1 GENERAL SHEET NOTES OUTDOOR WALKWAY 1523 OFFICE 1508 ELECT./ JAN. 1524 CONFERENCE STORAGE 1525 WOMEN 1526 MEN DUCT SHAFT 1522-A CLASSROOM 1520A OFFICE 1520 CLASSROOM 1520E STORAGE OUTDOOR WALKWAY EXAM OUTDOOR WALKWAY 4 TYP. 1520 CLASSROOM 1522B CLASSROOM 1522A CLASSROOM 1521A CLASSROOM 1521B CLASSROOM STORAGE OUTDOOR WALKWAY LEVEL 2 KEY PLAN 2 A1.01 1/8" = 1'-0" 1 A3.01 1 3 1503B OFFICE 1503C OFFICE 1504A OFFICE 1504B OFFICE 3 3 1505 6 1506A OFFICE 3 6 3 6 3 6 1506B 1506C 1506D OFFICE OFFICE OFFICE 2 2 A3.01 CORRIDOR S 4 1500A STORAGE 1503 ENTRY 1505B W RESTROOM 1505A M RESTROOM PRESCHOOL KITCHEN 5 1508B MAIL ROOM 1512 OBSERVATION 1508A RECEPTION OFFICE 6 1501A OBSERVATION ANTE ROOM 1502 TODDLER DROP OFF 1500 PRESCHOOL CLASSROOM 1509 PLAY ROOM 1500C OBSERVATION SUBCONSULTANT GLASS Associates, Inc. architecture & planning 300 Lakeside Drive, Suite 1081 Oakland, CA 94612 T. 415.864.1234 www.glassarchplan.com © 2016 GLASS Associates, Inc. architecture & planning REFER TO ELECTRICAL DRAWINGS FOR LIGHTING DEMOLITION AND REPLACEMENT! ! ! REFER TO MECHANICAL DRAWINGS FOR HVAC & PLUMBING DEMOLITION AND MODIFICATIONS.! ! ! (N) FIXED WINDOWS AND SPANDRELS TO REPLACE (E) WINDOWS AND SLIDING DOORS @ OFFICES 1503A, 1505, 1506A - 1506D, AND BREAK ROOM 1507; REFER TO SHEETS A3.01, A6.01, AND THE SPECIFICATIONS.! ! AREAS OF ACOUSTICAL CEILING SYSTEM WORK SHOWN SHADED;! REFER TO GENERAL SHEET NOTES, LEGEND, SHEETS A1.02, A6.01, AND THE SPECIFICATIONS.! ! (N) FURRING, INSULATION, VAPOR BARRIER, PAINTED GYPSUM BOARD FINISH, AND RESILIENT BASE AT WEST AND SOUTH WALLS OF LEVEL 1 OFFICE 1503A. FURRED ASSEMBLY SHALL EXTEND ABOVE CEILING & OVER WINDOWS TO UNDERSIDE OF STRUCTURE ABOVE; REFER TO SHEETS A3.01, A6.01, AND THE SPECIFICATIONS.! ! ADDITIVE ALTERNATE B: (N) FURRING, INSULATION, VAPOR BARRIER, PAINTED GYPSUM BOARD FINISH, AND RESILIENT BASE AT NORTH WALLS OF LEVEL 1 OFFICES 1505 & 1506A-1506D. FURRED ASSEMBLY SHALL EXTEND ABOVE CEILING & OVER WINDOWS TO UNDERSIDE OF STRUCTURE ABOVE; REFER TO SHEETS A3.01, A6.01, AND THE SPECIFICATIONS.! ! ! ! ! 1 1508C COPY 3 W A3.01 ALL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE 2013 C.B.C. AND ADOPTED AMENDMENTS.! ! ALL ACOUSTICAL CEILING SYSTEM WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE 2013 C.B.C. & DSA IR 25-2.10 (REV 05-16-13) - METAL SUSPENSION SYSTEMS FOR LAY-IN PANEL CEILINGS. REFER TO INSTALLATION DETAILS AND STANDARDS ON SHEET A6.01.! ! SUMMARY SCOPE OF ARCHITECTURAL WORK:! ! BASE BID: ! ! • REPLACE (E) WINDOWS AND SLIDING DOORS WITH (N) FIXED! WINDOWS AND SPANDRELS AT OFFICES 1503A, 1505, 1506A -! 1506D, AND BREAK ROOM 1507 (LOW-E INSULATED GLASS;! INSULATED SPANDRELS; THERMAL BREAK FRAMES); REFER TO! SHEETS A3.01, A6.01, AND THE SPECIFICATIONS.! ! • REMOVE AND REPLACE ACOUSTIC CEILING PANELS AT AREAS! INDICATED FOR LEVELS 1 AND 2; REFER TO SHEETS A1.02, A6.01,! AND THE SPECIFICATIONS.! ! • PROVIDE (N) FURRING, INSULATION, VAPOR BARRIER, PAINTED! GYPSUM BOARD FINISH, AND RESILIENT BASE AT WEST AND! SOUTH WALLS OF LEVEL 1 OFFICE 1503A. FURRED ASSEMBLY! SHALL EXTEND ABOVE CEILING & OVER WINDOWS TO UNDER-! SIDE OF STRUCTURE ABOVE; REFER TO SHEETS A3.01, A6.01,! AND THE SPECIFICATIONS.! ! • REMOVE AND REPLACE ACOUSTIC CEILING GRID ONLY AS! REQUIRED TO ACCOMMODATE (N) FURRING AT LEVEL 1 OFFICE! 1503A; REFER TO SHEETS A1.02, A6.01, AND THE SPECIFICATIONS.! ! ADDITIVE ALTERNATE A: REMOVE AND REPLACE ACOUSTIC CEILING GRID AT AREAS INDICATED FOR LEVELS 1 AND 2; REFER TO SHEETS A4.01, A6.01, AND THE SPECIFICATIONS.! ! ADDITIVE ALTERNATE B: ! ! • PROVIDE (N) FURRING, INSULATION, VAPOR BARRIER, PAINTED! GYPSUM BOARD FINISH, AND RESILIENT BASE AT NORTH WALLS! OF LEVEL 1 OFFICES 1505 & 1506A-1506D. FURRED ASSEMBLY! SHALL EXTEND ABOVE CEILING & OVER WINDOWS TO UNDER-! SIDE OF STRUCTURE ABOVE; REFER TO SHEETS A3.01, A6.01,! AND THE SPECIFICATIONS.! ! • REMOVE AND REPLACE ACOUSTIC CEILING GRID ONLY AS! REQUIRED TO ACCOMMODATE (N) FURRING AT LEVEL 1 NORTH! OFFICES 1505 & 1506A-1506D; REFER TO SHEETS A1.02, A6.01,! AND THE SPECIFICATIONS.! ! BASE BID & ADDITIVE ALTERNATES: CEILING SYSTEMS SHALL BE INSTALLED AT HEIGHTS MATCHING EXISTING.! ! ! ALL DIMENSIONS TO FINISH FACE UNLESS OTHERWISE NOTED.! ! ALL NEW FURING TO BE 2 X 4 STUDS @ 24" O.C. RIPPED TO DIMENSION OF INSULATION PANEL THICKENESS W/ 5/8" GYP. BD. @ OFFICE SIDES, U.O.N.! ! GENERAL CONTRACTOR SHALL COORDINATE WITH ALL TRADES INVOLVED TO ENSURE CLEARANCES FOR FIXTURES, DUCTS, CEILINGS, ETC. NECESSARY TO MAINTAIN THE SPECIFIED FINISH CEILING HEIGHT ABOVE THE FINISH FLOOR SLAB AS NOTED ON THE DRAWINGS. REVIEW CONFLICTS WITH ARCHITECT. CEILING GRID REFRAMING CHANGES DUE TO CEILING CONFLICTS MUST BE APPROVED BY COLLEGE REPRESENTATIVE.! ! GENERAL CONTRACTOR SHALL PROVIDE PROTECTION TO ALL EXISTING FINISHES IN PUBLIC CORRIDORS AND EXISTING FINISHED SPACES DESIGNATED TO REMAIN AND SHALL BE RESPONSIBLE TO REPAIR ANY DAMAGE CAUSED BY THE CONTRACTOR OR BY ITS SUBCONTRACTORS. ! ! REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL DEMOLITION RELATED TO CEILING DEMOLITION.! ! REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF SMOKE ALARMS, FIRE & LIFE SAFETY STROBE LIGHTS / SPEAKERS, AND ELECTIRCAL & LIGHTING-RELATED WORK.! ! REFER TO MECHANICAL DRAWINGS FOR HVAC & PLUMBING DEMOLITION RELATED TO CEILING DEMOLITION.! ! REFER TO MECHANICAL DRAWINGS FOR PLUMBING & HVACRELATED WORK! NUMBERED SHEET NOTES 1507 BREAK JAN. 2 5 3 6 ELECT. OFFICE 1503A OFFICE 2 1)! ! ! ! ! 2)! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! 3)! ! 4)! ! ! ! 5)! ! ! ! ! ! ! ! 6)! ! ! ! ! ! 7)! ! ! 8)! ! ! ! 9)! ! ! 10) BUILDING 1500 KEY PLANS & ARCHITECTURAL SCOPE 2 BUILDINGS 1400 & 1500 HVAC & LIGHTING RENOVATIONS 1 CABRILLO COLLEGE A3.01 4 TYP. ISSUANCES & REVISIONS NO. - DATE 12/21/15 DESCRIPTION ISSUED FOR DSA REVIEW PLAN LEGEND 1508 CLASSROOM (E) STRUCTURE / PARTITION TO REMAIN STOR. (N) FULL-HEIGHT INSULATED FURRING BOILER (N) CEILING-HEIGHT WINDOW WALL W/ INSULATED SPANDREL. 1510 1501 NAP 1 TODDLER 1 WINDOW KEY; SEE SHEET A3.01 SHADED AREAS INDICATE LOCATIONS OF! ACOUSTICAL CEILING SYSTEMS WORK CLASSROOM 0 REF. N 8 STAMP 16 FILE NO. 44-C1 DISCLAIMER IDENTIFICATION STAMP DIV. OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES LEVEL 1 KEY PLAN 1/8" = 1'-0" 1 A1.01 THE DATA SET FORTH ON THIS SHEET IS THE PROPERTY OF YOUNG ENGINEERING SERVICES. IT IS AN INSTRUMENT OF SERVICE AND MAY NOT BE ALTERED, REPRODUCED OR USED WITHOUT THE CONSENT OF YOUNG ENGINEERING SERVICES. THE PROPER TRANSFER OF DATA HEREIN, ELECTRONICALLY OR OTHERWISE, SHALL BE THE RESPONSIBILITY OF THE USER WITHOUT LIABILITY TO YOUNG ENGINEERING SERVICES. UNAUTHORIZED USE IS PROHIBITED. SHEET NO. AC:_________FLS_________SS__________ DATE:________________________________ A1.01 1 2 3 REFLECTED CEILING PLAN NOTES 1524 CONFERENCE STORAGE 1525 WOMEN 1526 MEN DUCT SHAFT 1520A 1520 CLASSROOM OFFICE 1520E STORAGE 1522-A CLASSROOM OUTDOOR WALKWAY EXAM OUTDOOR WALKWAY 1520 CLASSROOM 1521A CLASSROOM 1521B CLASSROOM 1522B CLASSROOM STORAGE 1522A CLASSROOM OUTDOOR WALKWAY LEVEL 2 REFLECTED CEILING PLAN 2 architecture & planning 300 Lakeside Drive, Suite 1081 Oakland, CA 94612 T. 415.864.1234 www.glassarchplan.com © 2016 GLASS Associates, Inc. architecture & planning REFLECTED CEILING PLAN LEGEND A1.02 1/8" = 1'-0" EXHAUST-AIR ! REGISTER;! SEE MECHANICAL 1 2 3 SUPPLY AIR LINEAR ! SLOT DIFFUSER; SEE ! MECHANICAL (N) 2 x 4 LIGHTING ! FIXTURE; SEE ! ELECTICAL ILLUMINATED ! EXIT SIGN;! SEE ELECTRICAL (N) 2' X 4'! AC CEILING GRID BUILDING 1500 REFLECTED CEILING PLANS & NOTES 1523 OFFICE 1508 ELECT./ JAN. GLASS Associates, Inc. BUILDINGS 1400 & 1500 HVAC & LIGHTING RENOVATIONS OUTDOOR WALKWAY SUBCONSULTANT ALL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE 2013 C.B.C. & DSA IR 25-2.10 (REV 05-16-13) - METAL SUSPENSION SYSTEMS FOR LAY-IN PANEL CEILINGS. REFER TO INSTALLATION DETAILS AND STANDARDS ON SHEET A6.01.! ! ACOUSTICAL CEILING SYSTEM WORK:! ! BASE BID: ! ! • REMOVE AND REPLACE ACOUSTIC CEILING PANELS AT AREAS! INDICATED FOR LEVELS 1 AND 2. ! ! • REMOVE AND REPLACED ACOUSTIC CEILING GRID ONLY AS! REQUIRED TO ACCOMMODATE (N) FURRING AT LEVEL 1 OFFICE! 1503A.! ! ADDITIVE ALTERNATE A: REMOVE AND REPLACE ACOUSTIC CEILING GRID AT AREAS INDICATED FOR LEVELS 1 AND 2. ! ! ADDITIVE ALTERNATE B: REMOVE AND REPLACED ACOUSTIC CEILING GRID ONLY AS REQUIRED TO ACCOMMODATE (N) FURRING AT LEVEL 1 NORTH OFFICES 1505 & 1506A-1506D.! ! BASE BID & ADDITIVE ALTERNATES: CEILING SYSTEMS SHALL BE INSTALLED AT HEIGHTS MATCHING EXISTING.! ! NO CEILING REMOVAL OR REPLACEMENT WORK AT ANY OTHER LOCATIONS SHALL BE CONDUCTED BY THE CONTRACTOR WITHOUT APPROVAL OF THE DIVISION OF THE STATE ARCHITECT (DSA). ! ! GENERAL CONTRACTOR SHALL COORDINATE WITH ALL TRADES INVOLVED TO ENSURE CLEARANCES FOR FIXTURES, DUCTS, CEILINGS, ETC. NECESSARY TO MAINTAIN THE SPECIFIED FINISH CEILING HEIGHT ABOVE THE FINISH FLOOR SLAB AS NOTED ON THE DRAWINGS. REVIEW CONFLICTS WITH ARCHITECT. CEILING GRID REFRAMING CHANGES DUE TO CEILING CONFLICTS MUST BE APPROVED BY COLLEGE REPRESENTATIVE.! ! GENERAL CONTRACTOR SHALL PROVIDE PROTECTION TO ALL EXISTING FINISHES IN PUBLIC CORRIDORS AND EXISTING FINISHED SPACES DESIGNATED TO REMAIN AND SHALL BE RESPONSIBLE TO REPAIR ANY DAMAGE CAUSED BY THE CONTRACTOR OR BY ITS SUBCONTRACTORS. ! ! REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL DEMOLITION RELATED TO CEILING DEMOLITION.! ! REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF SMOKE ALARMS, FIRE & LIFE SAFETY STROBE LIGHTS / SPEAKERS, AND ELECTIRCAL & LIGHTING-RELATED WORK.! ! REFER TO MECHANICAL DRAWINGS FOR HVAC & PLUMBING DEMOLITION RELATED TO CEILING DEMOLITION.! ! REFER TO MECHANICAL DRAWINGS FOR PLUMBING & HVACRELATED WORK! CABRILLO COLLEGE 1)! ! ! ! ! 2)! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! 3)! ! ! ! ! ! ! ! 4)! ! ! ! ! ! 5)! ! ! 6)! ! ! ! 7)! ! ! 8) CEILING ! HEIGHT TO! MATCH (E) 1503B OFFICE 1503C OFFICE ELECT. 1504A OFFICE 1504B OFFICE 1503A 1505 JAN. 1506A OFFICE 1506B 1506C 1506D OFFICE OFFICE OFFICE 1508C COPY 1507 BREAK RETURN-AIR ! REGISTER; SEE! MECHANICAL OFFICE SHADED AREAS INDICATE LOCATIONS OF! ACOUSTICAL CEILING SYSTEMS WORK CORRIDOR OFFICE 1500A STORAGE 1505B W RESTROOM 1505A M RESTROOM PRESCHOOL KITCHEN ISSUANCES & REVISIONS 1508B 1503 ENTRY NUMBERED SHEET NOTES 1508A MAIL ROOM 1 1501A OBSERVATION 1509 PLAY ROOM 1502 TODDLER DROP OFF 2 1500 PRESCHOOL CLASSROOM 1500C OBSERVATION NO. - RECEPTION OFFICE 1512 OBSERVATION ANTE ROOM SUPPLY AIR ! DIFFUSER;! SEE MECHANICAL 3 1508 CLASSROOM DATE 12/21/15 DESCRIPTION ISSUED FOR DSA REVIEW AREAS OF ACOUSTICAL CEILING SYSTEM WORK SHOWN SHADED;! REFER TO REFLECTED CEILING PLAN NOTES AND LEGEND.! ! ! REFER TO ELECTRICAL DRAWINGS FOR LIGHTING DEMOLITION AND REPLACEMENT! ! ! REFER TO MECHANICAL DRAWINGS FOR HVAC & PLUMBING DEMOLITION AND MODIFICATIONS.! STOR. BOILER 1501 TODDLER CLASSROOM 1510 NAP 1 REF. N 0 8 STAMP 16 FILE NO. 44-C1 DISCLAIMER IDENTIFICATION STAMP DIV. OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES LEVEL 1 REFLECTED CEILING PLAN 1/8" = 1'-0" 1 A1.02 THE DATA SET FORTH ON THIS SHEET IS THE PROPERTY OF YOUNG ENGINEERING SERVICES. IT IS AN INSTRUMENT OF SERVICE AND MAY NOT BE ALTERED, REPRODUCED OR USED WITHOUT THE CONSENT OF YOUNG ENGINEERING SERVICES. THE PROPER TRANSFER OF DATA HEREIN, ELECTRONICALLY OR OTHERWISE, SHALL BE THE RESPONSIBILITY OF THE USER WITHOUT LIABILITY TO YOUNG ENGINEERING SERVICES. UNAUTHORIZED USE IS PROHIBITED. SHEET NO. AC:_________FLS_________SS__________ DATE:________________________________ A1.02 ELEVATION & WINDOW SHEET NOTES SUBCONSULTANT SIM. AT WEST! ELEV - RM 1503A 1 1 1)! ! ! ! ! ! 2)! ! ! 3)! ! 4)! ! 5)! ! 6)! ! ! 7)! ! THESE SHEET NOTES INCLUDE BOTH GENERAL AND SPECIFIC! SCOPE ITEMS. SPECIFIC ITEMS ARE KEYED IN THE DRAWING TO! ASSIST CONTRACTOR IN IDENTIFYING LOCATION OF WORK. ! NOTES NOT KEYED IN THE DRAWING SHOULD BE CONSIDERED ! AS GENERAL OR TYPICAL AND APPLY TO ALL AREAS OF THE WORK.! ! REFER TO SHEET G2.04 FOR DOOR SWING CLEARANCES REQUIRED FOR ACCESSIBILITY! ! REFER TO SHEETS A1.01 FOR PLAN INFORMATION & SCOPE OF WORK NOTES.! ! REFER TO SHEETS A1.02 FOR REFLECTED CEILING PLANS.! ! REFER TO SHEETS A6.01 FOR CONSTRUCTION DETAILS INFORMATION.! ! ALL FINISH MATERIALS SHALL MEET APPLICABLE FIRE AND SAFETY REQUIREMENTS OF CBC 2013.! ! FIELD MEASURE ALL WINDOW OPENINGS PRIOR TO FABRICATION OF NEW WINDOWS. GLASS Associates, Inc. architecture & planning 300 Lakeside Drive, Suite 1081 Oakland, CA 94612 T. 415.864.1234 www.glassarchplan.com © 2016 GLASS Associates, Inc. architecture & planning 1 3 1 1 1 2 1 1 1 1 1 3 0 8 2 16 NORTH BUILDING ELEVATION 1 A3.01 1/8" = 1'-0" 3 ELEV. UNDERSIDE OF STRUCTURE! ABOVE FIN. FLOOR; CONTRACTOR ! TO VERIFY IN FIELD 1 SEE 15 1 1 1 1 15 TYP. 2 1 1 1 3 A6.01 A6.01 OFFICE 1505 OFFICE 1506A OFFICE 1506B OFFICE 1506C OFFICE 1506D BREAK ROOM 1507 8 0 4 8 NORTH WALL INTERIOR ELEVATIONS - LEVEL 1 3 A3.01 2 A3.01 1/4" = 1'-0" 3'-5" (NOM.) 7 3'-8" (NOM.) V.I.F. 7 A6.01 6'-0" (NOM.) V.I.F. 7 A6.01 V.I.F. A6.01 EQ. 9 9 9 A6.01 A6.01 A6.01 EQ. ISSUANCES & REVISIONS NO. 12 A6.01 10 A6.01 14 A6.01 10'-3" - VERIFY IN FIELD - 6'-11" 4 1 16 3'-2" 1/4" = 1'-0" 3 3 TYP. @! OFFICES WEST 0 OFFICE 1503A 1 INSULATED TEMPERED! GLASS LITES, TYPICAL 12 DATE 12/21/15 DESCRIPTION ISSUED FOR DSA REVIEW 12 A6.01 A6.01 10 10 8 A6.01 A6.01 A6.01 INSULATED SPANDREL,! TYP. @ LOWER PANEL 14 A6.01 13 14 A6.01 A6.01 4" SOUTH TYP.,! SEE RESIL. BASE,! TYP. A6.01 CABRILLO COLLEGE 1 3 10'-3" - V.I.F. 2 FLOOR TO CEILING PARTITIONS! TYP. BETWEEN OFFICES 13'-5" - V.I.F. ELEV. CLG. ABOVE FIN. FLOOR! & HEIGHT OF WINDOW WALL;! CONTRACTOR TO VERIFY! IN FIELD (N) FIXED WINDOWS AND SPANDRELS TO REPLACE (E) WINDOWS AND SLIDING DOORS @ OFFICES 1503A, 1505, 1506A - 1506D, AND BREAK ROOM 1507; REFER TO SHEET A6.01, AND THE SPECIFICATIONS.! ! (N) FURRING, INSULATION, VAPOR BARRIER, PAINTED GYPSUM BOARD FINISH, AND RESILIENT BASE AT WEST AND SOUTH WALLS OF LEVEL 1 OFFICE 1503A. FURRED ASSEMBLY SHALL EXTEND ABOVE CEILING & OVER WINDOWS TO UNDERSIDE OF STRUCTURE ABOVE (SHOWN HATCHED); REFER TO A6.01, AND THE SPECIFICATIONS.! ! ADDITIVE ALTERNATE B: (N) FURRING, INSULATION, VAPOR BARRIER, PAINTED GYPSUM BOARD FINISH, AND RESILIENT BASE AT NORTH WALLS OF LEVEL 1 OFFICES 1505 & 1506A-1506D. FURRED ASSEMBLY SHALL EXTEND ABOVE CEILING & OVER WINDOWS TO UNDERSIDE OF STRUCTURE ABOVE (SHOWN HATCHED); REFER TO SHEETS A6.01, AND THE SPECIFICATIONS.! BUILDINGS 1400 & 1500 HVAC & LIGHTING RENOVATIONS 1 BUILDING 1500 EXTERIOR & INTERIOR ELEVATIONS AND WINDOW TYPES NUMBERED SHEET NOTES STAMP 1 11 A6.01 2 11 A6.01 3 11 A6.01 0 WINDOW TYPES 1/2" = 1'-0" 2 4 4 A3.01 FILE NO. 44-C1 DISCLAIMER IDENTIFICATION STAMP DIV. OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES THE DATA SET FORTH ON THIS SHEET IS THE PROPERTY OF YOUNG ENGINEERING SERVICES. IT IS AN INSTRUMENT OF SERVICE AND MAY NOT BE ALTERED, REPRODUCED OR USED WITHOUT THE CONSENT OF YOUNG ENGINEERING SERVICES. THE PROPER TRANSFER OF DATA HEREIN, ELECTRONICALLY OR OTHERWISE, SHALL BE THE RESPONSIBILITY OF THE USER WITHOUT LIABILITY TO YOUNG ENGINEERING SERVICES. UNAUTHORIZED USE IS PROHIBITED. SHEET NO. AC:_________FLS_________SS__________ DATE:________________________________ A3.01 WINDOW WALL DETAILS WEB! AS OCCURS architecture & planning CAULK &! BACKER! ROD A6.01 6" = 1'-0" 4 1/2" O.D. HANGER WIRE;! BRACE WIRE;! SEE SADDLE TIE! SEE SADDLE TIE! DET. DET. 12 A6.01 6" = 1'-0" 1/16" REVEAL, TYP. 5/8" GYP. BD. O/ RIGID INSULATION O/ (E) C.M.U. EXTERIOR WALL DETAIL @ HEAD 7 A6.01 6" = 1'-0" ALUM. STOREFRONT! W/ INSULATED GLASS! LITES AND THERMAL! BREAKS; HEAVY-DUTY! SECTION AT VERTICAL! MULLION; SEE SPECS. ALUMINUM TRANSOM ! PANEL O/ RIGID INSUL'N;! SECURE TO FRAME W/! CONCEALED CLIPS;! ALUM. VAPOR RE-! TARDER ON ROOM SIDE TYP. SADDLE TIE DETAIL ! AT TRUSS JOIST BRACING & HANGER WIRE DET.! @ TRUSS CHORD 45º MAX.,! TYP. © 2016 GLASS Associates, Inc. architecture & planning CROSS ! RUNNER MAIN RUNNER 12 GA. VERTICAL HANGER! WIRE @ 4'-0" EA. WAY! (4'-0" O.C. AT MAIN RUNNER)! MINIMUM (3) TIGHT TURNS! IN 3" BOTH ENDS, TYP. 2" MAX. FROM BRACING! WIRES TO COMPRESSION! STRUT AND CROSS RUNNER ACOUST'L CLG. GRID ATTACHMENT NOTE: REFER TO ELECTRICAL DRAWINGS FOR! BRACING OF LUMINAIRES. MAIN RUNNER CROSS RUNNER HANGER WIRE;! TO EYE-HOOK BRACE WIRE! TO EYE HOOK ACOUSTIC PANEL 2" DETAIL @ VERTICAL MULLION 13 A6.01 6" = 1'-0" DETAIL @ VERTICAL MULLION 8 A6.01 6" = 1'-0" ALUM. STOREFRONT! W/ INSULATED GLASS! LITES AND THERMAL! BREAKS; SEE SPECS. O.D. 5 A6.01 N.T.S. COMPRESSION STRUT FOR! EVERY 80 S.F. OF CEILING W/! 10'-0" MAX. SPAN (USE 1/2" EMT! FOR LENGTHS TO 3'-9"; USE 3/4"! EMT FOR LENTHS 3'-9" TO 5'-0";! USE 1 1/2" EMT FOR LENTHS! 5'-0" TO 10'-0") 2 x 6 BLOXCKING FULL! WIDTH BETWEEN TRUSS! JOISTS AT ROOF DECK;! 1/4" DIA. X 2" LAG INTO ! WD. BLOCK'G DET. @ HANGER WIRE ! ATTACHMENT TO GRID ALUM. STOREFRONT! W/ INSULATED GLASS! LITES AND THERMAL! BREAKS; SEE SPECS. A6.01 SPACERS MAY BE SLOTTED ANGLES! OR CHANNELS W/ "DIAMOND POINTS"! OF SPRING STEEL WHICH SNAP TIGHT! TO PREVENT MOVEMENT OF STRUT CHANNEL ALTERNATE SPREADER STRUT 12 GA. HANGER WIRE (3) TIGHT TURNS IN ! 3" MAX. 8" MAX. 1/4" DIA. M.B. ALUMINUM ! TRANSOM PANEL! SET IN GLAZING! ADAPTER 2 N.T.S. #12 GA. G.S. WIRE SPLAY! 4 WAYS; PLACE @ 45 DEG. TO! HORIZ., WIRES TO BE PARALLEL ! TO " " RUNNER 2" ALUMINUM TRANSOM ! PANEL O/ RIGID INSUL'N;! SECURE TO FRAME W/! CONCEALED CLIPS;! ALUM. VAPOR RE-! TARDER ON ROOM SIDE CAULK &! BACKER! ROD BRACING & HANGER WIRE DET.! @ 2x & 4x FLOOR & ROOF FRAMING OR 1/4 OF LENGTH ! OF END RUNNER,! WHICHEVER IS LESS. 8" MAX. ALTERNATE LOCATION ! W/OUT NAIL; NOTCHING! PERMITTED ONLY AT! RUNNER OR 1/4 OF LENGTH ! OF END RUNNER,! WHICHEVER IS LESS. 3/4" 4 1/2" INLAID! ACCUSTIC PANEL 9 A6.01 6" = 1'-0" BRACING @ COMPRESSION STRUT N.T.S. MAIN OR! CROSS ! RUNNER 6 A6.01 ACOUSTIC PANEL POP RIVET; SEE NOTE 1) BELOW ALUM. STOREFRONT! W/ INSULATED GLASS! LITES AND THERMAL! BREAKS; SEE SPECS. WALL ANGLE WALL CONNECTION -! ANCHOR TO STRUCTURAL! ELEMENT 2" 4 1/2" ALUMINUM TRANSOM ! PANEL O/ RIGID INSUL'N;! SECURE TO FRAME W/! CONCEALED CLIPS;! ALUM. VAPOR RE-! TARDER ON ROOM SIDE DETAIL @ HORIZONTAL MULLION 10 A6.01 6" = 1'-0" ALUMINUM ! TRANSOM PANEL! SET IN GLAZING! ADAPTER CAULK &! BACKER! ROD, TYP. SLOTTED ANGLE SPACER! W/ HORIZ. 6D RINGSHANK! NAIL; (2) NAILS AT THE END ! OF HORIZONTAL STRUTS ARE ! TO BE PLACED WITH NAIL ! HEAD TOWARD CENTERLINE ! OF SPAN OF STRUT. NOTES:! ! 1) IR 25-2.10 SEC. 3.3: ! CEILING GRID MEMBERS SHALL BE ATTACHED TO TWO (2) ! ADJACENT WALLS PER ASTM E580, SECTION 5.2.3. CEILING ! GRID MEMBERS SHALL BE AT LEAST 3/4 INCH CLEAR OF ! OTHER WALLS. IF WALLS RUN DIAGONALLY TO CEILING ! GRID SYSTEM RUNNERS, ONE END OF MAIN AND CROSS ! RUNNERS SHOULD BE FREE, AND A MINIMUM OF 3/4 INCH ! CLEAR OF WALL. 1/16" REVEAL ALUMINUM ! TRANSOM PANEL! SET IN GLAZING! ADAPTER 2 1/4" A6.01 DETAIL @ HORIZONTAL MULLION CEILING HANGER DETS. @ HORIZ.! STRUT & CONNECTION TO PERIM. 3 A6.01 N.T.S. ALUMINUM TRANSOM ! PANEL O/ RIGID INSUL'N;! SECURE TO FRAME W/! CONCEALED CLIPS ALUM. STOREFRONT! W/ THERMAL BREAKS; ! SEE SPECS. RESIL. BASE 4" 6" = 1'-0" 14 O.D. DETAIL @ JAMB 2" MAX. 1/16" REVEAL 4" A6.01 (3) TIGHT TURNS IN 3" MAX. ALUMINUM ! TRANSOM PANEL! SET IN GLAZING! ADAPTER A6.01 N.T.S. 1 12 GA. HANGER WIRE 1/2"D x 1-1/4" No. 4 G.S.M. ! EYEHOOK;! HANGER WIRES (3) TIGHT ! TURNS & BRACING WIRES! (4) TIGHT TURNS 16 300 Lakeside Drive, Suite 1081 Oakland, CA 94612 T. 415.864.1234 www.glassarchplan.com WOOD 2x OR 4x FLOOR! OR ROOF JOIST AS OCCURS ALUM. STOREFRONT! W/ INSULATED GLASS! LITES AND THERMAL! BREAKS; HEAVY-DUTY! SECTION AT VERTICAL! MULLION; SEE SPECS. 2" 6" = 1'-0" 4 A6.01 N.T.S. RESIL. BASE SECTION @ FURRED WALL BASE 45º MAX.,! TYP. HANGER WIRES (3) TIGHT ! TURNS & BRACING WIRES! (4) TIGHT TURNS TYP. DETAIL AT TRUSS JOIST 5" DETAIL @ JAMB 12 GA. BRACING WIRE! W/ MIN. (4) TIGHT TURNS! IN 1-1/2" BOTH ENDS! OF WIRE CONNECTED! TO MAIN TUNNERS, TYP. CABRILLO COLLEGE 15 NOTE: SEE DETAILS THIS ! SHEET FOR CONNECTIONS! OF BRACING & HANGER ! WIRE TO STRUCTURE ABOVE. GLASS Associates, Inc. ALUM. STOREFRONT! W/ INSULATED GLASS! LITES AND THERMAL! BREAKS; SEE SPECS. PLAN SECTION @ FURRED WALL COMPRESSION STRUT 2 1/4" O.D. CAULK &! BACKER! ROD 5/8" GYP. BD. O/ 1-1/2" WOOD FURRING STRIPS @ 24" O.C. W/ RIGID INSULATION O/ (E) C.M.U. EXTERIOR WALL; ALUM. VAPOR RETARDER ON ROOM SIDE & CONTINUOUS ACROSS FURRING STRIPS; FLOOR TO STRUCTURE; RIP 2x FURRING STRIPS TO MATCH DIMENS. OF RIGID INSULATION; SEE SPECS. NOTE: SADDLE TIE! HAS DOUBLE LOOP! @ SUPPORT 1/4" ALUM. STOREFRONT! W/ INSULATED GLASS! LITES AND THERMAL! BREAKS; SEE SPECS. WOOD BOTTOM! CHORD BUILDING 1500 ARCHITECTURAL DETAILS SECURE FURRING STRIPS! TO C.M.U. W/ 1/4" FLAT HEAD! SCREWS INTO EXPAN. SHEILDS! @ 12" O.C. VERT. CEILING DETAILS BUILDINGS 1400 & 1500 HVAC & LIGHTING RENOVATIONS FURRED WALL DETAILS ALUM. BOX SECTION! W/ THERMAL BREAKS; ! SEE SPECS. FILE NO. 44-C1 IDENTIFICATION STAMP DIV. OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES THE DATA SET FORTH ON THIS SHEET IS THE PROPERTY OF YOUNG ENGINEERING SERVICES. IT IS AN INSTRUMENT OF SERVICE AND MAY NOT BE ALTERED, REPRODUCED OR USED WITHOUT THE CONSENT OF YOUNG ENGINEERING SERVICES. THE PROPER TRANSFER OF DATA HEREIN, ELECTRONICALLY OR OTHERWISE, SHALL BE THE RESPONSIBILITY OF THE USER WITHOUT LIABILITY TO YOUNG ENGINEERING SERVICES. UNAUTHORIZED USE IS PROHIBITED. AC:_________FLS_________SS__________ DETAIL @ SILL 6" = 1'-0" 11 A6.01 DATE:________________________________ A6.01 · · · PRIME DESIGN GROUP ELECTRICAL ENGINEERING SINCE 1990 B. 1500 FIRST FLOOR LIGHTING PLAN - DEMOLITION 1 GENERAL NOTES: N 4"=1'-0" SHEET NOTES: FILE NO. 44-C1 IDENTIFICATION STAMP DIV. OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES xx-xxxx AC:_________FLS_________SS__________ DATE:________________________________ E2.3 B. 1500 FIRST FLOOR LIGHTING PLAN - DEMOLITION BUILDINGS 1400 & 1500 HVAC & LIGHTING RENOVATIONS CABRILLO COLLEGE 303 POTRERO ST. SUITE 42-304 SANTA CRUZ, CA 95060 PHONE: (831)430-3600 FAX: (831)430-9490 PDG PROJECT NO.: 14114.00 · · · PRIME DESIGN GROUP OUTDOOR WALKWAY ELECTRICAL ENGINEERING SINCE 1990 303 POTRERO ST. SUITE 42-304 SANTA CRUZ, CA 95060 PHONE: (831)430-3600 FAX: (831)430-9490 PDG PROJECT NO.: 14114.00 ELECT 1523 OFFICE JAN. 1524 CONFERENCE 1520A OFFICE WOMEN DUCT SHAFT 1520E STORAGE OUTDOOR WALKWAY CABRILLO COLLEGE 1522-A CLASSROOM EXAM 1520 CLASSROOM OUTDOOR WALKWAY 1522B CLASSROOM 1522A CLASSROOM 1521B CLASSROOM 1521A CLASSROOM STORAGE OUTDOOR WALKWAY B. 1500 SECOND FLOOR LIGHTING PLAN - DEMOLITION 1 GENERAL NOTES: N 4"=1'-0" SHEET NOTES: FILE NO. 44-C1 IDENTIFICATION STAMP DIV. OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES xx-xxxx AC:_________FLS_________SS__________ DATE:________________________________ E2.4 B. 1500 SECOND FLOOR LIGHTING PLAN - DEMOLITION 1520 CLASSROOM BUILDINGS 1400 & 1500 HVAC & LIGHTING RENOVATIONS MEN · · · PRIME DESIGN GROUP ELECTRICAL ENGINEERING SINCE 1990 B. 1500 FIRST FLOOR LIGHTING PLAN - NEW WORK 1 N 4"=1'-0" NOTE: ALL FIXTURES ON THIS SHEET ARE NEW AND TYPE 'A', U.O.N. SHEET NOTES: GENERAL NOTES: FILE NO. 44-C1 IDENTIFICATION STAMP DIV. OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES xx-xxxx AC:_________FLS_________SS__________ DATE:________________________________ E2.5 B. 1500 FIRST FLOOR LIGHTING PLAN - NEW WORK BUILDINGS 1400 & 1500 HVAC & LIGHTING RENOVATIONS CABRILLO COLLEGE 303 POTRERO ST. SUITE 42-304 SANTA CRUZ, CA 95060 PHONE: (831)430-3600 FAX: (831)430-9490 PDG PROJECT NO.: 14114.00 · · · PRIME DESIGN GROUP OUTDOOR WALKWAY ELECTRICAL ENGINEERING SINCE 1990 303 POTRERO ST. SUITE 42-304 SANTA CRUZ, CA 95060 PHONE: (831)430-3600 FAX: (831)430-9490 PDG PROJECT NO.: 14114.00 ELECT 1523 OFFICE JAN. 1524 CONFERENCE 1520A OFFICE WOMEN DUCT SHAFT 1520E STORAGE OUTDOOR WALKWAY CABRILLO COLLEGE 1522-A CLASSROOM EXAM 1520 CLASSROOM OUTDOOR WALKWAY 1522B CLASSROOM 1522A CLASSROOM 1521B CLASSROOM 1521A CLASSROOM STORAGE OUTDOOR WALKWAY B. 1500 SECOND FLOOR LIGHTING PLAN - NEW WORK 1 N 4"=1'-0" NOTE: ALL FIXTURES ON THIS SHEET ARE NEW AND TYPE 'A', U.O.N. GENERAL NOTES: SHEET NOTES: FILE NO. 44-C1 IDENTIFICATION STAMP DIV. OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES xx-xxxx AC:_________FLS_________SS__________ DATE:________________________________ E2.6 B. 1500 SECOND FLOOR LIGHTING PLAN - NEW WORK 1520 CLASSROOM BUILDINGS 1400 & 1500 HVAC & LIGHTING RENOVATIONS MEN