COOPER LIGHTING - SURE-LITES Catalog # Type ®

advertisement
COOPER LIGHTING - SURE-LITES ®
DESCRIPTION
The ideal unit for environments where an emergency lighting unit will be
exposed to water spray, penetrating steam, or dampness. The UMB
Series is best suited for use in areas like waste water treatment plants,
food processing facilities and most industrial applications.
Type
Catalog #
Project
Date
Comments
Prepared by
S P E C I F I C AT I O N F E AT U R E S
E l e c t ro n i c
H o u s i n g C o n s t ru c t i o n
Wa rra n t y
- Dual Voltage Input 120/277
VAC, 60 Hz
- Line-latching
- Solid-state Voltage Limited
Charger
- Solid-state Switching
- Low-Voltage Disconnect
- Brownout Circuit
- Overload/Short Circuit
Protection
- Test Switch/Power
Indicator Light
- UL listed NEMA
4X Fiberglass
- Watertight and Corrosion
Resistant
- Gasketed, Internally
Hinged Front Cover
- Corrosion Resistant
Grey Finish
- All units come standard
with a breather vent
- Unit: 1-year
- Battery: 15-year pro-rata
H e a d / L a m p Da t a
- Two Top Mounted
Heads Standard
- Glare-Free Lens
- Fully Adjustable
- PAR 36 Sealed Beam
- Remote Capability
- High Impact Thermoplastic
- Matches Housing Finish
Code Compliance
- UL 924 Listed
- Life Safety NFPA 101
- NEC/OSHA
- Wet Location Listed - For 32°F
or 0°C and above
- Most State and Local Codes
- NEC/OSHA
- Wet Location Listed or 32°F or 0°C and above
- Most State and Local Codes
B a tte r y
- Sealed Lead Calcium,
Recombination
- Maintenance-Free, Long-Life
- Full Recharge Time, 24 hrs.
(max.)
- Polarized Battery Terminals
UMB SERIES
W E T LO C AT I O N S
SEALED LEAD CALCIUM
B AT T E RY
E M E R G E N CY L I G H T I N G
12 1/4"
[311mm]
CHARGE
6 1/2"
[165mm]
TEST
ORDERING INFORMATION
10" [254mm]
6" [152mm]
E N E R G Y D ATA
Series
UMB1
UMB6
UMB7
UMB8
UMB9
Options 1
TDM=Time Delay Monitor
Accessories
TH=Thermal Heater for Battery
Compartment (For Use w/Lead
Calcium Exits)
WG7=Wire Guard
Notes:
2
Protective Housing
VS2WP=Polycarbonate Vandal Shield - Weatherproof
1 Alternate Lamps, Finishes and Options available. Consult your Cooper Lighting Representative. 2 Order separately.
Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.
UMB1, UMB6, UMB7
Input Current (Max.):
120V= .12A
277V= .05A
UMB8, UMB9
Input Current (Max.):
120V= .30A
277V= .13A
ADX041183 pc
2010-07-28 08:02:05
UMB SERIES - SEALED LEAD CALCIUM
E L E C T R I C A L R AT I N G
R a t e d W a t t a g e to 87 1/2% of Rated D.C. Voltage
Model
DC Voltage
1 1/2 Hours
UMB1
UMB6
UMB7
UMB8
UMB9
6
6
6
12
12
18
27
54
36
54
2 Hours
Lamp Information
3 Hours
15
24
48
30
48
4 Hours
8
14
28
16
28
10
18
36
20
36
Type
Wattage
Number
Incandescent
Incandescent
Incandescent
Halogen
Halogen
8
8
8
8
8
29-03
29-03
29-03
29-16
29-16
P H OTO M E T R I C S
H o r i z o n t a l D i s t r i b u t i on
Ve r t i c a l D i s t r i b u t i o n
10
FEET
LEFT
10
FEET
LEFT
LAMP
AXIS
0
1FC
0.5
0.3
0.2
0.1
LAMP
AXIS
0
1FC
0.5
0.3
0.2
0.1
FEET
RIGHT
10
FEET
RIGHT
10
0
10
20
30
40
50
60
70
0
10
20
30
40
50
70
60
FEET FROM LAMP (Measured on axis)
FEET FROM LAMP (Measured on axis)
Lamp No. 29-03 or 29-49
Initial Lumens – 29-03 @ 108
29-49 @ 111
Lamp No. 29-03 or 29-49
T E C H N I C A L DATA
Heads
S o l i d - S t a te C h a rge r
The lamp housing is constructed of flameresistant and impact-resistant injection molded
thermoplastic with matching grey finish. The
three dimensional swivel assembly permits 80°
aiming adjustment from vertical and
approximately 358° rotation. The placement is
secured with a lockable pivot mounted on a
rotating base ring. Heads and swivels are silicon
sealed to prevent moisture from entering
housing.
Supplied with a 120/277 VAC, voltage regulated
solid-state charger. Immediately upon
restoration of AC current after a power failure,
the charger provides a high charge rate. The
charge circuit reacts to the condition of the
battery and alters the rate of charge in order to
maintain peak battery capacity and maximize
battery life. Solid-state construction recharges
the battery following a power failure in
accordance with UL 924.
Lamps
O ve rl o a d a n d S h o rt C i rc u i t P ro te c t i o n
Designed specifically for emergency lighting
applications, the PAR 36 sealed beam lamps
insure optimum glare-free trapezoidal light
distribution along with horizontal and vertical
adjustment by rotating the lamp within the
housing.
The solid-state overload monitoring device in
the DC circuit disconnects the lamp load from
the battery should excessive wattage demands
be made and automatically resets when the
overload or short circuit is removed. This
overload current protective feature eliminates
the need for fuses or circuit breakers for the DC
load.
Housing
The rugged industrial grey fiberglass housing is
both watertight and corrosion-resistant.
Gasketed cover is internally hinged and housing
is equipped with a breather vent.
L i n e - L a t ch e d
Sure-Lites’ line-latched electronic circuitry
makes installation easy and economical. A labor
efficient AC-activated load switch prevents the
lamps from turning on during installation to a
non-energized AC circuit. Line-latching
eliminates the need for a contractor’s return to a
job site to connect the batteries when the
building’s main power is permanently turned
on.
detect a loss of AC voltage and automatically
energizes the lamps. Upon restoration of the AC
power, the emergency lamps will switch off and
the charger will automatically recharge the
battery.
L ow- Vo l t a ge D i s c o n n e c t
When the battery’s terminal voltage falls below
80% of the rated voltage, the low-voltage
circuitry disconnects the lighting load. The
disconnect remains in effect until normal utility
power is restored, preventing deep battery
discharge.
Te s t Sw i t ch / Powe r I n d i c a to r L i g h t
Conveniently located rubber booted Test Switch
allows for manual verification of proper
operation of the transfer circuit and emergency
lamps. A sealed light emitting diode (Power
Indicator Light) provides visual assurance that
the AC power is on.
B row n o u t C i rc u i t
S e a l e d L e a d C a l c i u m B a tte r y
The brownout circuit in Sure-Lites’ units
monitors the flow of AC current to the unit and
activates the emergency lighting system when a
predetermined reduction of AC power occurs.
This dip in voltage will cause most ballasted
fixtures to extinguish causing loss of normal
lighting even though a total power failure has
not occurred.
The fully sealed, long-life, maintenance-free
lead calcium battery is ideal for emergency
lighting applications. These recombinant cycle
batteries typically provide eight to ten years of
life and may be operated in any position.
S o l i d - S t a te Tra n s fe r
The unit incorporates a solid-state switching
transistor which eliminates corroded and pitted
contacts or mechanical failures associated with
relays. The switching circuit is designed to
Wa rra n t y
All Sure-Lites’ units are backed by a firm oneyear warranty against defect in material and
workmanship (excluding lamps). Maintenancefree, long-life, sealed lead calcium batteries
carry a five-year pro-rata warranty.
Specifications and dimensions subject to change without notice.
Sure-Lites • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADX041183 pc
2010-07-28 08:02:05
2010-07-28 14:07:30
Download