Commercial Meter Pedestals Commercial Meter Pedestals Commercial Metering Pedestals - Features & Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 Commercial Metering Pedestals - Mounting Base Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 Commercial Metering Pedestals - Pad Mounted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 Commercial Metering Pedestals - Post/Wall Mounted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 Commercial Metering Pedestals - Pad Mounted, Unmetered . . . . . . . . . . . . . . . . . . . . . . . . . 113 Commercial Metering Pedestals - Pad Mounted, Dual Distribution . . . . . . . . . . . . . . . . . . 114 Commercial Metering Pedestals - Specials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 - 116 Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Meter Mounting Equipment 108 Commercial Meter Pedestals - Features & Applications Post, Wall, or Pad Mounted Pedestals with Isloated Components for Utility Metering Name Company Name Address Phone Email Typical Application • • • • • • Street & highway lighting Traffic signal controller metering Irrigation control systems Park & recreation facilities Golf course lighting Sign lighting Commercial Meter Pedestals Construction • NEMA Type 3R • UL Listed • ANSI 12.7 • EUSERC #308 Compliant (CMP4xxx MC1) Service conductor terminations and customer’s equipment can be factory customized to meet specific job requirements Commercial Metering Pedestal - Customization Form Enclosure Mounting Type Supply Voltage Service Supply Amperage Short Circuit Rating Meter Bypass: Safety Socket (Test Block) Disconnect: Main Circuit Breaker q q Class “T” Fused Pullout Distribution: Circuit Panelboard Finish: Light Gray (ANSI 61) Light Gray (ANSI 49) q q Manual Circuit Closing None Light Green White q q q q Federal Brown q No Bypass q q Other q Switch: HOA (Hand-Off-Auto) Test Switch q Photo-E;ectric Cell: In Window Field Installed q Time Clock: 24 Hour 7 Day Electronic Mechanical q Lighting Contractor: Amps Poles Control Voltage q Thermostat: Electronic Mechanical q Cabinet Heater: Watts q Control Transformer: Amps q Duplex Receptacles: q Terminal Block Controls: For online form, see www.cooperbline/metering. Send completed form to customer service at Eaton’s B-Line Business. See address information on back cover. Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 109 Meter Mounting Equipment Installation Instructions Installation Instructions CMP-4000 Series CMP-4900 Series Meter pedestals are designed for pad-mount installation. Two methods can be used to install pedestals on a concrete pad. Meter pedestals are designed for pad-mount installation. Two methods can be used to install pedestals on a concrete pad. 1. Use pre-fabricated mounting base assembly. A. Cat. No. MB1515 Suitable for 15” wide x 15” deep pedestals. B. Cat. No. MB2015 Suitable for 20” wide x 15” deep pedestals. 1. Use pre-fabricated mounting base assembly. A. Cat. No. MB2820 Suitable for 28” wide x 20” deep pedestals. (CMP-4900 Models) Install mounting base assembly flush with top surface of concrete pad, allowing mounting studs to reach above pad. Locate line and load conduits in the designated areas as shown on drawing below. Install mounting base assembly flush with top surface of concrete pad, allowing mounting studs to reach above pad. Locate line and load conduits in the designated areas as shown on drawings below. MB2820 MB2015 261/4” 1 181/4” Line Side Line Side Line Side 6” x 141/2” Load Side Load Side (Main Section) Breaker Load Side 121/4” 121/4” 16 /4” 131/4” 2. Use anchor bolts (3/8” dia.) pre-cast in concrete pad. Mounting hole dimensions are shown above for 15 x 15 and 20 x 15 pedestals. Locate line and load conduits the same as in method 1. 10” Load Side Distribution & Control Section MB1515 2. Use anchor bolts (3/8” dia.) pre-cast in concrete pad. Mounting hole dimensions are shown above. Locate line and load conduits the same as in method 1. Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Meter Mounting Equipment 181/4” 110 Commercial Meter Pedestals Commercial Meter Pedestals - Mounting Base Details Commercial Meter Pedestals - Pad Mounted Application • Utility meter, main disconnect and distribution panel • Receive ANSI C12.10 watthour meters Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Separate sealable utility termination and meter compartments • Padlockable disconnect and distribution section • Underground feed Standards • UL Listed • ANSI C12.7 • EUSERC #308 Accessories • 5th jaw kit - 50365 (single phase) • Filler plate kit - 25139 • Class T fusible pullouts • Controls, see page 109 CMP4111MC-1 Commercial Meter Pedestals Catalog Number CMP4111MC-1 CMP4111MCH-1 CMP4121MC-1 CMP4121MCH-1 CMP4411MC-1 CMP4411MCH-1 CMP4421MC-1 CMP4421MCH-1 Amp Rating 100 100 200 200 100 100 200 200 Jaws 4 4 4 4 7 7 7 7 Service Type 1Ø,3W 1Ø,3W 1Ø,3W 1Ø,3W 3Ø,4W 3Ø,4W 3Ø,4W 3Ø,4W Bypass Voltage TB TB TB TB TB TB TB TB 240 480 240 480 240 480 240 480 Distribution Main Breaker Branches 100A,2P 100A,2P 200A,2P 200A,2P 100A,3P 100A,3P 200A,3P 200A,3P 12 14 12 18 12 12 12 18 Type Plug-In Bolt-On Plug-In Bolt-On Plug-In Bolt-On Plug-In Bolt-On Mounting Pad MB1515 MB2015 MB1515 MB2015 MB1515 MB2015 MB1515 MB2015 Width Dimensions Depth 15” 20” 15” 20” 15” 20” 15” 20” 1 17 /2” 171/2” 171/2” 171/2” 171/2” 171/2” 171/2” 171/2” Height 54” 54” 54” 54” 54” 54” 54” 54” Utility Meter & Test Block Section Customer Distribution Section (Padlock Provision) Utility Termination Section (Padlock & Sealing Provisions) Front Side Back Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 111 Meter Mounting Equipment Commercial Meter Pedestals - Post/Wall Mounted Application • Utility meter, main disconnect and distribution panel • Receive ANSI C12.10 watthour meters Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Separate sealable utility termination and meter compartments • Padlockable disconnect and distribution section • Underground feed Standards • UL Listed • ANSI C12.7 Catalog Number CMP4111M CMP4111MC CMP4111MCH CMP4121M CMP4121MC CMP4121MCH CMP4411M CMP4411MC CMP4411MCH CMP4421M CMP4421MC CMP4421MCH Amp Rating Jaws Service Type Bypass Voltage 100 100 100 200 200 200 100 100 100 200 200 200 4 4 4 4 4 4 7 7 7 7 7 7 1Ø,3W 1Ø,3W 1Ø,3W 1Ø,3W 1Ø,3W 1Ø,3W 3Ø,4W 3Ø,4W 3Ø,4W 3Ø,4W 3Ø,4W 3Ø,4W -TB TB -TB TB -TB TB -TB -- 240 240 480 240 240 480 240 240 480 240 240 480 Distribution Main Breaker Branches 100A,2P 100A,2P 100A,2P 200A,2P 200A,2P 200A,2P 100A,3P 100A,3P 100A,3P 200A,3P 200A,3P 200A,3P 12 12 14 12 12 18 12 12 12 12 12 18 Type Width Dimensions Depth Height Plug-In Plug-In Bolt-On Plug-In Plug-In Bolt-On Plug-In Plug-In Bolt-On Plug-In Plug-In Bolt-On 32” 32” 32” 32” 32” 32” 32” 32” 32” 32” 32” 32” 8” 8” 8” 8” 8” 8” 8” 8” 8” 8” 8” 8” 32” 32” 38” 38” 38” 38” 32” 32” 32” 32” 32” 38” Utility Meter Section Customer Distribution Section (Padlock Provision) Utility Termination Section (Padlock & Sealing Provision) Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Meter Mounting Equipment 112 Commercial Meter Pedestals Accessories • 5th jaw kit - 50365 (single phase) • Filler plate kit - 25139 • Class T fusible pullouts • Controls, see page 109 CMP4111M Commercial Meter Pedestals - Pad Mounted, Unmetered Application • Utility meter, main disconnect and distribution panel Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Separate sealable utility termination and meter compartments • Padlockable disconnect and distribution section • Underground feed Standards • UL Listed • ANSI C12.7 Accessories • 5th jaw kit - 50365 (single phase) • Filler plate kit - 25139 • Class T fusible pullouts • Controls, see page 109 CUP4111 Commercial Meter Pedestals Catalog Number CUP4111 CUP4111H CUP4121 CUP4121H CUP4411 CUP4411H CUP4421 CUP4421H Amp Rating 100 100 200 200 100 100 200 200 Service Type 1Ø,3W 1Ø,3W 1Ø,3W 1Ø,3W 3Ø,4W 3Ø,4W 3Ø,4W 3Ø,4W Bypass Voltage TB TB TB TB TB TB TB TB 240 480 240 480 240 480 240 480 Distribution Main Breaker Branches 100A,2P 100A,2P 200A,2P 200A,2P 100A,3P 100A,3P 200A,3P 200A,3P 12 14 12 18 12 12 12 18 Customer Mounting Pad Width Dimensions Depth Height Plug-In Bolt-On Plug-In Bolt-On Plug-In Bolt-On Plug-In Bolt-On MB1515 MB2015 MB1515 MB2015 MB1515 MB2015 MB1515 MB2015 15” 20” 15” 20” 15” 20” 15” 20” 171/2” 171/2” 171/2” 171/2” 171/2” 171/2” 171/2” 171/2” 32” 32” 32” 32” 32” 32” 32” 32” Utility Distribution Section Termination Section (Padlock & Sealing (Padlock & Sealing Provisions) Front Type Provisions) Side Back Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 113 Meter Mounting Equipment Commercial Meter Pedestals - Pad Mounted, Dual Distribution Application • Utility meter, main disconnect and distribution panel • Receive ANSI C12.10 watthour meters Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Separate sealable utility termination and meter compartments • Padlockable disconnect and distribution section • Underground feed Standards • UL Listed • ANSI C12.7 Catalog Number CMP4911M CMP4911MC CMP4911MCH CMP4914M CMP4914MC CMP4914MCH CMP4921M CMP4921MC CMP4921MCH CMP4924M CMP4924MC CMP4924MCH CMP4941MN Amp Rating Jaws Service Type Bypass Voltage 100 100 100 100 100 100 200 200 200 200 200 200 400 4 4 4 7 7 7 4 4 4 7 7 7 4 1Ø, 3W 1Ø, 3W 1Ø, 3W 3Ø, 4W 3Ø, 4W 3Ø, 4W 1Ø, 3W 1Ø, 3W 1Ø, 3W 3Ø, 4W 3Ø, 4W 3Ø, 4W 1Ø, 3W -TB TB -TB TB -TB TB -TB TB MCC 240 240 480 240 240 240 240 240 480 240 240 480 240 Distribution Main Breaker Branch Circuits Mounting Pad 50A/2P (2) 50A/2P (2) 50A/2P (2) 50A/3P (2) 50A/3P (2) 50A/3P (2) 100A/2P (2) 100A/2P (2) 100A/2P (2) 100A/3P (2) 100A/3P (2) 100A/3P (2) 400A/2P (2) MB2820 Per Customer Specification Utility Meter & Test Block Section Customer Distribution Section Customer Main Breaker Section Utility Termination Section Front Side Back Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Meter Mounting Equipment 114 Commercial Meter Pedestals Accessories • 5th jaw kit - 50365 (single phase) • Filler plate kit - 25139 • Class T fusible pullouts • Controls, see page 109 Commercial Meter Pedestals - Specials Application • Utility meter, main disconnect and distribution panel • Receive ANSI C12.10 watthour meters Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Separate sealable utility termination and meter compartments • Padlockable disconnect and distribution section • Underground feed Standards • UL Listed • ANSI C12.7 Accessories • 5th jaw kit - 50365 (single phase) • Filler plate kit - 25139 • Class T fused pullouts • Controls, see page 109 Commercial Meter Pedestals CMP4012MC-1 Pad Mount, Dual Metered Side-by-Side - Fig. 1 (see page 116) Catalog Number Amp Rating Jaws Service Type Bypass Voltage CM2P4111MC-1 200 7 1Ø,3W TB TB 240 240 100A,2P 100A,2P CM2P4411MC-1 200 7 1Ø,3W TB TB 480 480 CM2P4121MC-1 400 4 1Ø,3W MCC MCC CM2P4421MC-1 400 7 3Ø,4W TB TB Distribution Main Breaker Branches Type Mounting Pad Width Dimensions Depth Height 12 12 Plug-In Plug-In MB3215 32” 171/2” 54” 100A,2P 100A,2P 14 14 Bolt-On Bolt-On MB3215 32” 171/2” 54” 240 240 200A,2P 200A,2P --- --- MB3215 32” 171/2” 54” 240 240 200A,2P 200A,2P 12 12 Plug-In Plug-In MB3215 32” 171/2” 54” Type Mounting Pad Width Dimensions Depth Height Pad Mount, Dual Metered - Fig. 2 (see page 116) Catalog Number Amp Rating Jaws Service Type Bypass Voltage Distribution Main Breaker Branches CMP4012MC-1 100 4 1Ø,3W -TB 240 240 60A,2P 60A,2P 4 4 Plug-In Plug-In MB1515 15” 171/2” 54” CMP4022MC-1 100 4 1Ø,3W -TB 240 240 60A,2P 60A,2P 4 12 Plug-In Plug-In MB1515 15” 171/2” 54” Type Mounting Pad Width Dimensions Depth Height Plug-In Plug-In MB1515 15” 171/2” 54” Pad Mount, Split Load Style - Fig. 3 (see page 116) Catalog Number CMP4011SLC-1 Amp Rating Jaws Service Type Bypass 4 1Ø,3W TB 100 Unmetered1Ø,3W Unmetered Voltage 240 240 Distribution Main Breaker Branches 60A,2P 60A,2P 4 4 Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 115 Meter Mounting Equipment Commercial Meter Pedestals - Specials Fig. 1 Utility Meter & Test Utility Meter & Test Block Section Block Section Customer Customer Distribution Section Distribution Section (Padlock Provision) (Padlock Provision) Utility Termination Section (Padlock & Sealing Provisions) Fig. 2 Fig. 3 Utility Meter & Test Block Section Utility Meter & Test Block Section Customer Customer Distribution Section Utility Distribution Section (Padlock Provision) Termination Section (Padlock Provision) Utility (Padlock & Sealing Termination Section Provisions) (Padlock & Sealing Provisions) Front Front Side Side Back Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Meter Mounting Equipment 116 Back Commercial Meter Pedestals Back Side Front Notes Commercial Meter Pedestals Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 117 Meter Mounting Equipment