triple-Tap,
347V
1000=1000W5
5T=5-Tap11
MH
wired 10
2
175=175W
250=250W
400=400W
1000=1000W6
HP
250=250W
400=400W
600=600W7
1000=1000W
Notes: 1
277V=277V
347V=347V
Socket
12
OR=Open
Rated
Socket for
Metal
Halide
Lamps
__=Non
Applicable
(HPS or Not
compatible
with OR
Socket)
Open Rated socket and lamp must be used.
PHC=Power Cord and Plug (18" Power Cord
and Non-NEMA plug configuration. Must
be used with FL-1 and TPPH (Thru-Way
Pendant Power Hook). Must specify
single voltage.
PHC-NEMA=Power Cord and NEMA Plug (18"
Power Cord and 20 AMP NEMA
plug configuration). Must be
used with FL-1 and TPPH-NEMA
(Thru-Way Pendant Power
Hook).
PS=Protective Starter (Available in 1000W HPS
only. For other wattages consult factory).
P=Pre-set Socket Position from the factory
FH-1=Die-cast Aluminum Fixture Hook (with
3/4" threads for easy installation)
FL-1=Malleable Iron Plated Fixture Loop (with
3/4" threads for easy installation)
Factory set for concentrated, medium or wide distributions only if P (factory pre-set) is in the nomenclature of the
fixture. Otherwise fixture is shipped in medium setting.
5
MP 1000W uses standard socket and SGB is required.
6
Available with open-rate socket only.
7
High Pressure Sodium only.
F1=Single Fuse (120, 277 or 347V only)
F2=Double Fuse (208, 240 or 480V only)
8
Products also available in non-US voltages and 50HZ for international markets. Consult your Cooper
Representative for availabiltiy and ordering information. 88% Efficient EISA Compliant MP Fixtures not available in
347V and TT Voltages.
SCF=3' Aircraft Safety Cable secures
Housing to Ceiling (Alternative lengths
available. Example: SCF6 = 6' Cable)
9
Multi-Tap ballast 120/208/240/277V wired 277V.
10
Triple-Tap ballast 120/277/347V wired 347V.
11
5-Tap ballast 120/208/240/277/480V wired 277V. 400W Metal Halide only. 88% efficient EISA Compliant MP fixtures
not available in 5-Tap Voltages.
12
Not applicable for HPS.
13
30 second time delay when switching from bright to dim. Consult individual lamp manufacturers
recommendations for compatible lamps. For use with CWA ballast only.
14
Not available with HL or HC options.
15
Lamp is shipped separately.
16
Order separately.
17
Specify L/TCB when using thru-way mounting box (TWMBS) accessory.
Q=Quartz Restrike (Hot Strike Only)
EM=Quartz Restrike with ''Delay Relay'' (Quartz
lamp strikes at both hot and cold starts)
EM/SC=Emergency Separate Circuit14
L/TCB=Less Top Connector Box (Housing
shipped less top connector box.
(Specify when using TWMBS
accessory)
LL=Lamp Included15
DL100=100% Downlight (Available on SA18 or
SA23 aluminum reflectors only).
SCR=Aircraft Safety Cable-Housing to
Reflector
TE=Toolless Entry
W/MWS=MWS Industrial components attached
to the fixture at the factory. (Standard
cord length is 3 ft. 6 ft. and 11 ft. also
available. Please refer to MWS
Modular Wiring System section for
additional information.
HC=LumaWatt Fixture Control Module (Low13
voltage leads pulled out of top
connection box for areas requiring all
wiring to be installed in conduit)
Metal Halide (MH)
175, 250, 400, 1000W
High Pressure Sodium (HP)
250, 400, 600, 750W
MT= Multi-Tap
120/208/240/277V (wired 277V)
TT= Triple-Tap
120/277/347V (wired 347V)
5T= 5-Tap
SGB23=Safety Glass Bottom
WG15=Wire Guard (Not Compatible
with "SGB15")
WG18=Wire Guard
13
HL=LumaWatt Fixture Control Module
(Allows low voltage control wire to be
daisy-chained between fixtures outside
AC conduit run similar to low voltage
intercom's, fire alarms and phone
systems)
WG15/GLC=Gym Wireguard w/
Safety Glass
WG23/GLC=Gym Wireguard w/
Safety Glass
MBT=Twin Mount Bracket (Fixtures
must be same voltage and
without hooks, loops or plugs.)
TPPH=Thru-Way Pendant Power
Hook. Requires FL-1 and
PHC. Specify Voltage.
TPPH-F=Thru-Way Pendant Power
Hook Single Fuse, 120,
277 or 347 Volt. Requires
FL-1 and PHC. Specify
Voltage.
TPPH-F2=Thru-Way Pendant Power
Hook - Double Fused,
208, 240, or 480 Volt.
Requires FL-1 and PHC.
Specify Voltage.
TPPH-F-QD=Thru-Way Pendant
Power Hook Single
Fuse, Quick
Disconnect. Requires
FL-1 and PHC.
Specify Voltage (120,
277, or 347V)
TPPH-F2-QD=Thru-Way Pendant
Power Hook Double
Fuse, Quick
Disconnect. Requires
FL-1 and PHC.
Specify Voltage (208,
240, or 480V)
TPPH-NEMA=Thru-Way Pendant
Power Hook.
Requires FL-1 and
PHC-XXXV-NEMA.
(Specify Voltage).
FH-1=Fixture Hook
FL-1=Fixture Loop
SHK=Hook with Safety Screw
TW=Thru-Way Mounting Box17
QLL=Quartz Lamp Included (Lamp is Cooper
designated product based on luminaire
requirements. Lamp is shipped separate
from luminaire unless otherewise noted)
VOLTAGE CHART
10
SGB18=Safety Glass Bottom
WG18/GLC=Gym Wireguard w/
Safety Glass
Not available in 175, 200, 320, 350, 450 and 750W.
4
175, 200, 250, 320, 350, 400, 450, 750, 1000W
SGB15=Safety Glass Bottom (Not
Compatiable with "WG15")
QB=Quiet Ballast
HSW=Integral LumaWatt Sensor and Control 13
w/ Wide Distribution
3
Pulse Start Metal Halide (MP)
PHC-NEMA=Power Cord and
NEMA plug - 18"
Power Cord and 20
Amp NEMA plug
configuration. Must be
used with FL-1 and
TPPH-NEMA
(Thru-Way Pendant
Power Hook)
WG23=Wire Guard
MH available in non-U.S. markets only.
WATTAGE
PHC=Power Hook Cord and
Non-NEMA plug
configuration. Must be used
with FL-1 and TPPH
(Thru-Way Pendant Power
SHK=Die-cast Aluminum Fixture Hook (with
safety screw and 3/4" threads for easy
installation)
2
LAMP TYPE
FH-1, FL-1, or SHK
120/208/240/277/480V (wired 277V)
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
ADH082362
12/02/2015 10:45:51 AM
HB HIGH-BAY BENCHMARK
PHOTOMETRICS
90
6.1
8.5
11.0
60
13.4
15.8
18.3
CP/1000
M P H B - S A1 8 - W - 4 0 0 - 1 2 0 V
400-Watt MP
44,000-Lumen Clear Lamp
30
Coefficients Of Utilizatio
Effective floor cavity eflectanc
rc
80%
70%
rw
70 50 30 10
70 50 30 10
RCR
1
93 90 88 85
91 88 86 84
2
87 82 78 74
85 80 76 73
3
81 74 69 64
79 72 67 63
4
75 67 61 56
73 66 60 56
5
69 60 54 49
67 59 53 49
6
64 54 47 43
62 53 47 42
7
58 48 41 36
57 47 41 36
8
54 43 36 32
52 42 36 31
9
49 38 32 32
48 38 31 27
10
45 34 28 23
44 34 27 23
Spacing Criterion
1.6
Zone
%Lamp
Zone
0-30
22.60
0-90
0-40
44.70
90-180
0-60
77.10
Total
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
84
77
69
63
57
51
45
41
36
32
80
73
67
61
55
49
44
39
35
31
76
70
64
58
53
48
42
38
34
30
82
73
65
58
52
46
40
35
31
27
%Lamp
80.10
4.40
84.40
80
71
62
54
48
42
36
31
27
23
78
71
63
57
50
44
39
34
30
26
77
68
60
53
47
41
35
30
26
22
75
68
61
55
49
43
38
33
29
26
74
66
59
52
46
40
35
30
26
22
0%
0
72
65
57
51
44
39
33
28
24
21
Candlepower
Degree CP
0
11865
5
10899
15
9920
25
13027
35
15770
45
11392
55
6349
65
1030
75
133
85
12
90
1
2
95
105
7
115
13
125
37
135
104
145
1581
155
1569
165
161
175
43
180
40
ADH082362
12/02/2015 10:45:51 AM
Download