Instruction Leaflet IL032009EN Effective December 2015 Version 2.0 105U-G wireless gateway installation guide Figure 1. Antenna Installation Antenna* 1 Wavelength (minimum) Wavelengths: 360 MHz = 32.7" (83 cm) 512 MHz = 22.8" (58 cm) 869 MHz = 13.4" (34 cm) Stress Relief Loop Weatherproof Connections (recommended: 3M™ 23 selfbonding tape) CAUTION For continued protection against risk of fire, replace the module fuse only with the same type and rating. Coaxial Cable 105U-G Mast ELPRO Wireless Gateway 105U-G Ethernet Statutory requirements Antenna installation Use Figure 1 as a guide for installing an antenna and attaching it to the module. Serial RX Radio TX GND GND SUP2 SUP1 DIO 7 DIO 8 OK Earth Conductor at least 5 AWG (16 mm2) BAT+ GND DIO 5 DIO 6 DIO 3 DIO 4 DIO 1 ACT DIO 2 EC: Unlicensed operation limits the radio power. High gain aerials may only be used to compensate for cable losses. RX TX Surge Arrestor (optional) * For maximum range, install above local obstructions. GND at least 11 AWG (4 mm2) Earth Stake Provide good ground connection to mast, module, and surge arrestor. If ground conditions are poor, use more than one stake. Instruction Leaflet IL032009EN 105U-G wireless gateway installation guide EATON_105U-G Install Guide Effective December 2015 Version 2.0 Installation Figure 2. Wiring Diagram Choose a power supply option: • 12–24 Vac, 1.5A CSA certified Class 2 • 15–30 Vdc, 1.5A CSA certified Class 2 • 11–15 Vdc, 1.5A • Solar panel with battery Host Protocol Connection After choosing a power supply option, wire the module as shown in Figure 2. ELPRO Wireless Gateway NNote: All I/O must be SELV. DIO channels can be wired as inputs or outputs. 105U-G-ET1 Ethernet When the wiring is completed, connect the module to a computer (PC) and configure it using the configuration software. For details, refer to the user manual. RX Serial TX Before operating the module, read the sections on operation and configuration in the user manual to take advantage of all product features. RX Radio TX WARNING EXPLOSION HAZARD ACT OK BAT+ GND SUP2 SUP1 GND DIO 8 DIO 7 DIO 6 DIO 5 DIO 4 DIO 3 DIO 2 DIO 1 GND SUP1 SUP2 SUP1 GND Do not disconnect while circuit is live unless area is known to be non-hazardous. 2A – + DC Supply 9–30 Vdc, 16 Vac To Earth Connection Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton’s wireless business www.eaton.com/wireless – + – + AC Supply 12–24 Vac Do not earth SUP1 or SUP2 connection. 12V Backup Battery (optional; up to 100 Ah) Digital Input Voltage-Free Contact or Transistor Device To Earth Connection + – Digital Output Max. 30 Vdc, 500 mA DC Relay Supply © 2014 Eaton All Rights Reserved Printed in USA Publication No. IL032009EN December 2015 Eaton is a registered trademark. All other trademarks are property of their respective owners.