S P E C I F I C AT I O N F E AT U R E S
Construction
Electrical
Optical
HOUSING: Heavy-duty, formed
steel housing with an open air
ballast for cooler operation is
finished in a white polyester
powder coat. UNIVERSAL
BRACKETS: Universal ladder
brackets allow for the flexibility to
change out with other reflectors
available in aluminum or glass.
BALLAST: High power factor ballast
with class H insulation. Minimum
starting temperature is -40°C (40°F) for HPS and -30°C (-20°F) for
MH. CSA certified. SOCKET:
Mogul-base socket standard for
HPS. For Metal Halide, protected
socket standard, for use with "O"
open-rated protected Metal Halide
lamps only.
REFLECTOR: Easily mounted
prismatic acrylic reflector has
multiple field-adjustable
distribution patterns for precision
control.
Mounting
Easy slide-on die-cast aluminum
mounting box with tapped opening
for 3/4" conduit.
SS
22"
PRISMATIC
175 - 450W
High Pressure Sodium
Pulse Start Metal Halide
Metal Halide
ACRYLIC HIGH-BAY
T E C H N I C A L D ATA
EISA Compliant G
40°C Maximum Ambient Environment.
90°C Minimum Supply Wiring.
DIMENSIONS
E N E R G Y D ATA
CWI Ballast Input Watts
250W HPS HPF (300 Watts)
250W MH HPF (300 Watts)
400W HPS HPF (465 Watts)
400W MH HPF (475 Watts)
S H I P P I N G D ATA
Approximate Net Weight:
42 lbs. (19 kgs.)
C
ER
TEM
S
YS
D
22” [559mm]
(Drop Bottom adds 3 1/2” to overall height.)
CWA Ballast Input Watts
175W MP HPF (198 Watts)
200W MP HPF (227 Watts)
250W MP HPF (283 Watts)
320W MP HPF (365 Watts)
350W MP HPF (400 Watts)
400W MP HPF (452 Watts)
400W HPS HPF (465 Watts)
450W MP HPF (508 Watts)
S
Maximum height
with PD22 is
28 1/2” [724mm]
TIFIE
ADH082400
2015-12-02 09:12:02
SS 22" PRISMATIC
ORDERING INFORMATION
Sample Number: MPSS-PD22-M-250-MT-OR-Q
Lamp Type
MP=Pulse Start Metal 1
Halide
Lamp
Wattage
Voltage 5
120V=120V
MH=Metal Halide1, 2
HP=High Pressure 3
Sodium
175=175W
250=250W
MP
320=320W
400=400W
Series
SS=Steeler
MH
2
175=175W
250=250W
Reflector Type
PD=Prismatic Acrylic
480V=480V
MT=Multi-Tap, 6
wired 277V
TT=Triple-Tap, 7
wired 347V
HP
5T=5-Tap8
Distribution
C=Concentrated
4
M=Medium
Socket
OR=Open Rated 9
Socket for
Metal
Halide
Lamps
__=Non
Applicable
(HPS or Not
compatible
with OR
Socket)
W=Wide
Notes: 1
277V=277V
347V=347V
400=400W
250=250W
400=400W
Reflector Diameter
22=22'' Diameter
208V=208V
240V=240V
Open Rated socket and lamp must be used.
Options
C3=3" cord with no plug. Other cord lengths
available by specifying length (C6 for 6'
Cord) (Must be used with FH-1 or FL-1)
(No Switching)
PC3=3' Cord with NEMA Plug (120V-L5-15P,
208V-L6-15P, 347V-L37-20P, AND
480V-L8-20P) Other cord lengths are
available by specifying length (PC6 for 6'
Cord) Requires FH-1 or FL-1, or SHK.
Example: PC3-120V Use with
TPPH-NEMA. Specify Voltage.
PHC=Power Cord and Plug (18" Power Cord
and Non-NEMA plug configuration. Must
be used with FL-1 and TPPH (Thru-Way
Pendant Power Hook). Must specify
single voltage.
PHC-NEMA=Power Cord and NEMA Plug (18"
Power Cord and 20 AMP NEMA
plug configuration). Must be
used with FL-1 and TPPH-NEMA
(Thru-Way Pendant Power
Hook).
P=Pre-set Socket Position from the factory
FH-1=Die-cast Aluminum Fixture Hook (with
3/4" threads for easy installation)
FL-1=Malleable Iron Plated Fixture Loop (with
3/4" threads for easy installation)
SHK=Die-cast Aluminum Fixture Hook (with
safety screw and 3/4" threads for easy
installation)
2
MH available in non-U.S. markets only.
3
Not available in 175, 200, 320 and 350W.
4
Factory set for concentrated, medium or wide distributions only if P (factory pre-set) is in the
nomenclature of the fixture. Otherwise fixture is shipped in medium setting.
5
Products also available in non-US voltages and 50HZ for international markets. Consult your
Cooper Representative for availabiltiy and ordering information. 88% Efficient EISA Compliant MP
Fixtures not available in 347V and TT Voltages.
6
Multi-Tap ballast 120/208/240/277V wired 277V.
7
Triple-Tap ballast 120/277/347V wired 347V.
8
5-Tap ballast 120/208/240/277/480V wired 277V. 400W Metal Halide only. 88% efficient EISA
Compliant MP fixtures not available in 5-Tap Voltages.
9
Not applicable for HPS.
10
30 second time delay when switching from bright to dim. Consult individual lamp manufacturers
recommendations for compatible lamps. For use with CWA ballast only.
11
12
13
Not available with PC3, C3, PHC or MWS. Not available with single circuit MWS special order.
14
Order separately.
15
Specify L/TCB when using thru-way mounting box (TWMBS) accessory.
HSW=Integral LumaWatt Sensor and Control 10
w/ Wide Distribution
F1=Single Fuse (120, 277 or 347V only)
F2=Double Fuse (208, 240 or 480V only)
SCF=3' Aircraft Safety Cable secures
Housing to Ceiling (Alternative lengths
available. Example: SCF6 = 6' Cable)
Accessories 14
C3=3' Cord-No Plug - Requires FH-1, FL-1, or
SHK
PC3=3' Cord with NEMA Plug - (120V-L5,
208V-L6-15P, 347V-L37-20P and
480V-L8-20P) Other cord lengths are
available by specifying length (PC6 for 6'
cord). Requires FH-1 or FL-1, or SHK. Use
with TPPH-NEMA. Specify Voltage.
PHC=Power Hook Cord and Non-NEMA plug
configuration. Must be used with FL-1 and
TPPH (Thru-Way Pendant Power Hook)
PHC-NEMA=Power Cord and NEMA plug - 18"
Power Cord and 20 Amp NEMA
plug configuration. Must be used
with FL-1 and TPPH-NEMA
(Thru-Way Pendant Power Hook)
SGB22A=(Not Compatible with WG22 - 400W
max.)
WG22/GLC=Gym Wireguard w/ Safety Glass
FWG22/WG22=Full Wire Guard for 22'' Reflector
FWG22/WDB=Wire Guard with DB22 Drop lens
for PD 22" Refractor - DB22 not
included
WG22=Wire Guard for AC22 or PD 22" Refractor
(Not compatible with SGB)
WGD22=Wire Guard for PD or AC22 or PC 22"
Refractor (Not Compatible with SGB22)
WG22/SGB22A=Wire guard with 22" Safety
glass bottom
FWG22/WDB=Full Wire Guard ("SGB" not
included)
FWG22/WG22/SGB22A=Full Wire Guard for
22" Reflector and
SGB22 lens (400W
Max.)
DB22=Drop Acrylic for 22" refractor (400W max.)
CB22=Conical Bottom for 22'' Refractor
(Maximum 400W).
MBT=Twin Mount Bracket (Fixtures must be same
voltage and without hooks, loops or plugs.)
TPPH=Thru-Way Pendant Power Hook. Requires
FL-1 and PHC. Specify Voltage.
Q=Quartz Restrike (Hot Strike Only)
EM=Quartz Restrike with ''Delay Relay'' (Quartz
lamp strikes at both hot and cold starts)
TPPH-F2=Thru-Way Pendant Power Hook Double Fused, 208, 240, or 480 Volt.
Requires FL-1 and PHC. Specify
Voltage.
Not available with HL or HC options.
EM/SC=Emergency Separate Circuit11
Lamp is shipped separately.
L/TCB=Less Top Connector Box (Housing
shipped less top connector box.
(Specify when using TWMBS
accessory)
TPPH-F-QD=Thru-Way Pendant Power Hook
Single Fuse, Quick Disconnect.
Requires FL-1 and PHC. Specify
Voltage (120, 277, or 347V)
LL=Lamp
Included12
SCR=Aircraft Safety Cable-Housing to
Reflector
W/MWS=MWS Industrial components attached
to the fixture at the factory. (Standard
cord length is 3 ft. 6 ft. and 11 ft. also
available. Please refer to MWS
Modular Wiring System section for
additional information.
TPPH-F2-QD=Thru-Way Pendant Power Hook
Double Fuse, Quick Disconnect.
Requires FL-1 and PHC. Specify
Voltage (208, 240, or 480V)
TPPH-NEMA=Thru-Way Pendant Power Hook.
Requires FL-1 and
PHC-XXXV-NEMA. (Specify
FH-1=Fixture Hook
FL-1=Fixture Loop
SHK=Hook with Safety Screw
TWMBS=Thru-Way Mounting Box15
HC=LumaWatt Fixture Control Module 10, 13
(Low voltage leads pulled out of top
connection box for areas requiring all
wiring to be installed in conduit)
10
HL=LumaWatt Fixture Control Module
(Allows low voltage control wire to be
daisy-chained between fixtures outside
AC conduit run similar to low voltage
intercom's, fire alarms and phone
systems)
LAMP TYPE
WATTAGE
Pulse Start Metal Halide (MP)
175, 200, 250, 320, 350, 400, 450W
Metal Halide (MH)
175, 250, 400W
High Pressure Sodium (HP)
250, 400W
QLL=Quartz Lamp Included (Lamp is Cooper
designated product based on luminaire
requirements. Lamp is shipped separate
from luminaire unless otherewise noted)
VOLTAGE CHART
MT=Multi-Tap
TT=Triple-Tap
5T=5-Tap
9
120/208/240/277 (wired 277V)
120/277/347 (wired 347V)
120/208/240/277/480 (wired 277V)
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
ADH082400
2015-12-02 09:12:02
SS 22" PRISMATIC
P H OTO M E T R I C S
90
3.8
7.7
60
Coefficients Of Utilization
Effective floor cavity reflectance
rc
80%
70%
rw 70 50 30 10
70 50 30 10
RCR
1 93 89 85 82
88 85 82 79
11.5
15.5
30
CP/1000
MPSS-PD22-C-400-120
400-Watt MP
42,000-Lumen Coated Lamp*
*Coated lamp recommended.
30%
50 30 10
10%
50 30 10
0%
0
78 75 73
71 69 68
65 64 62
59
2
86 79 74 70
82 76 71 67
70 66 63
64 61 59
59 57 55
52
3
79 71 65 60
76 69 63 59
63 59 55
59 55 52
54 51 49
46
4
74 65 58 53
70 62 56 51
58 53 49
54 49 46
50 46 44
41
5
69 59 52 47
65 57 50 46
53 47 43
49 45 41
46 42 39
37
6
64 54 47 42
61 52 45 41
48 43 39
45 41 37
42 38 36
34
7
60 49 42 38
57 48 41 37
45 39 35
42 37 34
39 35 32
30
8
56 45 39 34
53 44 38 33
41 36 32
39 34 31
36 32 30
28
9
52 42 35 31
50 40 34 30
38 33 29
36 31 28
34 30 27
25
10
49 39 32 28
47 38 32 28
35 30 27
33 29 26
32 28 25
23
Spacing Criterion
1.3
Zone
%Lamp
Zone
0-30
29.1
0-90
0-40
46.0
90-180
0-60
60.5
Total
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
20%
50%
50 30 10
Specifications and
dimensions subject to
change without notice.
%Lamp
69.6
19.1
88.7
Candlepower
Degree CP
0
15546
5
15546
15
15300
25
15534
35
12095
45
5975
55
1645
65
1192
75
1261
85
1380
90
1419
95
1467
105
1445
115
1312
125
1186
135
1296
145
1503
155
1428
165
1103
175
236
180
159