Room Controller - Conference Room w/Daylight Dimming and BMS Output Summary Proper lighting that emphasizes daylighting with natural light provides a more focused meeting environment. This application illustrates how conference rooms can use basic dimming in conjunction with natural light entering the space, while providing Scene Control/Automatic Off to achieve energy savings up to 60% and achieve higher quality lighting. Providing optional control of individual lighting zones and HVAC output will allow for even greater energy savings. The Room Controller QuicKit is shipped preconfigured to work out-of-the-box minimizing installation and setup time, while ensuring maximum energy savings. Using this design guide to specify your room with a Room Controller QuicKit catalog number will guarantee that after installation the lighting control system will work immediately as defined on this application guide. Room Controller Sample room layout (10ʹ x 10ʹ) Half Lights Full Lights Room Controller QuicKit Raise Lower Half Lights All Off Full Lights Half Lights Raise Full Lights Lower Raise All Off Lower All Off RCQK-OS3E-CR2-ZAD-W1-D1-B-W RC3DE Half Lights Full Lights OCC-RJ45 (BMS output/Egress Control) RC3DE (3 Relay + 3 Dimmer + Normal Power 1 Emergency) Raise Half Lights Lower Full Lights All Off Product Legend Qty1: RC3DE 3 On/off relays + 3 dimmers + 1 Emergency Relay Raise General Zone 1 UP Meeting Zone 1 DN Whiteboard Zone 2 UP Presentation Zone 2 DN All Off Zone 3 UP Zone 3 DN Connection OCC-RJ45 (Connection to any Greengate sensor) Lower RC3DE RC3DE All Off General Meeting Whiteboard Presentation RC-6TSB-ZAD-* (Pre-engraved Wallstation) RC3DE All Off OAWC-DT-120W (Wall Corner Occupancy Sensor) Half Lights Half Lights Full Lights Full Lights Raise Raise Lower Lower All Off All Off RC3DE RC3DE Half lights Full lights RC-6TSB-CR2-* (Pre-engraved Wallstation) Half Lights Full Lights All Off Raise Lower All Off RC3DE RC3DE Half Lights Full Lights Raise Lower All Off Load 3 RC3DE Dimmer 3 RC3DE Qty1: RC-5TsB-CR2-W General, Meeting, whiteboard, presentation, all off) Qty:1 RC-6tsb-zad-W Zone 1 UP, Zone 1 DN, Zone 2 UP, Zone 2 DN, Zone 3 UP, Zone 3 DN Qty1: DSRC-FMOIR Daylight Sensor Qty1: OAWC-DT-120W Wall Corner mount vacancy sensor Qty1: OCC-RJ45 Occupancy sensor RJ45 connector Load 2 Qty1: OCC-RJ45 BMS or egress connector Dimmer 2 Qty1: GGRJ45-03-G Quickconnect cable 3’ Entry Lighting All Off Qty2: GGRJ45-10-G Quickconnect cable 10’ Load 1 Dimmer 1 Qty2: GGRJ45-25-G Quickconnect cable 25’ DSRC-FMOIR (Multi-zone Daylight Sensor) RC3D Single box packaging with wiring detail and installation Entry Lighting Entry Lighting All Off All Off Recessed Fixture General Entry Exam Lighting Reading All Off For guaranteed compatibility refer to preferred Cooper lighting fixture information below. All Off Entry Lighting All Off TV CHANNEL VOLUME cc 1 2 4 3 5 7 6 8 9 0 PREV SLEEP MUTE OPTION 2 Entry Entry Lighting Lighting 1 3 ALL ON/OFF All Off All Off Control sequence RC3D RC3D • Scene Control/Automatic Off 1. All On, Dimmers set to: 100%, 80%, 100% Entry Lighting All Off 1. Press and hold raise lighting 5% General Whiteboard • Individual Zone Raise/Lower control Quiet Time • A/V Mode Raise RC3D Lower General 2. All On, DimmersRC3D set to: 80%, 20%, 100% Entry Lighting Zone 1 UP All Off • Occupancy based HVAC or Egress control Meeting Whiteboard • Automatic multi-zone daylight dimming out-of-the-box Presentation Zone 1 DN Zone 2 UP 3. All On, Dimmers set to: RC3D RC3D 50%, 100%, 25% Zone 2 DN General Exam General Reading 2. Press and hold lowers lighting 5% 3. Press and hold raise lighting 5% 4. Press and hold lowers lighting 5% Exam All Off • Automatic Demand Response 10%-40% reduction based on input All Off Zone 3 UP Reading All Off 4. All On, Dimmers set to: 30%, 0%, 25% • High-end trim/tuning to define target light levels UL924 5. All Off UL924 warn Offs and timers to ensure maximum efficiency and • After-hours UL924 RC-5TSB-CR2-W savings Conference Room Wallstation 5. Press and hold raise lighting 5% 6. Press and hold lowers lighting 5% RC3D General Exam TV CHANNEL VOLUME Reading cc All 1 Off2 CHANNEL TV 3 General VOLUME 4 cc 5 6 7 Exam 8 9 1 2 3 Reading 0 4 5 6 PREV MUTE SLEEP OPTION 7 All 28Off 9 1 3 0 PREV MUTE ALL ON/OFF SLEEP OPTION 2 1 3 ALL ON/OFF RC3D General TV General Exam cc Exam 1 Reading 2 3 Reading 6 All4Off 5 7 All8Off 9 CHANNEL VOLUME TV CHANNEL 1 RC-6TSB-ZAD-W Individual Dimming Wallstation VOLUME 0 cc PREV SLEEP MUTE OPTION 12 2 3 5 4 ALL ON/OFF 7 3 6 8 9 0 PREV SLEEP Integrated capabilities Zone 3 DN MUTE OPTION 2 Cooper Lighting Guaranteed Compatible Fixtures 1 3 ALL ON/OFF General General Whiteboard Exam General Quiet Time • Reading TV Whiteboard All Off A/V Mode CHANNEL TV VOLUME cc CHANNEL VOLUME Quiet Time Raise cc • 1 2 3 Metalux LED A/V Mode 1 2 Lower 4 5 4 7Raise8 7 Lower 0 PREV SLEEP 1 3 6 5 9 8 6 9 MUTE 0 PREV MUTE OPTION 2 SLEEP 3 2 1 OPTION 3 ALL ON/OFF ALL ON/OFF Room Controller Office Lighting Layouts General Exam Metalux LFL Reading UL924 All Off General Room Controller Office Lighting Layouts Whiteboard TV CHANNEL VOLUME Quiet Time • cc A/V Mode 1 2 3 General Raise4 5 6 Whiteboard 7 8 9 Lower Quiet Time • 0 Corelite LED PREV MUTE SLEEP A/V Mode 2 1 Raise OPTION 3 ALL ON/OFF Room Controller OfficeLighting Layouts Lower Corelite LFL CHANNEL TV VOLUME cc 1 2 5 6 8 9 0 PREV SLEEP Occupancy/Vacancy Sensing Daylighting Control Manual Control Integration 3 4 7 ALL ON/OFF Refer to these Cooper Lighting data sheets for lighting layouts and illuminance value information. General Whiteboard Quiet Time • A/V Mode Raise www.coopercontrol.com Lower General Whiteboard Quiet Time • A/V Mode 1 Room Controller Office Lighting Layouts MUTE OPTION 2 General1 3 General Whiteboard Whiteboard Quiet Time • Quiet Time • A/V Mode A/V Mode Raise Raise Lower Lower Demand Response Raise Lower Room Controller - Conference Room w/Daylight Dimming and BMS Output Room Controller and Smart Devices use Click & Go technology The RC3D will automtically recognize any smart device connected with the QuickConnect cable (provided) and start working immediately upon power up with no programming required. The RC3D defaults to Manual On/Automatic Off vacancy sensor mode for maximum energy savings. Office stations provide On/Off control of the Yellow, Red and Purple loads as well as manual Raise/Lower of all dimmers. The daylight sensor will automatically provide multi-zone daylight dimming in the space. (Remote adjustments can be made later.) *Refer to Room Controller website for more information on other integral no programming required benefits like Demand Response, Solatube Control, Egress Control, BMS Output, Alert Mode, Emergency Lighting Control, and Slider Stations. WHT/ORG or WHT/BLK Neutral BLACK - Hot (120/277 VAC) YELLOW Lighting Load (1) RED Lighting Load (2) PURPLE Lighting Load (3) BLUE - Relay In (120/277 VAC) Requires 0-10V dimming ballasts Violet - Dimmer 1 Gray - Dimmer 1 Violet - Dimmer 2 Gray - Dimmer 2 Violet - Dimmer 3 Gray - Dimmer 3 0-10V Dimming Zone Note: The 0-10V dimming zones within the Room Controller can be wired and controlled independent of the connected loads. This allows a each load to have a dedicated 0-10V dimming zone or a single load to have up to three 0-10V dimming zones. QuickConnect coupler (GGRC-COUPLER) BMS/ Egress Output: Occupancy status output to the Building Management System or other 3rd party system require no programming of the Room Controller and occurs when ever there is occupancy in the room regardless of light output status. (OCC-RJ45) Adjustable daylight sensor dome Quick connect cables are pre-terminated and included in the Room Controller QuicKit and measured to fit typical room layouts Daylight sensor (DSRC-FMOIR) *Immediately provides multi-zone daylight dimming upon powerup Allows connection to any Greengate Occupancy/Vacancy Sensor (OCC-RJ45) Button 1: Load (1), (2), (3) ON, Dimmer 1: 100%, Zone 1 UP General Dimmer 2: 80%, Dimmer 3: 100% Button 1: Press and hold increase Zone 1 lighting 5% Meeting Zone 1 DN Button 2: Press and hold decrease Zone 1 lighting 5% Button 2: Load (1), (2), (3) ON, Dimmer 1: 80%, Whiteboard Zone 2 UP Button 3: Press and hold increase Zone 2 lighting 5% Dimmer 2: 20%, Dimmer 3: 100% Presentation Zone 2 DN Button 4: Press and hold decrease Zone 2 lighting 5% Button 3: Load (1), (2), (3) ON, Dimmer 1: 50%, Zone 3 UP All Off Button 5: Press and hold increase Zone 3 lighting 5% Dimmer 2: 100%, Dimmer 3: 25% Zone 3 DN Button 6: Press and hold decrease Zone 3 lighting 5% Button 4: Load (1), (2), (3) ON, Dimmer 1: 30%, Dimmer 2: 0%, Dimmer 3: 25% Button 5: Load (1), (2), (3) OFF RC-5TSB-CR2-*RC-6TSB-ZAD-* Office Station Office Station Dual Technology Wall Corner Occupancy/Vacancy Sensor (OAWC-DT-120W) *Defaults to vacancy sensor mode Manual On/Automatic Off (all loads) for maximum energy savings Cooper Controls 203 Cooper Circle Peachtree City, GA 30269. USA Tel: +1-800-553-3879 Fax: +1-800-954-7016 Email: controls@cooperindustries.com Website: www.coopercontrol.com Room Controller - RC3D Three Relay + Three Dimmers Wiring Diagram Drawing Name: RC3D-Conference-BMS.dwg www.coopercontrol.com 2 Drawing Date: 1/10/2013 Room Controller - Conference Room w/Daylight Dimming and BMS Output Mounting The Room Controller The Room Controller mounts above the ceiling in the space it is controlling, typically above the door to the room. The Room Controller includes breakouts for direct conduit connection limiting the need for additional junction boxes. Mount the Room Controller using the keyhole slots at the top and secure to the wall using the holes at the bottom of the Room Controller. Connect conduit to the line voltage breakout connections and connect the line and load wires. Connect low voltage cables either through the low voltage breakout openings or by connecting low voltage conduit to the breakouts on the low voltage side of the Room Controller. Sample Placement Diagram Daylight Sensor Ceiling Location (for example purposes only) 1. Mount the daylight sensor one to two times the window height from the window wall. 2. Position the sensor so its arrow is pointed toward the nearest window. 3. Ensure the daylight sensor is not obstructed or looking directly at electric light. 4. For narrow spaces mount the daylight sensor near the window facing into the space. Sample Placement Diagram (for example purposes only) Room Controller (above entry door) Wall/Corner Mount Occupancy Sensor Additional Wallstation General On AV Mode Whiteboard Quiet Time Raise Lower Entry Wallstation General On Off Window Daylight Sensor 60° Area viewed by daylight sensor Occupancy sensor Coverage Diagram (OAWC-DT-120W) 24’ (7.3 mm) Wiring Diagram 20’ (6 mm) OCC-RJ45 Room Controller Normal Power (BMS/ Egress Output) (Above Entry Door) (Line In & Load Out) 24’ (7.3 mm) 20’ (6 mm) 12’ (3.7 mm) RC3D Minor Motion, IR 8’ (2.4 mm) 0 8’ (2.4 mm) (low voltage, class 2) Major Motion, IR Minor Motion, Ultrasonic 12’ (3.7 mm) 12’ (3.7 mm) 8’ (2.4 mm) 0 8’ (2.4 mm) OCC-RJ45 Major Motion, Ultrasonic Minor Motion, IR Major Motion, IR Maximum coverage area may Minor Ultrasonic varyMotion, somewhat according to room shapeMotion, and theUltrasonic presence of obstacles. Major 12’ (3.7 mm) 0-10V Dimmer Wiring (Dimming Models Only) The NEMA WD 7 Guide and robotic method coverage were utilized verify Maximum areatomay coverage patterns. vary somewhat according to room shape and the presence of obstacles. 24’ (7.3 mm) (Any Greengate Occupancy Sensor) 20’ (6 mm) 10 ft (3 mm) Wallstation 10 ft (3 mm) (Entry) 24’ (7.3 mm) 24 ft 6 ft 15 ft 20’ (6 mm) (1.7 mm) (4.6 mm) (7.3 mm) 50 ft (15.3 mm) The NEMA WD 7 Guide and robotic method were utilized to verify coverage patterns. Half Lights 24 ft 6 ft 15 ft (1.7 mm) (4.6 mm) (7.3 mm) Full Lights Raise Lower 50 ft (15.3 mm) All Off Connections Room Controller and Smart Devices use Click & Go Connections Room Controller 0-10V Dimming Connections Dimmer 1: Near the Window Dimmer 2: Middle of Room Dimmer 3: Far from Window - Dimmer 3 + - Dimmer 2 + - Dimmer 1 + The daylight sensor will automatically provide multi-zone daylight dimming based on this wiring configuration 0-10V Dimming 1 0-10V Gray (-) 0-10V Violet (+) www.coopercontrol.com 3 2 5 34 6 1. Wallstations (up to four) 2. Slider Station Connection (one) 3. Occupancy Sensors (up to two) 4. Daylight Sensor (one) 5. Receptacle Control or BMS Output 6. Switchpack (controlled with Load 1 for alternate voltage) Room Controller - Conference Room w/Daylight Dimming and BMS Output Ordering RCQK - OS3E - CR2 - ZAD - W1 - D1 - B - W Room Controller Daylight Station Color QuicKit D1 - Multi-zone Daylight Sensor DH - Multi-zone Daylight Sensor w/ Handheld Remote W - White G - Gray V - Ivory B - Black Office Stations (Choose up to 4) Types of Space and Control OS - Office Switching (RC3) OS2 - Office 2 Zone Dimming (RC3D2) OS3 - Office 3 Zone Dimming (RC3D) OS3E - Office 3 Zone Dimming and and Emergency Relay (RC3DE) OS1 - Half Lights, Full Lights, All Off (3 Large Buttons) OS2 - Half Lights, Full Lights, Raise, Lower, All Off † (5 Small Buttons) OS3 - Half Lights, Full Lights, Under Cabinet, Raise, Lower, All Off † (6 Small Buttons) OS4 - All On, All Off (2 Large Buttons) CR1 - General, Meeting, Whiteboard, Presentation, Raise, Lower (6 Small Buttons - Scenes) CR2 - General, Meeting, Whiteboard, Presentation, All Off (5 Small Buttons - Scenes) SS1 - Slider Station †† ZAD - Zone 1 UP, Zone 2 DN, Zone 3 UP, Zone 3 DN (6 Small Buttons - Scenes) Occupancy Sensor C1 - Ceiling DT 2000 sq. ft. C2 - Ceiling PIR 1500 sq. ft. C3 - Ceiling DT 1000 sq. ft. W1 - Wall Corner DT W2 - Wall Corner PIR W3 - Hallway PIR Options P - Plug Load B - BMS/Egress *Catalog number automatically includes low voltage connection cable, wallplates and connectors based on room type and configuration. Pre-defined Wallstation Model numbers Half lights Half Lights Half Lights Full Lights Full Lights Raise Undercabinet Lower Raise All Off Lower All Off Lower All On Full lights All Off RC-3TLB-OS1 RC-5TSB-OS2 All Off RC-6tsb-OS3 RC-2tlb-OS4 General General Meeting Meeting Zone 1 DN Whiteboard Whiteboard Zone 2 UP Presentation Presentation Zone 2 DN Raise All Off Zone 3 UP Zone 1 UP Zone 3 DN RC-6tsb-cr1 RC-5tsb-cr2 RC-6tsb-ZAD *For site specific engraving, please see the Room Controller Wallstation custom engraving form on the Cooper Controls website Applications Conference Room Application Button Functionality Program No. Button Text Control Type Function (Unless a target level is indicated, the dimmer output will default to daylight sensor control) 12 General Preset Load 1 (yellow) ON, Load 2 (red) ON, Load 3 (purple) ON Dimmer 1: 100%, Dimmer 2 80%, Dimmer 3 80% Solatube Open (RC3DE only) 13 Meeting Preset Load 1 (yellow) ON, Load 2 (red) ON, Load 3 (purple) ON Dimmer 1: 80%, Dimmer 2 20%, Dimmer 3 100% Solatube Open (RC3DE only) 14 Whiteboard Preset Load 1 (yellow) ON, Load 2 (red) ON, Load 3 (purple) ON Dimmer 1: 50%, Dimmer 2: 100%, Dimmer 3: 50% Solatube Closed (RC3DE only) 15 Presentation Preset Load 1 (yellow) ON, Load 2 (red) ON, Load 3 (purple) ON Dimmer 1: 30%, Dimmer 2: 0%, Dimmer 3: 25% Solatube Closed (RC3DE only) 6 Raise Raise Raise All Dimmers 7 Lower Lower Lower All Dimmers 16 All On Preset Load 1 (yellow) ON, Load 2 (red) ON Load 3 (purple) ON All Dimmers 100% 8 All Off Preset Load 1 (yellow) OFF, Load 2 (red) OFF, Load 3 (purple) OFF Solatube closed (RC3DE only) Slider Raise and Lower All Dimmers Slider † † †† Catalog # Type Project † These dimming wallstations can only be used with dimming Room Controllers (RC3D, RC3D2, RC3DE) †† Slider stations can not be used if a wallstation with Raise/Lower buttons are used Comments Prepared by www.coopercontrol.com 4 ACC130077 Date