COOPER LIGHTING - SURE-LITES DESCRIPTION Catalog # Versatile “mini-system” features electronic reliability, quality metal construction, surprising economy, optimum illumination and attractive compact appearance. Type Project The popular choice for commercial, institutional and public facilities where moderate loads, economy, ease of installation, safety and reliability are important. Maximum emergency lighting efficiency is combined with low profile appearance. Comments Prepared by Date A P P L I C AT I O N The unit of choice for installations where the size and cost of emergency lighting must be kept to a minimum without sacrificing dependability or light output. S P E C I F I C AT I O N F E AT U R E S Electronic Knockout, Conduit or Cord Set Code Compliance Dual Voltage Input 120/277 VAC, 60 Hz Universal J-Box Mounting Pattern UL 924 Listed Line-latching Keyhole Mounting Slots NEC/OSHA Solid-state Voltage Limited Charger White Finish Most State and Local Codes Solid-state Switching Battery Warranty Low Voltage Disconnect Sealed Lead Calcium, Recombination (LM1, AA1) Unit – 1 year Brownout Circuit Life Safety NFPA 101 Head/Lamp Data Maintenance Free, Long Life Test Switch/Power Indicator Light Two Heads Standard Full Recharge Time, 24 hrs. (max.) Glare-Free Lens Fully Adjustable Polarized Battery Terminals Housing Construction AA SERIES Battery – 5 year pro-rata Sealed Nickel Cadmium Battery (AA8) Overload/Short Circuit Protection DOUBLE HEAD High Impact – Thermoplastic 22 Gauge Die-Formed Steel Matches Housing Finish M E TA L B O D Y EMERGENCY LIGHT Emergency Lighting 9 1/8" [232mm] 4 1/2" [114mm] 2 1/4" [57mm] 4 1/4" [108mm] 2 1/4" [57mm] 5" max. [127mm] 4" [102mm] 6 1/8" [156mm] 12 1/4" [311mm] E L E C T R I C A L R AT I N G S R a t e d W a t t a g e to 87 1/2% of Rated D.C. Voltage Model AA1 Battery DC Voltage SLC3 6 1 1/2 Hours 18 2 Hours 15 Lamp Information 3 Hours 10 4 Hours 8 Type Wattage Number Incandescent 9 29-84 E N E R G Y D AT A O R D E R I N G I N F O R M AT I O N Input Current (Max.): 120V= .12A 277V= .05A SAMPLE NUMBER: AA1V AA1 Model AA1 O p t i o n s (add as suffix) A=Ammeter 2 SD=Self-Diagnostics TDM=Time Delay Monitor V=Voltmeter 2 Alternate Lamps 1 Other Finishes 1 Other Options 1 COOPER LIGHTING A c c e s s o r i e s (order separately) 1BRWH =Mounting Brackets NOTES: (2) White (1) Consult your Cooper Lighting 1MSWH=Mounting Shelf, White VK1=Voltmeter Representative. WG1 =Wire Guard (2) Provision for one meter only. CSK120=Cord Set (120VAC) (3) SLC=Sealed Lead Calcium CSK277=Cord Set (277VAC) VS1=Polycarbonate Vandal Shield VS1WP=Polycarbonate Vandal Shield - Weatherproof ADX040995 ® A A SERIES PHOTOMETRICS Horizontal Distribution Ve r t i c a l D i s t r i b u t i o n 10 FEET LEFT 10 FEET LEFT 1FC 0 0.5 0.3 0.2 0.1 LAMP AXIS 1FC 0 FEET RIGHT 10 0.5 0.3 0.2 0.1 LAMP AXIS FEET RIGHT 10 0 10 20 30 40 50 60 70 0 FEET FROM LAMP (Measured on axis) Lamp No. 29-84 Initial Lumens – 29-84 @ 132 10 20 30 40 50 60 70 FEET FROM LAMP (Measured on axis) Lamp No. 29-84 T E C H N I C A L D AT A Heads Line-Latched The lamp housing is constructed of flame-resistant and impactresistant polycarbonate injection molded thermoplastic with matching finish. The three dimensional swivel assembly permits approximate aiming adjustment from 80° vertical and 358° rotation. The placement is secured with a lockable pivot mounted on a rotating base ring. Sure-Lites’ line-latched electronic circuitry makes installation easy and economical. A labor efficient AC-activated load switch prevents the lamps from turning on during installation to a non-energized AC circuit. Line-latching eliminates the need for a contractor’s return to a job site to connect the batteries when the building’s main power is permanently turned on. Lamps Designed specifically for emergency lighting applications, the PAR 36 sealed beam type design insures optimum glarefree trapezoidal light distribution along with horizontal and vertical adjustment by rotating the lens within the housing. Housing The rugged 22 gauge dieformed steel housing is finished with white corrosion-resistant polyester powder coat paint. Cabinet has keyhole mounting slots and knockouts in rear and side for AC/DC wiring connections and has universal mounting pattern. Overload and Short Circuit Protection The solid-state overload monitoring device in the DC circuit disconnects the lamp load from the battery should excessive wattage demands be made and automatically resets when the overload or short circuit is removed. This overload current protective feature eliminates the need for fuses or circuit breakers for the DC load. Brownout Circuit Solid-State Charger Supplied with a 120/277 VAC, voltage regulated solid-state charger. Immediately upon restoration of AC current after a power failure, the charger provides a high charge rate. The charge circuit reacts to the condition of the battery and alters the rate of charge in order to maintain peak battery capacity and maximize battery life. Solid-state construction recharges the battery following a power failure in accordance with UL 924. The brownout circuit in SureLites’ units monitors the flow of AC current to the unit and activates the emergency lighting system when a predetermined reduction of AC power occurs. This dip in voltage will cause most ballasted fixtures to extinguish causing loss of normal lighting even though a total power failure has not occurred. S o l i d - S t a t e Tr a n s f e r The unit incorporates a solidstate switching transistor which eliminates corroded and pitted contacts or mechanical failures associated with relays. The switching circuit is designed to detect a loss of AC voltage and automatically energizes the lamps. Upon restoration of the AC power, the emergency lamps will switch off and the charger will automatically recharge the battery. L o w Vo l t a g e D i s c o n n e c t When the battery’s terminal voltage falls below 80% of the rated voltage, the low voltage circuitry disconnects the lighting load. The disconnect remains in effect until normal utility power is restored, preventing deep battery discharge. Te s t S w i t c h / P o w e r I n d i c a t o r Light Conveniently located combination Test Switch/Power Indicator Light allows for manual verification of proper operation of the transfer circuit and emergency lamps. Sealed Lead Calcium Battery The fully sealed, long life, maintenance free lead calcium battery is ideal for emergency lighting applications. These recombinant cycle batteries typically provide eight to ten years of life and may be operated in any position. Warranty All Sure-Lites’ units are backed by a firm one year warranty against defect in material and workmanship (excluding lamps). Maintenance free, long life, sealed lead calcium batteries carry a five-year pro-rata warranty. N O T E S : See option/accessories or technical sections for additional detailed product data. Specifications and Dimensions subject to change without notice. Customer First Center 1121 Highway 74 South, Peachtree City, GA 30269 770.486.4800 Fax 770.486.4801 ADX040995