Commercial Meter Pedestals

advertisement
Commercial
Meter Pedestals
Commercial Meter Pedestals
Commercial Metering Pedestals - Features & Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Commercial Metering Pedestals - Mounting Base Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
Commercial Metering Pedestals - Pad Mounted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Commercial Metering Pedestals - Post/Wall Mounted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
Commercial Metering Pedestals - Pad Mounted, Unmetered . . . . . . . . . . . . . . . . . . . . . . . . . 113
Commercial Metering Pedestals - Pad Mounted, Dual Distribution . . . . . . . . . . . . . . . . . . 114
Commercial Metering Pedestals - Specials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 - 116
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
Meter Mounting Equipment
108
Commercial Meter Pedestals - Features & Applications
Post, Wall, or Pad Mounted Pedestals with Isloated Components for Utility Metering
Name
Company Name
Address
Phone
Email
Typical Application
•
•
•
•
•
•
Street & highway lighting
Traffic signal controller metering
Irrigation control systems
Park & recreation facilities
Golf course lighting
Sign lighting
Commercial
Meter Pedestals
Construction
• NEMA Type 3R
• UL Listed
• ANSI 12.7
• EUSERC #308 Compliant (CMP4xxx MC1)
Service conductor terminations and customer’s equipment can be factory customized to meet
specific job requirements
Commercial Metering Pedestal - Customization Form
Enclosure Mounting Type
Supply Voltage
Service
Supply Amperage
Short Circuit Rating
Meter Bypass: Safety Socket (Test Block)
Disconnect: Main Circuit Breaker
q
q
Class “T” Fused Pullout
Distribution: Circuit Panelboard
Finish: Light Gray (ANSI 61)
Light Gray (ANSI 49)
q
q
Manual Circuit Closing
None
Light Green
White
q
q
q
q
Federal Brown
q
No Bypass
q
q
Other
q Switch: HOA (Hand-Off-Auto)
Test Switch
q Photo-E;ectric Cell: In Window
Field Installed
q Time Clock: 24 Hour
7 Day
Electronic
Mechanical
q Lighting Contractor: Amps
Poles
Control Voltage
q Thermostat: Electronic
Mechanical
q Cabinet Heater: Watts
q Control Transformer: Amps
q Duplex Receptacles:
q Terminal Block
Controls:
For online form, see www.cooperbline/metering.
Send completed form to customer service at Eaton’s B-Line Business. See address information on back cover.
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
109
Meter Mounting Equipment
Installation Instructions
Installation Instructions
CMP-4000 Series
CMP-4900 Series
Meter pedestals are designed for pad-mount
installation. Two methods can be used to install
pedestals on a concrete pad.
Meter pedestals are designed for pad-mount
installation. Two methods can be used to install
pedestals on a concrete pad.
1. Use pre-fabricated mounting base assembly.
A. Cat. No. MB1515 Suitable for 15” wide x 15” deep pedestals.
B. Cat. No. MB2015 Suitable for 20” wide x 15” deep pedestals.
1. Use pre-fabricated mounting base assembly.
A. Cat. No. MB2820 Suitable for 28” wide x 20” deep
pedestals. (CMP-4900 Models)
Install mounting base assembly flush with top
surface of concrete pad, allowing mounting studs
to reach above pad. Locate line and load conduits
in the designated areas as shown on drawing
below.
Install mounting base assembly flush with top
surface of concrete pad, allowing mounting studs
to reach above pad. Locate line and load conduits
in the designated areas as shown on drawings
below.
MB2820
MB2015
261/4”
1
181/4”
Line Side
Line Side
Line Side
6” x 141/2”
Load Side
Load Side
(Main Section)
Breaker
Load Side
121/4”
121/4”
16 /4”
131/4”
2. Use anchor bolts (3/8” dia.) pre-cast in concrete
pad. Mounting hole dimensions are shown
above for 15 x 15 and 20 x 15 pedestals.
Locate line and load conduits the same as in
method 1.
10”
Load Side
Distribution &
Control Section
MB1515
2. Use anchor bolts (3/8” dia.) pre-cast in concrete
pad. Mounting hole dimensions are shown
above. Locate line and load conduits the same
as in method 1.
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
Meter Mounting Equipment
181/4”
110
Commercial
Meter Pedestals
Commercial Meter Pedestals - Mounting Base Details
Commercial Meter Pedestals - Pad Mounted
Application
• Utility meter, main disconnect and distribution panel
• Receive ANSI C12.10 watthour meters
Construction
• Ring type
• NEMA Type 3R
• ANSI 61 gray E-coat finish
• Separate sealable utility termination and meter compartments
• Padlockable disconnect and distribution section
• Underground feed
Standards
• UL Listed
• ANSI C12.7
• EUSERC #308
Accessories
• 5th jaw kit - 50365 (single phase)
• Filler plate kit - 25139
• Class T fusible pullouts
• Controls, see page 109
CMP4111MC-1
Commercial
Meter Pedestals
Catalog
Number
CMP4111MC-1
CMP4111MCH-1
CMP4121MC-1
CMP4121MCH-1
CMP4411MC-1
CMP4411MCH-1
CMP4421MC-1
CMP4421MCH-1
Amp
Rating
100
100
200
200
100
100
200
200
Jaws
4
4
4
4
7
7
7
7
Service
Type
1Ø,3W
1Ø,3W
1Ø,3W
1Ø,3W
3Ø,4W
3Ø,4W
3Ø,4W
3Ø,4W
Bypass
Voltage
TB
TB
TB
TB
TB
TB
TB
TB
240
480
240
480
240
480
240
480
Distribution
Main Breaker
Branches
100A,2P
100A,2P
200A,2P
200A,2P
100A,3P
100A,3P
200A,3P
200A,3P
12
14
12
18
12
12
12
18
Type
Plug-In
Bolt-On
Plug-In
Bolt-On
Plug-In
Bolt-On
Plug-In
Bolt-On
Mounting
Pad
MB1515
MB2015
MB1515
MB2015
MB1515
MB2015
MB1515
MB2015
Width
Dimensions
Depth
15”
20”
15”
20”
15”
20”
15”
20”
1
17 /2”
171/2”
171/2”
171/2”
171/2”
171/2”
171/2”
171/2”
Height
54”
54”
54”
54”
54”
54”
54”
54”
Utility Meter & Test
Block Section
Customer
Distribution Section
(Padlock Provision)
Utility
Termination Section
(Padlock & Sealing
Provisions)
Front
Side
Back
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
111
Meter Mounting Equipment
Commercial Meter Pedestals - Post/Wall Mounted
Application
• Utility meter, main disconnect and distribution panel
• Receive ANSI C12.10 watthour meters
Construction
• Ring type
• NEMA Type 3R
• ANSI 61 gray E-coat finish
• Separate sealable utility termination and meter compartments
• Padlockable disconnect and distribution section
• Underground feed
Standards
• UL Listed
• ANSI C12.7
Catalog
Number
CMP4111M
CMP4111MC
CMP4111MCH
CMP4121M
CMP4121MC
CMP4121MCH
CMP4411M
CMP4411MC
CMP4411MCH
CMP4421M
CMP4421MC
CMP4421MCH
Amp
Rating
Jaws
Service
Type
Bypass
Voltage
100
100
100
200
200
200
100
100
100
200
200
200
4
4
4
4
4
4
7
7
7
7
7
7
1Ø,3W
1Ø,3W
1Ø,3W
1Ø,3W
1Ø,3W
1Ø,3W
3Ø,4W
3Ø,4W
3Ø,4W
3Ø,4W
3Ø,4W
3Ø,4W
-TB
TB
-TB
TB
-TB
TB
-TB
--
240
240
480
240
240
480
240
240
480
240
240
480
Distribution
Main Breaker Branches
100A,2P
100A,2P
100A,2P
200A,2P
200A,2P
200A,2P
100A,3P
100A,3P
100A,3P
200A,3P
200A,3P
200A,3P
12
12
14
12
12
18
12
12
12
12
12
18
Type
Width
Dimensions
Depth
Height
Plug-In
Plug-In
Bolt-On
Plug-In
Plug-In
Bolt-On
Plug-In
Plug-In
Bolt-On
Plug-In
Plug-In
Bolt-On
32”
32”
32”
32”
32”
32”
32”
32”
32”
32”
32”
32”
8”
8”
8”
8”
8”
8”
8”
8”
8”
8”
8”
8”
32”
32”
38”
38”
38”
38”
32”
32”
32”
32”
32”
38”
Utility Meter Section
Customer
Distribution Section
(Padlock Provision)
Utility Termination Section
(Padlock & Sealing
Provision)
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
Meter Mounting Equipment
112
Commercial
Meter Pedestals
Accessories
• 5th jaw kit - 50365 (single phase)
• Filler plate kit - 25139
• Class T fusible pullouts
• Controls, see page 109
CMP4111M
Commercial Meter Pedestals - Pad Mounted, Unmetered
Application
• Utility meter, main disconnect and distribution panel
Construction
• Ring type
• NEMA Type 3R
• ANSI 61 gray E-coat finish
• Separate sealable utility termination and meter compartments
• Padlockable disconnect and distribution section
• Underground feed
Standards
• UL Listed
• ANSI C12.7
Accessories
• 5th jaw kit - 50365 (single phase)
• Filler plate kit - 25139
• Class T fusible pullouts
• Controls, see page 109
CUP4111
Commercial
Meter Pedestals
Catalog
Number
CUP4111
CUP4111H
CUP4121
CUP4121H
CUP4411
CUP4411H
CUP4421
CUP4421H
Amp
Rating
100
100
200
200
100
100
200
200
Service
Type
1Ø,3W
1Ø,3W
1Ø,3W
1Ø,3W
3Ø,4W
3Ø,4W
3Ø,4W
3Ø,4W
Bypass Voltage
TB
TB
TB
TB
TB
TB
TB
TB
240
480
240
480
240
480
240
480
Distribution
Main Breaker Branches
100A,2P
100A,2P
200A,2P
200A,2P
100A,3P
100A,3P
200A,3P
200A,3P
12
14
12
18
12
12
12
18
Customer
Mounting
Pad
Width
Dimensions
Depth
Height
Plug-In
Bolt-On
Plug-In
Bolt-On
Plug-In
Bolt-On
Plug-In
Bolt-On
MB1515
MB2015
MB1515
MB2015
MB1515
MB2015
MB1515
MB2015
15”
20”
15”
20”
15”
20”
15”
20”
171/2”
171/2”
171/2”
171/2”
171/2”
171/2”
171/2”
171/2”
32”
32”
32”
32”
32”
32”
32”
32”
Utility
Distribution Section
Termination Section
(Padlock & Sealing
(Padlock & Sealing
Provisions)
Front
Type
Provisions)
Side
Back
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
113
Meter Mounting Equipment
Commercial Meter Pedestals - Pad Mounted, Dual Distribution
Application
• Utility meter, main disconnect and distribution panel
• Receive ANSI C12.10 watthour meters
Construction
• Ring type
• NEMA Type 3R
• ANSI 61 gray E-coat finish
• Separate sealable utility termination and meter compartments
• Padlockable disconnect and distribution section
• Underground feed
Standards
• UL Listed
• ANSI C12.7
Catalog
Number
CMP4911M
CMP4911MC
CMP4911MCH
CMP4914M
CMP4914MC
CMP4914MCH
CMP4921M
CMP4921MC
CMP4921MCH
CMP4924M
CMP4924MC
CMP4924MCH
CMP4941MN
Amp
Rating
Jaws
Service
Type
Bypass
Voltage
100
100
100
100
100
100
200
200
200
200
200
200
400
4
4
4
7
7
7
4
4
4
7
7
7
4
1Ø, 3W
1Ø, 3W
1Ø, 3W
3Ø, 4W
3Ø, 4W
3Ø, 4W
1Ø, 3W
1Ø, 3W
1Ø, 3W
3Ø, 4W
3Ø, 4W
3Ø, 4W
1Ø, 3W
-TB
TB
-TB
TB
-TB
TB
-TB
TB
MCC
240
240
480
240
240
240
240
240
480
240
240
480
240
Distribution
Main Breaker Branch Circuits
Mounting
Pad
50A/2P (2)
50A/2P (2)
50A/2P (2)
50A/3P (2)
50A/3P (2)
50A/3P (2)
100A/2P (2)
100A/2P (2)
100A/2P (2)
100A/3P (2)
100A/3P (2)
100A/3P (2)
400A/2P (2)
MB2820
Per
Customer
Specification
Utility Meter &
Test Block
Section
Customer
Distribution Section
Customer
Main Breaker
Section
Utility
Termination
Section
Front
Side
Back
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
Meter Mounting Equipment
114
Commercial
Meter Pedestals
Accessories
• 5th jaw kit - 50365 (single phase)
• Filler plate kit - 25139
• Class T fusible pullouts
• Controls, see page 109
Commercial Meter Pedestals - Specials
Application
• Utility meter, main disconnect and distribution panel
• Receive ANSI C12.10 watthour meters
Construction
• Ring type
• NEMA Type 3R
• ANSI 61 gray E-coat finish
• Separate sealable utility termination and meter compartments
• Padlockable disconnect and distribution section
• Underground feed
Standards
• UL Listed
• ANSI C12.7
Accessories
• 5th jaw kit - 50365 (single phase)
• Filler plate kit - 25139
• Class T fused pullouts
• Controls, see page 109
Commercial
Meter Pedestals
CMP4012MC-1
Pad Mount, Dual Metered Side-by-Side - Fig. 1 (see page 116)
Catalog
Number
Amp
Rating
Jaws
Service
Type
Bypass
Voltage
CM2P4111MC-1
200
7
1Ø,3W
TB
TB
240
240
100A,2P
100A,2P
CM2P4411MC-1
200
7
1Ø,3W
TB
TB
480
480
CM2P4121MC-1
400
4
1Ø,3W
MCC
MCC
CM2P4421MC-1
400
7
3Ø,4W
TB
TB
Distribution
Main Breaker Branches
Type
Mounting
Pad
Width
Dimensions
Depth
Height
12
12
Plug-In
Plug-In
MB3215
32”
171/2”
54”
100A,2P
100A,2P
14
14
Bolt-On
Bolt-On
MB3215
32”
171/2”
54”
240
240
200A,2P
200A,2P
---
---
MB3215
32”
171/2”
54”
240
240
200A,2P
200A,2P
12
12
Plug-In
Plug-In
MB3215
32”
171/2”
54”
Type
Mounting
Pad
Width
Dimensions
Depth
Height
Pad Mount, Dual Metered - Fig. 2 (see page 116)
Catalog
Number
Amp
Rating
Jaws
Service
Type
Bypass
Voltage
Distribution
Main Breaker Branches
CMP4012MC-1
100
4
1Ø,3W
-TB
240
240
60A,2P
60A,2P
4
4
Plug-In
Plug-In
MB1515
15”
171/2”
54”
CMP4022MC-1
100
4
1Ø,3W
-TB
240
240
60A,2P
60A,2P
4
12
Plug-In
Plug-In
MB1515
15”
171/2”
54”
Type
Mounting
Pad
Width
Dimensions
Depth
Height
Plug-In
Plug-In
MB1515
15”
171/2”
54”
Pad Mount, Split Load Style - Fig. 3 (see page 116)
Catalog
Number
CMP4011SLC-1
Amp
Rating
Jaws
Service
Type
Bypass
4
1Ø,3W
TB
100
Unmetered1Ø,3W Unmetered
Voltage
240
240
Distribution
Main Breaker Branches
60A,2P
60A,2P
4
4
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
115
Meter Mounting Equipment
Commercial Meter Pedestals - Specials
Fig. 1
Utility Meter & Test
Utility Meter & Test
Block Section
Block Section
Customer
Customer
Distribution Section
Distribution Section
(Padlock Provision)
(Padlock Provision)
Utility
Termination Section
(Padlock & Sealing
Provisions)
Fig. 2
Fig. 3
Utility Meter & Test
Block Section
Utility Meter & Test
Block Section
Customer
Customer
Distribution Section
Utility
Distribution Section
(Padlock Provision)
Termination Section
(Padlock Provision)
Utility
(Padlock & Sealing
Termination Section
Provisions)
(Padlock & Sealing
Provisions)
Front
Front
Side
Side
Back
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
Meter Mounting Equipment
116
Back
Commercial
Meter Pedestals
Back
Side
Front
Notes
Commercial
Meter Pedestals
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
117
Meter Mounting Equipment